• Title/Summary/Keyword: Continuous operation

Search Result 1,713, Processing Time 0.025 seconds

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

Separation of Hydrocarbon Mixture Using (O/W)/O Emulsion Liquid Membrane ((O/W)/O 에멀젼형 액막을 이용한 탄화수소 혼합물의 분리)

  • Jeong, M.C.;Park, H.Y.;Oh, J.T.;Kim, J.K.;Shin, M.H.;Kim, W.S.
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.763-770
    • /
    • 1997
  • The separation of benzene-cyclohexane mixture using (O/W)/O emulsion liquid membrane was studied. The operating parameters which can affect the selectivity, benzene yield, and emulsion size distribution were examined and determined by the batch type operation. The unsteady state and steady state extraction behavior in continuous pulse stirred reactor(CPSR) were verified. The optimum conditions for benzene selectivity and yield in batch operation were as follows; emulsion mixing intensity 4000 rpm, Tween 80 concentration 0.4%, volume ratio of membrane phase to internal phase 0.75, volume ratio of dispersed phase to continuous phase 0.5, and permeation time 10 minutes, As impeller speed increased and the microdrop holdup decreased, the Sauter mean diameter decreased. Turbulence damping parameter of modified Calabrease correlation considering microdrop holdup was 2.28. The optimum conditions of continuous operation were as follows; agitation speed 300 rpm, pulse frequence 2 times/sec, flow rate of continuous phase 30ml/min, and flow rate of emulsion phase 12.0ml/min.

  • PDF

Analysis of Factor Hindering and Promotion Strategy on the Direct Marketing of Agricultural Products (농산물 직거래 유통채널별 저해요인 분석과 활성화 방안)

  • Kim, Deok-Hyeon;Park, Gil-Seog;Lee, Su-Young;Lee, Seung-Hyun
    • Journal of Distribution Science
    • /
    • v.14 no.12
    • /
    • pp.71-78
    • /
    • 2016
  • Purpose - This paper is for the Analysis on the Hindrance Factors and Activation Scheme by the Type of Distribution Channel in Direct transaction of Agricultural Products. As the distribution structure of agricultural products has become changable, farmers seem to use the type of direct distribution in order to enhance the receiving price. This study aims to explore the hindrance factors and income variation rate in direct transaction of agricultural produces, specifically focusing on the 167 farmers. Research design, data, and methodology - To ascertain the hindrance factors exactly by the type of distribution channel, the managements were classified by four subcategories, that is high sales percentage with shopping malls, SNS, shopping malls and SNS, and off-line direct transaction. Results - As a result of the hypothesis test, hinderance factors in online direct deal activation were found to be in the order of the difficulty in continuous content production, the difficulty in shopping mall operation and maintenance, and the difficulty in card commission problems, and in the order of the difficulties in continuous content production, the difficulty in continuous content production, the difficulty in shopping mall operation and maintenance, and the difficulty in branding for the SNS group. Thus, it can be seen that the difficulty in continuous content production, shopping mall operation and maintenance were found to be the biggest obstacles. In addition, hindering factors in online direct deal activation were found to be in the order of the difficulty in credit card settlement, the difficulty in publicity, and the difficulty in dealing with unsold goods. The group with high sales rate in shopping mall was found to be increased by 23.9% in the gross income compared to the previous year, the group with high SNS sales ratio increased by 56.5%, the group with direct offline transaction increased by 37.1%, among which the group with the highest increase rate of SNS sales ratio was found to be the highest from the rate of increase/decrease of the income, which was statistically significant. Conclusions - It can be suggested that government and local government may provide agricultural management with supporting plan which in turn can activate direct transaction in any possible ways.

Removal Characteristics of Styrene Vapor in the Biofilter Packed with Loess/Polyurethane Composite Media (황토/폴리우레탄 복합담체를 충전한 Biofilter에서 기상 Styrene의 제거특성)

  • Kang Kyung-Ho;Kam Sang-Kyu;Lee Taek-Kwan;Lim Sang-Bin;Lee Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.14 no.11
    • /
    • pp.1027-1033
    • /
    • 2005
  • The treatment of styrene vapor was carried out using the biofilter packed with loess/polyurethane composite during continuous operation of 74 days. The microorganisms were adapted within 2-3 days under the experimental conditions of inlet concentration and empty bed contact time (EBCT). At 200 sec of EBCT, the removal efficiency of styrene was 100\% with 200 ppmv of inlet concentration, while $92\%$ with 400 ppmv of inlet concentration. The biofilter showed the stable removal efficiencies of over $74\%$ under the EBCT range from 300 to 75 sec at the 150 ppmv of inlet styrene concentration. The maximum capacity of styrene removal for the biofilter packed with loess/polyurethane was $29g/m^3/hr$. During continuous operation of 74 days, pH of the drain water changed slightly and the pressure drop through the biofilter column was below $45\;mmH_2O/m$.

Level Dynamics and Control of the Solution in the High Temperature Generator of an Absorption Chiller (흡수식 냉온수기 고온재생기 액면 거동과 제어)

  • Shin, Young-Gy;Kwak, Min-Soo;Cho, Hyun-Wook;Nam, Sang-Chul;Jeong, Jin-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.852-858
    • /
    • 2010
  • In an absorption chiller, solution is circulated by a solution pump with an inverter to vary flow rate depending on operating conditions. For optimal operation, the solution level in the high temperature generator should be kept constant. However, a sensor for measuring continuous level is not available because of varying solution concentration. Instead, level switches are used and hence feedforward control associated with limit checking is a common practice. In the study, inverter frequencies are estimated from a dynamic simulation model and pump performance. Designed frequencies are compared with those implemented in real chillers. It was found that the frequencies used in real chillers are larger than those needed in circulation flow rates. It was intended to prevent system shut-off caused by dry-out. However, it is necessary to minimize the excessive frequency setting in order to reduce frequent pump stops and the range of solution level for continuous pump operation.

Gasification Characteristics of Rice Husks in Batch Operation (배치공정에서 왕겨가스화 특성)

  • Kim, Y.J.;Kang, Y.K.;Ryou, Y.S.;Kang, G.C.;Paek, Y.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.248-252
    • /
    • 2008
  • An experiment was conducted in order to investigate gasification characteristics of rice husks in a fixed bed, which was a pre-step to design a continuous gasification system. Two air supply levels for gasification were chosen and their effects on the producer gas amount and producer gas composition were discussed. The main components of the producer gas were CO, $CO_2$, $O_2$, $H_2$ and THC (Total HydroCarbon). As airflow rate decreased, more producer gas was produced. The peak amount of CO, $H_2$ and THC were 28%, 7.5% and 0.68% in volume when constant airflow rate of $3.36\;m^3/s$ was used in the batch operation. About 4.5 kg of ash (9%) and condensed water including tars of 6 kg (11%) were produced from 50 kg rice husks in the gasification. Excluding the byproducts, all rice husks seemed to be transformed into producer gas. This gasification study was conducted prior to developing a continuous gasification system for biomass including agricultural byproducts.

Theoretical Analysis of Digital PLL (디지털 위상 고정 루프의 이론적 해석)

  • 박영철;김재형;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.5
    • /
    • pp.460-471
    • /
    • 1992
  • By setting a new model to describe the time-discontinuous operation of PLL loop which used tri-state and sample-hold method, the stability analysis of nonlinear PLL has been performed in z-domain and the state equations for the transient response has been introduced. Until now, the lin-ear analysis by approximation of time-discontinuous to time-continuous operation had not found then stable region of time-discontinuous digital PLL exactly. However, the analysis In z-domain by the new model has been found the unstable region where the time-continuous analysis had have not. 1'herefore the limit of loop coefficient has been computed to design digital PLL optimally.

  • PDF

Surgical treatment of the disease involving ascending aorta (상행 대동맥 질환의 외과적 치료)

  • 백완기
    • Journal of Chest Surgery
    • /
    • v.27 no.7
    • /
    • pp.581-586
    • /
    • 1994
  • From February 1985 to February 1993, 18 operations were performed in 17 patients for treatment of aneurysmal disease [n=12] and/or dissection of the ascending aorta [n=6]. The ages ranged from 26 to 69 years [mean 44.3 $\pm$ 11.0 years].The proposed operations include composite graft replacement of aortic valve and ascending aorta with coronary reimplantation in 11, graft replacement of ascending aorta alone in 5, aortic valve replacement and supracoronary graft replacement in 1 and ascending aorta to abdominal aorta bypass with thromboexclusion of descending aorta in one patient. Both Bentall [n=6] and Cabrol [n=5] technique were utilized for reimplantation of coronary arteries.Concomitant replacement of aortic arch and arch vessel reconstruction was necessary in two patients. Hypothermic circulatory arrest was utilized in 6 patients. Recently, four patients were managed on warm blood continuous cardioplegia via retrograde route. There were no operative deaths. No significant postoperative complications were noted. Postoperative follow up was complete in 15 patients from 1 month to 72 months. Redo operation was necessary in one patient who had suffered from distal recurrence of dissection 5 years after successful Bentall operation. The other patients are all in excellent clinical condition. From our early experience with those 17 cases, we assume that satisfactory operative result could be achieved with a variety of surgical technique including hypothermic circulatory arrest. In addition, continuous perfusion of warm blood cardioplegia via retrograde route is supposed to be beneficial in selected cases.

  • PDF

Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils (3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.3
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.

An Open Circuit Fault Diagnostic Technique in IGBTs for AC to DC Converters Applied in Microgrid Applications

  • Khomfoi, Surin;Sae-Kok, Warachart;Ngamroo, Issarachai
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.801-810
    • /
    • 2011
  • An open circuit fault diagnostic method in IGBTs for the ac to dc converters used in microgrid applications is developed in this paper. An ac to dc converter is a key technology for microgrids in order to interface both distributed generation (DG) and renewable energy resources (RES). Also, highly reliable ac to dc converters are necessary to keep converters in continuous operation as long as possible during power switch fault conditions. Therefore, the proposed fault diagnostic method is developed to reduce the fault detection time and to avoid any other fault alarms because continuous operation is desired. The proposed diagnostic method is a combination of the absolute normalized dc current technique and the false alarm suppression algorithm to overcome the long fault detection time and fault alarm problems. The simulation and experimental results show that the developed fault diagnostic method can perform fault detection within about one cycle. The results illustrate that the reliability of an ac to dc converter interfaced with a microgrid can be improved by using the proposed fault diagnostic method.