• Title/Summary/Keyword: Contaminant level

Search Result 134, Processing Time 0.026 seconds

Groundwater Investigation of the Cheonggyecheon Watershed Area

  • Choi, Doo-Hyung;Yang, Jea-Ha;Jun, Sung-Chun;Lee, Kang-Keun;Kim, Yoon-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.323-327
    • /
    • 2004
  • The groundwater system of the Cheonggyecheon watershed is very complicated because it is influenced by many factors such as pumping out, groundwater leakages into subway stations, civil use of groundwater, and leaking water from water supply and sewage lines. So the characterization and evaluation of tile groundwater flow and contaminant transport in the Cheonggyecheon water system is quite a difficult task. The purpose of this study is to analyze of the influence to the 'groundwater' below the Cheonggyecheon watershed by the 'surface water' on the Cheonggyecheon stream after the restoration. We have so far collected groundwater quality data, hydrogeologic aquifer parameters, and tile amount of leakages into subway stations and its influence on the groundwater system of the Cheonggyecheon. Results show that groundwater level was influenced by the direction and depth of a 녀bway station. This study will continue to monitor groundwater quality, a water level fluctuation relation between rainfall and groundwater recharge for further investigation of the groundwater flow system in Cheonggyecheon.

  • PDF

Groundwater system Investigation of the Cheonggyecheon watershed Area

  • Choi, Doo-Hyung;Yang, Jae-Ha;Jun, Seong-Chun;Lee, Kang-Keun;Kim, Yoon-Young
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.326-329
    • /
    • 2004
  • The groundwater system of the Cheonggyecheon watershed is very complicated because it is influenced by many factors such as pumping out, groundwater leakages into subway stations, civil use of groundwater, and leaking water from water supply and sewage lines. So the characterization and evaluation of the groundwater flow and contaminant transport in the Cheonggyecheon water system is quite a difficult task. The purpose of this study is to analyze the influence on the‘groundwater’ below the Cheonggyecheon watershed by the‘maintenance water’on the Cheonggyecheon stream after the restoration. We have so far collected groundwater quality data, hydrogeologic aquifer parameters, and the amount of leakages into subway stations and its influence on the groundwater system. Results show that groundwater level was influenced by the direction and depth of subway tunnel. This study will continue to monitor groundwater quality, a water level fluctuation relation between rainfall and groundwater recharge for further investigation of the groundwater flow system in the Cheonggyecheon watershed.

  • PDF

Case for Detection and Prevention of Inflow Section for Contaminant through Annular Space in Borehole, Jeju Island (제주도 관정 공벽 내 오염물질 유입 구간 탐지 및 차단 사례)

  • Song, Sung-Ho;Hwangbo, Dongjun;Kim, Jin-Sung;Yang, Won-Seok
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.3
    • /
    • pp.1-10
    • /
    • 2022
  • Most wells developed in Jeju island before the enactment of the Groundwater Management Ordinance in 2002 are vulnerable to aquifer contamination due to inflow of upper groundwater having the high concentration of nitrate nitrogen, likely due to incomplete grouting in upper section of the wells. Although these wells require entire reinstallation, it is often necessary to rehabilitate the existing wells due to various constraints. Therefore, to identified the inflow section of contaminants, the thermal level sensor (TLS) technique was firstly applied for three wells, which enables to monitor temperature variations in every 50 cm depth. Then, the grouting material was injected to the upper section to prevent the inflow of upper contaminated groundwater into the entire aquifer. By applying TLS technique, it was found that the temperature deviations in the upper groundwater inflow section decreased sharply. Moreover, both the change in the concentration of nitrate nitrogen in the rainy/dry seasons and the average concentrations were found to decrease rapidly after grouting material injection. Consequently, the application of TLS proposed in the study turned out to be appropriate to prevent aquifer contamination.

A SE Approach to Designing and Developing of Motion Control for Radioactive Waste Decontamination

  • Ngbede, Utah Michael;Olaide, Oluwasegun Adebena;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.1
    • /
    • pp.11-20
    • /
    • 2021
  • Decontamination of systems, structures and components (SSC) during the decommissioning of a Nuclear Power Plant (NPP) can be for a variety of reasons. The main reasons for decontamination are: to reduce the contamination of SSC to a reasonably low level, to reduce the potential for the spread of contaminants into the environment and to reduce the cost of disposal due to the reduced level of contamination in a particular SSC. The decontamination technique can be aggressive or non-aggressive depending on the intent after the decontamination process. Aggressive decontamination technique is used when the intent is not to reuse the SSC while a non-aggressive decontamination technique is used with the intent of SSC reuse. For different SSCs there are different decontamination techniques that can be used, each having its own advantages and drawbacks. Metal components such as pipes in the nuclear power plant account for a large amount of nuclear wastes generated. Some of these wastes can be reused if the contaminant level is reduced to an acceptable level. Laser ablation is a non-aggressive decontamination technique that can be used to reduce the contamination in pipes to an acceptable level with no secondary waste generated during the process. The operation and control of a laser ablation device must be precise to achieve a high decontamination factor. This precision can be achieved by a well-designed motion control system. For this purpose, a motion control system was developed consisting of two parts: the first part being the precise control of the laser ablation device inside the pipe and the second part is the control of the laser ablation device outside the pipe. This paper describes the Systems Engineering approach for the development process of a motion control system for the Laser decontamination system.

Environmental Characteristics of Natural Radionuclides in Groundwaters in Volcanic Rock Areas: Korea (국내 화산암 지역 지하수 중 자연방사성 물질에 대한 환경 특성)

  • Jeong, Do Hwan;Kim, Moon Su;Ju, Byoung Kyu;Hong, Jung Ki;Kim, Dong Su;Kim, Hyun Koo;Kim, Hye Jin;Park, Sun Hwa;Han, Jin Seok;Kim, Tae Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.36-45
    • /
    • 2013
  • We analyzed natural radionuclides in 80 wells in volcanic rock areas and investigated environmental characteristics. Uranium and radon concentrations ranged from ND to $9.70{\mu}g/L$ (median value: 0.21) ${\mu}g/L$, 38~29,222 pCi/L (median value: 579), respectively. In case of gross-${\alpha}$, 26 samples exceeded MDA (minimum detectable activity, < 0.9 pCi/L) value and the activity values ranged from 1.05 to 8.06 pCi/L. The radionuclides concentrations did not exceed USEPA MCL (maximum contaminant level) value of Uranium ($30{\mu}g/L$) and gross-${\alpha}$ (15 pCi/L). But Rn concentrations in 4 samples exceeded USEPA AMCL (Alternative maximum contaminant level, 4,000 pci/L) and one of them showed a significantly higher value (29,222 pCi/L) than the others. The levels of uranium concentrations in volcanic rock aquifer regions were detected in order of andesite, miscellaneous volcanic rocks, rhyolite, basalt aquifer regions. Radon, however, was detected in order of miscellaneous volcanic rocks, rhyolite, andesite, basalt aquifer regions. The correlation coefficient between uranium and radon was r = 0.45, but we found that correlations of radionuclides with in-situ data or major ions were weak or no significant. The correlation coefficient between the depth of wells and uranium concentrations was a slightly higher than that of depth of wells and radons. Radionuclide concentrations in volcanic rock aquifers showed lower levels than those of other rock aquifers such as granite, metamorphic rock aquifers, etc. This result may imply difference of host rock's bearing-radioactive-mineral contents among rock types of aquifers.

Potential Human Health and Fish Risks Associated with Hypothetical Contaminated Sediments Using a Risk Assessment Model ($TrophicTrace^{(R)}$) (위험평가모형($TrophicTrace^{(R)}$)을 이용한 가상 해양오염퇴적물의 쥐노래미와 인체 영향 예비평가)

  • Yang, Dong-Beom;Hong, Gi-Hoon;Kim, Kyung-Ryon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.60-70
    • /
    • 2011
  • The sediment removal index derived from the chemical contaminants, $CI_{HC}$, is currently in use to identify and define the spatial extent of the contaminated sediments in the sea. In order to analyze the sensitivity of the ecological and human risk associated with contaminated sediment, we evaluated five hypothetical contaminated sediments, whose $CI_{HC}$ values are identical but consisted of different contaminant contents, using $TrophicTrace^{(R)}$ model dedicated to evaluate sediment risk, against the resident greenling (Hexagrammos otakii) and humans by calculating No-Observed-Adverse-Effect-Level based Toxicity Quotient (NOAEL TQ) and Lowest-Observed-Adverse-Effect-Level based Toxicity Quotient (LOAEL TQ), and cancer risks and hazard indices (HI), respectively, based on the site conceptual model and exposure assumptions of fish ingestion to human receptor populations. NOAEL and LOAEL TQ values varied as much as a factor of 2 among 5 hypothetical sediments. Chemical element specific contribution to the carcinogenic risk and HI varied also greatly in these sediments. The reason for this significant dissimilarity in ecological and human risk stems from the different risk of each contaminant to the resident fish and human receptor. When the conceptual food web model is constructed for the target biological species for a given site, the ecological and human risk analysis considering trophic transfer of contaminants will add a ecosystem based tool for the management of contaminated sediments.

Analysis of 226Ra in the Groundwater Using the Gamma-ray Spectroscopy (감마선 분광법을 이용한 지하수 중의 226Ra 분석)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The measurement of radium ($^{226}Ra$) in the groundwater was established using ${\gamma}$-ray spectroscopy without sample preparation. The background interference by air borne radon daughter nuclides was reduced by $N_2$ gas flow into the counting chamber. Leakage of radon gas produced in the radioactive equilibrium with radium and its daughter nuclides was prevented by use of the air-tighted aluminium container. We investigated the effect of air layer in the counting container. Radioactivity variation due to emanation of radon into the air layer was within the counting error range 5%. When the nitrogen gas was flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of airborne radon was decreased and detection limit was decreased to 0.02 Bq/L. The detection limit of detector was lower than 0.74 Bq/L, the $^{226}Ra$ Maximum Contaminant Level (MCL) in the groundwater proposed by US Environmental Protection Agency (EPA). It was confirmed that $^{226}Ra$ radioactivity in the groundwater could be determined by the ${\gamma}$-ray spectroscopy.

Evaluation of Soil Health Affected by Soil Remediation Technologies and Its Processes (토양정화 공법 및 단위공정에 따른 토양건강성 평가)

  • Kim, Mintchul;Chun, Mihee;Kim, Jungsun;Park, Minjeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.6
    • /
    • pp.36-46
    • /
    • 2021
  • The Soil Health Index (SHI) developed by Park et al. (2021) is used to evaluate soil health on remediated soils collected from several remediation project sites and monitored the changes of SHI during the remediation process of land farming, soil washing, and thermal desorption. In the case of land farming, the soils remediated below a legal standard didn't show any significant changes in indices of SHI except the downgrade of available phosphate from medium to a low level. The SHI scores were ranged from 52 to 56 in the contaminated soil and 54 to 57 in the remediated soil. With soil washing, bulk density changed from high to a low level, and available phosphate was lowered from medium to low level. As the SHI scores were evaluated as 58 to 63 for contaminated soil and 38 to 42 for remediated soils. For thermal desorption, soil respiration rate was reduced from high to low level and SHI was scored as 50 to 51 for contaminated soils and 43 to 47 for remediated soils. Even though any abrupt changes of the SHI in remediated soils were not identified in the soils used in this study, it is expected that soil in different conditions such as types and concentrations of contaminant and soil characteristics would result in distinguished changes of the SHI. There is a room for more studies collect diverse information on SHI across the country.

Complexity of Groundwater Flow System in a Site Reflected in the Fluctuations of Groundwater Level and Temperature (지하수위와 수온 변동에 나타난 부지 규모 지하수 흐름장의 복잡성)

  • Jonghoon Park;Dongyeop Lee;Nam C. Woo
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.563-570
    • /
    • 2022
  • This study was objected to show the complexity of groundwater flow system in a site-scale area as a design parameter of the groundwater monitoring network for early detection of pollutant leakage from a potential source of groundwater contamination (e.g., storage tank). Around the tanks, three monitoring wells were installed at about 22~25 m deep and groundwater level and temperature had been monitored for 22 months by 2-minute interval, and then compared with precipitation and temperature data from nearby weather station. Annual variation of groundwater level and its response to precipitation event, variation of groundwater temperature and delayed response to that of atmospheric temperature indicate the complexity of groundwater flow and flow paths even in the relatively small area. Thus, groundwater monitoring network for early detection of contaminant leakage should be designed with full consideration of the complexity of groundwater flow system, identified from the detailed hydrogeological investigation of the site.

Fumonisin $B_1$-induced Alteration of Sphingolipid Metabolism in $LLC-PK_1$ Cells ($LLC-PK_1$ 세포에서의 퓨모너신 $B_1$에 의해 유도된 스핑고리피드 대사)

  • Yoo, Hwan-Soo;Yun, Yeo-Pyo
    • YAKHAK HOEJI
    • /
    • v.41 no.6
    • /
    • pp.789-796
    • /
    • 1997
  • The purpose of this study was to determine the effect of sulfinpyrazone on fumonisin $B_1$-induced elevation of free sphingoid bases in LLC-$PK_1$ cells. Fumonis ins are a family of mycotoxins produced by the fungi Fusarium moniliforme which is common contaminant in corn. Fumonisins are also potent inhibiors of sphingosine and sphinganine N-acyltransferases (ceramide synthases), key enzymes in sphingolipid metabolism resulting in the elevation of free sphinganine. The cytosolic concentration of fumonisin B1 was known to be closely proportional to the elevation of free sphinganine in LLC-PK1 cells [Yoo, H.-S., Norred, W.P., Wang, E., Merrill, A.H., Jr., and Riley, R.T. (1992) Toxicol. Appl.Pharmacol. 114. 9-15]. Sulfinpyrazone, an anion transport inhibitor, reduced the elevated level of free sphinganine resulting from fumonisin B1 inhibition of de novo sphingolipid biosynthesis. Fumonisin B1 at a concentration of 20${\mu}$M showed approximately 120pmol/$10^6$ cells relative to 3-10pmol/$10^6$ cells in control cultures, and sulfinpyrazone at a concentration of 200${\mu}$M partially reversed the increased level of free sphinganine induced by fumonisin $B_1$ down to normal level after exposure to fumonisin $B_1$ for 8 to 24hr. However, the reduced effect of sulfinpyrazone on the fumonisin $B_1$-induced elevation of intracellular sphinganine was not shown after 24hr. Fumonisin $B_1$ exposure to LLC-PK1 cells for 36 and 48hr showed approximately 74 and 80pmol per $10^6$ cells relative to 82 and 76pmol,respectively, in fumonisin $B_1$ plus sulfinpyrazone-treated cultures. Sulfinpyrazone-induced less elevation of free sphinganine in confluent cells after exposure to fumonisin $B_1$ suggested that either sulfinpyrazone may block the availability of fumonisin $B_1$ to cells or act on the fumonisin $B_1$ interaction with ceramide synthase.

  • PDF