• Title/Summary/Keyword: Continuous Heating System

Search Result 85, Processing Time 0.024 seconds

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Steam Gasification Characteristics of Oil Sand Coke in a Lab-Scale Fixed Bed Gasifier (실험실 규모의 고정층 가스화기에서 오일샌드 코크스의 수증기 가스화 특성)

  • Yoon, Sang Jun;Choi, Young-Chan;Lee, See-Hoon;Lee, Jae Goo
    • Applied Chemistry for Engineering
    • /
    • v.20 no.1
    • /
    • pp.62-66
    • /
    • 2009
  • Utilization and interest of unconventional fuel and process residue such as oil sand and its residue, oil sand coke, have been increased because of the continuous rise of fuel price and conventional fuel availability. In this study, the gasification of oil sand coke produced from coking process of oil sand was performed to utilize as an energy resource using lab-scale fixed bed gasification system. The combustion characteristics of oil sand bitumen and oil sand coke were investigated by using TGA and lab-scale gasification system was applied to reveal the characteristics of produced syngas composition with oxygen/fuel ratio, temperature and steam injection rate. Oil sand coke shows a high carbon content, heating value and sulfur content and low ash content and reactivity. In case of oil sand coke gasification, generally with increasing temperature, the amount of steam introduced and decreasing oxygen injection rate, $H_2$ content in product gas increased while the $CO_2$ content decreased. The calorific value of syngas shows about $2100kcal/Nm^3$ and this result indicates that the oil sand coke can be used as a resource of hydrogen and fuel.

Three-dimensional Numerical Prediction on the Evolution of Nocturnal Thermal High (Tropical Night) in a Basin

  • Choi, Hyo;Kim, Jeong-Woo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.25 no.1
    • /
    • pp.57-81
    • /
    • 1997
  • Numerical prediction of nocturnal thermal high in summer of the 1995 near Taegu city located in a basin has been carried out by a non-hydrostatic numerical model over complex terrain through one-way double nesting technique in the Z following coordinate system. Under the prevailing westerly winds, vertical turbulent fluxes of momentum and heat over mountains for daytime hours are quite strong with a large magnitude of more than $120W/\textrm{m}^2$, but a small one of $5W/\textrm{m}^2$ at the surface of the basin. Convective boundary layer (CBL) is developed with a thickness of about 600m over the ground in the lee side of Mt. Hyungje, and extends to the edge of inland at the interface of land sea in the east. Sensible heat flux near the surface of the top of the mountain is $50W/\textrm{m}^2$, but its flux in the basin is almost zero. Convergence of sensible heat flux occurs from the ground surface toward the atmosphere in the lower layer, causing the layer over the mountain to be warmed up, but no convergance of the flux over the basin results from the significant mixing of air within the CBL. As horizontal transport of sensible heat flux from the top of the mountain toward over the basin results in the continuous accumulation of heat with time, enhancing air temperature at the surface of the basin, especially Taegu city to be higher than $39.3^{\circ}C$. Since latent heat fluxes are $270W/\textrm{m}^2$ near the top of the mountain and $300W/\textrm{m}^2$ along the slope of the mountain and the basin, evaporation of water vapor from the surface of the basin is much higher than one from the mountain and then, horizontal transport of latent heat flux is from the basin toward the mountain, showing relative humidity of 65 to 75% over the mountain to be much greater than 50% to 55% in the basin. At night, sensible heat fluxes have negative values of $-120W/\textrm{m}^2$ along the slope near the top of the mountain and $-50W/\textrm{m}^2$ at the surface of the basin, which indicate gain of heat from the lower atmosphere. Nighttime radiative cooling produces a shallow nocturnal surface inversion layer with a thickness of about 100m, which is much lower than common surface inversion layer, and lifts extremely heated air masses for daytime hours, namely, a warm pool of $34^{\circ}C$ to be isolated over the ground surface in the basin. As heat transfer from the warm pool in the lower atmosphere toward the ground of the basin occurs, the air near the surface of the basin does not much cool down, resulting in the persistence of high temperature at night, called nocturnal thermal high or tropical night. High relative humidity of 75% is found at the surface of the basin under the moderate wind, while slightly low relative humidity of 60% is along the eastern slope of the high mountain, due to adiabatic heating by the srong downslope wind. Air temperature near the surface of the basin with high moisture in the evening does not get lower than that during the day and the high temperature produces nocturnal warming situation.

  • PDF

Implementation of the Urban Development Projects in Ulaanbaatar (도시개발 여건을 고려한 울란바타르 건설사업 참여방안)

  • Jeong, Yeun-Woo;Seong, Jang-Hwan
    • Land and Housing Review
    • /
    • v.3 no.4
    • /
    • pp.357-367
    • /
    • 2012
  • The efficient business scheme were suggested with the consideration of the local development condition at Ulaanbaatar. Major findings of the study were presented as follows. First, high level of education and the underground resources are presented as the merits of Mongolia. On the other side, the defects are limited domestic demands of 2.6 millions of population and the insufficiency of the infrastructure. The improvement of the infrastructures like roads, water & sewage, electric power, and heating is urgent while the development pressure of Ulaanbaatar is expected to be high due to the continuous inflow of population. Secondly, the Mongolian land system consists of the right of ownership, lease and use, therefore there are some differences among the right of land. Thirdly, definite business scheme to sell land in lots and to sell buildings in lots are suggested which are actual methods to participate in the development project in Ulaanbaatar. Moreover, enhancing the possibility to sell the lands, fixing the proper sale price to secure the profit, finding the proper buyer for the profitable lands, investing of quota and guaranteeing of granting the principal and interest by the Mongolian government, etc. are presented as consideration when participate in projects.

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF