• Title/Summary/Keyword: Continuous Heating Control

Search Result 59, Processing Time 0.035 seconds

Power Control of Induction Heating Process for TR forging (TR 단조를 위한 유도 가열 공정의 전력제어)

  • Song M. C.;Ju S. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.230-233
    • /
    • 2004
  • The purpose of this study is to establish the optimal induction heating conditions of various preform types used for TR forging. The finite element model coupled electro-magnetic and transient heat transfer was employed to evaluate the distribution of temperature at the billet. Power control method was applied to control temperature of preform in induction heating because TR forging is not a continuous process. Power schedule that consists of heating and holding stage was suggested. In heating stage, power is inversely proportional to diameter of preform but the time of heating stage is directly proportional to the diameter of preform. But, in holding stage, the required power for thermal equilibrium per unit volume of the billet decreases with an increase in a diameter of billet due to the increase of efficiency.

  • PDF

An experimental study on the multiple parameter switching control for floor heating system (바닥 난방공간의 다인자 제어에 관한 실험적 연구)

  • Cho, S.H.;Tae, C.S.;Jang, C.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

Induction Heating PWM High Frequency Inverter using New Active Auxiliary Resonant Snubber

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Kim, Hong-Sin;Jung, Sang-Hwa;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.40-51
    • /
    • 2008
  • This research presents a new active auxiliary resonant snubber with for induction heating PWM high frequency inverter solving the problem of induction heating PWM high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the active auxiliary resonant snubber with for induction heating PWM high frequency inverter. The inverter circuit which is attempted by the on-off operation of a switch has the effect of reducing the power loss due to soft switching and high frequency switching. This confirms that power regulation is possible on a continuous basis from 0.25[kW] to 2.84[kW] where the duty factor(D) changes from 0.08 to 0.3 under zero current switching which operates by an asymmetrical pulse width modulating control. The power conversion efficiency is 95[%]. Due to these results, the active auxiliary resonant snubber for an induction heating PWM high frequency inverter is considered effective as a source of induction heating.

Regularity and coupling correlation between acoustic emission and electromagnetic radiation during rock heating process

  • Kong, Biao;Wang, Enyuan;Li, Zenghua
    • Geomechanics and Engineering
    • /
    • v.15 no.5
    • /
    • pp.1125-1133
    • /
    • 2018
  • Real-time characterization of the rock thermal deformation and fracture process provides guidance for detecting and evaluating thermal stability of rocks. In this paper, time -frequency characteristics of acoustic emission (AE) and electromagnetic radiation (EMR) signals were studied by conducting experiments during rock continuous heating. The coupling correlation between AE and EMR during rock thermal deformation and failure was analyzed, and the microcosmic mechanism of AE and EMR was theoretically analyzed. During rock continuous heating process, rocks simultaneously produce significant AE and EMR signals. These AE and EMR signals are, however, not completely synchronized, with the AE signals showing obvious fluctuation and the EMR signals increasing gradually. The sliding friction between the cracks is the main mechanism of EMR during the rock thermal deformation and fracture, and the AE is produced while the thermal cracks expanding. Both the EMR and AE monitoring methods can be applied to evaluate the thermal stability of rock in underground mines, although the mechanisms by which these signals generated are different.

Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

LCD with Tunable Viewing Angle by Thermal Modulation of Optical Layer

  • Gwag, Jin-Seog;Lee, You-Jin;Han, In-Young;Yu, Chang-Jae;Kim, Jae-Hoon
    • Journal of Information Display
    • /
    • v.10 no.1
    • /
    • pp.19-23
    • /
    • 2009
  • In this paper, we review the proposed liquid crystal display (LCD) with a tunable viewing angle consisting of a conventional liquid crystal display (LCD) panel and a thermally variable retardation layer (TVRL) characterized by uniformly aligned LC film with transparent indium-tin-oxide electrodes for Joule heating. In the TVRL, nematic phase is transitioned into isotropic by Joule heating. The numerical calculation showed that the intrinsic wide viewing angle was achieved at the isotropic phase of the TVRL by Joule heating, whereas the narrow viewing angle was obtained at the nematic phase of the TVRL. The simulated and experimental results of the proposed LCD show continuous and symmetrical viewing angle characteristics by tuning the retardation of TVRL using Joule heating. The structure of the viewing angle control proposed here is adoptable to all LCD modes with wide viewing angle characteristics.

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Design of New Current Full-Bridge Resonant Inverter for Induction Heating System (유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계)

  • Lee, Sang-Hun;Lim, Sang-Kil;Song, Seung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Design of Adaptive Inverse Control for Center Position Control of Steel-Strip in Continuous Annealing Line (연속소둔로에서 판중심 위치 제어를 위한 적응 역비례 제어기의 설계)

  • Kim, Young-Su;Jo, Sung-Eun;Lee, Young-Kow;Kim, Sang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.608-610
    • /
    • 2004
  • In continuous annealing line (CAL), POSCO, the center position control (CPC) is an essential technique that renders the steel-strip to pass at the center of a roll in order to prevent the strip from skewing or breaking. The CPC algorithm currently installed on the steering roll in the heating section of CAL is to control the strip position by using the reverse phase of error from the center position, without considering the dynamics of strip horizontal movement. Such algorithm may, unfortunately, require a manual operation occasionally when the range of strip input becomes wide, causing the dynamics 0 be dominant. Other PID-type control is rarely used in automatic operation because the excess of response may occur when the discontinuous points such as welding joints pass through rolls. In this paper, we identify the CPC system by using off-line data and design a compensator for the excessive dynamics by using the adaptive inverse control. Simulation result depicts the improved reliability of the proposed CPC system.

  • PDF