• Title/Summary/Keyword: Continuous wall

Search Result 305, Processing Time 0.033 seconds

A Study on the Behavior and Heat Transfer Characteristics of Impinging Sprays

  • Yang, Hei-Cheon;Park, Sang-Kyoo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.374-383
    • /
    • 2001
  • The spray/wall interaction is considered as an important phenomenon influencing air-fuel mixing in the internal combustion engines. In order to adequately represent the spray/wall interaction process, impingement regimes and post-impingement behavior have been modeled using experimental data and conservation constraints. The modeled regimes were stick, rebound, spread and splash. The tangential velocities of splashing droplets were obtained using a theoretical relationship. The continuous phase was modeled using the Eulerian conservation equations, and the dispersed phase was calculated using a discrete droplet model. The numerical simulations were compared to experimental results for spray impingement normal to the wall. The predictions for the secondary droplet velocities and droplet sizes were in good agreement with the experimental data.

  • PDF

Development of prediction model for pressure loss and cut-size of cyclone separator depend on wall curvature (사이클론 집진기의 벽면구배에 따른 압력손실과 컷-사이즈 변화 예측 모델 개발)

  • Heo, Kwang-Su;Seol, Seoung-Yun
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2676-2681
    • /
    • 2008
  • In previous studies, Convex cyclone are proposed to reduce pressure loss which are design cyclone wall with a single continuous curve. Studies about a prediction model for pressure loss and cut-size has focused on conventional cylinder-on-con cyclone. Therefore, the models do not perform well for uncommon design. In this study, a predict model for pressure loss and cut-size depend on cyclone wall curvature are developed. The tangential velocity below vortex-finder is obtained with consideration about friction area and momentum loss on the cyclone wall, and with this the variation of vortex-core and core velocity is obtained. Pressure loss is predicted using a Rankine vortex hypothesis. The prediction results are well agreed with experiments and CFD results.

  • PDF

Continuous Curing and Residual Stresses of Thick Composite Cylinders (두꺼운 복합재료 실린더의 생산 및 열응력 해석)

  • Kim, Cheol
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.49-52
    • /
    • 2000
  • A new composite manufacturing technique which combines winding and curing together is studied and analyzed. This method is especially suited to the manufacture of thick composite materials in which thermal spiking is a common problem. An experimental apparatus was designed and built for use with a filament winder to continuously cure a thick composite cylinder. A hoop-wound composite cylinder with 152 mm wall thickness was manufactured and embedded thermocouples and strain gages were monitored throughout the cure process. The experimental data were compared with analytical results.

  • PDF

APPLICATION OF WIRELESS INCLINOMETER FOR DISPLACEMENT MEASUREMENT OF TEMPORARY EARTH RETAINING PILE

  • Chi Hun In;Hong Chul Rhim
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.218-223
    • /
    • 2009
  • During the process of excavation for substructures of buildings, precise and constant measurements of retaining wall displacement is crucial for construction to be complete and safe. Currently an inclinometer is used to measure displacement around the perimeter of an excavation site. The existing inclinometer system requires an instrument to be placed inside pre-bored holes for each measurement with an typical interval of two weeks. This makes it difficult to obtain continuous displacement data, especially during a critical time such as rainy season in summer. Also, the existing inclinometer is placed at certain distance away from the retaining wall system itself. Thus, exact measurement of retaining wall movement is compromised because of the distance between the retaining wall and the inclinometer. This paper presents the development of wireless inclinometer system for the displacement measurement of retaining walls by being attached directly to the retaining wall. The result of the application of the developed systems are provided with advanced ubiquitous sensor network (USN) system features. The USN technique incorporated into the system enables users to monitor movement data from wherever possible and convenient such as construction manager's office on site or any other places connected through internet. The research work presented in this paper will provide a basis to save construction time and cost by preventing safe-related unexpected delay of construction due to the failure or collapse of retaining walls.

  • PDF

A Numerical Study on the Flow Fields in the Continuous Casting Mold with Electromagnetic Brake (EMBR이 적용된 연속주조 몰드 내부에서의 유동장 해석)

  • Ha M. Y.;Lee H. G.
    • Journal of computational fluids engineering
    • /
    • v.4 no.2
    • /
    • pp.47-56
    • /
    • 1999
  • We developed a computer program to simulate the flow field in the presence of electro-magnetic fields. The steady, two-dimensional conservation equations for mass and momentum were solved simultaneously with Maxwell equations for electro-magnetic fields. Using this program, a numerical analysis was carried out to analyze the fluid flow in the continuous casting mold with electromagnetic brake. The effects of magnetic fields size, nozzle angle and EMBR yoke position on the flow fields in the continuous casting were investigated in the present study. The flow fields with EMBR were compared with those without EMBR. We also investigated the distribution of tracer concentration as a function of time in order to calculate their residence time in the mold with EMBR. By controlling the flow fields properly using EMBR, we can prevent the direct flow impaction on the wall which can give a damage on the mold surface and reduce surface defects of stainless steel sheet products.

  • PDF

Ice Marking Pattern of Flowing Organic Water Solution in a Horizontal Cooled Tube (수평냉각관내에서 유동하는 유기수용액의 제빙형태)

  • 박기원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.52-57
    • /
    • 2000
  • Recently large capacity of electric equipment and increasing in atomic power generation are shown. One of the reason is shortage of the electric power supply for air conditioning load during summer. And every consumer is concerning about economical refrigeration and air conditioning system to decreases electric power consumption and decrease in global warming. For these necessities, ice making thermal storage system is required. Therefore, in this paper, the possibility of continuous slurry ice making using flowing organic water solution in cooled circular tube has been investigated. The experiments was carried out under some parameters of concentration and velocity of water solution, temperature of cooled tube wall, and control pressure in tube, As a result, four types of operating conditions in the pipe, that was supercooling, continuous ice making, intermittent ice making and ice blockage, were classified . And it was found that the critical condition for continuous ice making was acquired as a function of these experimental parameters.

  • PDF

Continuous Overlap Pile by Using Concrete Guide for Soil Sheeting Works (콘크리트 가이드를 이용한 흙막이용 겹침연속말뚝)

  • Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.12-13
    • /
    • 2021
  • As construction projects are gradually getting larger and focusing on building skyscraper with the development of construction technology and the concentration of population in cities, the choice of the soil sheeting works is very important in terms of securing safety and economic feasibility. Further research is planned on the developed concrete guide-based continuous over lap pile method through the introduction of a system that automates vertical management, continuous improvement and supplementation so that the basement soil sheeting wall can be utilized as a building structure.

  • PDF

The Treatment of Massive Spontaneous Subcutaneous Emphysema by Multiple Intravenous Catheter and Continuous Suction Drainage (다수의 정맥용 도관의 피하삽입과 지속흡인을 이용한 다량의 자발성 피하공기증 치료 1예)

  • Kim, Sun Young;Uom, Kwang Seok;Lee, Young Seok;Huh, Kyung Rim;Kwon, Chin Woo;Jang, Seung Hun;Kim, Dong Gyu;Jung, Ki Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.178-183
    • /
    • 2006
  • A-61-year-old COPD patient was hospitalized due to dyspnea and was diagnosed with acute exacerbation of COPD. During the hospital stay, the patient's dyspnea was aggravated by massive spontaneous subcutaneous emphysema. Multiple 16 gauge intravenous catheters were inserted at the midclavicular line for drainage. Although subcutaneous catheter drainage was carried out, respiratory failure developed with an increased in massive subcutaneous emphysema. Continuous suction drainage with wall suction was applied resulting in the rapid resolution of the subcutaneous emphysema. We report a case of the that effective management of massive subcutaneous emphysema using multiple 16 gauge intravenous catheters with continuous suction.

Structural Health Monitoring of Nuclear Containment Building Using Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 원자력발전소 격납건물의 구조 건전성 계측)

  • Lee, Seung-Hwan;Lee, Nam-Kwon;Lee, Geum-Seok;Lee, Hong-Pyo;Yu, Yun-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.71-75
    • /
    • 2013
  • Nuclear containment building is used as second blockage to protect us from a radiation leakage caused by the natural disaster or any accidents, so it's safety is important and must be kept with continuous surveillance. In this study, we measured the strain of a nuclear containment building's wall by using FBG sensor and investigated the structural safety of a nuclear containment building. 50 FBG strain sensors and 18 FBG strain sensors were attached on the side wall and upper dome of a nuclear containment building, respectively. We measured the strains of the outside concrete wall during the Structural Integrity Test (SIT) of a nuclear containment building. The strain of an upper dome was larger than that of a side wall, about $200{\mu}{\varepsilon}$. And the very small strain was measured at vertical direction of a side wall. These experimental results were used to evaluate the structural health of nuclear containment building.

A Dual-Band Through-the-Wall Imaging Radar Receiver Using a Reconfigurable High-Pass Filter

  • Kim, Duksoo;Kim, Byungjoon;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.3
    • /
    • pp.164-168
    • /
    • 2016
  • A dual-band through-the-wall imaging radar receiver for a frequency-modulated continuous-wave radar system was designed and fabricated. The operating frequency bands of the receiver are S-band (2-4 GHz) and X-band (8-12 GHz). If the target is behind a wall, wall-reflected waves are rejected by a reconfigurable $G_m-C$ high-pass filter. The filter is designed using a high-order admittance synthesis method, and consists of transconductor circuits and capacitors. The cutoff frequency of the filter can be tuned by changing the reference current. The receiver system is fabricated on a printed circuit board using commercial devices. Measurements show 44.3 dB gain and 3.7 dB noise figure for the S-band input, and 58 dB gain and 3.02 dB noise figure for the X-band input. The cutoff frequency of the filter can be tuned from 0.7 MHz to 2.4 MHz.