• Title/Summary/Keyword: Contamination evaluation

Search Result 462, Processing Time 0.025 seconds

Microbial Contamination of the Food Materials for Manufacturing Korean Laver Roll (Kimbab) and the Effect of Gamma Irradiation

  • Jo, Cheo-Run;Lee, Na-Young;Hong, Sang-Pil;Kim, Young-Ho;Byun, Myung-Woo
    • Preventive Nutrition and Food Science
    • /
    • v.9 no.3
    • /
    • pp.236-239
    • /
    • 2004
  • Microbial contamination of ready-to-eat ingredients for Kimbab manufacturing and the effect of irradiation to reduce the microbial contamination of the products were investigated. Among 9 food items tested, there were no viable cells in the ham, seasoned and cooked beef, imitation crab leg, fried egg, and seasoned burdoc. Cucumber, surimi gel, and seasoned and blanched spinach were counted at 5.07$\pm$0.97, 3.50$\pm$0.14, and 5.41$\pm$0.51 log CFU/g, respectively. Irradiation at 1 kGy reduced the number of microorganism in these ready-to-eat foods to an undetectable level. However, the dried laver showed an 8.83$\pm$0.10 log CFU/g and an irradiation at 3 kGy reduced the level to only 7.14$\pm$0.23. Sensory evaluation of the irradiated Kimbab prepared from these food materials indicated that the measure of the control of the sensorial quality should be provided before applying an irradiation to the prepared Kimbab.

Evaluation of Minimum Detectable Activity for Underwater Radiation Monitoring System (수중 방사선 모니터링 시스템의 성능평가를 위한 수중 내 최소검출가능농도 산출)

  • Jangguen Park;Sung-Hee Jung;Daemin Oh;Jinho Moon
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.219-224
    • /
    • 2023
  • A high-efficiency underwater radiation monitoring system, HydroGamma, has been developed for detecting 137Cs and 131I in the event of waterborne radiation contamination. The system consists of a 3-inch NaI (Tl) detector, solar panels for power supply, data acquisition and transmission modules, and batteries. HydroGamma also includes a 40K calibration source for remote performance evaluation and energy calibration. In this study, some simulations and experiments were carried out to evaluate the minimum detectable activities (MDA) of HydroGamma. We installed the HydroGamma at Tapjeongho Lake in Nonsan-si and acquired background data since MDA is calculated based on the experimental background data. The results show that the minimum detectable activities for 137Cs and 131I were 1.78Bq L-1 and 1.81Bq L-1, respectively even though the gamma rays emitted from 40K(1,460 keV) affect the minimum detectable activities for them.

Evaluation of the Level of microbial Contamination in the Processing Company of Nuroong-ji (누룽지 생산시설에 대한 미생물학적 오염도 평가)

  • Do, Yu-No;Choi, Jeong-Sik;Jung, Yu-Kyung;Park, Ji-Hyun;Roh, Kyong-Hwan;Kim, Sung-Soo;Choi, Shin-Young;Lee, Kyoung-Yun;Han, Eui-Jeong
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.333-340
    • /
    • 2010
  • This study was conducted to evaluate the microbial contamination levels in the processing company of Nuroong-ji. Microbial contamination levels were examined for sanitary indication bacteria such as aerobic plate count, coliforms and fungi, and pathogenic bacteria such as Escherchia coli O157:H7, Salmonella spp., Staphylococcus aureus, and Listeria monocytogenes. Contamination levels were detected differently according to handling materials and purposing work-space. The equipments and raw materials were not seriously contaminated but there were necessary to attend the cross-contamination. A high contamination level was detected at the process where the interference of the employees was relatively higher than the other process. Standardization of the roasting process (l20~$170^{\circ}C$, about 10 min) could be necessary to control the microbial organism effectively on Nuroong-ji manufacturing process. At small/medium size foodstuff manufacturers, it is the most important to improve the recognition level of individual hygiene but also expand a hygiene facility.

Analysis of contamination characteristics of filter cloth in filter press by repeated dehydration of organic sludge and evaluation of ultrasonic cleaning application (유기성 슬러지 반복 탈수에 의한 필터프레스 여과포 오염 특성 분석 및 초음파 세척 적용 평가)

  • Eunju Kim;Cheol-Jin Jeong;Kyung Woo Kim;Tae Gyu Song;Seong Kuk Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.2
    • /
    • pp.15-25
    • /
    • 2024
  • In this study, the regeneration effect of pressurized water and ultrasonic cleaning was investigated for contaminated filter cloth from the sewage sludge filter press process. For this purpose, contaminated filter cloth was collected from a 3-ton sewage sludge hydrothermal carbon treatment filter press. First, the contamination characteristics were analyzed. According to the location of the filter cloth, air permeability and unit mass were measured, and compared with the values of a new filter cloth. Next, the results were mapped over the entire area to evaluate the contamination characteristics. Finally, pressure cleaning at 3 bar and ultrasound at frequencies of 34, 76, 120, and 168 kHz were performed on the contaminated filter cloth. In addition, the cleaning efficiency was evaluated by 3 levels of contamination degree. As a result, pore contamination occurred mainly at the bottom and both sides of the filter cloth, where the filter material was continuously injected and compressed. Surface contamination appeared evenly over the entire area. As a result of washing, air permeability increased by 1.3-3.1%p and contaminant removal was by 2.7-4.4% under pressure. In ultrasonic cleaning, air permeability increased by 12.5-61.5%p and contaminants were removed by 2.7-29.2%. In ultrasonic cleaning the lower the frequency, the higher air permeability and contaminant removal rate. Also, The higher pore contamination level, the better the air permeability improvement and contaminant removal.

Development of Particle Deposition System for Cleaning Process Evaluation in Semiconductor Fabrication (반도체 세정 공정 평가를 위한 나노입자 안착 시스템 개발)

  • Nam, Kyung-Tag;Kim, Ho-Joong;Kim, Tae-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3168-3172
    • /
    • 2007
  • As the minimum feature size decreases, control of contamination by nanoparticles is getting more attention in semiconductor process. Cleaning technology which removes nanoparticles is essential to increase yield. A reference wafer on which particles with known size and number are deposited is needed to evaluate the cleaning process. We simulated particle trajectories in the chamber by using FLUENT and designed a particle deposition system which consists of scanning mobility particle sizer (SMPS) and deposition chamber. Charged monodisperse particles are generated using SMPS and deposited on the wafer by electrostatic force. The experimental results agreed with the simulation results well in terms of particle number and deposition area according to particle size, flow rate and deposition voltage.

  • PDF

Development of Particle Deposition System for Cleaning Process Evaluation in Semiconductor Fabrication (반도체 세정 공정 평가를 위한 나노입자 안착 시스템 개발)

  • Nam, Kyung-Tag;Kim, Young-Gil;Kim, Ho-Joong;Kim, Tae-Sung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.49-52
    • /
    • 2007
  • As the minimum feature size decrease, control of contamination by nanoparticles is getting more attention in semiconductor process. Cleaning technology which removes nanoparticles is essential to increase yield. A reference wafer on which particles with known size and number are deposited is needed to evaluate the cleaning process. We simulated particle trajectories in the chamber by using FLUENT. Charged monodisperse particles are generated using SMPS (Scanning Mobility Particle Sizer) and deposited on the wafer by electrostatic force. The Experimental results agreed with the simulation results well. We calculate the particles loss in pipe flow theoretically and compare with the experimental results.

  • PDF

Studies on the Contamination Degree of Effluent from the Sewage Purification System and Septic Tank (오수정화시설 및 정화조 방류수의 수질오염도에 관한 연구)

  • 어수미;이홍근
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.35-40
    • /
    • 1991
  • This study was performed to investigate the contamination degree of effluent from the sewage purification system and septic tank. The 711 samples, were collected from the large size tank located in Seoul from Mar. to June 1991. The results were as follows 1. The pH values of effluent were largely neutral of 6.96 in sewage and 7.43 in septic tank. 2. The average concentration of BOD was 48.18 mg/l in sewage and 127.0 rng/l in septic tank. 3. The average concentration of SS was 40.8mg/l in sewage and 90.5rng/l in septic tank. 4. In the analysis of nutrient salts, the average concentration of NH$_{3}$-N was 31.62mg/l in sewage and 88.79 mg/l in septic tank. 5. In the analysis of correlation among items, BOD, SS, NH$_{3}$-N and PO$_{4}$-P were higly correlated beween items. 6. As a results of above analysis, it is considered as desirable evaluation method of effluent not through the only item but through the integrated items.

  • PDF

Evaluation of Natural Attenuation of Petroleum Hydrocarbons in a Shallow Sand Aquifer: a Modeling Study (자연저감 모델링 연구)

  • 이진용;이명재;이강근;이민효;윤정기
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.128-131
    • /
    • 2001
  • We evaluated natural attenuation of petroleum hydrocarbons in a shallow aquifer using a modeling study. The studied shallow aquifer was severely contaminated with petroleum hydrocarbons, especially toluene, ethylbenzene and xylenes (i.e, TEX). The exact spill history was not known. Therefor we used a contaminant level in May 1999 (the first sampling date of our integrated study) as an initial contaminant concentration. we calibrated required transport parameters using the contamination levels obtained from groundwater analyses in September of 1999. For fate and transport of the petroleum contaminants, five case 2 with sorption and degradation. case 3 with sorption and degradation (half decay constant compared with case 2), case 4 with degradation but no sorption, and case 5 with sorption but no degradation. For sorption and degradation, a linear sorption isotherm and first order irreversible decay was assumed, respectively and no additional contamination source to groundwater is also assumed.

  • PDF

Melamine testing of meat, eggs and diary products sold in Incheon

  • Ra, Do-Kyung;Hong, Seong-Hee;Lee, Jeong-Gu;Lee, Sung-Mo
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.4
    • /
    • pp.381-383
    • /
    • 2009
  • From Oct. 2008 to Oct. 2009, 619 livestock products sold in Incheon were examined for melamine contamination. HPLC was used to detect the melamine concentration from various products. $C_{18}$ column $(3.9\times150mm,\;4{\mu}m)$ was applied with a phase composed of 10mM citric acid and 10mM sodium octane sulfonate : acetonitrile (in ratio 90:10) pumped isocratically at 1.0ml/min. Melamine was not detected from any of the products at the level of LOD 0.03mg/kg and LOQ 0.08mg/kg, suggesting that no melamine contamination was ascertained in livestock products in Incheon area. However, further tests should be done to detect other melamine analogues for the evaluation of toxicity and safety of melamine and cyanuric acid in the future.

Sampling and Analysis of Particles Generated in CSS-Mode of a Hard Disk Drive by Using a Particle Sampler (입자 샘플러를 이용한 하드디스크 CSS 동작 시 발생한 입자 샘플링 및 분석)

  • Lee Jae ho;Lee Dae Young;Kim Sang Yoon;Hwang Jung ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.599-608
    • /
    • 2005
  • Controlling particle contamination is important to increase storage capacity as the flying height of a slider in a hard disk drive decreases. Since precise detection and analysis of particles are primary steps of particle control in a HDD, many researchers have used sampling methods. In this paper, we newly designed a particle sampler and conducted performance evaluation of the sampler. Also, we conducted particle sampling from the HDD using the particle sampler and analysis of sampled particles by SEM and AES. Experimental results show that the particles generated by the slide-disk interaction mainly came from the disk surface.