• Title/Summary/Keyword: Continuous modulating signal

Search Result 4, Processing Time 0.017 seconds

Reduction of Common Mode Voltage in Asymmetrical Dual Inverter Configuration Using Discontinuous Modulating Signal Based PWM Technique

  • Reddy, M. Harsha Vardhan;Reddy, T. Bramhananda;Reddy, B. Ravindranath;Suryakalavathi, M.
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1524-1532
    • /
    • 2015
  • Conventional space vector pulse width modulation based asymmetrical dual inverter configuration produces high common mode voltage (CMV) variations. This CMV causes the flow of common mode current, which adversely affects the motor bearings and electromagnetic interference of nearby electronic systems. In this study, a simple and generalized carrier based pulse width modulation (PWM) technique is proposed for dual inverter configuration. This simple approach generates various continuous and discontinuous modulating signals based PWM algorithms. With the application of the discontinuous modulating signal based PWM algorithm to the asymmetrical dual inverter configuration, the CMV can be reduced with a slightly improved quality of output voltage. The performance of the continuous and discontinuous modulating signals based PWM algorithms is explored through both theoretical and experimental studies. Results show that the discontinuous modulating signal based PWM algorithm efficiently reduces the CMV and switching losses.

development of Underwater Data Communication System (I) -Echo Signal Transfer System- (수중 데이터 통신 시스템의 개발에 관한 연구 (I) -에코 신호 전송 시스템-)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.284-290
    • /
    • 1999
  • This paper describes a Frequency Shift Keying (FSK) modulator and demodulator and the experimented underwater data ommunication equipment to transfer the analog echo signal in real-time from an underwater vehicle to the mother ship. The system consists of an echo signal transfer unit equipped to the vehicle and an ultrasonic receiver equipped on the ship. The former includes an ultrasonic transceiver unit of 180kHz for echo detection and a continuous wave transmitter of 50kHz with a FSK modulator for echo transmission to the ship. The latter includes an ultrasonic receiver of 50kHz and the FSK demodulator. The results of experiment are as follows. 1. The characteristics of the FSK modulating and demodulating circuits designed with the use of C-MOS IC 4046 was good and confirmed its usefulness in underwater data communication system.2. The prototype ultrasonic transceiver unit shows profitable driving power while the pulse duration was short less than 3 msec, but it was found that the driving power is not sufficient while the long pulse duration or continuous wave is used. The gain of the ultrasonic receiver was 80 dB and the receiving bandwidth 700Hz (at - 3 dB point).3. It was found that the system designed by the author has some possibility to use in underwater echo transfer.4. At the FSK modulator, the widths of voltage and frequency which represent linearity were 3.5 V, 1600Hz, respectively, at the FSK demodulator 2.6 V, 700Hz, respectively.

  • PDF

development of Underwater Data Communication System (I) -Echo Signal Transfer System- (수중 데이터 통신 시스템의 개발에 관한 연구 (I) -에코 신호 전송 시스템-)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.285-285
    • /
    • 1999
  • This paper describes a Frequency Shift Keying (FSK) modulator and demodulator and the experimented underwater data ommunication equipment to transfer the analog echo signal in real-time from an underwater vehicle to the mother ship. The system consists of an echo signal transfer unit equipped to the vehicle and an ultrasonic receiver equipped on the ship. The former includes an ultrasonic transceiver unit of 180kHz for echo detection and a continuous wave transmitter of 50kHz with a FSK modulator for echo transmission to the ship. The latter includes an ultrasonic receiver of 50kHz and the FSK demodulator. The results of experiment are as follows. 1. The characteristics of the FSK modulating and demodulating circuits designed with the use of C-MOS IC 4046 was good and confirmed its usefulness in underwater data communication system.2. The prototype ultrasonic transceiver unit shows profitable driving power while the pulse duration was short less than 3 msec, but it was found that the driving power is not sufficient while the long pulse duration or continuous wave is used. The gain of the ultrasonic receiver was 80 dB and the receiving bandwidth 700Hz (at - 3 dB point).3. It was found that the system designed by the author has some possibility to use in underwater echo transfer.4. At the FSK modulator, the widths of voltage and frequency which represent linearity were 3.5 V, 1600Hz, respectively, at the FSK demodulator 2.6 V, 700Hz, respectively.

Performance evaluation of 80 GHz FMCW Radar for level measurement of cryogenic fluid

  • Mun, J.M.;Lee, J.H.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.56-60
    • /
    • 2021
  • The microwave Radar used for special purposes in the past is being applied in various areas due to the technological advancement and cost reduction, and is particularly applied to autonomous driving in the automobile field. The FMCW (Frequency Modulated Continuous Wave) Radar can acquire level information of liquid in vessel based on the beat frequency obtained by continuously transmitting and receiving signals by modulating the frequency over time. However, for cryogenic fluids with small impedance differences between liquid medium and gas medium, such as liquid nitrogen and liquid hydrogen, it is difficult to apply a typical Radar-based level meter. In this study, we develop an 80 GHz FMCW Radar for level measurement of cryogenic fluids with small impedance differences between media and analyze its characteristics. Here, because of the low intrinsic impedance difference, most of the transmitted signal passes through the liquid nitrogen interface and is reflected at the bottom of the vessel. To solve this problem, a radar measurement algorithm was designed to detect multiple targets and separate the distance signal to the bottom of the vessel in order to estimate the precise position on the liquid nitrogen interface. Thereafter, performance verification experiments were performed according to the liquid nitrogen level using the developed radar level meter.