• Title/Summary/Keyword: Contaminant level

Search Result 134, Processing Time 0.026 seconds

Comparison of Heavy Metal Pollutant Exposure and Risk Assessments in an Abandoned Mine Site (폐광산 주변 토양 중금속 오염노출농도 우려기준과 위해성 비교 연구)

  • Choi, Jinwon;Yoo, Keunje;Koo, Myungseo;Park, Joon-Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4B
    • /
    • pp.261-266
    • /
    • 2012
  • In this study, soil environmental impact assessment using risk-based approach was compared with that using concentration-based approach. For this, heavy metal contaminant exposure was characterized in an abandoned mine area. According to the estimated carcinogenic and non-carcinogenic risks, soil ingestion was identified as the most dominant exposure pathway. When contaminant concentrations exceeded the Korean Soil Contamination Warning Standards, their corresponding risk values also exceeded the Total Soil Risk Standard. Even the cases of satisfying the Korean Soil Contamination Warning Standards mostly showed higher risk levels than the Total Soil Risk Standard, re-confirming a more sensitivity of the risk-based assessment than concentration-based assessment. However, the in-depth analysis of the estimated non-carcinogenic risk values revealed a few cases for soil contact pathway showing contaminant concentrations higher than the Korean Soil Contamination Warning Standards although their non-carcinogenic risk values satisfied the level of Hazard Index Standard. The findings from this study support a necessity of shifting policy paradigm from concentration-based approach into risk-based approach for reliable risk assessment in abandoned mine areas, and also suggest a necessity of further fundamental studies regarding risk factors and standards.

Changes in Steroid Hormones Levels of Olive Flounder, Paralichthys olivaceus Exposed to Phenanthrene

  • Jee, Jung-Hoon;Min, Eun-Young;Kim, Dae-Jung;Kang, Ju-Chan
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.4
    • /
    • pp.352-357
    • /
    • 2003
  • Phenanthrene, one of Polycyclic aromatic hydrocarbons with three aromatic rings, is a ubiquitous contaminant in the environment. Phenanthrene has been identified in ambient air, drinking water and sediment. We examined the effect of phenanthrene on steroid hormones level of olive flounder, Paralichthys olivaceus. Plasma testosterone level was increased significantly in fish exposed to phenanthrene($\geq1.0 \mu M$) at 4th week. However, there was no significant changes of estradiol-17$\beta$ concentration in fish exposed to phenanthrene. The physiological variation in phenanthrene exposed fish was a dramatic increase in plasma cortisol level. It is concluded that chronic exposure of phenanthrene can induce increase of plasma testosterone levels and elevate the plasma cortisol level in flounder, Paralichthys olivaceus.

Removal of Diazinon and Heavy Metals in Water by Benthic Macroinvertebrate (저서성 대형무척추동물을 이용한 수중의 다이아지논 및 중금속 제거)

  • Lee, Hwa-Sung;Ryoo, Keon-Sang
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.57-67
    • /
    • 2012
  • The midge samples were undertaken at three streams, representing different surrounding environments, to investigate the contaminant exposure of midge. The content of heavy metals in midge collected in Singil stream were generally higher as a result of input to the industrial effluents with respect to other streams. Adsorption experiments were done to evaluate the possibility of removing contaminants from water with midge. Diazinon and heavy metals were contaminant target compounds in this study. The removal rate of diazinon in water by midge was 60-75%. In the case of Cu, the removal rate was reached around 90% at the lower initial concentration of 1.87 and 0.81 ppm rather than 4.25 ppm. The reduction of concentration of Cr and Cd according to the lapse of time was similar to the Cu, but their removal rates were shown 50% and 60-74%, respectively. The removal rate of Zn by midge represented relatively high level within the experimental condition. No change in concentration of Cr and As with time were occurred at all experimental conditions. It accounts for the fact that the reduction of Cr and As could not be achieved through the adsorption process, using midge.

Zoning Method to Predict Contaminant Sources in Turbulent-Type Cleanroom (난류형 클린룸에서 영역분할법을 이용한 오염원 추정에 관한 연구)

  • Kim, D.K.;Sung, H.G.;Han, S.M.;Hwang, Y.K.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.253-260
    • /
    • 2015
  • Particle contamination in a cleanroom is very complex with a complicated process and several pieces of spreading equipment. Detailed information on the locations of the contamination sources and the path of the contamination is needed for economical and efficient control of the contaminant particles in such a cleanroom. An allocation method was developed to quantitatively predict the contamination generated from the pollution sources. In this paper, we propose a zoning method to accelerate the computation time for estimating the contributions. Our results showed that we can quantitatively estimate the amount of contamination generated from pollution sources.

The study on the Performance of air sterilization of multistoried apartment by the multizone modeling (멀티죤 시뮬레이션에 의한 공동주택의 미생물 오염원제거 성능평가에 관한 연구)

  • Choi, Sang-Gon;Park, Kyung-Su;Yoon, Young-Soo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.319-324
    • /
    • 2006
  • The purpose of this study Is to evaluate the efficacy of multizone simulation that enables to grasp of details about microbial contaminant problem in an multistoried apartment. We used actual indoor test data to figure up microbial contaminant level as initial value for the multizone simulation and estimated the various effects of indoor occupant infected with germs and the performance of air sterilization by using multizone simulation in substitute for infeasible experimental approach. The results show that natural ventilation make ourselves generally useful for removing indoor microbial contaminants. The results also show that the performance of air sterilization reach the maximum in the case of using mechanical ventilation and UVGI air sterilizer. The conclusion is that this multizone simulation is useful tool for actual design method for Immune building systems.

  • PDF

Monitoring of Cleanliness Level in Hydraulic Systems: Obtaining Reliable On-Line data

  • Hong, Jeong-Hee;Day, Mike
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.28-38
    • /
    • 2012
  • Monitoring of system cleanliness levels and counting of particulate contaminant are fundamental to achieving hydraulic system reliability as any departure from the specified cleanliness level is often a precursor to future failures. On-line monitoring of cleanliness levels has the advantage of giving data both very quickly and accurately as environmental influences are eliminated. In this way, corrective actions can be promptly implemented. Most on-line instruments are sensitive to system conditions to a greater or lesser extent, but Automatic Particle Counters (APCs) working on light extinction principles are especially sensitive to the presence of optical interfaces caused by such conditions as fluid mixtures, emulsions, free water and air bubbles. These conditions give erroneous data and can result in drawing incorrect conclusions, wasting maintenance time and ultimately, reduced user confidence in cleanliness monitoring. This paper describes such conditions and shows how the correct selection of the analysis technique can result in reliable cleanliness level data.

Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters (배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

Cation Exchange Capacity and Zeta Potential Characteristics of Kaolinite Contaminated with Lead (납으로 오염된 카올리나이트의 양이온교환능력 및 계면동전위 특성)

  • 장경수;강병희
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.38-43
    • /
    • 2002
  • A series of tests were performed to investigate the effects of pH and contamination level on cation exchange capacity and zeta potential in kaolinite loaded with lead. Test results show that cation exchange capacity of kaolinite is found to be in the range from 4 to 20meq/100g and it increased with increasing pH up to the converged number about 20meq/100g over pH 8. And then CEC has a tendency to reduce and converge to zero with increasing the concentration of Pb in the kaolinite surface. Moreover, zeta potential of kaolinite contaminated with lead is found to be in the range from -10 to 5mV, and zero point of charge is measured at about pH 3.5. Zeta potential of kaolinite contaminated with lead decreases with increasing pH values and decreasing Pb concentration of kaolinite.

  • PDF

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

A Study on the Water Resource and Environmental Pollution Level of Education Facilities in Green Building Certification Criteria (학교시설 친환경건축인증 사례를 통한 수자원 및 환경오염 평가항목 연구)

  • Kwag, Moon-Geun;Choi, Chang-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.678-687
    • /
    • 2009
  • The purpose of this study is to develop the assessment category, items, a detail standard for environmentally friendly evaluation on the school. and to analyze the plan to improve the level of certification criteria on the School's water resource and environmental pollution. The results of this study brings on promoted environmentally friendly appreciation, resource con servation, reduction of contaminant, accordance in and around building, etc. For this purpose, analysis of domestic and foreign environmental friendly architectural citation screening system-BREEAM (1991), LEED 2.0(2001) etc.-was preceded, and through interview, survey and forum with professional group, developed evaluation item was verified and reappraised. Developed evaluation item were composed of 40 schools about water resource and environmental pollution.