• Title/Summary/Keyword: Contouring

Search Result 238, Processing Time 0.037 seconds

Scientific review of the aesthetic uses of botulinum toxin type A

  • Park, Mee Young;Ahn, Ki Young
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Botulinum toxin type A (BoNT-A), onabotulinumtoxinA (Botox) was approved by the United States Food and Drug Administration for temporary improvement of glabellar lines in patients 65 years and younger in 2002, and has also been used widely for aesthetic purposes such as hyperhidrosis, body shape contouring, and other noninvasive facial procedures. BoNT-A inhibits presynaptic exocytosis of acetylcholine (ACh)-containing vesicles into the neuromuscular junction at cholinergic nerve endings of the peripheral nervous system, thereby paralyzing skeletal muscles. ACh is the most broadly used neurotransmitter in the somatic nervous system, preganglionic and postganglionic fibers of parasympathetic nerves, and preganglionic fibers or postganglionic sudomotor nerves of sympathetic nerves. The scientific basis for using BoNT-A in various cosmetic procedures is that its function goes beyond the dual role of muscle paralysis and neuromodulation by inhibiting the secretion of ACh. Although the major target organs for aesthetic procedures are facial expression muscles, skeletal body muscles, salivary glands, and sweat glands, which are innervated by the somatic or autonomic nerves of the peripheral cholinergic nerve system, few studies have attempted to directly explain the anatomy of the areas targeted for injection by addressing the neural physiology and rationale for specific aesthetic applications of BoNT-A therapy. In this article, we classify the various cosmetic uses of BoNT-A according to the relevant component of the peripheral nervous system, and describe scientific theories regarding the anatomy and physiology of the cholinergic nervous system. We also review critical physiological factors and conditions influencing the efficacy of BoNT-A for the rational aesthetic use of BoNT-A. We hope that this comprehensive review helps promote management policies to support long-term, safe, successful practice. Furthermore, based on this, we look forward to developing and expanding new advanced indications for the aesthetic use of BoNT-A in the future.

Excisional lipectomy versus liposuction in HIV-associated lipodystrophy

  • Barton, Natalie;Moore, Ryan;Prasad, Karthik;Evans, Gregory
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.685-690
    • /
    • 2021
  • Background Human immunodeficiency virus (HIV)-associated lipodystrophy is a known consequence of long-term highly active antiretroviral therapy (HAART). However, a significant number of patients on HAART therapy were left with the stigmata of complications, including fat redistribution. Few studies have described the successful removal of focal areas of lipohypertrophy with successful outcomes. This manuscript reviews the outcomes of excisional lipectomy versus liposuction for HIV-associated cervicodorsal lipodystrophy. Methods We performed a 15-year retrospective review of HIV-positive patients with lipodystrophy. Patients were identified by query of secure operative logs. Data collected included demographics, medications, comorbidities, duration of HIV, surgical intervention type, pertinent laboratory values, and the amount of tissue removed. Results Nine male patients with HIV-associated lipodystrophy underwent a total of 17 procedures. Of the patients who underwent liposuction initially (n=5), 60% (n=3) experienced a recurrence. There were a total of three cases of primary liposuction followed by excisional lipectomy. One hundred percent of these cases were noted to have a recurrence postoperatively, and there was one case of seroma formation. Of the subjects who underwent excisional lipectomy (n=4), there were no documented recurrences; however, one patient's postoperative course was complicated by seroma formation. Conclusions HIV-associated lipodystrophy is a disfiguring complication of HAART therapy with significant morbidity. Given the limitations of liposuction alone as the primary intervention, excisional lipectomy is recommended as the primary treatment. Liposuction may be used for better contouring and for subsequent procedures. While there is a slightly higher risk for complications, adjunctive techniques such as quilting sutures and placement of drains may be used in conjunction with excisional lipectomy.

Gluteal Region Reshaping of Massive Weight Loss Patients-A Decision-Making Strategy

  • Mahgoub, Mohamed Ali;Zeina, Ahmed Mahmoud;El-Din, Ahmed Mohamed Bahaa;El-Sabbagh, Ahmed Hassan;Bassetto, Franco;Vindigni, Vincenzo
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.289-295
    • /
    • 2022
  • Background Massive weight loss (MWL) is a very common presentation that you may face as a plastic surgeon. Each patient has his own individual criteria, so, you should work according to a well-organized plan, especially when such cases have concerns about their gluteal area contour that were neglected before by many surgeons. A decision-making strategy was used to give a personalized treatment for targeting gluteal region reshaping of MWL patients. Methods This study considered all patients with MWL subjected to buttock reshaping. There was no randomization in treatment; there was a case-by-case assessment. We analyzed the features of the buttocks, the type of surgery performed, the outcomes, and the complications. Results Fifty two patients were included (41 females and 11 males), ages ranged between 21 and 66 years. Demographic data, preoperative body mass index (BMI), duration of surgery, type of surgery, and postoperative complications were collected. Statistically significant improvements were observed in gluteal ptosis and patient satisfaction grades. Conclusion Aesthetic improvement of the buttocks involves either augmentation or contouring that may be obtained by liposculpture, surgical lifting, or combination. Patients with MWL have high expectations and are often treated with multiple procedures. Thus, an easy strategic approach personalized on each patient to treat multiple adjacent areas in one operation is necessary. Adipose tissue distribution, gluteal skin status, and BMI were the main factors that can forcefully affect our plan to guarantee reduction of unpleasant results and complications and improve patient satisfaction.

Psammomatoid Juvenile Ossifying Fibroma of the Maxilla Misdiagnosed as Fibrous Dysplasia: A Clinicopathologic Case Report

  • Jong-Ho Kim;Jiwon Kang;Seong-ik Kim;Byung Jun Kim
    • Archives of Plastic Surgery
    • /
    • v.50 no.1
    • /
    • pp.49-53
    • /
    • 2023
  • Juvenile ossifying fibroma (JOF) is a variant of the ossifying fibroma and includes two histopathological subtypes: trabecular and psammomatoid. Psammomatoid JOF (PJOF) in craniofacial structures should be distinguished from other fibro-osseous lesions, such as fibrous dysplasia (FD), considering the difference in the treatment protocols. Here, we present a rare case of PJOF that was initially misdiagnosed as a case of FD and emphasize the importance of considering JOF in the differential diagnosis of patients with craniofacial fibro-osseous lesions. A 4-year-old boy demonstrated progressive enlargement of the zygomaticomaxillary area on his left side for the last 6 months. The patient was diagnosed as a case of FD based on the clinical features and radiographic findings, and was operated considering the rapid progression. To achieve facial symmetry, contouring of the zygomatic bone and arch was performed. However, the patient demonstrated rapid enlargement at the 3-month postoperative follow-up. The decision was made to surgically remove the tumor due to visual field impairment. Intraoperatively, a rubbery mass, which was separated from the surrounding cortical bone, was identified and excised. The lesion was confirmed as PJOF by histopathological examination. The possibility of PJOF should not be ruled out in the differential diagnosis of patients with fibrous-osseous lesions. In the event of suspected PJOF, accurate diagnosis should be made through definitive biopsy.

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

Semiautomatic Three-Dimensional Threshold-Based Cardiac Computed Tomography Ventricular Volumetry in Repaired Tetralogy of Fallot: Comparison with Cardiac Magnetic Resonance Imaging

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.102-113
    • /
    • 2019
  • Objective: To assess the accuracy and potential bias of computed tomography (CT) ventricular volumetry using semiautomatic three-dimensional (3D) threshold-based segmentation in repaired tetralogy of Fallot, and to compare them to those of two-dimensional (2D) magnetic resonance imaging (MRI). Materials and Methods: This retrospective study evaluated 32 patients with repaired tetralogy of Fallot who had undergone both cardiac CT and MRI within 3 years. For ventricular volumetry, semiautomatic 3D threshold-based segmentation was used in CT, while a manual simplified contouring 2D method was used in MRI. The indexed ventricular volumes were compared between CT and MRI. The indexed ventricular stroke volumes were compared with the indexed arterial stroke volumes measured using phase-contrast MRI. The mean differences and degrees of agreement in the indexed ventricular and stroke volumes were evaluated using Bland-Altman analysis. Results: The indexed end-systolic (ES) volumes showed no significant difference between CT and MRI (p > 0.05), while the indexed end-diastolic (ED) volumes were significantly larger on CT than on MRI (93.6 ± 17.5 mL/m2 vs. 87.3 ± 15.5 mL/m2 for the left ventricle [p < 0.001] and 177.2 ± 39.5 mL/m2 vs. 161.7 ± 33.1 mL/m2 for the right ventricle [p < 0.001], respectively). The mean differences between CT and MRI were smaller for the indexed ES volumes (2.0-2.5 mL/m2) than for the indexed ED volumes (6.3-15.5 mL/m2). CT overestimated the stroke volumes by 14-16%. With phase-contrast MRI as a reference, CT (7.2-14.3 mL/m2) showed greater mean differences in the indexed stroke volumes than did MRI (0.8-3.3 mL/m2; p < 0.005). Conclusion: Compared to 2D MRI, CT ventricular volumetry using semiautomatic 3D threshold-based segmentation provides comparable ES volumes, but overestimates the ED and stroke volumes in patients with repaired tetralogy of Fallot.

Sonographic observation of the paradoxical masseteric bulging and clinical implication of functional compartment

  • Kyu-Ho Yi;Hyungkyu Bae;Soo-Bin Kim;Woo-Ram Kim;Won Lee;Ji-Soo Kim;Hee-Jin Kim
    • Anatomy and Cell Biology
    • /
    • v.57 no.1
    • /
    • pp.13-17
    • /
    • 2024
  • Masseter are commonly botulinum neurotoxin targeted muscle for facial contouring in aesthetic field. However, paradoxical masseteric bulging is common adverse effect that has not been discussed with ultrasonographic observations. Retrospective study has been conducted from October, 2021 to January, 2023, out of 324 patients have done blinded botulinum neurotoxin injection in the masseter at the middle and lower portion of the masseter with each side of 25 units (letibotulinum neurotoxin type A), 3 patients demonstrated paradoxical masseteric bulging has been reported and the image observed by ultrasonography by physician. Based on the observations made, we can infer that the function of the moving muscle involves twisting of the muscle fibers during contraction, along with the twisting of the deep inferior tendon, which causes the muscle to be divided into anterior and posterior compartments rather than into superficial and deep compartments of masseter. In ultrasonographic observe the skin surface of a patient with paradoxical masseteric bulging, it is observable that either the anterior or posterior part contracts significantly. The functional units of anterior and posterior compartment are observable as muscular contraction of inward movement of the muscle from either the anterior or posterior functional unit.

The evaluation for the usability ofthe Varian Standard Couch modelingusing Treatment Planning System (치료계획 시스템을 이용한 Varian Standard Couch 모델링의 유용성 평가)

  • Yang, yong mo;Song, yong min;Kim, jin man;Choi, ji min;Choi, byeung gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.77-86
    • /
    • 2016
  • Purpose : When a radiation treatment, there is an attenuation by Carbon Fiber Couch. In this study, we tried to evaluate the usability of the Varian Standard Couch(VSC) by modeling with Treatment Planning System (TPS) Materials and Methods : VSC was scanned by CBCT(Cone Beam Computed Tomography) of the Linac(Clinac IX, VARIAN, USA), following the three conditions of VSC, Side Rail OutGrid(SROG), Side Rail InGrid(SRIG), Side Rail In OutSpine Down Bar(SRIOS). After scan, the data was transferred to TPS and modeled by contouring Side Rail, Side Bar Upper, Side Bar Lower, Spine Down Bar automatically. We scanned the Cheese Phantom(Middelton, USA) using Computed Tomography(Light Speed RT 16, GE, USA) and transfer the data to TPS, and apply VSC modeled previously with TPS to it. Dose was measured at the isocenter of Ion Chamber(A1SL, Standard imaging, USA) in Cheese Phantom using 4 and 10 MV radiation for every $5^{\circ}$ gantry angle in a different filed size($3{\times}3cm^2$, $10{\times}10cm^2$) without any change of MU(=100), and then we compared the calculated dose and measured dose. Also we included dose at the $127^{\circ}$ in SRIG to compare the attenuation by Side Bar Upper. Results : The density of VSC by CBCT in TPS was $0.9g/cm^3$, and in the case of Spine Down Bar, it was $0.7g/cm^3$. The radiation was attenuated by 17.49%, 16.49%, 8.54%, and 7.59% at the Side Rail, Side Bar Upper, Side Bar Lower, and Spine Down Bar. For the accuracy of modeling, calculated dose and measured dose were compared. The average error was 1.13% and the maximum error was 1.98% at the $170^{\circ}beam$ crossing the Spine Down Bar. Conclusion : To evaluate the usability for the VSC modeled by TPS, the maximum error was 1.98% as a result of compassion between calculated dose and measured dose. We found out that VSC modeling helped expect the dose, so we think that it will be helpful for the more accurate treatment.

  • PDF

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.