• 제목/요약/키워드: Contaminated ground-water

검색결과 119건 처리시간 0.025초

침출수로 오염된 불포화사질토의 전기비저항 변화에 대한 연구 (A Study on the Variation of Resistivity of the Unsaturated Sandy Soils Contaminated by Leachate)

  • 윤춘경;유찬
    • 한국농공학회지
    • /
    • 제40권2호
    • /
    • pp.112-122
    • /
    • 1998
  • Measurement of electrical resistivity in soils has been used for many years with purpose of estimating in situ porosity or density. Recently electrical resistivity has also been used as an indicator of soil contaimination. This paper presents the result of laboratory experiment to investigate the resistivity variation in contaminated sandy soils. The results can be used with the Cone Penetrometer Test (CPT) result to analyse ground condition. In the experiment, the water content and leachate concentration of soils were controlled by groundwater and leachate, and then the resistivity measurement was made with 'STING-R1' by Advanced Geosciences Inc. In the case of using groundwater, the resistivity was in the range of over 1000${\omega}{\cdot}m$, but in the case of using polluted water by leachate, the resistivity decreased significantly down to 10~ 100${\omega}{\cdot}m$ for the same moisture content. Also the resistivity varied according to the degree of saturatrion. Therefore, if soil is contaminated by leachate, the CPT with electrical resistivity sensor might be used to investigate the contamination status and plume migration. But exact component of leachate and the pollutant concentration are still hard to identify.

  • PDF

흙의 자체정화능력을 이용한 오염된 토양정화 (Application of Soil's Self-Decontamination Ability to Contaminated Ground)

  • 정진섭;정정권;김태형
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.632-638
    • /
    • 2006
  • 최근에 오염된 토양을 정화하기 위해서 다양한 방법들이 사용되고 있으나 이들 대부분은 이미 오염된 토양에 대한 정화기술로서 많은 비용이 수반되는 단점이 있다. 본 연구에서는 이들 방법과는 달리 잠재적인 토양오염지역에서 오염되기 전이나 혹은 진행 중일 때 지형학적인 특징, 지표 위나 아래의 배수시스템의 재배열 및 선행계획을 통해 토양자체의 정화능력을 이용하는 새로운 정화방법을 고찰하였다. 즉, 토양자체 정화과정이 왜, 어떻게 발전되는가에 대해 단계적으로 규명하였다. 해안지역에서 오염된 바닷물의 침투와 거주지역에서 유해 라돈가스($^{222}Rn$)의 조절 및 제거 등 두 가지 사례를 통해 흙의 자체정화 능력을 이용한 토양정화방법의 효율성을 평가하였다.

폐광 부지의 재해 및 오염대 조사관련 물리탐사자료의 고찰 (Case Studies of Geophysical Mapping of Hazard and Contaminated Zones in Abandoned Mine Lands)

  • 심민섭;주현태;김관수;김지수
    • 지질공학
    • /
    • 제24권4호
    • /
    • pp.525-534
    • /
    • 2014
  • 폐광 부지에서 발생하는 대표적인 환경 문제는 산성으로 오염된 지표수와 지하수, 적재된 폐광석 및 광미, 채굴 활동으로 야기된 지반침하 현상을 들 수 있다. 이 논문은 광해 유형에 따라 재해 및 오염영역을 효율적으로 탐지했던 지구물리탐사방법들을 고찰하는데 있다. 시험 자료로서 토양오염, 산성광산배수, 지반침하, 인공차수막 파손 및 광미/폐광석 적치장을 각각 대표하는 네 개의 폐광 부지를 선택하였다. 자료 검증을 위해 물리탐사자료는 자료의 유형에 따라 시추자료(코어 샘플, 물리검층, 토모그래피 등)와 물 자료(수소이온농도, 전기전도도, 중금속원소 등)와 비교하였다. 토양오염 탐지에 있어서 낮은 전기비저항 이상대는 특히 구리, 납, 아연의 중금속 농도가 높은 지역과 부합된다. 산성광산배수의 유동 경로는 자연전위 곡선에서 음의 전위 이상대, 전기비저항자료에서의 저비저항 이상대, 지하레이더 자료에서의 얕은 투과깊이 영역으로 탐지되었다. 채굴적은 전기비저항 단면에서의 저비저항 이상대, 탄성파토모그래피에서 낮은 속도 영역, 물리검층곡선의 복합해석으로 특징되며, 정확한 위치는 코어자료와 시추공영상자료에서 잘 확인되었다. 침출수 유동을 차단하기 위해 설치된 인공차수막의 파손 구간은 전기비저항 자료에서의 국부적인 이상대로 정확히 탐지되며 매립된 폐석더미는 고비저항 이상대와 저속도 이상대로 특징된다.

액체산소를 사용하는 발사체 산화제 및 산화제 지상공급시스템의 품질관리 (Quality control for the liquid oxygen as the oxidizer of launcher and the liquid oxygen filling system as ground facility)

  • 김지훈;유병일;강선일;오승협
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.309-312
    • /
    • 2009
  • 성공적인 발사나 시험 운용을 위해서는 여러 가지 위험 요소들을 사전에 제거하여야 한다. 오염된 추진제 사용은 발사 혹은 시험을 실패하게 하는 원인들 중 하나이다. 특히 액체산소를 산화제로 사용하는 발사체 및 공급시스템의 경우 기계적 불순물, 유지분, 수분 등의 오염원들로 청정상태를 유지하지 못할 경우 예기치 못한 화재나 폭발의 위험도가 높아지게 된다. 본 논문에서는 이러한 오염원들을 제거하고 시스템을 청결하고 안전한 상태로 유지하기 위한 방법을 제시하고 그 적용결과 및 교훈을 정리해 보았다.

  • PDF

무주지역 수질특성자료의 통계학적 분석에 의한 소유역 구분 (Watershed Classification Using Statistical Analysis of water Quality Data from Muju area)

  • 한원식;우남칠;이기철;이광식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권3호
    • /
    • pp.19-32
    • /
    • 2002
  • 본 연구는 무주군 적상산 부근에 위치하는 소유역에서 지표수의 수질과 인접한 천층지하수 수질사이의 관계 및 지질매체와 오염원의 유입에 의한 계절적인 변동을 규명하기 위하여 수행되었다. 8월과 10월 두 차례의 조사결과 이곳 지표수와 지하수 수질은 Ca-$HCO_3$유형이 주를 이루고 있었으며 인근 광산부근에서는 중금속에 의한 오염이 나타나고 있었다. 10월 조사시에 인가가 밀집한 지역에서는 질산성 질소의 의한 오염 또한 높게 나타나는 특징을 보이고 있다. 이러한 자료를 토대로 군집분석(Cluster Analysis)과 주성분 분석(Principal Component Analysis)을 실시하였으며, 군집분석결과 지표수는 5개의 그룹으로 구분되었고 지하수는 3개의 그룹으로 구분되었다. 주성분분석 결과는 군집분석 시에 나타난 결과를 효과적으로 지지하고 있으며 (1)지질매체의 수리지화학적 반응, (2)오염물질의 유입 (3) 인근광산에 의한 중금속 오염이 복합적으로 반응하여 나타난 결과로 해석된다.

지혈제 오염이 콤포머의 전단결합강도에 미치는 영향 (THE EFFECTS OF SURFACE CONTAMINATION BY HEMOSTATIC AGENTS ON THE SHEAR BOND STRENGTH OF COMPOMER)

  • 허정무;곽주석;이황;이수종;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.150-157
    • /
    • 2002
  • One of the latest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not dry but left moist before application of the bonding primer Ideally the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically, contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during cavity preparation. The aim of this study was to evaluate the effect of contamination by hemostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were removed soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive papers on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows : Group 1: Dentin surface was not etched and not contaminated by hemostatic agents. Group 2: Dentin surface was not etched but was contaminated by Astringedent$^{\circledR}$(Ultradent product Inc., Utah, U.S.A.) Group 3: Dentin surface was not etched but was contaminated by Bosmin$^{\circledR}$(Jeil Pharm, Korea.). Group 4: Dentin surface was not etched but was contaminated by Epri-dent$^{\circledR}$(Epr Industries, NJ, U.S.A.). Group 5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6: Dentin sorface was etched and contaminated by Astringedent$^{\circledR}$. Group 7 : Dentin surface was etched and contaminated by Bosmin$^{\circledR}$. Group 8: Dentin surface was etched and contaminated by Epri-dent$^{\circledR}$. Group 9: Dentin surface was contaminated by Astringedent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 10: Dentin surface was contaminated by Bosmin$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. Group 11 : Dentin surface was contaminated by Epri-dent$^{\circledR}$. The contaminated surface was rinsed by water and dried by compressed air. After surface conditioning, F2000$^{\circledR}$ was applicated on the conditoned dentin surface The teeth were thermocycled in distilled water at 5$^{\circ}C$ and 55$^{\circ}C$ for 1,000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the knife-edge shearing rod of the Universal Testing Machine(Zwick Z020, Zwick Co., Germany) running at a cross head speed or 1.0 mm/min. Group 2 showed significant decrease in shear bond strength compared with group 1 and group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

지하수의 CFCs(Chlorofluorocarbons) 조사를 위한 시료 채취 방법의 평가 (Evaluation of Ground-Water Sampling Techniques for Analysis of Chlorofluorocarbons)

  • 고동찬;이대하
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제8권2호
    • /
    • pp.1-8
    • /
    • 2003
  • Chlorofluorocarbons(CFCs) 조사를 위한 지하수 시료 채취 방법 중 cold-welded copper tube method(구리관법)과 flame-sealed borosilicate glass ampule method(유리앰퓰법)의 두 방법을 비교하고 검토하였다. 구리관법에 의해 채취된 시료의 CFCs 농도는 중복시료간에 재현성이 불량한 반면, 유리앰퓰법은 상대표준오차가 5% 이내로 좋은 재현성을 보여주었다. 이것은 구리관법을 적용할 때, 관정의 출수구와 구리관의 연결의 밀봉성이 좋지 않았기 때문인 것으로 추정된다. 또한 구리관법에 의한 CFCs 농도는 전체적으로 유리앰퓰에 의한 값보다 높았으며 이러한 특징은 CFC-11이 CFC-12보다 더 두드러졌다. 구리관법의 경우에 플라스틱 관이나 관정에 설치된 출수구에 포함된 고무 패킹 등이 시료를 CFCs로 오염시켰을 것으로 평가된다. 유리앰퓰법을 적용했을 때에는 이러한 가능성을 제거하기 위해 stainless steel과 nylon 재질만을 이용하고, 시료채취장비를 관정의 주배수관에 직접 연결하였다. 인위적인 공급원에 의한 CFCs가 없을 것으로 예상되는 시료에서 유리앰퓰법에 의해 매우 낮은 수준의 CFCs농도가 측정됨으로써 이 시료채취과정의 유효성이 검증되었다.

지하주입 물질 거동 규명을 위한 4차원 전기비저항 영상화 (Application of 4-D resistivity imaging technique to visualize the migration of injected materials in subsurface)

  • 김정호;이명종
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 특별 심포지엄 논문집
    • /
    • pp.31-42
    • /
    • 2007
  • Dc resistivity monitoring has been increasingly used in order to understand the changes of subsurface conditions in terms of conductivity. The commonly adopted interpretation approach which separately inverts time-lapse data may generate inversion artifacts due to measurement error. Eventually the contaminated error amplifies the artifacts when reconstructing the difference images to quantitatively estimate the change of ground condition. In order to alleviate the problems, we defined the subsurface structure as four dimensional (4-D) space-time model and developed 4-D inversion algorithm which can calculate the reasonable subsurface structure continuously changing in time even when the material properties change during data measurements. In this paper, we discussed two case histories of resistivity monitoring to study the ground condition change when the properties of the subsurface material were artificially altered by injecting conductive materials into the ground: (1) dye tracer experiment to study the applicability of electrical resistivity tomography to monitoring of water movement in soil profile and (2) the evaluation of cement grouting performed to reinforce the ground. Through these two case histories, we demonstrated that the 4-D resistivity imaging technique is very powerful to precisely delineate the change of ground condition. Particularly owing to the 4-D inversion algorithm, we were able to reconstruct the history of the change of subsurface material property.

  • PDF

일본 츠꾸이 선상지 지하수의 질산성 질소 오염에 대한 수문지구화학적 연구 (Hydrogeochemical Environmental Research in Nitrate Contamination in Alluvial Fan Area Groundwater in Tsukui, Central Japan)

  • Okazaki, Masanori;Ham, Young-Sik
    • 생태와환경
    • /
    • 제37권4호통권109호
    • /
    • pp.431-435
    • /
    • 2004
  • 이 연구는 일본의 카나가와현 츠꾸이에 위치하고 있는 선상지에서 지하수 수질을 조절하는 요인들을 평가하기 위해 질산성 질소에 의해 오염된 지하수를 수문지구화학적으로 조사하였다. 2003년 월별 지하수의 수위는 강우에 의해 크게 증감하였지만, 지하수 내의 질산성 질소 농도는 약간의 변화만을 보여주었다. 뿐만아니라 년중 대부분 지하수 수질 기준의 최고 오염 수준 $10mgL^{-1}$을 초과하였다. 2003년 1년간 지하수의 재충전량은 1,730mm(지하수 수위의 일 증가의 년간 총합인 20,056mm와 일별 감소량의 년간 총합인 18,326mm의 차이)로 나타났다. 그러나 지하수 수위의 일별 증가량의 년간 총합(20,056mm)은 년간 강우량보다 약 10배 이상 높았다. 더욱이 일별 감소량의 년간 총합(18,326mm)은 많은 양의 지하수가 질산성 질소 오염과 함께 방출되었음을 보여주었다. 상당히 높은 질산성 질소를 보유한 강우가 있은 후, 선상지를 통해 많은 양의 지하수 유출입이 관찰되었다. 결과적으로, 산림지대를 포함한 이 선상지에서는 '질소 과잉' 또는 '질소 포화' 라고 하는 상태를 반영하고 있다. 많은 양의 지하수 방출은 지표수에서 질산성 질소의 오염과 같은 환경문제를 야기할 수 있으며, 본 연구를 통해 수문지구화학적 자료가 수질관리에 유용하길 기대한다.

서울 시내 궁궐 수원의 수질과 유동 특성 (Characteristics of Quality and Flow of Water Resources at Palaces in Seoul Metropolitan)

  • ;이재민;우남칠;김연태;이강진
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권2호
    • /
    • pp.61-76
    • /
    • 2011
  • This study was objected to provide suggestions for best management practices to restore the cultural and historical values of the wells in Palaces as well as their water qualities. Water resources in the five Palaces in Seoul Metropolitan, including Gyeongbokgung, Changdeokgung, Changgyeonggung, Jongmyo Shrine, and Deoksugung, were surveyed for their physical flows and chemical compositions from April to July in 2010. Ground waters in most wells were found at depths within 5 m from the ground surface, showing typical water-table aquifer systems. Hydraulic gradients indicate water resources in Gyeongbokgung, Changdeokgung, and Changgyeonggung flowing toward south, and toward east in Deoksugung area. Especially, water-level fluctuation data at S-10 in Deoksugung implied the influence of groundwater discharge facility. In Jongmyo Shrine, water was not detected in wells, indicating the water level was lower than the well depth. Based on the water chemistry and stable isotope analyses, water resources and their qualities appeared to be formed by the water-rock interaction along the groundwater paths. S-10 (Deoksugung) and S-14 (Changgyeonggung) samples were contaminated with nitrate ($NO_3$) in levels of higher than Korean drinking water standard, 10 mg/L as $NO_3$-N, but once in four sampling campaigns. In the situation that water resources in Palaces still maintain natural characteristics, the materials that will be used for the restoration and improvement of the Palace water supplies should be carefully selected not to disturb the natural integrity. In addition, because the wells are located in the center of metropolitan area, a systematic monitoring should be applied to detect and to manage the potential impacts of underground construction and various pollution sources.