• Title/Summary/Keyword: Contrast ultrasound

Search Result 142, Processing Time 0.024 seconds

Effect of Ultrasound Irradiation during Cementation Process for Recovery of Iridium (이리듐 회수를 위한 시멘테이션 공정 중 초음파 조사의 영향)

  • Kim, Seunghyun;Kim, Young-Jin;Seo, Jun-Hyung;Cho, Jin-Sang;Cho, Kye-Hong;Lee, Jaeryeong
    • Resources Recycling
    • /
    • v.30 no.6
    • /
    • pp.61-67
    • /
    • 2021
  • This work investigated the cementation of iridium from iridium-containing hydrochloric acid leachate. Zinc powder was used as the reducing agent, and the effects of the stoichiometric ratio of Zn/Ir, initial Ir concentration, initial pH, reaction time, and ultrasound irradiation on iridium recovery were investigated. When only the stirrer was used for cementation, the iridium recovery increased with the addition amount of zinc, and the recovery of about 70% at 40 times the stoichiometric ratio of Zn/Ir. In contrast, when employing ultrasonic irradiation with stirring, the recovery of iridium decreased at 20 times or less the stoichiometric amount of zinc. The recovery of iridium increased at 40 times the stoichiometric ratio of Zn/Ir. This result may be due to the ionization of zinc and re-dissolution of iridium during the ultrasound irradiation treatment. When a combination of ultrasonic irradiation and stirring was used for cementation, the iridium recovery increased by more than 27% compared to that when using only the stirrer. It was possible to recover 99% of iridium under the following conditions: reaction time, 60 min; initial pH, 0.01; volume of leachate, 100 mL; 1770 ppm Ir, 40 times the stoichiometric ratio of Zn/Ir.

A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography (유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구)

  • Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.751-759
    • /
    • 2023
  • Breast ultrasonography is difficult to image in fatty breasts and to find micro-calcification, but the discovery of micro-calcification is very important for breast cancer screening. Among the color Doppler artifact of ultrasound, twinkle artifact mainly occur on strong reflectors such as stones or calcification in images, and evaluation methods using them are clinically being used. In this study, we are conducting experiments on the color Doppler settings of ultrasound equipment, such as repetition frequency, ensemble, persist, wall filtering, smoothing, linear density, and dissociation value, by producing a breast simulation phantom using the largest amount of calcium phosphate among breast implants. The purpose of this study was to improve the contrast of twinkle artifact in breast ultrasound examinations and to maximize their use in clinical practice. As a result, the pulse repetition frequency occurred in the range of 3.6 kHz to 7.2 kHz, and did not occur above 10.5 kHz. For ensembles, twinkle artifact occurred in all sizes of calcification under low conditions, and in threshold settings, the twinkle artifact increased slightly only under 80 to 100 conditions, and did not occur in 1 mm size calcification. Persist, wall filter, smoothing, and line density settings did not have much meaning in the setting variable because conditions did not increase by condition, and pulse repetition frequency, ensemble, and thresholds had the greatest impact on the twinkling artifact image. This study is expected to help examiners select optimal conditions to effectively increase twinkle artifact by adjusting color Doppler settings.

Comparative Investigation of Single Voxel Magnetic Resonance Spectroscopy and Dynamic Contrast Enhancement MR Imaging in Differentiation of Benign and Malignant Breast Lesions in a Sample of Iranian Women

  • Faeghi, Fariborz;Baniasadipour, Banafsheh;Jalalshokouhi, Jalal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8335-8338
    • /
    • 2016
  • Purpose: To make a comparison of single voxel magnetic resonance spectroscopy (SV-MRS) and dynamic contrast enhancement (DCE) MRI for differentiation of benign and malignant breast lesions in a sample of Iranian women. Materials and Methods: A total of 30 women with abnormal breast lesions detected in mammography, ultrasound, or clinical breast exam were examined with DCE and SV-MRS. tCho (total choline) resonance in MRS spectra was qualitatively evaluated and detection of a visible tCho peak at 3.2 ppm was defined as a positive finding for malignancy. Different types of DCE curves were persistent (type 1), plateau (type 2), and washout (type 3). At first, lesions were classified according to choline findings and types of DCE curve, finally being compared to pathological results as the standard reference. Results: this study included 19 patients with malignant lesions and 11 patients with benign ones. While 63.6 % of benign lesions (7 of 11) showed type 1 DCE curves and 36.4% (4 of 11) showed type 2, 57.9% (11of 19) of malignant lesions were type 3 and 42.1% (8 of 19) type 2. Choline peaks were detected in 18 of 19 malignant lesions and in 3 of 11 benign counterparts. 1 malignant and 8 benign cases did not show any visible resonance at 3.2 ppm so SV-MRS featured 94.7% sensitivity, 72.7 % specificity and 86.7% accuracy.Conclusions: The present findings indicate that a combined approach using MRS and DCE MRI can improve the specificity of MRI for differentiation of benign and malignant breast lesions.

Imaging diagnosis of hepatic lipidosis in a cat

  • Heo, Seong-Hun;Yoon, Young-Min;Hwang, Tae-Sung;Jung, Dong-In;Lee, Hee-Chun
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.2
    • /
    • pp.99-101
    • /
    • 2018
  • A 5-year-old intact female Persian cat was referred with anorexia and vomiting. Physical examination revealed icterus in the pinna, oral mucosa, and sclera. Ultrasonography revealed several findings including uniformly hyperechoic hepatic parenchyma compared to adjacent falciform fat, increased attenuation of the ultrasound beam, and poor visualization of intrahepatic vessel borders. Computed tomography revealed hypoattenuation of the hepatic parenchyma with a radiodensity value of -60 Hounsfield units. The adjacent intrahepatic vessels appeared hyperattenuated relative to the hepatic parenchyma as if the vessels were contrast-enhanced. Based on ultrasonography and computed tomography results, the cat was tentatively diagnosed as feline hepatic lipidosis.

Development of Laser Induced Real Time Photoacoustic Tomography Imaging System and Phantom Evaluation (레이저 유도방식의 실시간 광음향 단층영상 기술 개발과 팬텀이미지 평가)

  • Ryu, Sang-Hun;Shin, Dong-Ho;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.879-884
    • /
    • 2012
  • Photoacoustic Tomography (PAT) is a promising medical imaging modality by reason of its particularity. It combines optical imaging contrast of optical imaging with the spatial resolution of ultrasound imaging and can demonstrate change of biological feature in an image. For that reason, many studies are in progress to apply this technic for diagnosis. But, real-time PAT system is necessary to confirm a biological reaction induced by external stimulation immediately. Thus, we developed a real-time PAT system using linear array transducer and self-developed Data acquisition board (DAQ) resources, To evaluate the feasibility and performance of our proposed system, two type of phantom test were also performed. As a result of those experiments, the proposed system shows enough performance and confirm its usefulness.

Visualization of Contrast Enhancement Patterns in Ultrasound Images (의료 초음파 영상에서 조영증강 패턴의 가시화 기법)

  • Lee, Jun-Yong;Jung, Joong-Eun;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.04a
    • /
    • pp.862-863
    • /
    • 2015
  • 본 연구에서는 조영증강 초음파 진단에서 혈류의 패턴을 효과적으로 판단할 수 있게 하기 위하여 조영제의 확산패턴을 영상으로 표현하는 방법론을 제안한다. 초음파 영상에서 조영제의 전이 시간에 대한 파라미터의 가시화 기법과, 단계별 전이패턴을 단일 영상으로 표현하는 방법을 제시함으로써, 병변의 진단 및 분석과정에서 대상 영역 내 혈류의 형태와 속도를 효과적으로 판별할 수 있게 한다. 분석과정의 필요에 따라 영상에서 정밀도를 선택적으로 적용할 수 있도록 하였으며, 노이즈 제거를 위한 필터링 과정과 단계별 전이 시점의 위치에 대한 영역 분할 과정을 거쳐 영상 생성결과를 개선할 수 있도록 하였다.

Thrombosed Fusiform Dilatation of Persistent Median Artery with Normal Median Nerve (정상 정중신경에서 혈전을 가진 잔류정중동맥의 예)

  • Park, Gi-Young;Kwon, Dong Rak;Kwon, Dae Gil;Jung, Won Bin
    • Clinical Pain
    • /
    • v.18 no.1
    • /
    • pp.40-43
    • /
    • 2019
  • Carpal tunnel syndrome can be produced by abnormal mass effect due to trauma, ganglion cysts, various soft tissue tumors, musculotendinous variants, and aberrant vascular structures. Persistent median artery is one of the causes of the carpal tunnel syndrome. Thrombosed persistent median artery usually accompanies the anomaly of the median nerve and causes a sudden onset of severe pain and paresthesia. In contrast to previous literature, we report the rare case of gradual onset and mild symptom of a 53-year-old man with a thrombosed persistent median artery but without anomaly of the median nerve and abnormal finding of electrophysiologic study.

Computed tomography and magnetic resonance imaging features of suspected transitional cell carcinoma lesions involving the bladder, prostate, and urethra in a dog: a case report

  • Wooseok Jin;Sang-Kwon Lee;Seulgi Bae;Taeho Oh;Kija Lee
    • Korean Journal of Veterinary Research
    • /
    • v.63 no.4
    • /
    • pp.39.1-39.5
    • /
    • 2023
  • A 14-year-old, spayed female, poodle was presented with dysuria and hematuria. A mass that appeared hypoechoic on ultrasound and hypoattenuating on computed tomography (CT) extended from the bladder neck to the urethra. Magnetic resonance imaging (MRI) showed the mass invading the muscular layer of the bladder, urethra, and prostate with distinct margins. Transitional cell carcinoma (TCC) was confirmed with the CADET-BRAF test. This study describes the CT and MRI features of suspected TCC lesions involving the bladder, prostate, and urethra. MRI showed superior soft tissue contrast resolution, enabling evaluation of invasion of the muscular layer of the bladder and urethra.

A Case of Jejuno-jejunal Intussusception in Henoch-Sch$\"{o}$nlein Purpura (Henoch-Sch$\"{o}$nlein 자반증 환아에서 동반된 공장-공장형 장중첩증 1례)

  • Park, Hyun-Kyung;Chung, Yoon-Sook;Kim, Ki-Joong;Kim, Yong-Joo;Lee, Hahng;Rhim, Hyun-Chul
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.228-232
    • /
    • 2001
  • Gastrointestinal involvement occurs in two thirds of children with Henoch-Sch$\"{o}$nlein purpura (HSP) and intussusception is by far the most common abdominal complication. Intussusception in HSP almost originates in the small bowel, which is in contrast with idiopathic intussusception. Earlier diagnosis and prompt treatment of intra-abdominal complications can reduce the mortality and ultrasound is the imaging modality of choice in evaluation the bowel manifestations of HSP. We report a case of jejuno-jejunal intussusception associated with HSP in a 5-year-old boy who presented with diffuse abdominal pain and vomiting after a few days of HSP onset. Abdominal ultrasound demonstrated intussusception in the jejunum with well defined target appearance because of the thickened intussusceptum, which disappeared on the computerized tomographic examination checked approximately 24 hours later. A brief review of literature was made.

  • PDF

Improvement of Medical Ultrasound Strain Image Using Lateral Motion Compensation (측방향 움직임 보상을 이용한 초음파 의료용 변형률 영상의 화질개선)

  • Park, Myung-Ki;Kwon, Sung-Jae;Jeong, Mok-Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.239-248
    • /
    • 2011
  • In order to improve the quality of strain images in medical ultrasound imaging, displacements need to be accurately estimated. In this paper, in order to apply one-dimensional displacement estimation methods to two-dimensional motion estimation, the axial and lateral displacements are separately estimated. In order to estimate lateral displacements, one-dimensional signals aligned in the lateral direction are converted to analytic signals, which are then crosscorrelated. Strain images are produced by first compensating two-dimensional displacements for lateral motion with lateral motion displacement estimates obtained from the proposed lateral displacement estimation algorithm and then estimating axial displacements. Both phantom and human data experiments show that the proposed method provides better signal-to-noise ratio and contrast-to-noise ratio characteristics than a conventional strain imaging method that utilizes axial displacement estimates only.