• Title/Summary/Keyword: Contamination Control

Search Result 898, Processing Time 0.03 seconds

Studies on the HACCP Model of Steak-Set Menu in Hotel (HACCP 모델 적용시 호텔 .레스토랑의 세트 메뉴 중 스테이크에 관한 연구)

  • 양신철
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.12 no.1
    • /
    • pp.5-24
    • /
    • 2001
  • This study was focused on the sanitary analysis of hazard factors and the establishment of critical control points on steak-set menu In hotel by the documents and microbiological investigation. The hazard factors of shrimp cocktail were microbial contamination, residual pesticides, unsuitable healing and cross contamination. The hazard factors of potato soap were residual pesticides, microorganisms contamination, unsuitable heating and solanine in potato. The hazard factors of simple salad were microorganisms contamination, unsuitable heating and cross contamination by inappropriate package. The hazard factors of steal were residual antimicrobial drugs, microorganisms contamination, unsuitable heating and cross contamination. The critical control points of shrimp cocktail were temperature control , number of washing and center temperature control of heating step. The critical control points of potato soup were stock temperature control , number of washing and center temperature control of Heating step. The critical control points of simple salad were number of washing and dryness of utensil. The critical control points of steak were stock temperature control , number of washing, center temperature and time control of heating step.

  • PDF

Contamination Control of Optical Observation Satellite

  • Lee, Chang-Ho;Lee, Choon-Woo;Cho, Young-Jun;Whang, Do-Soon
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.28.3-28.3
    • /
    • 2008
  • Contamination has the potential for degrading the performance of the optical payload beyond the limits defined by mission requirements, therefore it must be considered a risk to system performance and must be mitigated. To mitigate contamination problem, contamination budget is allocated according to the contamination requirements which is derived from contamination effect analysis. Once the contamination budget is allocated, prediction for on-ground and in-orbit contaminants amounts and cleanliness control is performed. In this article, typical contamination control for observation satellite is described.

  • PDF

Contamination measurement, Analysis & Control for Satellite (인공위성의 오염 측정, 분석 및 관리)

  • Lee, Sang-Hoon;Hong, Seok-Jong;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • It is necessary to be careful about contamination control to minimize the accumulation of the contamination material on satellite surface during the I&T phase. In the space environment which characterized by high vacuum, high and very low temperature, contamination material causes satellite to lose its own performance. Especially, contamination material can accumulate on critical surfaces such as lenses, mirrors, and sensors. KARI(Korea Aerospace Research Institute) conducts the clean room to control and minimize the contamination effect. This paper introduces the principle of contamination and the method of measure and analysis for the contamination.

Cleanroom Contamination Control using Particle Composition Analysis (입자 성분분석을 통한 클린룸 오염제어)

  • Lee, Hyeon-Cheol;Kim, Dae-Young;Lee, Seong-Hun;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2333-2337
    • /
    • 2007
  • The practical studies on the method of particle contamination control for yield enhancement in the cleanroom were carried out. The method of the contamination control was considered, which is composed of data collection, data analysis, improvement action, verification, and implement control. The composition analysis for data collection and data analysis was used in the cellular phone module packaging lines. And this method was evaluated by the variation of yield loss between before and after improvement action. In case that the composition analysis was applied, the critical sources were selected and yield loss reduction through improvement actions was also investigated. From these results, it is concluded that the composition analysis is effective solutions for particle contamination control in the cleanroom.

  • PDF

Particle Contamination Control in the Cleanroom Production Line using Partition Check Method (클린룸 제조공정에서 공정분할평가법을 이용한 입자오염제어)

  • Lee, Hyeon-Cheol;Park, Jung-Il;Lee, Seong-Hun;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2338-2343
    • /
    • 2007
  • The practical studies on the method of particle contamination control for yield enhancement in the cleanroom were carried out. The method of the contamination control was proposed, which are composed of data collection, data analysis, improvement action, verification, and implement control. The partition check method for data collection and data analysis was used in the cellular phone module production lines. And this method was evaluated by the variation of yield loss between before and after improvement action. In case that the partition check method was applied, the critical process step was selected and yield loss reduction through improvement actions was observed. From these results, it is concluded that the partition check method is effective solution for particle contamination control in the cleanroom production lines.

  • PDF

Ecological study for The control of Green Contamination in Korean Show Caves

  • Kim, Byoung-Woo
    • Journal of the Speleological Society of Korea
    • /
    • no.85
    • /
    • pp.21-24
    • /
    • 2008
  • The chlorophyta and thebryophyta are became extinct by the shutting out the light and low temperature in caves. Whenever they get the conditions, they grow again immediately. It is necessary to keep the illumination distance over 2m and use the indirect light. The effect of lamp light and temperature is very important in the control of green contamination but the water and moisture in caves are essential factors in green contamination in the show caves. It's better to get rid of green alae and mosses at early stage for the control of the increase of green contamination. They must be isolated completely without the dispersion with moist pieces of cloth or sponge. It is necessary to shut out the cave route periodically for the restoration of cave environments and ecosystem. It's better to use the lamp keeping illumination and restricting the ascension of heat for the control of green contamination.

Experimental Study on Fabrication of AZO Transparent Electrode for Organic Solar Cell Using Selective Low-Temperature Atomic Layer Deposition (저온 선택적 원자층 증착공정을 이용한 유기태양전지용 AZO 투명전극 제조에 관한 실험적 연구)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Kang, Jeong-Jin;Hwang, Jun-Young;Lee, Sang-Ho;Kang, Kyung-Tae;Kang, Heui-Seok;Cho, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.577-582
    • /
    • 2013
  • AZO (aluminum-doped zinc oxide) is one of the best candidate materials to replace ITO (indium tin oxide) for TCOs (transparent conductive oxides) used in flat panel displays, organic light-emitting diodes (OLEDs), and organic solar cells (OSCs). In the present study, to apply an AZO thin film to the transparent electrode of an organic solar cell, a low-temperature selective atomic layer deposition (ALD) process was adopted to deposit an AZO thin film on a flexible poly-ethylene-naphthalate (PEN) substrate. The reactive gases for the ALD process were di-ethyl-zinc (DEZ) and tri-methyl-aluminum (TMA) as precursors and H2O as an oxidant. The structural, electrical, and optical characteristics of the AZO thin film were evaluated. From the measured results of the electrical and optical characteristics of the AZO thin films deposited on the PEN substrates by ALD, it was shown that the AZO thin film appeared to be comparable to a commercially used ITO thin film, which confirmed the feasibility of AZO as a TCO for flexible organic solar cells in the near future.

Method of Particle Contamination Control for Yield Enhancement in the Cleanroom (클린룸 제조공정에서 수율개선을 위한 입자오염제어 방법)

  • Noh, Kwang-Chul;Lee, Hyeon-Cheol;Kim, Dae-Young;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.6 s.261
    • /
    • pp.522-530
    • /
    • 2007
  • The practical studies on the method of particle contamination control for yield enhancement in the cleanroom were carried out. The method of the contamination control was proposed, which are composed of data collection, data analysis, improvement action, verification, and implement control. The partition check method and the composition analysis for data collection and data analysis were respectively used in the main board and the cellular phone module production lines. And these methods were evaluated by the variation of yield loss between before and after improvement action. In case that the partition check method was applied, the critical process step was selected and yield loss reduction through improvement actions was observed. While in case that the composition analysis was applied, the critical sources were selected and yield loss reduction through improvement actions was also investigated. From these results, it is concluded that the partition check and the composition analysis are effective solutions for particle contamination control in the cleanroom production lines.

Characteristics of Groundwater Contamination in Uncontrolled Landfill and Pollution Control Measures (불량 매립지에서의 지하수 오염특성과 환경오염 방지방안)

  • 구자중;윤석표
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.05a
    • /
    • pp.28-44
    • /
    • 1993
  • Remediation actions in uncontrolled landfill site should be conducted after the investigation of contamination status and potential health risk or damage. Based on the above, proper control measures should be established and operated. Also continuous monitoring should be followed. In this study, the status of ground water contamination around Nanji Landfill Site was investigated. Monitoring wells were installed around the landfill and ground water was sampled once a month and analyzed. Water quality of each monitoring well was different depending on the horizontal and vertical distance from the landfill, and the seasonal leachate characteristics were not significantly changed because percolating water stayed long time in the deep waste layer. It was predicted that major multivalent cations were mainly precipitated as metal carbonate form, and chemical mass balances (CMBs) could be applied for the apportionment of leachate contamination to ground water quality of surrounding areas of Nanji Landfill. Parameters required to estimate pollutant flux to the receptor near landfill were listed and discussion to get these parameters was made. Finally, based on the above data, control measures of ground water contamination were suggested and discussed.

  • PDF