• 제목/요약/키워드: Contrast-enhanced computed tomography

Search Result 135, Processing Time 0.024 seconds

Effects of Remote Ischemic Pre-Conditioning to Prevent Contrast-Induced Nephropathy after Intravenous Contrast Medium Injection: A Randomized Controlled Trial

  • Dihia Belabbas;Caroline Koch;Segolene Chaudru;Mathieu Lederlin;Bruno Laviolle;Estelle Le Pabic;Dominique Boulmier;Jean-Francois Heautot;Guillaume Mahe
    • Korean Journal of Radiology
    • /
    • v.21 no.11
    • /
    • pp.1230-1238
    • /
    • 2020
  • Objective: We aimed to assess the effects of remote ischemic pre-conditioning (RIPC) on the incidence of contrast-induced nephropathy (CIN) after an intravenous (IV) or intra-arterial injection of contrast medium (CM) in patient and control groups. Materials and Methods: This prospective, randomized, single-blinded, controlled trial included 26 patients who were hospitalized for the evaluation of the feasibility of transcatheter aortic valve implantation and underwent investigations including contrast-enhanced computed tomography (CT), with Mehran risk scores greater than or equal to six. All the patients underwent four cycles of five minute-blood pressure cuff inflation followed by five minutes of total deflation. In the RIPC group (n = 13), the cuff was inflated to 50 mm Hg above the patient's systolic blood pressure (SBP); in the control group (n = 13), it was inflated to 10 mm Hg below the patient's SBP. The primary endpoint was the occurrence of CIN. Additionally, variation in the serum levels of cystatin C was assessed. Results: One case of CIN was observed in the control group, whereas no cases were detected in the RIPC group (p = 0.48, analysis of 25 patients). Mean creatinine values at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 88 ± 32 μmol/L, 91 ± 28 μmol/L and 82 ± 29 μmol/L, respectively (p = 0.73) in the RIPC group, whereas in the control group, they were 100 ± 36 μmol/L, 110 ± 36 μmol/L, and 105 ± 34 μmol/L, respectively (p = 0.78). Cystatin C values (median [Q1, Q3]) at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 1.10 [1.08, 1.18] mg/L, 1.17 [0.97, 1.35] mg/L, and 1.12 [0.99, 1.24] mg/L, respectively (p = 0.88) in the RIPC group, whereas they were 1.11 [0.97, 1.28] mg/L, 1.13 [1.08, 1.25] mg/L, and 1.16 [1.03, 1.31] mg/L, respectively (p = 0.93), in the control group. Conclusion: The risk of CIN after an IV injection of CM is very low in patients with Mehran risk score greater than or equal to six and even in the patients who are unable to receive preventive hyperhydration. Hence, the Mehran risk score may not be an appropriate method for the estimation of the risk of CIN after IV CM injection.

Impact of Initial Helical Abdominal Computed Tomography on the Diagnosis of Hollow Viscus Injury and Blunt Abdominal Traumare (복부 둔상 및 유강장기 손상에 있어서 초기 나선형 복부전산화 단층촬영의 진단적 가치)

  • Cho, Young-Duck;Hong, Yun-Sik;Lee, Sung-Woo;Choi, Sung-Hyuk;Yoon, Young-Hoon;Lim, Sung-Ik;Jang, Ik-Jin;Baek, Seung-Won
    • Journal of Trauma and Injury
    • /
    • v.21 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • Purpose: This study was conducted to examine the clinical significance IV-contrasted helical abdomen computed tomography (CT) as a diagnostic screening tool to evaluate hollow viscus injury in blunt abdominal trauma patients. Methods: This is a retrospective study encompassing 108 patients, presenting to Korea University Medical Center (KUMC) Emergency Department (ED) from January 2007 to December 2007, with an initial CT finding suggestive of intra-abdominal injury. An initial non-enhanced abdomen CT was taken, followed by an enhanced CT with intravenous contrast. Patients' demographic data, as well as the mechanisms of injury, were inquired upon and obtained, initial diagnosis, as dictated by specialized radiologists, were added to post-operational (post-OP) findings and to additional CT findings acquired during their hospital stays, and all were combined to arrive at final diagnosis. Initial CT findings were further compared with the final diagnosis, yielding values for sensitivity, specificity, and accuracy, as well as positive and negative predictive values. Patients were further divided into two groups, namely, those that underwent operational intervention and those that did not. The initial CT findings of each group were subsequently compared and analyzed. Results: Initial CT scans revealed abnormal findings in a total of 212 cases - solid organ injuries being the most common finding, as was observed in 97 cases. Free fluid accumulation was evident in another 69 cases. Based on the CT findings, 77 cases (71.3%) were initially diagnosed as having a solid organ injury, 20 cases (18.5%) as having a combined (solid organ + hollow viscus) injury, and 11 cases (10.2%), as having an isolated hollow viscus injury. The final diagnosis however, were somewhat different, with only 67 cases (62.0%) attributed to solid organ injury, 31 cases (28.7%) to combined injury (solid + hollow), and 10 cases (9.3%) to hollow viscus injury. The sensitivity (CI 95%) of the initial helical CT in diagnosing hollow viscus injury was 75.6%, and its specificity was 100%. The accuracy in diagnosing hollow viscus injury was also meaningfully lower compared to that in diagnosis of solid organ injury. Among patients initially diagnosed with solid organ injuries, 10 patients (2 from follow-up CT and 8 from post-OP finding) turned out to have combined injuries. A total of 38 patients underwent an operation, and the proportion of initial CT findings suggesting free air, mesenteric hematoma or bowel wall thickening turned out to be significantly higher in the operation group. Conclusion: Abdominal CT was a meaningful screening test for hollow viscus injury, but the sensitivity of abdominal CT was significantly lower in detecting hollow viscus injury as compared to solid organ injury. This calls for special consideration and careful observation by the ED physicians when dealing with cases of blunt abdominal trauma.

Incidental Breast Lesions on Chest CT: Clinical Significance and Differential Features Requiring Referral (흉부 전산화단층촬영에서 우연히 발견된 유방 병변: 임상적 중요성 및 진료 의뢰가 필요한 특징적 영상 소견)

  • Choi, Yun Jung;Kim, Tae Hoon;Cha, Yoon Jin;Son, Eun Ju;Gweon, Hye Mi;Park, Chul Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.303-310
    • /
    • 2018
  • Purpose: To evaluate the CT features of incidental breast lesions on chest CT and to suggest useful criteria for referral to a specialized breast unit. Materials and Methods: Between May 2009 and April 2014, enhanced chest CT examination reports containing the key word 'breast' were reviewed retrospectively. Patients who had incidental breast lesion and were referred to a specialized breast unit and then underwent pathological confirmation or follow-up over a 1-year period were included. Finally, 86 patients (all female, mean age, $48.9{\pm}12.6years$) were enrolled. Two radiologists evaluated lesion characteristics, including size, shape, margins, and enhancement. The correlations between the CT features and pathologies were evaluated, and the diagnostic accuracy of CT features in various combinations was assessed. Results: Among the CT features, irregular shape, non-circumscribed margin, and high contrast enhancement were different between malignant and benign lesions (p < 0.05). The combination of non-circumscribed margin and high contrast enhancement had the highest accuracy (97.7%). Conclusion: Reliable CT features for incidental malignant breast masses are irregular shape, non-circumscribed margin, and high contrast enhancement. The combination of non-circumscribed margin and high contrast enhancement could help distinguish incidental malignant breast lesions and indicate referral to a specialized breast unit.

Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study (약하게 조영증강된 병변의 유방 전용 CT 영상의 대조도 개선을 위한 적응적 영상 재조정 방법: 팬텀 연구)

  • Bitbyeol Kim;Ho Kyung Kim;Jinsung Kim;Yongkan Ki;Ji Hyeon Joo;Hosang Jeon;Dahl Park;Wontaek Kim;Jiho Nam;Dong Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1477-1492
    • /
    • 2021
  • Purpose Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions, an adaptive image rescaling (AIR) technique was proposed. Materials and Methods Two disks containing five identical holes and five holes of different diameters were scanned using 60/100 kVp to obtain single-energy CT (SECT), dual-energy CT (DECT), and AIR images. A piece of pork was also scanned as a subclinical trial. The image quality was evaluated using image contrast and contrast-to-noise ratio (CNR). The difference of imaging performances was confirmed using student's t test. Results Total mean image contrast of AIR (0.70) reached 74.5% of that of DECT (0.94) and was higher than that of SECT (0.22) by 318.2%. Total mean CNR of AIR (5.08) was 35.5% of that of SECT (14.30) and was higher than that of DECT (2.28) by 222.8%. A similar trend was observed in the subclinical study. Conclusion The results demonstrated superior image contrast of AIR over SECT, and its higher overall image quality compared to DECT with half the exposure. Therefore, AIR seems to have the potential to improve the detectability of lesions with dedicated breast CT.

Hybrid Filter Based on Neural Networks for Removing Quantum Noise in Low-Dose Medical X-ray CT Images

  • Park, Keunho;Lee, Hee-Shin;Lee, Joonwhoan
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.102-110
    • /
    • 2015
  • The main source of noise in computed tomography (CT) images is a quantum noise, which results from statistical fluctuations of X-ray quanta reaching the detector. This paper proposes a neural network (NN) based hybrid filter for removing quantum noise. The proposed filter consists of bilateral filters (BFs), a single or multiple neural edge enhancer(s) (NEE), and a neural filter (NF) to combine them. The BFs take into account the difference in value from the neighbors, to preserve edges while smoothing. The NEE is used to clearly enhance the desired edges from noisy images. The NF acts like a fusion operator, and attempts to construct an enhanced output image. Several measurements are used to evaluate the image quality, like the root mean square error (RMSE), the improvement in signal to noise ratio (ISNR), the standard deviation ratio (MSR), and the contrast to noise ratio (CNR). Also, the modulation transfer function (MTF) is used as a means of determining how well the edge structure is preserved. In terms of all those measurements and means, the proposed filter shows better performance than the guided filter, and the nonlocal means (NLM) filter. In addition, there is no severe restriction to select the number of inputs for the fusion operator differently from the neuro-fuzzy system. Therefore, without concerning too much about the filter selection for fusion, one could apply the proposed hybrid filter to various images with different modalities, once the corresponding noise characteristics are explored.

Diagnostic Imaging of Nasal Adenocarcinoma in Four Dogs (개에서 비강 샘암종의 영상 진단 증례)

  • Jung, Joo-Hyun;Chang, Jin-Hwa;Oh, Sung-Kyoung;Kim, Kyoung-Min;Lee, Sung-Ok;Lee, Jung-Min;Kim, Hak-Sang;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.355-360
    • /
    • 2006
  • Four dogs with similar respiratory signs were referred to Veterinary Medical Teaching Hospital, Seoul National University. The clinical signs observed in these cases were anorexia, nasal discharge, sneezing, epistaxis, ocular discharge, and exophthalmoses. The routine laboratory tests revealed leukocytosis in two cases. On the skull radiographs, soft tissue density filled nasal cavity with loss of turbinate detail and increased density in frontal sinuses were found in all cases. Lysis of nasal bone was seen in two cases. Lysis of zygomatic arch was seen in one case. On computed tomography scan images, asymmetrical destruction of turbinate and nasal septum, and the superimposition of a soft tissue mass over the turbinate with peripheral contrast enhanced effect were identified in all cases. Destruction of ipsilateral orbital bone and invasion to retrobulbar region were visualized in all cases. In addition, all cases had lysis of cribriform plate. Lysis of nasal bone and destruction of hard palate were seen in two cases. Swelling of submandibular lymph node and salivary gland was seen in a case. Invasion to brain was identified in a case. All cases were diagnosed as nasal adenocarcinoma by cytology with fine needle aspiration and curettage.

A Case of Type 1 Neurofibromatosis Associated with Multiple Metastatic Gastrointestinal Stromal Tumors (다발전이성 위장관 간질종양을 동반한 제 1형 신경섬유종증 1예)

  • Jang, Hyo Jin;Koh, Sung Ae;Jeong, Da Eun;Jung, Ji Yoon;Goo, Eun Ju;Lee, Kyoung Hee;Choi, Joon Hyuk;Hyun, Myung Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.105-108
    • /
    • 2013
  • Type 1 neurofibromatosis (von Recklinghausen's disease, NF-1) is an autosomal-dominant neurocutaneous-disorder characterized by systemic cafe'-au-lait spots, multiple cutaneous neurofibromas, axillary or inguinal freckling, and Lisch nodules (pigmented iris hamartomas). Approximately 10-25% of NF1 patients have gastrointestinal neoplasms. Gastrointestinal stromal tumor (GIST) in patients with neurofibromatosis is most commonly found in the small bowel and the stomach, and approximately 60% of such patients have multiple tumors or multiple tumor sites. Although, the increased incidence of GIST in patients with neurofibromatosis is well documented in pathology literature in English, but has rarely been documented in Korea. Here, we report a case of multiple GISTs in a 48-year-old woman accompanied by NF1. She was admitted to Yeung-nam University Hospital with complaints of melena and dyspnea. A contrast-enhanced computed tomography (CT) scan revealed that multiple soft tissue masses were occupying the entire peritoneal cavity. An ultrasonogram- guided biopsy was performed and the tumors were found to have been composed of tumor cells that were positive for c-kit protein. The patient was put on Imatinib mesylate treatment, and further follow-up will be carried out.

Immune thrombocytopenia associated with sarcoidosis (면역성혈소판감소증을 동반한 사르코이드증)

  • Jeong, Da Eun;Kim, Min Kyoung;Koh, Sung Ae;Lee, Kyoung Hee;Choi, Joon Hyuk;Hong, Young Hoon;Cho, Jae Ho;Goo, Eun Ju;Hyun, Myung Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.32 no.1
    • /
    • pp.26-30
    • /
    • 2015
  • Sarcoidosis is a systemic disease of unknown cause involving multiple organs and is characterized by noncaseating granuloma. Immune thrombocytopenia (ITP) is an autoimmune disease characterized by increased peripheral platelet destruction due to the presence of an antibody to the platelet and abnormal platelet production. There is no known pathogenesis that occurs concurrently with ITP and sarcoidosis. However, considering together of 2 known pathogenesis, abnormal immune response triggers either ITP or sarcoidosis. The disease that develops first stimulates secondary disease. After development of secondary disease, they stimulate each other. A few cases of ITP associated with sarcoidosis are well documented in English; however, the disease has rarely been reported in Korea. Here, we report on a case of ITP with sarcoidosis in a 29-year-old man. He suffered from easy bruising. The chest X-ray and the contrast-enhanced computed tomography scan showed bihilar lymphadenopathy and reticulonodular infiltrates. Bone marrow study and fluoroscopy-guided percutaneous needle biopsy were performed and the patient was diagnosed with sarcoidosis and ITP. He was put on 400 mg/kg of intravenous immunoglobulin for 5 days and administered oral steroids and further follow-up will be carried out. He has shown a good response without significant bleeding event. However, administration of more oral steroid and additional follow-up is required than for single disease, whether sarcoidosis or ITP.

Pancreatic Exocrine Adenocarcinoma in a Cat (고양이에서 발생한 췌장 외분비 선암종 1례)

  • Park, Noh-Won;Lee, Seung-Yeoun;Lee, So-Yun;Song, Sun-Hye;Choi, Yang-Kyu;Eom, Ki-Dong
    • Journal of Veterinary Clinics
    • /
    • v.30 no.3
    • /
    • pp.189-192
    • /
    • 2013
  • An 8-year-old, neutered female Korean short hair cat was referred with severe vomiting and anorexia. Abdominal mass effect was seen in the cranial abdomen on radiographs, and a mass with a heterogeneous echogenic pattern was observed medial to the right kidney on ultrasonography. On computed tomography, a large mass with soft tissue attenuation and a contrast-enhanced capsule was seen. In histopathological findings, the acinar structures were lined with irregular cuboidal cells that have pale eosinophilic cytoplasm and round to oval nuclei. Based on these diagnostic imaging and histopathological findings, the mass was diagnosed as pancreatic exocrine adenocarcinoma.

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF