• 제목/요약/키워드: Continuous Rotary

검색결과 59건 처리시간 0.03초

연속 회전 등통로각압축 공정의 유한요소해석 (Finite Element Analysis of Continuous Rotary-Die Equal Channel Angular Pressing)

  • 윤승채;서민홍;김형섭
    • 소성∙가공
    • /
    • 제15권7호
    • /
    • pp.524-528
    • /
    • 2006
  • Although equal channel angular pressing (ECAP), imposing large plastic shear strain deformation by moving a workpiece through two intersecting channels, is a promising severe plastic deformation method for grain refinement of metallic materials, its batch type characteristic makes ECAP inefficient for multiple-passing. Rotary-die ECAP (RDECAP) proposed by Nishida et al. can achieve high productivity by using continuous processing without taking out the samples from the channel. However, plastic deformation behavior during RD-ECAP has not been investigated. In this study, material plastic flow and strain hardening behavior of the workpiece during RD-ECAP was investigated using the finite element method. It was found that plastic deformation becomes inhomogeneous with the number of passes due to an end effect, which was not found seriously in ECAP. Especially, decreasing corner gap with increasing the number of passes was observed and explained by the strain hardening effect.

GT rotary file을 이용한 근관성형법과 충전방법의 비교 (COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS)

  • 강유미;진정희;유미경;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권5호
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).

Continuous rotary system과 single file system의 만곡 근관 형태 유지능에 대한 비교 연구 (Comparative Study on the Ability of Instruments to Maintain Original Canal Curvature of Continuous rotary System and Single File System)

  • 박상희;김덕중;송용범;이혜윤;김형선;이광원;유미경
    • 구강회복응용과학지
    • /
    • 제28권4호
    • /
    • pp.371-383
    • /
    • 2012
  • 성공적인 근관치료를 위하여 원래 근관 형태를 따르는 근관 성형 과정이 중요하다. 그러나 대부분의 근관은 만곡되어 있고, 근관 성형 기구는 직선의 금속을 기본으로 만들어지기 때문에 근관 성형 후 만곡 근관이 원래 근관 형태를 벗어나는 오류가 나타날 수 있다. 이런 오류들로 인하여 근관 치료가 실패할 수 있으므로 근관 성형시 원래 만곡형태를 유지할 수 있는 다양한 기술과 방법들이 소개되고 있다. 본 연구의 목적은 만곡 근관 형태의 레진 모형을 이용하여 기구의 형태와 사용방법이 다른 세 가지 Ni-Ti 파일을 사용하여 Ni-Ti 파일 종류에 따른 만곡 근관에 대한 성형 후 형태 유지능을 비교하는 것이다. 직경과 경사도가 ISO 15, 0.02인 30개의 레진모형을 사용하였다. 그룹 1은 Profile을 이용하여 #20/.06까지 근관 성형하였고, 그룹 2는 Mtwo를 이용하여 #35/.04까지 근관 성형하였으며, 그룹 3은 PathFile을 이용하여 glide path를 만들어준 다음 WaveOne 파일 중 Primary을 사용하여 근관 성형하였다. 기구 사용 전과 후의 레진모형을 스캔하여 디지털 이미지로 만들었다. 각 이미지를 중첩시킨 다음 Matlab r2010b 소프트웨어를 이용하여 곡률반경의 비(CRr)를 계산하였다. 이를 바탕으로 Ni-Ti file 간 성형 후 형태 유지능을 비교하기 위하여 1-way ANOVA를 이용하여 세 그룹의 CRr의 차이에 대한 유의성 검정을 시행하였다.(P<.05) 또한 continuous rotary system과 single file system간의 형태 유지능을 비교하기 위하여 independent t-test를 이용하였다.(P<.05) 곡률반경의 비(CRr)를 이용하여 Ni-Ti 파일 종류에 따른 만곡 근관의 형태 유지능을 비교한 결과 Ni-Ti file 간에는 통계적으로 유의한 차이가 있었다.(P<0.05) ProFile과 WaveOne은 Mtwo에 비해서 만곡 근관에서의 형태 유지능이 우수하게 나타났다.Ni-Ti 기구 사용 방법에 따른 만곡 근관 형태 유지능을 비교한 결과 continuous rotary system과 single file system 간에는 통계적으로 유의한 차이를 보이지 않았다.(P>0.05) 본 연구결과에 따르면, ProFile과 WaveOne은 Mtwo에 비하여 만곡 근관에서의 형태 유지능이 통계적으로 유의하게 높게 나타났으므로, ProFile과 WaveOne이 만곡근관에 대한 형태 유지능이 우수하다고 할 수 있다. 만곡근관에서의 형태 유지능에 있어서 continuous rotary system과 single file system은 만곡근관에서의 형태 유지능에 차이가 없다.

Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems

  • Ramyadharshini, Tamilkumaran;Sherwood, Inbaraj Anand;Vigneshwar, V Shanmugham;Prince, Prakasam Ernest;Vaanjay, Murugadoss
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.22.1-22.10
    • /
    • 2020
  • Objectives: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. Materials and Methods: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. Results: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. Conclusions: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15.

Exact and approximate solutions for free vibrations of continuous partial-interaction composite beams

  • Sun, Kai Q.;Zhang, Nan;Zhu, Qun X.;Liu, Xiao
    • Steel and Composite Structures
    • /
    • 제44권4호
    • /
    • pp.531-543
    • /
    • 2022
  • An exact dynamic analytical method for free vibrations of continuous partial-interaction composite beams is proposed based on the Timoshenko beam theory. The main advantage of this method is that the independent shear deformations and rotary inertia of sub-beams are considered, which is more in line with the reality. Therefore, the accuracy of eigenfrequencies obtained by this method is significantly improved, especially for higher order modes, compared to the existing methods where the rotary angles of both sub-beams are assumed to be equal irrespective of the differences in the shear stiffness of each sub-beam. Furthermore, the solutions obtained by the proposed method are exact owing to no introduction of approximated displacement and force fields in the derivation. In addition, an exact analytical solution for the case of simply supported is obtained. Based on this, an approximate expression for the fundamental frequency of continuous partial-interaction composite beams is also proposed, which is useful for practical engineering applications. Finally, the practicability and effectiveness of the proposed method and the approximate expression are explored using numerical and experimental examples; The influence factors including the interfacial interaction, shear modulus ratio, span-to-depth ratio, and side-to-main span length ratio on the eigenfrequencies are presented and discussed in detail.

Incidence of postoperative pain after using single continuous, single reciprocating, and full sequence continuous rotary file system: a prospective randomized clinical trial

  • Umesh Kumar;Pragnesh Parmar;Ruchi Vashisht;Namita Tandon;Charan Kamal Kaur
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권2호
    • /
    • pp.91-99
    • /
    • 2023
  • Background: Extrusion of debris is a major factor that results in postoperative pain during root canal treatment with various instruments and instrumentation techniques. Therefore, instrumentation techniques that extrude minimal debris into the periapical area while reducing pain are desirable. This study aimed to compare the incidence of postoperative pain and intake of analgesic medication (frequency and quantity) after endodontic treatment of mandibular posterior teeth using two single files and full-sequence continuous rotary systems with different kinematic motions. Methods: Thirty-five of 105 patients were assigned equally to three groups according to the instrumentation system used: ProTaper Next (PN) X2, 25/06 (Dentsply, Maillefer, Ballaigues, Switzerland), One Shape (OS), #0.25/06 (Micro Mega, Besancon, France), and Wave One Gold (WG), Red - #0.25, 0.07 (Dentsply, Maillefer, Ballaigues, Switzerland). Five specialists were included in this study design; each professional prepared 21 teeth, and randomly selected 7 per instrument system. The VAS sheet ranging from 0 to 10 was used to record the initial and postoperative pains at 24, 48, and 72 h, and 7th day after single visit endodontic treatment in mandibular premolars and molars with a diagnosis of asymptomatic irreversible pulpitis with or without apical periodontitis. Postoperatively, an analgesic, ibuprofen 400 mg was administered for intolerable pain at a dose of 1 tablet for 6 h. The patients were asked over the telephone regarding postoperative pain at intervals of 24, 48, and 72 h, and 7th day using a visual analogue scale. Result: There were no statistically significant differences among the PN, OS, and WG systems (P > 0.05) with regard to the incidence of postoperative pain at any of the four time points assessed. Conclusion: The intensity of postoperative pain, frequency, and analgesic intake were similar across all three types of instrument systems; however, the reciprocating single file (WG) was associated with less postoperative pain than the full sequence continuous rotary file.

로터리 압축기용 Short-Cycle 신뢰성 시험장치 제안 (Suggestion of Test Apparatus for Reliability Evaluation of a Rotary Compressor with a Short-Cycle)

  • 이태구;이상재;김현우;김상현;이재헌;유호선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.584-589
    • /
    • 2006
  • In this paper, a test apparatus for reliability evaluation of a rotary compressor has been suggested with a short-cycle concept. $CO_2$ refrigerant is adopted for this cycle to avoid phase change during cycle operation. Evaporator is not necessary in short-cycle. Utilizing a short-cycle, the test apparatus was built on the purpose of evaluating the reliability of each rotary compressor on the conveyer belt of the factory. The primary validation of the test apparatus is discussed by analyzing the experimental heat balance data. Additional validation was performed through the overload continuous operation test where the wear rate of the $CO_2$ short-cycle was found to similar to that of the R22 normal-cycle. The reliability evaluation test apparatus with a short-cycle in present investigation was found simple and efficient in the view of reducing sample numbers, costs, and test time in analyzing the reliability of rotary compressors.

  • PDF

돈분뇨 슬러리 퇴비화시 부재료 절감형 시설 연구 (Studies on Swine Slurry Composting Facilities with Curtailment of Bulking Agents)

  • 김태일;한정대;정광화;박치호;권두중;남은숙;김형호;이덕수
    • 한국축산시설환경학회지
    • /
    • 제4권1호
    • /
    • pp.21-28
    • /
    • 1998
  • This study was carried out to estimate the economic impacts on operation cost and curtail the bulking agent between two kinds of plants in swine farms. Bulking agents and Plants have a variety of roles in the fields of the composting for livestock manure and also represent an economic problem in terms of plant operation costs and compost production. Two farms which have rotary(size of reactor : 10${\times}$35${\times}$1.5m) or bucket(size of reactor : 10${\times}$68${\times}$2m) plants were used for 24 weeks for bucket conveyor system, which are composed of refilling rice hull as a bulking agent every 3 weeks till decreasing volume, for 4 weeks for rotary conveyor system, which has continuous compost production system without refilling rice hull, respectively. Composts was produced in 24 weeks in the bucket conveyor system, in 4 weeks in the rotary conveyor system, respectively. The results are as follows : 1. The tissue change of Rice hull at the composts of 45 days pursuant to composting steps was more crumbling in bucket conveyor system than in rotary conveyor system. 2. Microbial counts of the final composts for safety and quality showed that total bacteria counts was 1.01${\times}$108 cfu/g in bucket conveyor system, 2.82${\times}$108 cfu/g in rotary conveyor system, Salmonella was 0.3${\times}$102 cfu/g in bucket conveyor system, 7.6${\times}$102 cfu/g in rotary conveyor system, colifom bacteria was 0.5${\times}$106 cfu/g in bucket conveyor system, 1.5${\times}$106cfu/g in rotary conveyor system, fungi 1.24${\times}$106 cfu/g in bucket conveyor system, 0.01${\times}$106 cfu/g in rotary conveyor system, respectively. However, Any system used in this trial could not be met the regulation of A grade compost of EPA and USA. 3. C:N ratio according to the composting was more rapidly changed in bucket conveyor system with 64.5 of 5 days compost to 25.4 of final products than in rotary conveyor system with 26.7 of 5 days compost to 25.9 of final products. 4. Based on the mechanical characteristics of plants used in trial and compared with Rotary conveyor system, the Bucket conveyor system in which has 0.72 ㎥/㎥ of bulking agent capacity per slurry could be curtailed 1.78 ㎥of rice hull for disposal of waste, 1㎥. It was proper facilities to produce composts quantitative in Rotary conveyor system, and to treat waste quantitative and obtain good results in compost quality in Bucket conveyor system.

5축가공을 위한 공구경로 및 자세 제어 기술 (The Control Technology of Cutter Path and Cutter Posture for 5-axis Control Machining)

  • 황종대;임은성;정윤교
    • 한국기계가공학회지
    • /
    • 제10권2호
    • /
    • pp.1-8
    • /
    • 2011
  • 5-axis NC machining has a good advantage of the accessibility of tool motion by adding two rotary axes. It offers numerous advantages such as expanding machining fields in parts of turbo machineries like impeller, propeller, turbine blade and rotor, reasonable tool employment and great reduction of the set-up process. However, as adding two rotary axes, it is difficult to choose suitable machining conditions in terms of cutter path and cutter posture at a cutter contact point. Therefore in this paper, it is proposed to decide suitable machining condition through an experimental method such as adopting various cutter paths, cutter postures types. Also, in order to increase the efficiency of 5-axis machining, it is necessary to minimize the cutter posture changes and create a continuous cutter path while avoiding interference. This study, by using an MC-space algorithm for interference avoidance and an MB-spline algorithm for continuous control, is intended to create a 5-axis machining cutter path with excellent surface quality and economic feasibility. finally, this study will verify the effectiveness of the suggested method through verification processing.

Simulated resin root canal에서 엔진 구동형 Ni-Ti 파일로 근관성형 후 Buchanan plugger의 근관 내 삽입깊이에 대한 비교 연구 (A STUDY OF INSERTION DEPTH OF BUCHANAN PLUGGER AFTER SHAPING USING NI-TI ROTARY FILES IN SIMULATED RESIN ROOT CANALS)

  • 박연식;김동준;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제31권2호
    • /
    • pp.125-132
    • /
    • 2006
  • 본 연구는 레진 블록에서 엔진구동형 Ni-Ti기구를 이용하여 근관성형 후 Buchanan plugger의 삽입 깊이에 대한 비교를 통해 임상적 상황에서 Ni-Ti 파일로 근관 성형 후 Continuous wave of condensation technique을 이용한 근관 충전시 적절한 크기의 Buchanan plugger 선택에 지침을 제공하기 위해 시행되었다. 만곡근관과 직선근관을 가진 레진 블록에서 ProTaper와 ProFile을 이용하여 근관 성형을 하였다. 성형 후 근관에 Buchanan plugger가 근관벽과 처음으로 접촉하는 부위까지 삽입한 후 그 상태에서 스캐너를 이용하여 이미지를 얻었다. 이미지 분석 프로그램을 이용해 근첨에서 plugger 첨부까지의 거리를 얻었다. 각 기구에 대한 plugger 삽입깊이에 대한 유의성을 검정하기 위해 one-way ANOVA를 시행하였고, 사후검정을 위해 Scheffe's test를 시행하였다. 본 연구의 결과 만곡되고 좁은 근관에서, ProTaper F2와 F3로 마무리 성형한 근관에서 F, FM크기의 plugger를 사용할 경우 Continuous wane of condensation technique으로 적절한 근관충전이 가능함을 시사하였다.