• 제목/요약/키워드: Continuous Cardiac Output

검색결과 28건 처리시간 0.02초

적출심장의 장시간 [24시간] 보존에 관한 실험적 연구 -4$^{\circ}C$ 관류 보존법- (Experimental Study of Isolated Canine Heart Preservation for 24 Hours at 4$^{\circ}C$ - A Portable Continuous Hypothermic Perfusion System -)

  • 이종국
    • Journal of Chest Surgery
    • /
    • 제21권3호
    • /
    • pp.425-446
    • /
    • 1988
  • After 24 hours of preservation under 15 mmHg perfusion pressure the recovery rates of isolated canine hearts were determined. Preservation was performed in a cold room maintained at 4*C with 4 different types of perfusates bubbled with a mixture of 95% 0y and 5% CO~ using a modified perfusion unit designed in our institute. The perfusates used were as follows; Group 1: Krebs-Henseleit solution, Group 2: Krebs solution added by albumin and PGE1. Group 3: Modified Wicomb*s solution, Group 4: Modified Collin*s solution. The extent of myocardial recovery was evaluated using a modified isolated carmine perfusion model by measuring heart rate, systolic arterial pressure, left atrial pressure[LAP] and cardiac output. In addition to the above hemodynamic parameters, biochemical and enzymatic assays from perfusates and electron microscopic changes of the myocardium were also studied. The results were as follows; 1] The heart recovery rates were 41.6%, 53.4% and 108.9% in groups 1, 2 and 3, respectively, and group 3 elicited the best result[p< 0.001]. The heart beat was never recovered in group 4. 2] Recovered systolic arterial pressures[mmHg] were 63.3% in group 1, 94.9% in group 2 and 94.3% in group 3. 3] LAPs[mmHg] were 20 in group 1, 13.5 in group 2 and 11.2 in group 3, which suggested that the best myocardial preservation was elicited in group 3[p< 0.05]. 4] Cardiac output, the sum of aortic stroke volume and coronary leakage, were 69.1% in group 2, and 90.7% in group 3, but these were not statistically significant[p=0.24]. No aortic stroke output was measured in group 1 and 4. 5] The degree of myocardial edema increase was 17.5` in group 1, 24.6% in group 2, 20.9% in group 3 and 55.3% in group 4. But there were no statistical differences in each group[p= 0.08]. 6] CPK-MB[U/L] levels were increased 750% and 332%[p< 0.05], glucose levels[mg/dl] 60.5% and 78.2% and SGOT[U/L] levels 523% and 333%, in groups 2 and 3, respectively. Biochemical and enzymatic assays could not be performed in group 1 and group 4, because of poor recovery of heart beat. 7] Electron microscopic findings in the myocardium of most groups revealed slight to moderate muscle cell and mitochondrial edema. But all these findings were within the limits of reversible change. From these above results, it is suggested that modified Wicomb*s solution seems to be the most useful physiologic salt solution for preservation of the heart. We propose that after further study and improvement, our portable continuous hypothermic perfusion system will contribute to the development of a better preservation method for donor hearts for human heart transplantation.

  • PDF

나노웹 섬유형 전극 인터페이스와 KHU Mark2 EIT 시스템을 이용한 생체신호 동기 도전율 영상법 (Gated Conductivity Imaging using KHU Mark2 EIT System with Nano-web Fabric Electrode Interface)

  • 김태의;김현지;위헌;오동인;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권1호
    • /
    • pp.39-46
    • /
    • 2012
  • Electrical impedance tomography(EIT) can produce functional images with conductivity distributions associated with physiological events such as cardiac and respiratory cycles. EIT has been proposed as a clinical imaging tool for the detection of stroke and breast cancer, pulmonary function monitoring, cardiac imaging and other clinical applications. However EIT still suffers from technical challenges such as the electrode interface, hardware limitations, lack of animal or human trials, and interpretation of conductivity variations in reconstructed images. We improved the KHU Mark2 EIT system by introducing an EIT electrode interface consisting of nano-web fabric electrodes and by adding a synchronized biosignal measurement system for gated conductivity imaging. ECG and respiration signals are collected to analyze the relationship between the changes in conductivity images and cardiac activity or respiration. The biosignal measurement system provides a trigger to the EIT system to commence imaging and the EIT system produces an output trigger. This EIT acquisition time trigger signal will also allow us to operate the EIT system synchronously with other clinical devices. This type of biosignal gated conductivity imaging enables capture of fast cardiac events and may also improve images and the signal-to-noise ratio (SNR) by using signal averaging methods at the same point in cardiac or respiration cycles. As an example we monitored the beat by beat cardiac-related change of conductivity in the EIT images obtained at a common state over multiple respiration cycles. We showed that the gated conductivity imaging method reveals cardiac perfusion changes in the heart region of the EIT images on a canine animal model. These changes appear to have the expected timing relationship to the ECG and ventilator settings that were used to control respiration. As EIT is radiation free and displays high timing resolution its ability to reveal perfusion changes may be of use in intensive care units for continuous monitoring of cardiopulmonary function.

심부전 정도에 따른 좌심실보조장치의 박동효율예측을 위한 심장의 전기역학적 유한요소 모델의 응용 (Application of Cardiac Electromechanical FE Model for Predicting Pumping Efficacy of LVAD According to Heart Failure Severity)

  • 정대현;임기무
    • 대한기계학회논문집B
    • /
    • 제38권8호
    • /
    • pp.715-720
    • /
    • 2014
  • 좌심실보조장치(LVAD)가 심실부하감소에 미치는 영향을 극대화 하기 위해, 심실보조장치 치료를 위한 최적의 심부전 심각도 단계를 찾는 것은 중요하다. 우리는 심부전 정도에 따른 LVAD 의 박동효율을 이론적으로 예측하였다. 우리는 혈관시스템의 6 컴파트먼트의 Wind-kessel 모델과 연동된 심실의 삼차원 유한요소모델을 사용하였다. 이 모델을 이용하여, LVAD 치료 하에서 심부전의 정도에 따라 심실의 수축성 ATP 소모율, 좌심실압력, 심박출량, 심박출 분획, 1 회심박출량 등과 같은 심장응답을 예측하였다. LVAD 치료 중에 에너지학적 부하조건을 암시하는 수축성 ATP 소모율은 5 단계 심부전 조건에서 가장 크게 감소하였다. 따라서, 우리는 LVAD 를 회복으로의 가교로서 고려하고 있을 때, 심부전 5 단계에서 LVAD 치료를 시작하는 것이 가장 적절하다는 결론을 내린다.

안지오텐신 ll 수용체 길항약 CJ-10513이 고민도 심실 pacing 천에서의 혈행동태에 미치는 영향 (Acute Hemodynamic Effects of CJ-10513, an Angiotensin IIReceptor Antahonest, in Dog Treated with High Friquency Ventricular Pacing)

  • 김영훈;정성목;신재규;최재묵;정성학;배훈;이건호;김제학;안양수
    • Biomolecules & Therapeutics
    • /
    • 제6권2호
    • /
    • pp.199-203
    • /
    • 1998
  • Acute hemodynamic effects of CJ-18513, a non-peptide angiotensin IIreceptor antagonist, were examined in mongrel dogs treated with high frequency ventricular pacing for one week. Rapid ventricular pacing reduced mean blood pressure (mBP), Lvdp/dt and cardiac output (CO), and increased the left ventricular end-diastolic pressure (LVEDP) and pulmonary capillary wedge pressure (PCWP). Continuous infusion of CJ-10513 at doses of 10 and 20$\mu$g/kg/min, respectively, for 30 minutes reduced mBP, LVEDP and myocardial oxygen consumption rate (MVO,) and shifted the cardiac function curve (CO-LVEDP ourve) to the left in this dog model. In conclusion, CJ-10513 decreased the preload and afterload and increased the cardiac function in dogs with pacing-induced heart failure.

  • PDF

연속 온혈 심정지액의 임상경험 - 심장 판막 수술 환자 대상 - (Clinical Experiences of Continuous Warm Blood Cardioplegia ; Valvular Heart Surgery)

  • 이종국;박승일;조재민;원준호
    • Journal of Chest Surgery
    • /
    • 제31권4호
    • /
    • pp.353-361
    • /
    • 1998
  • 저온 요법은 심장수술중 심근 보호에 있어서 기본적인 요소로 널리 인식되어 왔다. 비록 저온 요법이 산소 요구량을 감소시켜 허혈성 심정지의 기간을 연장시키지만 저온 요법은 효소 기능과 에너지 생성, 세포 보존에 해를 끼치는 등의 단점을 나타낸다. 심장의 이상적인 보호 상태는 전기 기계적으로 정지하는 상태이며 혈액에 의해서 관류되는 상태 즉 호기의 심정지라고 생각된다. 전기 기계적 정지, 연속적인 온혈 심정지액의 관류에 의한 정온 호기 상태의 심정지에 기초를 둔 새로운 방법의 심근 보호법이 개발되었다. 1994년 1월부터 1996년 6월까지 간헐적 냉각 심정지액으로 심근 보호를 시행한 31명의 판막 수술을 받은 환자와 연속 온혈 심정지액을 사용하여 심근 보호를 실시한 30명의 판막 수술을 받은 환자를 임상적으로 비교 분석 하였다. 저자들의 결과는 연속 온혈 심정지액을 사용한 판막 수술을 받은 환자는 적어도 냉각 심정지액을 사용한 환자보다 대동맥 차단 해제후 자연 심박 재개율이 높으며, 술후 심부종이 발생하지 않아 심막 절개 부위의 봉합율이 높고 술후 12시간 동안의 배설되는 소변량이 증가된다는 점 및 좌측 횡격막 상승 소견이 없었으며 술후 1시간 및 12시간의 심근 효소 검사상 연속 온혈 심정지액을 사용한 군에서 그 수치가 낮은점 등으로 안전하고 효과적인 심근 보호가 이루어졌으며, 개념적으로 이것은 심장수술중에 우수한 심근 보호를 유지하는 새로운 방법임을 알 수 있었다.

  • PDF

관상동맥 풍선확장술 후의 개심술 (Aortocoronary bypass after PTCA)

  • 송명근
    • Journal of Chest Surgery
    • /
    • 제26권1호
    • /
    • pp.32-35
    • /
    • 1993
  • During the period from September 1989 through December 1992, 118 cases of coronary arterial bypass graft were performed at Department of Cardiothoracic Surgery, Asan Medical Center. Twenty-one of these had history of recent or remote percutaneous transluminal coronary angioplasty. They consisted of 13 males[age,58.7 + 5.4 years] and 8 females[age, 63.6 + 2.8years] with the mean age of 60.6. History of old myocardial infarction was noted in 24%[5/21] of the patients and congestive heart failure in 2 cases. The angina by type of presentation is unstable in all of the patients. The patterns of involvement of coronary arterial disease were left main disease[1], single vessel disease[5], double vessel involvement[10], and triple vessel involvement[5]. We performed 4 cases of single bypasses, 7 cases of double, 8 cases of triple, and 2 cases of quadruple bypasses. Total of 51 grafts[LIMA:12, RSVG:39] were inserted in 21 cases with average of 2.4 grafts per patient. The methods of myocardial protection were cold blood cardioplegia[8 cases], intermittent aortic occlusion[11], and continuous coronary perfusion with local coronary sharing[2]. There were no operative or late death. The only cardiac complication was 1 case of low cardiac output required IABP. The other complications were 1 case of sternal wound infection and 1 case of postoperative bleeding required reoperation. And there was no case of perioperative myocardial infarction. Postoperatively, 3 cases of recurrent angina were detected at 5, 7, and 18months after surgery. One of them was managed successfully with repeat PTCA[who was recurred 18 months postoperatively], and the other two with medication. I conclude that we can approach the patients more aggressively with PTCA, because of our acceptable operative risks.

  • PDF

Valsalva Maneuver에 따른 정상 성인의 지속적 혈류역동 변화 (Continuous Hemodynamic Profiles of Healthy Adults during Valsalva Maneuver)

  • 곽혜원;김나현
    • Journal of Korean Biological Nursing Science
    • /
    • 제11권1호
    • /
    • pp.68-76
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the hemodynamic changes in degree and duration that occur during Valsalva maneuver (VM). Furthermore, we wanted to investigate the patterns and mechanisms of physiological hemodynamic control. Method: Thirty six healthy college students were recruited from Y university. Each participant was provided with written informed consent. Blood pressure (BP), heart rate (HR), cardiac output (CO) were continuously recorded using the Finometer. Result: During the phase I of VM, means of systolic and diastolic pressures were increased by 32.15% and 38.28%, respectively, compared with basal values. HR and CO were decreased by 9.91% and 13.01%, respectively. Immediately after the maneuver (phase III), systolic and diastolic pressures were decreased by 5.05% and 6.24%, respectively, compared with those obtained in the phase II. HR and CO were elevated by 13.33% and 11.93%, respectively, compared to the levels of earlier phases. BPs were represented with overshoot in the phase IV, and recovered by baseline values about 20 sec after VM. Conclusion: These results demonstrated that hemodynamic changes are variable in the event of VM even in healthy humans. It will be valuable to accumulate more quantitative hemodynamic information in special populations such as the elderly and the patients with cardiovascular problems.

  • PDF

무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가 (Implementation and evaluation of the BCG measurement system for non-constrained health monitoring)

  • 노윤홍;정도운
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Bridge to Transplantation with a Left Ventricular Assist Device

  • Jung, Jae-Jun;Sung, Ki-Ick;Jeong, Dong-Seop;Kim, Wook-Sung;Lee, Young-Tak;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • 제45권2호
    • /
    • pp.116-119
    • /
    • 2012
  • A 61-year-old female patient was diagnosed with dilated cardiomyopathy with severe left ventricle dysfunction. Two days after admission, continuous renal replacement therapy was performed due to oliguria and lactic acidosis. On the fifth day, an intra-aortic balloon pump was inserted due to low cardiac output syndrome. Beginning 4 days after admission, she was supported for 15 days thereafter with an extracorporeal left ventricular assist device (LVAD) because of heart failure with multi-organ failure. A heart transplant was performed while the patient was stabilized with the LVAD. She developed several complications after the surgery, such as cytomegalovirus pneumonia, pulmonary tuberculosis, wound dehiscence, and H1N1 infection. On postoperative day 19, she was discharged from the hospital with close follow-up and treatment for infection. She received follow-up care for 10 months without any immune rejection reaction.

승모판막 수술에 따른 심전도 변화 (The Study on Electrocardiographic Changes after Mitral Valvular Replacement)

  • 여승동;임승평
    • Journal of Chest Surgery
    • /
    • 제24권4호
    • /
    • pp.421-427
    • /
    • 1991
  • Atrial fibrillation[Af] is closely related to thrombus in left atrium, systemic embolism, and loss of the contribution of atrial contraction to cardiac output. Therefore maintenance of sinus rhythm[SR] is undoubtedly hemodynamically superior to Af in the clinical course of mitral valvular disease especially in the unstable period immediately after surgery. In this article, the conversion rate and the factors influencing the conversion of Af to SR after surgery were studied. Ninety-three patients with mitral valvular replacement at Chungnam National University Hospital were analysed with electrocardiography before and after surgery during the period from June 1985 to June 1990. Eighty patients presented Af before surgery. Twenty-four[30Yo] of the patients were converted to SR[A group] and fifty six presented continuous Af after surgery[B group]. The duration of preoperative Af, preoperative left atrial dimension[LAD], preoperative functional status[NYHA classification] and cardiothoracic[CT] ratio were factors influencing the conversion of Af to SR after surgery. The mean preoperative duration of Af was 3.5$\pm$2.6yr in group A and 7.6$\pm$4.9yr in group B. The mean preoperative LAD was 53. 7$\pm$9.4mm in group A and 62.5$\pm$11.2mm in group B. Before surgery, eleven patients[46%] were belong to NYHA class I, II in group A and eight[14%] in group B. The preoperative CT ratio was 62$\pm$6% in group A and 69$\pm$8% in group B.

  • PDF