• Title/Summary/Keyword: Contamination process

Search Result 742, Processing Time 0.028 seconds

The Separation of Particulate within PFC Decontamination Wastewater Generated by PFC Decontamination (PFC 제염 후 발생된 제염폐액 내 오염입자의 제거)

  • Kim Gye-Nam;Lee Sung-Yeol;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho;narayan M.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.32-39
    • /
    • 2005
  • When PFC(Perfluorocarbonate) decontamination technology is applied to removal of radioactive contaminated particulate adhered at surface during the operation of nuclear research facilities, it is necessary to develop a filtration equipment to reuse of PFC solution due to high price, also to minimize the volume of second wastewater. Contaminated characteristics of hot particulate was investigated and a filtration process was presented to remove suspended radioactive particulate from PFC decontamination wastewater generated on PFC decontamination. The range of size of hot particulate adhered at the surface of research facilities measured by SEM was $0.1{\sim}10{\mu}m$. Hot particulate of more than $2{\mu}m$ in PFC contamination wastewater was removed by first filter and then hot particulate of more than $0.2{\mu}m$ was removed by second filter. Results of filter experiments showed that filtration efficiency of PVDF(Poly vinylidene fluoride), PP(Polypropylene), Ceramic filter was $95{\sim}97\%$. A ceramic filter showed a higher filtration efficiency with a little low permeate volume. Also, a ceramic of inorganic compound could be broken easily on experiment and has a high price but was highly stable at radioactivity in comparison of PVDF and PP of a macromolecule which generate $H_2$ gas in alpha radioactivity environment.

  • PDF

Assessment of Microbiological Quality of Cooked Dried-Seafoods in School Foodservice Operations (학교급식에서 제공되는 건포류 조리식품의 미생물적 품질평가)

  • Park, Heon-Guk;Ryu, Gyeong
    • Journal of the Korean Dietetic Association
    • /
    • v.12 no.2
    • /
    • pp.172-184
    • /
    • 2006
  • This study was aimed to provide safety management guidance by evaluating the microbial quality of cooked dried-seafoods in school foodservice operations. Nineteen seafood items were collected from six elementary schools, those were dried-anchovy, dried-seaweed and dried-fish, which were classified as cooking process. The temperatures at receiving and after cooking were measured and the analyses of cooking processes and microbial quality were performed. The temperatures of all foods after cooking were higher than the temperature limit of $74\^circC$. The number of total aerobic bacteria and S. aureus in dried-anchovy over the limit of $10^5$ and even the level of S. aureus was found to be unsatisfactory. The count of total aerobic bacteria was 2.1x$10^8$ CFU/g and the number of total aerobic bacteria after cooking was over the limit in one school. The level of E. coli (3.1x$10^3$ CFU/g) was over the limit at one school and the number of S. aureus (1.2×$10^4$ CFU/g) was considered as unacceptable. Dried- tangle and green laver were contaminated with total aerobic bacteria showing the over the limit. The numbers of total aerobic bacteria in dried- filefish, pollack and squid were 4.3x$10^6$, 3.4x$10^6$-3.9x$10^7$ and 4.6x$10^5$-4.1x$10^7$ CFU/g, respectively, which were in acceptable or unsatisfactory level. The E. coli in dried- filefish and pollack were over the limit. The total aerobic bacteria levels, 4.6x$10^5$-1.5x$10^6$ CFU/g in dried-pollack and 8.0x$10^5$-2.2x$10^7$ CFU/g in dried-squid, were over the limit after cooking except dried-filefish. The E. coli levels, 4.3x$10^3$ CFU/g in dried-filefish and 2.5x$10^2$ CFU/g in dried-pollack, were over the limit of $10^2$ CFU/g. The numbers of Enterobacteriaceae were either acceptable (3.3x$10^3$ CFU/g) or unsatisfactory (1.6x$10^4$ CFU/g) level in dried-pollack. S. aureus was unsatisfactory level (6.5x$10^4$ CFU/g) in dried-filefish while unacceptable in dried-pollack both before and after cooking. Unacceptable levels of S. aureus, 2.4x$10^4$ and 1.3x$10^5$ CFU/g were found from two schools, respectively. These results suggest that the contamination of raw materials and the seasonings added after cooking should be controlled to manage the microbial safety of cooked dried-seafoods.

  • PDF

Numerical and Experimental Investigation on the Interaction of Subsurface Vortical Flows with a Free Surface (수면하 보오텍스 유동과 자유표면과의 상호 작용에 관한 연구)

  • Mu-Seok Song
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.76-85
    • /
    • 1993
  • In order to predict the free surface signature of turbulent ship wakes two things are essential; a basic understanding of the mechanism of turbulent vortical flow/free surface interactions and a mathematical model to accurately predict the signature. The goal of the study described here is both to supplement experimental work to obtain basic understanding, as well as to condense this understanding in a model(or models) that captures the essential phenomena and thus allows predictions. To do so we followed two main paths guided by experimental observations. One is full simulations of the flow using the clavier-Stokes equations. The other is a vortex modeling, where the vortical structures of the flows are approximated by idealized structures, an the interaction assumed to be essentially inviscid. These approaches complement each other. Full simulations are only applicable to small scale phenomena, where the system is simple, and the Reynolds number is low. The vortex modeling, on the other hand, cannot represent essentially viscous aspects of the problem such as the effect of contamination gradient. Obviously, the modeling is what may eventually lead to a prediction method; the full simulations-too limited to mimic all but the simplest circumstances-are to aid and support the construction of realistic models. We address two-dimensional aspects of the vortex/free surface interaction first. Secondly we obtain some basic understanding of the interaction process through an experiment and then talk about several three-dimensional problems hoping to develop a successful prediction model.

  • PDF

A Design Study on Seoul CheongGye Plaza (서울 청계광장 설계 연구)

  • Shin, Hyun-Don
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.12-21
    • /
    • 2012
  • The proximities of Cheonggye creek was a maj or space for the gathering of large populations from the past times and it is also a place containing the joy, anger, sorrow, pleasure and lives of the citizens. The Cheonggye creek which flowed downtown of Seoul throughout many historical events had disappeared into history completely in the modernization process due to the contamination with life sewages and overflow. However, the city authority of Seoul decided to restore it to its shape before covering the creek by means of dismantling the old elevated ways in Cheonggye creek in line with the Large Scale City Movement Project to revive the grey city and to improve the quality of the city landscape in 2002. The cultural space was created by activating the old town sphere in Cheonggye Creek and the amenities of the giant city was improved by the cultural and natural wave created along the creek. In addition, the educational opportunity has been provided to the citizens by means of reviving its historical nature. The design and cultural value of the Cheonggye Plaza were restored for the mean time and the urban environment requested during modem times was established. The Cheonggye Plaza which heightened the balanced development in Seoul which has been developed in an unbalanced way by dividing into northern and southern area of the river is very meaningful in the viewpoint of the landscape architect who designs the urban space. The re-birth as a cultural space of downtown owing to the efforts of the said cultural catalysts is meaningful.

Detection of Enterococci and their Vancomycin Resistance in Drinking Spring-Water (먹는물 약수터 장구균의 검출 특성과 반코마이신 내성 현황)

  • Yoon, Tae-Ho;Lee, Hyang;Lee, Seung-Joo;Yeo, In-Hak;Eom, Seok-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.979-985
    • /
    • 2010
  • This study was performed to detect enterococci strain as an indicator of faecal contamination, to identify of 16S rDNA sequence and vancomycin resistance by MIC (Minimum Inhibitory Concentration) test from drinking spring-water samples in Seoul. The detection frequency of enterococci was 42 (19.8%) among 212 samples, and its concentration was ranged from 0 to 110 CFU/100 mL. These results were confirmed the possibility as an indicator microorganisms that similar to the frequency of E. coli detection (t test p-value 0.268, significant level 0.05). Isolated 56 enterococci samples were identified by 16S rDNA sequence data and their NCBI BLAST searching. They were identified to Enterococcus faecalis of 24 samples, E. faecium (10), E. casseliflavus (10), E. gallinarum (3), E. hirae (2), E. durans (2), E. sanguinicola (1). E. faecalis was dominant species that clinical case report of a domestic was similar. Vancomycin resistant enterococci (VRE) of 53 samples showed that vanB and vanC1/C2 type with 2 and 12 case, respectively. These results indicated that the drinking spring-water quarantined to fecal pollution for block out outbreak of gastrointestinal symptom with using such as disinfection process.

Petrochemical Study on the Cretaceous Volcanic Rocks in Kyeongsang Basin, Korea: Possibility of Magma Heterogeneity (경상분지 백악기 화산암류에 대한 암석화학적 고찰: 이원성 마그마의 가능성)

  • Sung, Jong Gyu;Kim, Jin Seop;Lee, Joon Dong
    • Economic and Environmental Geology
    • /
    • v.31 no.3
    • /
    • pp.249-264
    • /
    • 1998
  • The Creataceous volcanic rocks distributed in the southeastern part (Kyeongsang basin) of Korea peninsula are composed of basalt, basaltic andesite, andesite, dacite and rhyolite. The variation of major elements show that contents of MgO, CaO, $FeO^T$, $Al_2O_3$, $TiO_2$ and $P_2O_5$ decrease with increasing of $SiO_2$, but $K_2O$ contents are increased slightly, $Na_2O$ widely dispersed. We can show slightly inflection point and low frequency of dacites in range between 63-65 wt.% $SiO_2$, while continuous trend exit in variation diagram. Variation trends in Harker diagrams for the major, minor, trace and REEs suggest that the BAV (basaltic to andesitic volcanics) and DRV (dacitic to rhyolitic volcanics) are not related to a simple crystal fractionation process. In the regime of under 65 wt. % in silica content, fractionation of olivine and clinopyroxene is predominant, while that of plagioclase happens strongly higher than 65 wt.% (e.g., $SiO_2$, vs. Eu and Sr, MgO vs. $Al_2O_3$ and CaO). The latter means low-pressure fractional crystallization for DRV. On the discriminant diagram, DRV are located in more mature environment than BAV. The $(Ce/Sm)_N$ vs. CeN digram shows that these two classes cannot be related to crystal fractionation. If they had been produced by fractionation, although they plotted in a slightly elongate cluster along the same horizontal trend, DRV should lie to the right of these primitive compositions. These diagrams clearly rule out a simple fractionation throughout from BAV to DRV. BAV had been influenced greatly subductiong slab as shown by K/Yb vs. Ta/Yb. We suggest that BAV primitive magma generated higher degree of partial melting than DRV primitive magma. LILE (K, Ba, $Rb{\pm}Th$) enriched characteristics as shown in BAV are inherited from subducting slab fluids and/or higher degree of partial melting of mantle material. However, lower degree of partial melting of mantle relative to BA V and contamination at high-level magma reservoir caused LILE enrichment to DRV.

  • PDF

A Study on the Real-Time Oil-Spill Monitoring Technology (실시간 기름유출 모니터링 기술에 관한 연구)

  • Yeom, Woo-jung;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.472-477
    • /
    • 2017
  • Oil spills cause a lot of damage to the environment. Oil destroys the water environment and ecosystem in a very short period of time once they are contaminated by it, it takes a lot of time to recover from the contamination and the cleaning process is very difficult. Therefore, oil detectors are greatly needed as they can monitor any oil spills over the sea, rivers, and lakes. There are two kinds of technology available for detecting oil, viz. the contact and non-contact types. The former is based on the use of the conductivity, capacitance and microwaves, while the latter employs infrared, UV, laser, optic and radar technologies. As there are also various hurdles in the measuring of oil on water, such as the presence of waves, refraction of light, temperature and saltiness, it is imperative to select the right oil detector which is appropriate for the specific environment. In this study, a contact type oil detector is developed, which can be used in oil related industries, such as refineries, petrochemical companies, and power generation stations. The detector is made up of the sensor module, which floats on the water, and the controller which processes the signal coming from the sensor module and displays it. It is designed in such a way that the existence of oil is detected through the sensor and the change in the permittivity is observed to determine the volume and type of spilled oil.

Development of a Hospital Foodservice Facility Plan and Model based on General Sanitation Standards and RACCP Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설모델 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.477-492
    • /
    • 2003
  • The purposes of the study were to establish HACCP-based standards and guidelines for conducting a plan review to build, or renovate, hospital food service establishments, and ensure the safety of foodservice and reduce the risk of food borne illness. The scope of the study included suggestion for the planning of hospital foodservice facilities: layout, design, equipment and modeling. The results of this study can be summarized as follows: 1) The development of a foodservice facility plan based on the results of a survey, literature reviews and the results of interviews with foodservice managers from 9 general hospitals. This was composed of operational policies in foodservices, layout characteristics, space allocation, selection, design, specification standards for equipment and the construction principles of foodservice facilities. 2) Two foodservice facility models were developed, one for general hospitals with 900 beds (2,000 patients and 2,500 employee meals per day) and the other for general hospitals with 300 beds (600 patients and 650 employees meals per day). 3) The suggested kitchen space requirements for the foodservice facility models were 341.2 ㎡ (W 17,100mm x L 23,700mm) and 998.8㎡ (W 35,600mm x L 32,800mm) for the 300 and 900 beds hospitals, respectively, with both designs being rectangular. The space requirements for the equipment, in relation to the total operational area, in terms of ratios were 1:3.5 and 1:3.8 for the 300 and 900 beds hospitals, respectively. The recommended space allowances per bed for the developed foodservice facility models were 1.15 ㎡ and 1.11 ㎡ for the 300 and 900 beds hospitals, respectively, which were increased by more than 30% compared to those suggested in the precedent study, and considered appropriate for the implementation of the HACCP system. 4) The hospital foodservice facilities plans and models were developed based on the general sanitation standards, guidelines and the HACCP system, and included foodservice facility layout, product flow, physical separation between contaminated and sanitary areas, foodservice facility specifications with a 1/300 scale for a 300 bed, and a 1/400 scale for a 900 beds blueprint. 5) The main features of the developed foodservice facility plans and models were; physical separation between contaminated and sanitary areas to prevent cross contamination, product flow in one direction from the arrival of the raw material to the finished product, and separation of different work areas and the process of receiving & preparation of products, refrigeration & storage, cooking, assembly, cleaning & disinfection, employee areas and janitorial facilities. The proposed models from this study were presented as examples for those wanting to build, or renovate, their facility for the production of foods.

Evaluation of Biological Critical Control Points Using Escherichia coli Genotyping (Escherichia coli Genotype을 이용한 생물학적 Critical Control Point의 적합성 평가)

  • Kim, Hak-Jae;Hahn, Tae-Wook;Juong, Ji-Hun;Bahk, Gyung-Jin;Hong, Chong-Hae
    • Food Science of Animal Resources
    • /
    • v.29 no.6
    • /
    • pp.695-701
    • /
    • 2009
  • This study was performed to evaluate the effectiveness of biological critical control points using the genetic profile of Escherichia coli isolates from pork cutting plants. Samples were collected from carcasses, equipment (knife, table, glove, transport belt, boning and skinning machine), the environment (wall and floor), and meat cuts during the cutting process from two plants. Pulsed-field gel electrophoresis (PFGE) was used to characterize the E. coli isolates. An identical genotype was detected from the carcasses, equipment, environment, and final meat cuts, and showed that the incoming carcasses, which were contaminated during transportation from slaughterhouses, were a major source of E. coli that was spread throughout processing. Also, consistent cross-contamination due to improper cleaning and disinfection procedures was another possibility. As a result, incoming carcasses and cleaning procedures should be considered critical control points in pork cutting plants, since a heating step is not used to inactivate microorganisms. Furthermore, the high rate (59.6%) of E. coli isolation indicates E. coli can be a good indicator in livestock processing plants even though it has genetic diversity.

The Uranium Removal in Groundwater by Using the Bamboo Charcoal as the Adsorbent (대나무 활성탄을 흡착제로 활용한 오염지하수 내 우라늄 제거)

  • Lee, Jinkyun;Kim, Taehyoung;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.51 no.6
    • /
    • pp.531-542
    • /
    • 2018
  • Batch sorption experiments were performed to remove the uranium (U) in groundwater by using the bamboo charcoal. For 2 kinds of commercialized bamboo charcoals in Korea, the U removal efficiency at various initial U concentrations in water were investigated and the optimal sorption conditions to apply the bamboo charcoal were determined by the batch experiments with replicate at different pH, temperature, and reaction time conditions. From results of adsorption batch experiments, the U removal efficiency of the bamboo charcoal ranged from 70 % to 97 % and the U removal efficiency for the genuine groundwater of which U concentration was 0.14 mg/L was 84 %. The high U removal efficiency of the bamboo charcoal maintained in a relatively wide range of temperatures ($10{\sim}20^{\circ}C$) and pHs (5 ~ 9), supporting that the usage of the bamboo charcoal is available for U contaminated groundwater without additional treatment process in field. Two typical sorption isotherms were plotted by using the experimental results and the bamboo charcoal for U complied with the Langmuir adsorption property. The maximum adsorption concentration ($q_m:mg/g$) of A type and C type bamboo charcoal in the Langmuir isotherm model were 200.0 mg/g and 16.9 mg/g, respectively. When 2 g of bamboo charcoal was added into 100 mL of U contaminated groundwater (0.04 ~ 10.8 mg/L of initial U concentration), the separation factor ($R_L$) and the surface coverage (${\theta}$) maintained lower than 1, suggesting that the U contaminated groundwater can be cleaned up with a small amount of the bamboo charcoal.