• Title/Summary/Keyword: Continuous Sensor

Search Result 584, Processing Time 0.044 seconds

Intelligent Control of a Virtual Walking Machine for Virtual Reality Interface (가상현실 대화용 가상걸음 장치의 지능제어)

  • Yoon, Jung-Won;Park, Jang-Woo;Ryu, Je-Ha
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.9
    • /
    • pp.926-934
    • /
    • 2006
  • This paper proposes intelligent control of a virtual walking machine that can generate infinite floor for various surfaces and can provide proprioceptive feedback of walking to a user. This machine allows users to participate in a life-like walking experience in virtual environments with various terrains. The controller of the machine is implemented hierarchically, at low-level for robust actuator control, at mid-level fur platform control to compensate the external forces by foot contact, and at high-level control for generating walking trajectory. The high level controller is suggested to generate continuous walking on an infinite floor for various terrains. For the high level control, each independent platform follows a man foot during the swing phase, while the other platform moves back during single stance phase. During double limb support, two platforms manipulate neutral positions to compensate the offset errors generated by velocity changes. This control can, therefore, satisfy natural walking conditions in any direction. Transition phase between the swing and the stance phases is detected by using simple switch sensor system, while human foot motions are sensed by careful calibration with a magnetic motion tracker attached to the shoe. Experimental results of walking simulations at level ground, slope, and stairs, show that with the proposed machine, a general person can walk naturally on various terrains with safety and without any considerable disturbances. This interface can be applied to various areas such as VR navigations, rehabilitation, and gait analysis.

A Study on the Development of the Position Detection System of Small Vessels for Collision Avoidance (충돌 회피를 위한 소형 선박의 위치 검출 시스템 개발에 관한 연구)

  • Le, Dang-Khanh;Nam, Teak-Kun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.2
    • /
    • pp.202-209
    • /
    • 2014
  • In this paper, a developed device for detecting target's location and avoiding collision is proposed. Velocity and acceleration model of target are derived to estimate target's information, i.e. position, velocity and acceleration considering process and measurement noise. Kalman filtering method applied to the estimation process and its results was confirmed by simulation. The distance measurements system using laser sensor for moving target system is also developed to confirm the effectiveness of the proposed scheme. Experiments to get information of moving target with velocity and acceleration model was executed. The data with filtering and without filtering was compared by experiments. Discontinuous measured data was changed to smooth and continuous data by Kalman filtering. It is confirmed that desired data was obtained by applying proposed scheme. UI for measuring and monitoring the target data is developed and visual and auditory alarm function is attached on the system Finally, position estimation system of moving target with good performance is achieved by low price equipments.

The Study of DoA Estimation in Frequency Domain in Automotive Radar System (차량용 레이더 시스템에서 주파수 영역의 도래각 추정 기법에 관한 연구)

  • Choi, Jung-hwan;Choi, Ji-won;Kim, Seong-cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.1
    • /
    • pp.12-22
    • /
    • 2016
  • Convenience and safety are the key words for the automotive driving and various sensor technologies have been studied for enhanced perception of driving environments. In frequency modulated continuous wave (FMCW) radar systems, single antenna is enough for range and velocity detection of multiple targets. Multiple array antenna is needed for estimating direction of arrival(DoA). Using DoA estimation algorithm in time domain as in the conventional systems, it is difficult to distinguish vehicles lie in the same angle. In order to facilitate the enhanced angle estimation, DoA estimation algorithm is applied in frequency domain. In this paper, the method for applying multiple signal classification(MUSIC) algorithm in frequency domain is suggested and the performance is analyzed.

Ultrasonic Transducer Application for Nondestructive Testing of Continuous Cast Billets (연주빌렛의 비파괴 검사를 위한 초음파 센서의 응용)

  • Shin, Byoung-Chul;Kwon, Jeong-Rock
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.25-31
    • /
    • 1996
  • Steel wires are made by elongating hot billets. If the billets have internal or surface defects, the wire can be broken during elongation process. After testing surface defect, we are testing internal defect by ultrasonic transducers. POSCO is producing two kinds of billets, hot rolled billet and cast billet. Hot rolled one is denser than cast billet. Because of the low density and rough surface, ultrasonic testing is difficult for the cast billet. Size of the transducer was related with the size and density of the billet. A transducer having 21mm long, 8.5mm wide and 0.95mm thick piezoelectric ceramic plate was best for $160mm\;{\times}\;160mm$ cast billet. Center frequency of the transducer was 2.25MHz and the focus distance was 70mm.

  • PDF

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.

THE DESIGN OF DGPS/INS INTEGRATION FOR IMPLEMENTATION OF 4S-Van (4S-Van 구현을 위한 DGPS/INS 통합 알고리즘 설계)

  • 김성백;이승용;김민수;이종훈
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.351-366
    • /
    • 2002
  • In this study, we developed low cost INS and (D)GPS integration for continuous attitude and position and utilized it for the determination of exterior orientation parameters of image sensors which are equipped in 4S-Van. During initial alignment process, the heading information was extracted from twin GPS and fine alignment with Kalman filter was performed for the determination of roll and pitch. Simulation and van test were performed for the performance analysis. Based on simulation result, roll and pitch error is around 0.01-0.03 degrees and yaw error around 0.1 degrees. Based on van test, position error in linear road is around 10 cm and curve around 1 m. Using direct georeferencing method, the image sensor's orientation and position information can be acquired directly from (D)GPS/INS integration. 4S-Van achieved 3D spatial data using (D)GPS/INS and image data can be applied to the spatial data integration and application such as contemporary digital map update, road facility management and Video GIS DB.

Design of Environment Measurement System using the Wireless Devices (무선단말기를 이용한 환경 측정망 시스템 설계 및 구현)

  • Kim Seok-Hun;Kim Jung-Hwan;Song Jae-Sook;Song Jung-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.534-537
    • /
    • 2006
  • Currently, The fast development which radio communication technique is creating new services from the industry sector which is various from convenient characteristic and the ease characteristic side. Specially, rise and development of the radio communication technique which is various from environment monitor ring field makes to be improved about sharp curtailment of establishment and logistics relation expense, and collection period of the data which occurs real-time from site, reliability and delivery characteristic. But continuous application and the success about the environment monitor ring field of radio communication technique will be able to trust And It is important to provide time information which is appropriate real-time. So this paper plans the sensor network based on environment measurement watch which applies a radio communication technique.

  • PDF

Development of Three-Dimensional Gamma-ray Camera (방사선원 3차원 위치탐지를 위한 방사선 영상장치 개발)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Soon-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.486-492
    • /
    • 2015
  • Radiation source imaging system is essential for protecting of radiation leakage accidents and minimizing damages from the radioactive materials, and is expected to play an important role in the nuclear plant decommissioning area. In this study, the stereoscopic camera principle was applied to develop a new radiation imaging device technology that can extract the radiation three-dimensional position information. This radiation three-dimensional imaging device (K3-RIS) was designed as a compact structure consisting of a radiation sensor, a CCD camera, and a pan-tilt only. It features the acquisition of stereoscopic radiation images by position change control, high-resolution detection by continuous scan mode control, and stereoscopic image signal processing. The performance analysis test of K3-RIS was conducted for a gamma-ray source(Cs-137) in radiation calibration facility. The test result showed that a performance error with less than 3% regardless of distances of the objects.

A Query Preprocessing Tool for Performance Improvement in Complex Event Stream Query Processing (복합 이벤트 스트림 질의 처리 성능 개선을 위한 질의 전처리 도구)

  • Choi, Joong-Hyun;Cho, Eun-Sun;Lee, Kang-Woo
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.8
    • /
    • pp.513-523
    • /
    • 2015
  • A complex event processing system, becoming useful in real life domains, efficiently processes stream of continuous events like sensor data from IoT systems. However, those systems do not work well on some types of queries yet, so that programmers should be careful about that. For instance, they do not sufficiently provide detailed guide to choose efficient queries among the almost same meaning queries. In this paper, we propose an query preprocessing tool for event stream processing systems, which helps programmers by giving them the hints to improve performance whenever their queries fall in any possible bad formats in the performance sense. We expect that our proposed module would be a big help to increases productivity of writing programs where debugging, testing, and performance tuning are not straightforward.

Study on Development of Portable Incubator (휴대용 인큐베이터의 개발에 관한 연구)

  • Eizad, Amre;Zahra, Falak;Alam, Hamza;Tahir, Hassan;Bangash, Afrasiab Khan;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.9
    • /
    • pp.1-6
    • /
    • 2019
  • Preterm children require a controlled environment that is as close as possible to that inside the womb. Incubators are well equipped to fulfill this requirement; however, they are cumbersome and expensive, thereby restricting their portability and availability in less developed and rural areas. This research comprises the development and system validation of a portable incubator. The system consists of a collapsible baby enclosure that can be stowed inside the system base when not in use. The enclosure is made from acrylic such that it is easy to clean and allows unhindered visual observation of the occupant while being robust enough to withstand transit conditions. The system can be powered either by a mains supply or a 12-VDC automobile power supply. Additionally, it has an onboard battery to ensure a continuous supply during transit. A Peltier plate controlled using a microcontroller ensures the desired enclosure temperature irrespective of the ambient temperature. Built-in sensor probes can measure the skin temperature, pulse rate, blood oxygenation level, and ECG of the infant and display them on the system screen. The system function is validated by testing its peak power consumption and the heating and cooling performances of the environment control system.