• Title/Summary/Keyword: Contaminated surface

Search Result 688, Processing Time 0.02 seconds

Chemical Speciation of Arsenic in the Water System from Some Abandoned Au-Ag Mines in Korea (국내 폐금은광산 주변 수계내의 As의 화학적 특성)

  • 이지민;이진수;전효택
    • Economic and Environmental Geology
    • /
    • v.36 no.6
    • /
    • pp.481-490
    • /
    • 2003
  • The objectives of this study are (1) to determine the extent and degree of As contamination of the water and sediments influenced by mining activity of the abandoned Au-Ag mines, (2) to examine As speciation In contaminated water, (3) to monitor variation of As contamination in water system throughout the dry and wet seasons, and (4) to investigate the As chemical form in the sediments through the sequential extraction analyses. Natural water(mine water, surface water and groundwater) and sediments were collected in six abandoned Au-Ag mine(Au-bearing quartz veins) areas. The contamination level of As in mine water of the Dongil(524${\mu}m$/L) is more higher than the tolerance level(500 ${\mu}m$/L) for waste water of mine area in Korea. Elevated levels of As in stream water were also found in the Dongil(range of 63.7∼117.6 ${\mu}m$/L.) and Gubong(range of 56.1∼62.9 ${\mu}m$/L) mine areas. Arsenic contamination levels in groundwater used by drinking water were more significant in the Dongil(11.3∼63.5 ${\mu}m$/L), Okdong(0.2∼68.9 ${\mu}m$/L) and Gubong(2.0∼101.0${\mu}m$/L) mine areas. Arsenate[As(V), $H_2AsO_4^-$] is more dominant than arsenite[As(III), $H_3AsO_3$] in water system of the most mine areas. The concentration ratios of As(III) to As(total), however, extend to the 95% in stream water of the Okdong mine area and 70∼82% in groundwater of the Okdong and Dongjung mine areas. As a study of seasonal variation in the water system, relatively high levels of As from the dongil mine area were found in April rather than in September. Sequential extraction analysis showed that As was predominantly present as coprecipitated with Fe hydroxides from sediment samples of the Dongjung and Gubong mine(35.9∼40.5%), which indicates its possibility of re-extraction and inducing elevated contamination of As in the reductive condition. In sediments from the Dongil, Okdong and Hwachon mine area, high percentage(55.2∼83.4%) of As sulfide form was found.

Number of intrauterine eggs in female Enterobius Mermicularis by body length (요충 자충의 길이별 보유 충란수)

  • Jo, Seung-Yeol;Jang, Im-Won;Jang, Hyeon-Jeong
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.2
    • /
    • pp.253-259
    • /
    • 1985
  • In order to correlate the number of eggs In female Enterobius vermicularis with their body length and to re-evaluate the number of eggs liberated by gravid females, a total of 203 worms were examined. Those females were removed from naturally infected orphans with mebendazole (100mg) and had been fixed in 10% formalin(Cho et al., 1981). The decent ones which were selected under dissecting microscope were unbroken, neatly fixed females without contaminated eggs on their surface. The worms were measured by their body length, softened in 0.1N NaOH solution overnight, and teased by dissecting needles. And their number of shelled eggs was measured in a counting chamber made as described by Denham et at. (1971). The results were summarized as follows: 1. The observed females, 4.10~9.90mm long, began to have shelled eggs in uterus when body length was 5.50mm or longer. 2. The percentage of females with eggs in uterus was as follows by range of body length: 25% in 5.50~5.99mm long, 53.3% in 6.00~6.49mm long, 86.7% in 6.50~6.99mm long, 95.2% in 7.00~7.49mm long and 100% in 7.50mm or longer. 3. The mean and standard deviation of egg number were as follows by the length of females: $19{\pm}50$ in 5.50~5.99mm long, $734{\pm}1,597$ in 6.00~6.49mm long, $1,473{pm}1,606$ in 6.50~6.99mm long, $1,530{\pm}2,055$ in 7.00~7.49mm long, $2,567{\pm}2,046$ in 7.50~7.99mm long, $5,598{\pm}2,470$ in 8.00~8.49mm long, $9,318{\pm}2,651$ in 8.50~8.99mm long, $10,678{\pm}2,892$ in 9.00~9.49mm long and $13,323{\pm}1,778$ in 9.50~9.90mm long. 4. The numbers of uterine eggs showed greater individual variation when the female lengths were in range of 5.5~8.0mm. When the female length was longer than 9.0mm, the egg numbers were over 10,000 in majority, and showed lesser individual variations. Above results su99ested that the e99 Production in female 5. vermicularis began in 28~32 days after infection and that in early stapes, the egg Production varied by individual worms, but in gravid females longer than 9. Qmm at last deposited 10,000 to 16,000 eggs in their uterus with the least individual variations.

  • PDF

The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive (Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향)

  • Kim, Yu-Shin;Lee, Hyung-Soon;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.439-447
    • /
    • 2004
  • The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.

Characteristic Assessment of Heavy Metals in Dusts Collected by the Air Filtration System at Subway Stations in Daegu, Korea (대구지역 지하철역사 공기여과필터 포집먼지에 함유된 중금속성분의 특성평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Shin, Dong-Chan;Kwak, Jin-Hee;Lee, Myoung-Sook;Yoon, Ho-Suk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Samples of subway dust were collected by the air filter system of 30 subway stations on Daegu subway line 1 in January 2008. Samples were sieved below 100 ${\mu}m$, and 14 elements were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic sources were significantly affected by indoor dusts than outdoor dusts. Results of pollution indices of heavy metals indicated that indoor dusts were more contaminated with heavy metal ions than outdoor dusts. The correlation analysis among trace elements indicated that components were much correlated in the order of natural sources-anthropogenic sources, anthropogenic sources-anthropogenic sources, natural sources-natural sources in both indoor and outdoor dusts. Trace element components of outdoor dusts were largely correlated than those of indoor dusts. In addition, indoor dusts were significantly affected by outdoor dusts rather than depth from the surface or the average daily number of subway passengers.

Fenton-like Reaction for Treatment of Petroleum-Contaminated Silty Clay after Soil Washing Process (토양세척 후의 유류 오염 Silty Clay 처리를 위한 유사펜톤 산화반응)

  • So, Myung-Ho;Ha, Ji-Yeon;Yu, Jae-Bong;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • This research was performed to assess a Fenton-like oxidation using naturally present iron in the field to treat remained oils throughout silty clay residues which finally resided even after a series of soil washing process. Biodegradability was thus tested for reaction products to investigate a possible treatment of the Fenton-like oxidation coupled with a biological treatment process. For those purposes, two types of field soil samples (e.g., dewatered cake after conditioning with a polymer and not-dewatered residue) were tested to remove TPH by adding the various concentration of hydrogen peroxide ($H_2O_2$). Moreover the biodegradability of treated samples was observed based on the ratio of $BOD_5/COD_{Cr}$ after Fenton-like oxidation. The Highest removal of TPH was at 1% of hydrogen peroxide ($H_2O_2$) when hydrogen peroxide ($H_2O_2$) was continuously injected for a period of time rather than that of spot introduction with the same amount of it. For the dewatered cake, TPH was effectively treated when the ratio of solid and water was mixed at 1 : 2. Employing cooking oil could increase solubility of TPH due to enhanced surface-active escalating TPH desorption from silty clay. Nonetheless, the biodegradability was decreased as long as the oxidation duration being extended regardless of operational conditions. It was therefore proved that Fenton-like oxidation using $H_2O_2$ and natural iron minerals was able to remove adsorbed oils in silty clay but the removal efficiency of TPH was low. And if a biological treatment process followed after Fenton-like oxidation, microorganisms would need enough time for acclimation.

Spatial and Temporal Changes in Sediments of Major Tidal Flats in the Western and Southern Korean Coasts: Grain Size, Organic Matter, Trace Metals (한반도 서·남해 주요 갯벌 퇴적물의 시·공간적 변화: 입도, 유기물, 중금속)

  • KIM, EUNYOUNG;RYU, SANG-OK;CHOI, DAE-UP;LEE, JAE-HWAN;OH, HA-NEUL;OH, SUN-KWAN;KHO, BYUNG-SEOL;KIM, YOUNG NAM;YEO, JEONG WON
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.1
    • /
    • pp.54-63
    • /
    • 2019
  • As a part of the national marine ecosystem monitoring program, the temporal and spatial variation of sedimentary environment and pollution of organic matters and trace metals from four major tidal flats, i.e., Ganghwa Is., Garolim bay, Jeung Is., Suncheon bay, was investigated for 3 yerars from 2015 to 2017. The mean grain size of the sediment was $5.0-5.3{\varnothing}$ at Ganghwa Is, $4.5-4.8{\varnothing}$ at Garolim bay, $6.1-6.5{\varnothing}$ at Jeung Is, and $8.6-8.7{\varnothing}$ at Suncheon bay. The mean grain size (Mz) tended to decrease from the north (Ganghwa Is.) to the south (Suncheon bay). The ignition loss (IL) was 15.5% in Suncheon bay in 2015, which was relatively high compared to other sites, but gradually decreased over time from 8.3% in 2016 to 7.0% in 2017. In Jeung Is. and Suncheon bay, the concentration of Zn and As exceeded the threshold effect level (TEL) at some stations, but the range of trace metals in the other sites was below the level. In Jeung Is., the Mz and concentration of trace metals except Hg was positively correlated (r= 0.40-0.88, P<0.05). On the other hand, Mz was negatively correlated with trace metals (P<0.05) in Suncheon bay. The geoaccumulation index ($I_{geo}$) to evaluate contamination status of sediments for trace metal was less than 1(not contaminated) for Cu, Zn, Pb, Cd and Hg, and 2-3 (moderately to strongly polluted) for As at several stations in Suncheon bay and Jeung Is.

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.

Soil CO2 Monitoring Around Wells Discharging Methane (메탄 유출 관정 주변의 토양 CO2 모니터링)

  • Chae, Gitak;Kim, Chan Yeong;Ju, Gahyeun;Park, Kwon Gyu;Roh, Yul;Lee, Changhyun;Yum, Byoung-Woo;Kim, Gi-Bae
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.407-419
    • /
    • 2022
  • Soil(vadose zone) gas compositions were measured for about 3 days to suggest a method for monitoring and interpreting soil gas data collected around wells from which methane(CH4) is outflowing. The vadose zone gas samples were collected within 1 m around two test wells(TB2 and TB3) at Pohang and analyzed for CO2, CH4, N2 and O2 concentrations in situ. CO2 flux was measured beside TB2. In addition, gas samples from well head in TB2 and atmospheric air samples were collected for comparison. Carbon isotopes of CO213CCO2) of samples collected on the last day of the study period were analyzed in the laboratory. The two test wells (TB2 and 3) were 12.7 m apart and only TB3 was cemented to the surface. According to the bio-geochemical process-based interpretation, the relationships between CO2 and O2, N2, and N2/O2 of vadose zone gas were plotted between the lines of CH4 oxidation and CO2 dissolution. In addition, the CH4 concentrations of gas samples from the wellhead of the uncemented well (TB2) were 5.2 times higher than the atmospheric CH4 concentration. High CO2 concentrations (average 1.148%) of vadose zone gas around TB2 seemed to be attributed to the oxidation of CH4. On the other hand, the vadose zone CO2 around the cemented well(TB3) showed a relatively low concentration(0.136%). This difference indicates that the vadose zone gas(including CO2) around the CH4 outflowing well were strongly affected by well completion(cementing). This study result can be used to establish strategies for environmental monitoring of soil around natural gas sites, and can be used to monitor leakage around injection and observation wells for CO2 geological storage. In addition, the method of this study is useful for soil monitoring in natural gas storage and oil-contaminated sites.