• Title/Summary/Keyword: Contaminated air

Search Result 325, Processing Time 0.027 seconds

Reduction of Pesticide Residues in the Production of Red Pepper Powder

  • Chun, Mi-Hwa;Lee, Mi-Gyung
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Six organophosphorus, one organochlorine, and three synthetic pyrethroid pesticides were analyzed for their residues during washing and hot-air drying of red peppers conducted in the production of powder. The residue ratio in organophosphorus pesticides was 33% in chlorpyrifos, 31 % in diazinon, 50% in methidathion, 80% in EPN, 28% in fenitrothion, and 60% in profenofos. The ratio in pyrethroids was 109% in cypermethrin, 102% in deltamethrin, and 106% in fenvalerate. That in organochlorine was 56% in ${\alpha}$-endosulfan and 90% in ${\beta}$-endosulfan. The results were greatly different between organophosphorus and pyrethroid pesticides. UV irradiation along with hot-air drying brought about a remarkable reduction of the residues, up to 70% as compared with hot-air drying only. The removal effect was most remarkable in pyrethroids, which are hardly removed by hot-air drying. The color of the pepper was not changed during UV irradiation. The use of oxidizing agents such as hydrogen peroxide or chlorine dioxide during washing did not show a remarkable removal of residues. The residue ratio was not affected whether the pesticide is contaminated artificially or naturally.

Separation of VOCs from Air through Composite Membranes Prepared by Plasma Polymerization of Hexamethyldisiioxane (Hexamethyldisiioxane의 플라즈마 중합에 의하여 제조된 복합막을 통한 공기중의 휘발성 유기물질의 분리에 관한 연구)

  • 류동현;오세중;손우익;구자경
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.63-65
    • /
    • 1998
  • 1. Introduction : Atmospheric discharge of VOC-contaminated streams in chemical plants and air streams from chemical processes poses a serious environmental problem and entails large financial losses. Such emissions may be reduced by i) adsorption process, ii) absorption process and iii) incineration process. These processes only forbids the air pollutions. Throughout the recent decade, another technique-membrane process has emerged. The separation and recovery of organic vapors by membrane process may have great economic potential. Most of the published research works on the separation of organic vapors from air were performed using silicon rubber membranes. However, it is very difficult to fabricate very thin membranes with less than 1 $u m thickness. Plasma polymerization could be a good technique to generate a thin polymer film. The objective of this work is to find out the optimum condition of plasma polymerization for producing VOC separation membrane. For the objective, composite membranes are prepared through plasma polymerization of hexamethyldisiloxane onto porous substrates under different conditions. The membrane is then subjected to the permeation of permanent gases and VOCs to find the correlations between the physical properties of the penetrant and permeability and selectivity.

  • PDF

Impacts of Urban Green Spaces on Air Quality (도심지역 녹지의 국지적 대기환경영향에 관한 연구)

  • Joo, Hyun Soo;Kim, Seogcheol
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.386-393
    • /
    • 2009
  • This study was to find out the quantitative relation between urban treed area(neighborhood parks) and the atmosphere environment in real condition, focusing the gas-phase non-reacting air pollutants(SOx and NOx) decreasing function of trees in urban area. It also developed a quantitative analysis method for evaluation of the atmosphere influence in the type of treed areas. We set up the Pagoda Park in Seoul and its neighbourhood as a modelling area to analyse air quality impacts by urban neighbourhood park trees. From the modelling result of the Pagoda Park case study, it is concluded that urban neighbourhood park has an important meaning to suppress construction of emission sources which drive the urban polluted air quality worse, even though park's trees have relatively small air purifying function. Especially in the urban area severely contaminated by air pollutants, the first considered air quality management policy is conservation of green spaces in neighborhood park.

Risk Assessment of Volatile Organic Compounds for Vapor Intrusion Pathway Using Various Estimation Methodology of Indoor Air Concentration (다양한 실내 침투 휘발물질 농도 예측 방법을 이용한 토양오염물질의 실내흡입 위해성평가)

  • Jung, Jae-Woong;Nam, Taekwoo;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.51-65
    • /
    • 2015
  • Indoor inhalation of vapors intruded into buildings is an important exposure pathway in volatile organic compoundscontaminated sites. Site-specifically measured indoor air concentration is preferentially used for risk assessment. However, when indoor air concentration of VOC is not measured, the indoor air concentration needs to be estimated from soil concentration or measured soil gas concentration of the VOC. Some risk assessment guidance (e.g., Korea Ministry of Environment (KMOE) and American Society for Testing and Materials (ASTM) International guidance) estimate the indoor air concentration from soil concentration while other guidances (e.g., United States Environmental Protection Agency (USEPA) and Dutch National Institute for Public Health (RIVM)) estimate it from measured soil gas concentration. This study derived indoor inhalation risks of intruded benzene in two benzene-contaminated residential areas with four different risk assessment guidances (i.e., KMOE, USEPA, ASTM, and Dutch RIVM) and compared the derived risks. The risk assessment results revealed that indoor air estimation approach from soil concentration could either underestimate (when the contaminant is not detected in soil) or overestimate (when the contaminant is detected in soil even at negligible concentration) the indoor air inhalation risk. Hence, this paper recommends to estimate indoor air concentration from soil gas concentration, rather than soil concentration. Discussions about the various indoor air concentration estimation approaches are provided.

A study of asbestos risk at some naturally occurring asbestos areas, Korea (우리나라 일부 자연발생석면 발생가능지역의 석면 위해도에 관한 연구)

  • Jung, Joon Sig;Shim, In Keun;Jung, Hyen Sung;Lee, Kyu Mok;Kim, Seong Mi;Kwon, Myung Hee;Chung, Hyen Mi
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.330-336
    • /
    • 2018
  • The objective of this study was to determine whether crops and fruits absorb the naturally occurring asbestos (NOA). The concentration of asbestos in various crops and fruits grown in NOA areas was analyzed and background levels of asbestos in ambient air and soil samples were assessed. Actinolite/Tremolite asbestos were detected in all soil samples. Among 21 ambient air samples, 2 samples were recorded to contain 0.0005 f/cc (fiber per cubic centimeter) but no asbestos was detected in the other samples using transmission electron microscopy (TEM). However, no evidence suggesting that the crops and fruits could be contaminated by NOA was found in this study. The excess lifetime cancer risks (ELCRs) of ABS scenarios (agricultural activities) used in this study were calculated by using the Arithmetic (AM) and Geometric mean (GM) of ELCRs. The AM and GM of ELCRs estimated from digging soil and weeding activities did not exceed $1{\times}10^{-4}$, which was defined as the general acceptable risk range for exposure. The results of this study would be informative to NOA managers and related policy makers to make plans to prevent unexpected exposure to asbestos to residents living in an NOA area.

Bioventing 공법에서 TPH 제거에 대한 특징

  • Kim, Yeong-Am;Lee, Guk-Ui;Lee, Yong-Hui;Lee, Dong-Hwan;Kim, Dae-Hwan
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.160-165
    • /
    • 2005
  • Bioventing efficiency was compared in a continuous and an intermittent(6hr injection and 6hr rest) air injection mode. Two lab-scale columns which packed with 5kg of soil artificially contaminated by diesel oil were operated. The columns were maintained at the $25^{\circ}C{\pm}2.5$ in order to minimize the effect of exterior temperature variation. The flow rate of air injection mode were maintained constantly at the flow rate of 10ml/min. The moisture of the columns was stably maintained at $60{\sim}80%$ of field capacity. The nutrient compounds were added to make C : N : P ratio as 100 : 10 : 1. The continuous and intermittent injection modes showed 67.56% and 69.63%reduction of initial TPH concentration during 90 days, respectively. The loss of diesel oil by volatilization in the continuous and intermittent injection modes were about 5% and 1%, respectively.

  • PDF

Hygienic Aspects of Campylobacter Enteritis (Campylobacter장염에 의한 식품위생학적인 고찰)

  • 이용욱;홍종해
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.57-66
    • /
    • 1986
  • Campylobacter jejuni has been recognized as one of the causes of human gastroenteritis. The feces of a variety of reservoir animals contain c. jejuni as commensals in the intestinal tracts, and are fundamental source of contamination. The intestinal organisms contaminate carcasses, equipment tools hands of the processing line workers and air of the processing facility. Once the contamination happens in the slaughterhouses or the meat processing facilities, it is very difficult to keep the carcasses free from the infection of c. jejuni. Various disinfectants are effective in minimizing the number of Campylobacter infections in the processing facilities by washing contaminated carcasses, tools, and hands. Direct contact with infected animals has been incriminated in transmission of infection caused by C. jejuni. Freezing, cooling with dry air and gamma irradiation are an effective way for preserving the meat and eliminating the transmission, but broad and enforced studies are needed for the practical use.

  • PDF

Application of Membranes for Organic Liquid or Vapor Separation and Design of Plasma-Graft Filling-Polymerized Membranes

  • Yamaguchi, Takeo;Nakao, Shin-ichi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.34-39
    • /
    • 1996
  • There is much recent interests in applying membrane separation technologies, especially for organic liquid and vapor separation or removing dissolved organics from water. Pervaporation separation can separate azeotropic mixtures and mixtures close to boiling point, and it has a potential for energy saving process instead of distillation. Removal of chlorinated oraganics from water is other measure application for pervaporation separation. Contaminated pollutant must be removed from water, and a pervaporation can effectively remove the pollutant. Air pollution by organic vapor recently became serious enviromncntal problem, and removing organic vapor from air is important application of the membrane technology.

  • PDF

Risk Perception Associated with Noise Exposure on Pilots & Ground-crews in the Korean Air Force (공군 작업자들의 소음 폭로와 관련된 위험인지)

  • 강윤성;박상규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.610-615
    • /
    • 2002
  • This study is to evaluate the risk perception of noise of the ground-crews in the Korean airbases who exposed to noise of jet plane. 1148 ground-crews and 231 pilots of 2 airbases participated in this study. The questionnaires of risk perception with visual analogue scale were completed by the participants. For comparison, the perception of other risks such as beef contaminated with dioxin, AIDS, lung cancer, otitis media, shigellosis, driving, drinking, and smoking were also included in the questionnaire of risk perception. The results of this study suggested the necessity of risk communication about noise and activation of effective hearing conservation program in the Korean air-force.

  • PDF

The Development of Ozone Generation System with High Capacity for Advanced Water Treatment Process (고도정수처리용 대용량 오존발생시스템 개발)

  • Lee, Hyeong-Ho;Kim, Young-Bae;Seo, Kil-Soo;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2001-2003
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. Ozone generation system is composed of ozone generation device, air or oxygen supply device and high voltage apply device. In this paper, commercial frequency was applied to the wire typed conductor. The ozone concentration was measured with air or oxygen as a supplied gas, which can be used as basic data for the development of ozonizer system.

  • PDF