• Title/Summary/Keyword: Contaminant Accumulation

Search Result 22, Processing Time 0.026 seconds

PREDICTION OF AERODYNAMIC PERFORMANCE LOSS OF A WIND TURBINE BLADE SECTION DUE TO CONTAMINANT ACCUMULATION (외부 오염물 증착에 의한 풍력 터빈 날개 단면의 공력 성능 저하 예측)

  • Yang, T.H.;Choi, J.H.;Yu, D.O.;Kwon, O.J.
    • Journal of computational fluids engineering
    • /
    • v.18 no.1
    • /
    • pp.91-97
    • /
    • 2013
  • In the present study, the effects of contaminant accumulation and surface roughness on the aerodynamic performance of wind turbine blade sections were numerically investigated by using a flow solver based on unstructured meshes. The turbulent flow over the rough surface was modeled by a modified ${\kappa}-{\omega}$ SST turbulence model. The calculations were made for the NREL S809 airfoil with varying contaminant sizes and positions at several angles of attack. It was found that as the contaminant size increases, the degradation of the airfoil performance becomes more significant, and this trend is further amplified near the stall condition. When the contaminant is located at the upper surface near the leading edge, the loss in the aerodynamic performance of the blade section becomes more critical. It was also found that the surface roughness leads to a significant reduction of lift, in addition to increased drag.

A Study on Measurement of ESDD and Contamination Performance of Polymeric Outdoor Insulators (옥외용 절연체 표면에서의 ESDD 측정과 내오손특성에 관한 연구)

  • 연복희;유형철;이현진;송정용;이태호;허창수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.427-430
    • /
    • 2002
  • This paper presents on contamination performance of polymeric outdoor insulator with different contaminant accumulation. The ESDD (equivalent salt deposit density), tracking resistance and clean-fog test were performed to investigate the characteristics of contamination performance on polymeric outdoor insulator. Furthermore, we evaluated together with the porcelain samples for its comparison. It is found that ESDD of polymeric and porcelain insulator depends on the installation position. This surface accumulation of contaminant lead to the loss of surface hydrophobicity, expecially upper shed part of polymeric insulator. In addition, the effect of an artificial contaminant on the tracking resistance by inclined-plane method and leakage suppression ability under clean fog was surveyed. The time of tracking failure did not appear to change significantly with a much contaminant accumulation, while leakage current under clean-fog increased.

  • PDF

A Study on Kaolin Contaminant Accumulation Contents and Leakage Current Variation (카올린 오손물 누적량 및 누설전류 변화에 관한 연구)

  • Park, Jae-Jun;Song, Il-Keun;Lee, Jae-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.145-146
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW.

  • PDF

A Study on Mechanism about Contaminant Accumulation of Insulator Surface (애자표면의 오손물 누적에 관한 메커니즘 연구)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.8 no.2
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

Biobarrier를 이용한 유기오염물질의 생물학적분해모의를 위한 수치모델개발

  • 왕수균
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.137-140
    • /
    • 2003
  • This study presents a mathematical model for simulating the fate and transport of a reactive organic contaminant degraded through cometabolism in dual-porosity soils during the in situ bioaugmentations. To investigate the effect of dual-porosity on transport and biodegradation of organic hydrocarbons, a bimodal approach was incorporated into the model. Modified Monod kinetics and a microcolony concept [Molz et at., 1986〕 were employed to represent the effects of biodegrading microbes on the transport and biodegradation of an organic contaminant. The effect of permeability reduction due to biomass accumulation on the flow field were examined in the simulation of a hypothetical field-scale in situ bioaugmentation. Simulation results indicate that the presence of the immobile region can decrease the bioavailablity of biodegradable contaminants and that the placement of microbes and nutrients injection wells should be considered for an effective in situ bioaugmentation scheme.

  • PDF

Accumulation and Depuration of Fluoranthene, a Polycyclic Aromatic Hydrocarbon, in Rockfish Sebastes schlegeli (조피볼락 (Sebastes schiegeii)에서 다환성방향족탄화수소 fluoranthene의 축적과 배설)

  • Park Kwan Ha
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.3 s.50
    • /
    • pp.223-228
    • /
    • 2005
  • Rockfish Sebastes schlegeli was exposed to fluoranthene, a ubiquitous polycyclic aromatic hydrocarbon, at 1 and 10 $\mu$g/L for 4 weeks followed by depuration period of 8 weeks. Although the fluoranthene in the p]asma reached only 1.8$\~$1.9 times seawater concentration, it was 6.5 $\~$ 15.7 times higher in the liver, spleen and bile indicating efficient accumulation in the lipid -containing body tissues. When the exposed fish were then maintained in clean water, rapid fluoranthene decline occurred in the initial 2 weeks followed by a rather slow phase. This result suggests that fluoranthene accumulates efficiently provided the existence in the culture medium, but the contaminant disappears rapidly once the chemical source is removed. The fluoranthne residue in fish tissues my be a good indifator for relent PAHs exposure.

A Simulation for Kaolin Contaminants Accumulation and Varying Characteristics of Leakage Currents (Kaolin 오손물 누적량 모의실험 및 누설전류변화 특성)

  • ark, Jae-.Jun;Song, Il-keun;Lee, Jae-bong;Chun, Sung-nam
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.483-489
    • /
    • 2005
  • This study performs a simulation for an accumulation mechanism of contaminants, which were produced in an industrial belt of inland, on the surface of insulators. From the simulation, silicon insulators presented higher accumulation than that of EPDM(Ethylene Propylene Diene Terpolymer : EPDM) insulators on the same distance in the case of the Virgin polymer insulator, and this result presented the same result in the insulator applied in actual fields. In the case of the accumulation test for the Virgin insulator and insulators used in actual fields, it is evident that the Virgin insulator presented more accumulation than that of the insulator used in actual fields. The results can be caused by the generation of LMW (Low Molecular Weight) on the external material of polymer insulators, and the level of the accumulation can be changed according to the degree of the continuous generation of LMW. In order to simulate a certain pollution of an industrial belt, which is located along the coastline, leakage currents were measured by applying the contaminant compulsively that was produced with salts and Kaolin according to the ratio of its weight on the surface of insulators. The more increase in the content of Kaolin pollution, the level of leakage currents on the surface of polymer insulator more increased. In addition, the approaching time to the maximum value of leakage currents presented a nearly constant level regardless of the content of Kaolin. The level of leakage currents significantly decreased according to the passage of time, and the level of leakage currents on the surface maintained a constant level at a specific time regardless of the content of Kaolin.

Evaluation of Heavy Metal Sources and Its Transfer and Accumulation to Crop in Agricultural Soils (농경지 토양의 중금속 오염원 및 농작물로의 중금속 전이·축적 평가)

  • Lim, Ga-Hee;Jo, Hun-Je;Park, Gyoung-Hun;Yun, Sung-Mi;Kim, Ji-In;Noh, Hoe-Jung;Kim, Hyun-Koo;Yoon, Jeong-Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.3
    • /
    • pp.27-42
    • /
    • 2018
  • It is important to identify the contaminant sources and to evaluate the fate and transport of heavy metals to crops in agricultural lands. This study was conducted to evaluate metal sources and its transfer and accumulation to crop in agricultural soils. Pollution indices were calculated and multivariate analysis was performed to identify metal sources. To evaluate transfer and accumulation of metals to crops, the contents of phytoavailable metals were evaluated by using single extraction method and the correlation between metal content and soil properties was analyzed. Also the BCF was quantitatively evaluated for investigating the metal transition to each crop grown in the research area. As a result, Cr, Ni, and Co were expected to be mainly derived from geologic factors due to weathering of certain parent rocks. The content of nickel in soils of the research area was slightly higher than that of the concern level criteria based on total concentration, but the amount transferred and accumulated in the crops was actually low. Understanding the contamination characteristics by investigating the pollution sources of heavy metals and its transfer and accumulation to crops through various evaluation techniques could provide important information for proper management of the agricultural land.

Investigation for TCE Migration and Mass Discharge Changes by Water Table Rising in Porous Media (투수성 매질 내에서의 지하수위 상승에 따른 TCE 거동특성 및 오염물 이동량 변화 연구)

  • Lee, Dong Geun;Moon, Hee Sun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.2
    • /
    • pp.27-35
    • /
    • 2013
  • In this study, three dimensional and two dimensional laboratory experiments were conducted to investigate the effect of water table rising on DNAPL migration, contaminants mass discharge ($M_d$), and residual NAPL distribution. The accumulation of TCE in unsaturated zone was observed in both two and three dimensional experiments. This implies DNAPL sources could exist in unsaturated zone at contaminated sites. It has been investigated that the TCE concentration is proportional to the areal ratio of residual TCE. This means the residual TCE obviously could affect the TCE concentration in aquifer system. The results of the two-dimensional experiment indicated that the contaminant sources in unsaturated zone could lead the $M_d$ increasing with water table rising and the source zone heterogeneity could also highly affect the $M_d$.

Developing a Numerical Model for Simulating In-Situ Biodegradation of an Organic Contaminant, TCE, in Biobarrier (생물벽체내 유기오염물질 TCE의 생물학적 분해 모의를 위한 수치모델개발)

  • 왕수균;오재일;배범한
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.4
    • /
    • pp.12-20
    • /
    • 2003
  • This study presents a mathematical model for simulating the fate and transport of a reactive organic contaminant, TCE, degraded by cometabolism in dual-porosity soils during the installation of in situ biobarrier. To investigate the effect of dual-porosity on transport and biodegradation of organic hydrocarbons, a bimodal approach was incorporated into the model. Modified Monod kinetics and a microcolony concept were employed to represent the effects of biodegrading microbes on the transport and biodegradation of an organic contaminant. The effect of permeability reduction in biobarrier due to biomass accumulation on the flow field were examined in the simulation of a hypothetical field-scale in situ bioaugmentation. Simulation results indicate that the presence of the immobile region can decrease the bioavailability of biodegradable contaminants and that the placement of microbes and nutrients injection wells should be considered for an effective installation of biobarrier during in situ bioaugmentation scheme.