As Social Overhead Capital(SOC) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, it is needed to introduce a compulsory ventilation system as well as natural ventilation mechanism. The former, that is, a special compulsory ventilation facility is very useful and helpful to prevent a tunnel of being contaminated by traffic in most case. In the case of obtaining clearer and longer driving view, the ventilation systems have to be considered in order to remove floating contaminants or exhaust gas from engines. In this paper, discharge electrode design technology will be discussed.
Objectives: The objectives of this study were to investigate fungal contamination in a 31-year old university building in Seoul, Korea, and to study the inactivation of fungi using cold atmospheric pressure plasma(CAP). Methods: To investigate the fungal contamination in a university building, air samples were collected from five locations in the building, including two study rooms, a storage room, a laboratory, and a basement. The sampling was performed in a dry season(February to April) and in a wet season(July). To study the inactivation efficacy of fungi by CAP, airborne fungal concentrations were measured before and after the operation of the CAP generator. Results: Humidity was an important factor affecting fungal growth. The airborne fungal concentrations determined in the wet season(July) were significantly higher than those determined in the dry season(February to April). In the basement, the values determined in the dry and wet season were 319 and $3,403CFU/m^3$, respectively. The inactivation efficiency of fungi by CAP was 83-90% over five to nine days of operation. Conclusions: The university building was highly contaminated by airborne fungi, especially in summer. It is concluded that humidity is an important factor affecting fungal growth and CAP is a highly useful technique for inactivation of indoor airborne fungi.
일반 음식점인 한식당의 시설과 기구의 미생물 오염도를 확인하기 위해 부산지역에서 세곳의 대형한식당을 선정하여 여름기간 중 위생평가를 실시하였다. 총 175개의 Swab 샘플이 식당의 시설과 기구의 표면에서 채취되어 총균수와 대장균군수가 측정되었다. 또한 식당내부의 공기속에 존재하는 총균, 대장균군, 포도상균 그리고 곰팡이와 효모의 오염도를 측정하기 위해 36개의 공기샘플이 채취되었다. 모든 채취된 샘플은 아이스박스에 담기어 실험실로 이송되어 분석되었다. 실험결과 대부분의 Swab된 표면들이 많은 수의미생물과 대장균군에 의해 오염된 것으로 확인되었다. 미생물의 오염정도는 샘플이 채취된 장소별로 차이가 있었다. 총균수 측정결과200$cm^{2}$의 단위면적당 검출되지 않는 것에서부터 최고 2.14$\times$$10^{9}$의 수치가 관찰되었고 대장균군인 경우에는 검출되지 않은 것에서부터 최고 8.34$\times$$10^{7}$의 수치가 검출되었다. 한식당의 공기오염도 측정결과 대부분의 측정 지역에서 일반세균, 대장균군, 포도상구균 그리고 곰광이와효모가 검출되었다. 미생물에 의해 심각하게 오염된 부분은 바닥, 트렌치, 물병내부, 플라스틱 소쿠리, 고무장갑, 선반 그리고 포장되지 않은 물수건으로 확인되었다. 이러한 장소는 위 생표준작업기준의 관리점으로 지정하여 중점적으로 관리되어야만 할 것이다. 또한 식중독사고의 발생위험을 감소시키기 위해서 육안검사와 더불어 주기적인 미생물 검사가 식당의 오염도가 높은 장소에서 수행되어져야만 할 것이다.
An experimental study was conducted to investigate the effects of air-side fouling and cleaning on the performances of various condenser coils used in unitary air-conditioning systems. A total of six condenser coils with different fin geometry and row number were tested. Performance tests were performed at three different conditions: clean-as-received, after fouling, and after cleaning. In all cases, it was observed that the fouling was mostly confined to the frontal face of the heat exchanger as reported in the previous investigations. The amount of deposited dust was more dependent on fin geometry for the single-row heat exchangers than for the double-row heat exchangers. The predominant effect of fouling was to cause a more significant increase in air-side pressure drop than a degradation in heat transfer performance. For the single-row heat exchangers, the pressure drop increased by 28 to 31%, while the heat transfer performance decreased by 7 to 12% at the standard air face velocity of 1.53 m/s depending on fin shape. For the double-row heat exchangers, the pressure drop increased by 22 to 37%, and heat transfer performance decreased by only 4-5% at the same air face velocity. Once the contaminated coils were cleaned according to the given cleaning procedure the original performance of the heat exchangers could almost be recovered completely. The pressure drop could be restored within 1 to 7% and the heat transfer performance could be recovered to within 1 to 5% of the originally clean heat exchangers. Therefore, it is concluded that a periodic application of the specified cleaning technique will be effective in maintaining the thermal performance of the condenser coils.
실내 공기질 관리의 중요성이 대두되면서 쾌적한 실내 환경에 도움을 주는 공기청정 기능과 습도 조절 기능을 동시에 갖춘 제습기와 공기청정기가 각광받고 있다. 하지만 오랜 기간 동안 공기정화제품을 사용하게 될 시에는 필터가 오염되어 본연의 기능을 상실하게 되는 것으로 알려져 있지만 이에 대한 구체적인 연구나 보고는 드문 편이다. 이에 본 연구에서는 가정과 사무실 등에서 사용한 공기정화제품을 수거하여 주요 부위별 미생물 오염도 및 주요 오염 미생물들을 분석하였다. 그 결과, 4 종류의 공기정화제품에서 오염도가 높은 부위는 필터부위, 물이 직접 닿는 부위 및 공기가 외부로부터 직접적으로 들어오는 입구부위 등에서 미생물학적 오염도가 가장 높았다. 하지만 공기정화제품은 사용하는 환경과 조건에 따라서 미생물학적 오염도 및 오염 미생물의 성상은 각각 다르게 나타났다. 하지만 이들 공기정화제품들에는 공통적으로 Staphylococcus sp., Micrococcus sp. 그리고 Bacillus sp.의 세균과 Cladosporium sp. 및 Penicillium sp.의 진균이 공통적으로 오염되어 있는 우점종인 것으로 분석되었다.
공기 오염에 의해 $SO_2$가 포함된 공기가 PEMFC cathode에 유입되어 전극 성능에 미치는 영향에 대해 연구하였다. 오염된 공기 접촉 후 저하된 성능회복을 위해 청정공기 유입, 순환전압측정법(cycle voltammetry, CV), 고전압 체류법(high voltage holding)을 사용하였다. 공기에 혼합된 $SO_2$농도 범위는 20 ppb~1.3 ppm이었다. 성능 감소 및 회복 측정은 일정전류에서 전압변화를 측정하는 방법, I-V 분극곡선 측정법, 임피던스측정법을 이용하였다. 20 ppb 농도로 $SO_2$를 200시간 주입 후 전지 전압은 주입 전보다 17 mV 감소하였다. 청정공기 주입, CV, 고전압체류방법에 의해 S가 Pt로부터 탈착되어 전지성능은 일부 회복되었다.
본 연구는 기존 설치된 주민대피시설의 실태조사를 통해 주민대피시설의 계획 및 설계에 필요한 기초자료로서의 활용을 목적으로 진행되었다. 그 결과, 첫째, 주민대피시설이 고폭탄 위주의 방호만을 고려하여 설계된 것으로 판단되나, 시설물의 출구방향, 주출입구 방호능력 등을 살펴보았을 때 실제 고폭탄에 대한 방호능력은 상당히 떨어지는 것으로 판단된다. 둘째, 전체 7개 시설은 외부에서 내부로 유입되는 공기에 대한 공기여과청정기가 설치되어 있지 않으며, 외부에 설치된 흡 배기구의 높이도 지상과 근접하게 위치하고 있어 공기보다 무거운 오염공기의 내부 유입을 발생 시킬 수 있다. 셋째, 일부시설은 방폭문이 설치되어 있으나 개구부, 방폭밸브의 역방향 등의 적절하지 못한 설치와 배관 배선의 관통부 마감상태로 인해 정상적인 방폭문의 기능유지 및 기밀성 확보는 어려울 것으로 판단된다.
As the fabrication technology used in FPDs(flat-panel displays) advances, the size of these panels is increasing and the pattern size is decreasing to the um range. Accordingly, a cleaning process during the FPD fabrication process is becoming more important to prevent yield reductions. The purpose of this study is to develop a FPD cleaning system and a cleaning process using a two-phase flow. The FPD cleaning system consists of two parts, one being a cleaning part which includes a two-phase flow nozzle, and the other being a drying part which includes an air-knife and a halogen lamp. To evaluate the particle removal efficiency by means of two-phase flow cleaning, silica particles $1.5{\mu}m$ in size were contaminated onto a six-inch silicon wafer and a four-inch glass wafer. We conducted cleaning processes under various conditions, i.e., DI water and nitrogen gas at different pressures, using a two-phase-flow nozzle with a gap distance between the nozzle and the substrate. The drying efficiency was also tested using the air-knife with a change in the gap distance between the air-knife and the substrate to remove the DI water which remained on the substrate after the two-phase-flow cleaning process. We obtained high efficiency in terms of particle removal as well as good drying efficiency through the optimized conditions of the two-phase-flow cleaning and air-knife processes.
본 연구에서는 에어컨 내에서 서식하는 세균을 분리하여 동정하였고 이들 에어컨에 대한 위생 관리에 대하여 조사하였다. 20개의 에어컨 냉각기에서 8종의 세균이 분리, 동정되었는데 그것들은 가장 많이 분리 동정된 Pantoea sp.를 비롯하여 Bacillus circulans, Bacillus pumilus, Corynebacterium, Flavimonas oryzihabitans, Ochrobacterum anthropi, Micrococcus sp., non fermented bacilli (NFB)이었다. 한편 에어컨 사용자 1,322명을 대상으로 에어컨의 위생관리 상태에 대하여 조사하였는데 설문자의 1,138명(86%)이 에어컨 사용시 환기를 하는 것으로 나타났다. 에어컨 청소에 있어서 1,128명(85%)이 청소를 하는 것으로 나타났지만 에어컨의 오염원들이 되는 에어컨의 필터 청소는 864명(66%)이 하지 않는 것으로 나타났고 에어컨의 열교환기는 1089명(82%)이 하지 않는 것으로 나타났다. 이런 결과로 상기에서 언급된 세균들과 같은 에어컨 오염원이 증가하면 호흡기 질환과 같은 인간의 질병을 초래할 수 있다는 것을 알 수 있었고 따라서 에어컨 사용시 에어컨의 오염원제거와 위생관리는 에어컨내 세균으로부터 발생되는 인간의 질병을 예방할 수 있을 것이다.
유류화합물(디젤)로 오염된 불포화층 토양에 대한 현장오존복원공정의 기초연구로, 토양조건에 따른 오존의 이동과 분해, 디젤과의 반응경향을 조사하였다. 건조상태에서 유기물을 제거한 모래와 glass beads 충진컬럼에서 기상 오존의 분해를 조사한 결과 일차반응으로 가정시 반응 속도상수값(k)이 각각 $9.9{\times}10^{-3}s{^{-1}}$와 $4.3{\times}10^{-4}s{^{-1}}$로 나타나 모래의 경우 철 (Fe), 망간(Mn) 성분 등의 촉매작용으로 25배 가량 반감기가 짧은 것을 확인할 수 있었다. 디젤로 오염시킨 현장 토양과 모래를 컬럼에 충진하여 동일조건하에서 오존주입시 토양입자의 크기와 유 무기물의 함량 차에 의한 오존이동상에 지체효과 및 소모량의 차이를 관찰하였고, 50mL/min의 유속에서 공기만을 주입시 DRO(diesel range organic) 기준 초기 디젤총량($800{\pm}50mg/kg$)의 30%가 제거된데 비해 오존을 6mg/min으로 16시간 주입한 결과 각각 80% 이상이 제거되었다. 오존주입시간에 따라 컬럼의 유출 입부에 잔류하는 TPH(total petroleum hydrocarbon)와 DRO 중 aliphatic계열 8개 물질들의 농도를 비교/분석한 결과, 낮은 탄소수 물질들로의 전환과정을 거쳐 유체의 흐름에 따라 컬럼 밖으로 이동됨을 확인하였고, 토양내 수분함량은 오염 토양복원에 오존을 적용시 중요한 인자임을 확인하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.