심실의 부하감소 측면에서 좌심실 보조장치의 최적 치료시기 예측을 위한 시뮬레이션 연구 (Prediction of Pumping Efficacy of Left Ventricular Assist Device according to the Severity of Heart Failure: Simulation Study)

  • 김은혜;임기무
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.22-28
    • /
    • 2013
  • It is important to begin left ventricular assist device (LVAD) treatment at appropriate time for heart failure patients who expect cardiac recovery after the therapy. In order to predict the optimal timing of LVAD implantation, we predicted pumping efficacy of LVAD according to the severity of heart failure theoretically. We used LVAD-implanted cardiovascular system model which consist of 8 Windkessel compartments for the simulation study. The time-varying compliance theory was used to simulate ventricular pumping function in the model. The ventricular systolic dysfunction was implemented by increasing the end-systolic ventricular compliance. Using the mathematical model, we predicted cardiac responses such as left ventricular peak pressure, cardiac output, ejection fraction, and stroke work according to the severity of ventricular systolic dysfunction under the treatments of continuous and pulsatile LVAD. Left ventricular peak pressure, which indicates the ventricular loading condition, decreased maximally at the 1st level heart-failure under pulsatile LVAD therapy and 2nd level heart-failure under continuous LVAD therapy. We conclude that optimal timing for pulsatile LVAD treatment is 1st level heart-failure and for continuous LVAD treatment is 2nd level heart-failure when considering LVAD treatment as "bridge to recovery".

등온열처리와 냉각에 따른 $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) 초전도체의 상변화 (Phase transformation of $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) Superconductor during Continuous Cooling and Isothermal Heat Treatment)

  • 오용택;신동찬;한영희;성태현;정년호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.42-45
    • /
    • 2003
  • The phase transformation of $REBa_2Cu_3O_{7-x}$ (RE=Nd, Gd, Dy) was investigated using isothermal heat-treatment and continuous cooling in air. During continuous cooling, the $REBa_2Cu_3O_{7-x}$ (RE=123) superconducting phase with well-distributed $REBa_2Cu_3O_{7-x}$ (RE-211) was obtainde at a cooling rate of $0.001^{\circ}C$/s. Single phase RE-123 (Nd, Gd, Dy) was stable at $1050^{\circ}C$, $1050^{\circ}C$, and $950^{\circ}C$ during isothermal heat-treatment, respectively. Above these temperatures the RE-211 phase existed within the RE-123 grains. The RE-123, RE-211, $BaCu_2Od_2$, and CuO phases coexisted at $50^{\circ}C$ below the partial melting temperature for each respective rare-earth RE-123.

  • PDF

The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System

  • DEDE SAGSOZ, Yesim;YILMAZ, Alper Erdem;EKMEKYAPAR TORUN, Fatma;KOCADAGISTAN, Beyhan;KUL, Sinan
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.261-268
    • /
    • 2022
  • In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 μS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.

복합조직강의 연속어닐링과정에서 미세조직과 집합조직의 변화 (Change in Microstructure and Texture during Continuous-Annealing in Dual-Phase Steels)

  • 정우창
    • 열처리공학회지
    • /
    • 제28권4호
    • /
    • pp.171-180
    • /
    • 2015
  • The variation in microstructure and texture during continuous annealing was examined in a series of 1.6% Mn-0.1% Cr-0.3% Mo-0.005% B steels with carbon contents in the range of 0.010 to 0.030%. It was found that microstructure of hot band consisted of ferrite and pearlite as a consequence of high coiling temperature, and eutectoid carbon content was between 0.011% and 0.016%. Martensite ranged in volume fraction from 1.5% to 4.0% when annealed at $820{\circ}C$ according to the typical continuous annealing cycle. The critical martensite content for the continuous yielding was about 4% from stress-strain curves. The continuous yielding was obtained in the 0.030% carbon steel and 0.010% to 0.020% carbon steels revealed some yield point elongation ranging from 0.8% to 2.2% in as-annealed conditions. Higher tensile strength in the higher carbon steel is due to both increase in the martensite volume fraction and ferrite grain refinement. Decreasing the carbon content to 0.01% strengthened the intensities of ${\gamma}$-fiber textures, resulting in the increase in the $r_m$ value, which was caused by the lower volume fraction of martensite. The higher carbon steels showed the lower $r_m$ value of about 1.0.

Fatal Rhabdomyolysis in a Patient with Head Injury

  • Park, Yong Jin;Kim, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권5호
    • /
    • pp.303-304
    • /
    • 2013
  • Rhabdomyolysis is a rare but potentially life-threatening disorder caused by the release of injured skeletal muscle components into the circulation. The authors report a case of severe head injury, in which a hyperosmolar state and continuous seizure complicated by severe rhabdomyolysis and acute renal failure evolved during the course of treatment resulted in a fatal outcome despite intensive supportive treatment. Our bitter experience suggests that rhabdomyolysis should be born in mind in patients with severe head injury who may develop hyperosmolar state and continuous seizure.

희염약침자극이 자발성(自發性) 고혈압(高血壓) 흰쥐의 혈압(血壓)에 미치는 영향(影響) 및 강압기전(降壓機轉)에 대(對)한 연구(硏究) (A study on the antihypertensive effect and mechanism of Siegesbeckia pubescens aqua-acupuncture treatment in spontaneously hypertensive rats)

  • 남상수;박동석
    • 대한한의학회지
    • /
    • 제18권1호
    • /
    • pp.218-237
    • /
    • 1997
  • In order to investigate the antihypertentive effects and its mechanism of the Siegesbeckia pubescens aqua-acupuncture treatment, experiments were performed on immediate and continuous antihypertensive effects, vasodilatation-autonomic nerve block, diuretic activity, and angiotensin converting enzyme inhibitory activity. The results were as follows; 1. Acupuncture treatment group showed significantly immediate antihypertensive effects in 4 hours after treatment. Normal saline aqua-acupuncture treatment group showed significantly immediate antihypertensive effects in 2, 4 and 6 hours after treatment. Siegesbeckia pubescens aqua-acupuncture treatment group showed significantly immediate antihypertensive effects in 30 minutes, 1, 2, 4 and 6 hours after treatment. 2. Siegesbeckia pubescens aqua-acupuncture treatment group showed significantly continuous antihypertensive effects in 6, 8, 9 and 10 days after treatment. 3. Siegesbeckia pubescens aqua-acupuncture extract solution showed significantly vasodilatatory and sympathetic nerve block effects with concentration of $10^{-6},\;10^{-5},\;10^{-4},\;10^{-3}g/m{\ell}$. 4. Oral administration group of the Siegesbeckia pubescens aqua-acupuncture extract solution didn't show no significantly diuretic effects. 5. Siegesbeckia pubescens aqua-acupuncture extract solution showed 28.8% angiotensin converting enzyme inhibitory activity.

  • PDF

열처리 조건에 따른 주철연속주조봉의 미세조직 변화 (The Microstructure Changes of Continuous Cast iron Rods According to the Heat-Treatment Conditions)

  • 김태봉;김선화;박상준
    • 한국주조공학회지
    • /
    • 제20권3호
    • /
    • pp.173-180
    • /
    • 2000
  • The microstructure changes of the matrix and the graphites were observed by optical microscope and the average hardness number was investigated according to the heat-treatment conditions of the cast iron rods by the horizontal continuous casting process in 35 mm diameter. The three kinds of heat-treatments were introduced. The first treatment was performed at 900, 950, and $1000^{\circ}C$ for 2 hours and the second treatment was conducted during 5, 10, and 15 hours at $1000^{\circ}C$ respectively. The third treatments were the two-cyclic heat-treatment and the three-cyclic heat-treatment at $1000^{\circ}C$ during 2 hours. The matrix microstructure of the specimens to be treated at various temperatures for 2 hours was the ferrite to be transformed from the pearlite The hardness number of the center of the samples according to the heat treatment time at $1000^{\circ}C$ was higher than that of the surface area because of the martensite formation in the center. Also, in the cyclic heat-treatments, the hardness number of the two-cycle treatment specimens increased because of the martensite formation in the center.

  • PDF

SM45C강의 연속파 Nd:YAG레이저표면경화와 고주파표면경화특성 비교 (Comparison of Characteristics on Induction and Continuous Nd:YAG Laser Surface hardening of SM45C Steel)

  • 신호준;유영태;안동규;신병헌
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.176-183
    • /
    • 2005
  • Laser heat treatment technology is used for improving the feature of fatigue resistance and wear resistance in mobile parts. The purpose of this study is to compare the characteristics of laser heat treatment and high frequency heat treatment, which is commonly used in industrial place. For the preemptive experiment, the distribution, depth and size of hardening and its micro-structural features were compared between surface heat treatment case by defocusing and variables of each process for heat treatment by exclusively manufactured heat treatment optical system. As a result, high frequency heat treatment has wide distribution of hardening depth and width about 3 times larger than laser heat treatment, however, its average hardness showed 621.4Hv which is smaller than the average hardness of laser heat treatment with 691Hv.

  • PDF

미세조류를 이용한 질소제거 장치의 크기 (Size Estimation of Microalgal System for Nitrogen Removal)

  • 김한욱;이우성;이철균
    • KSBB Journal
    • /
    • 제19권3호
    • /
    • pp.236-240
    • /
    • 2004
  • Batch experiment에서 다양한 질소 농도에서 구해진 질소제거 속도와 비 생장속도 등의 데이터를 토대로 4.6일의 체류시간을 갖는 2단 처리 장치를 설계하였다. 그리고 continuous experiments에서는 3.5일의 체류시간을 갖는 2단의 처리 장치를 설계하였다. 두 가지 값에 차이는 있지만 실제 현장에서 폐수 처리 장치를 설계할 때 충분한 자료가 되리라고 판단한다. 따라서 위의 결과를 토대로 기존 시스템에 미세조류 시스템을 부가한다면 기존공정의 단점인 잉여질소 제거 장치로서 충분히 역할을 수행해 배출 기준치를 만족시키는 안전한 폐수처리장치가 되리라고 판단한다.

Bayesian Network Model to Evaluate the Effectiveness of Continuous Positive Airway Pressure Treatment of Sleep Apnea

  • Ryynanen, Olli-Pekka;Leppanen, Timo;Kekolahti, Pekka;Mervaala, Esa;Toyras, Juha
    • Healthcare Informatics Research
    • /
    • 제24권4호
    • /
    • pp.346-358
    • /
    • 2018
  • Objectives: The association between obstructive sleep apnea (OSA) and mortality or serious cardiovascular events over a long period of time is not clearly understood. The aim of this observational study was to estimate the clinical effectiveness of continuous positive airway pressure (CPAP) treatment on an outcome variable combining mortality, acute myocardial infarction (AMI), and cerebrovascular insult (CVI) during a follow-up period of 15.5 years ($186{\pm}58$ months). Methods: The data set consisted of 978 patients with an apnea-hypopnea index (AHI) ${\geq}5.0$. One-third had used CPAP treatment. For the first time, a data-driven causal Bayesian network (DDBN) and a hypothesis-driven causal Bayesian network (HDBN) were used to investigate the effectiveness of CPAP. Results: In the DDBN, coronary heart disease (CHD), congestive heart failure (CHF), and diuretic use were directly associated with the outcome variable. Sleep apnea parameters and CPAP treatment had no direct association with the outcome variable. In the HDBN, CPAP treatment showed an average improvement of 5.3 percentage points in the outcome. The greatest improvement was seen in patients aged ${\leq}55$ years. The effect of CPAP treatment was weaker in older patients (>55 years) and in patients with CHD. In CHF patients, CPAP treatment was associated with an increased risk of mortality, AMI, or CVI. Conclusions: The effectiveness of CPAP is modest in younger patients. Long-term effectiveness is limited in older patients and in patients with heart disease (CHD or CHF).