• 제목/요약/키워드: Contact-loading

Search Result 523, Processing Time 0.031 seconds

Analysis of Internal Pressure Capacity of Modular Containment Structure for Small Modular Reactor (소형 원자로용 모듈화 격납구조의 내압성능 분석)

  • Park, Woo-Ryong;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.362-370
    • /
    • 2019
  • The internal pressure capacity of a modular containment structure requires analysis to prevent the release of radioactive material in the case of an accident. To analyze the capacity, FEM models were prepared while considering the tendon arrangements and the contact surfaces between precast concrete modules, and then static analyses were carried out. The changing characteristics in the displacement and stress under step-wise loading were analyzed, along with the effects of selected parameters. For comparison, the capacity of a monolithic containment structure was also analyzed. Parametric analyses were done to suggest ranges of parameters such as the tendon force, tendon spacing, tendon location in concrete thickness direction, friction coefficient, and concrete thickness. The tendon force and frictional force provide a combined effect between contact surfaces of modules. The same level of internal pressure capacity can be secured even in the modular containment structure as in the monolithic containment structure by increasing the tendon force with additional tendons.

An experimental investigation into the mechanism of the refrigerator contraction-expansion noise (냉장고 수축팽창 소음의 발생기구에 대한 실험적 규명)

  • Lee, Yeong-Gyu;Kim, Won-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.4
    • /
    • pp.389-396
    • /
    • 2022
  • This paper aims to identify the causes and mechanisms of contraction-expansion noise in refrigerators and proposes noise reduction methods. Contraction-expansion noise generated in refrigerators is mainly due to stick-slip phenomenon occurring on the contact surface between inner parts. Friction experiments were conducted to identify the factors causing the stick-slip phenomenon. Furthermore, the vibration level of the internal components was measured to determine the characteristics and location of the contraction-expansion noise. Based on the experimental results, experiments have been conducted to verify the noise characteristics for each factor. From this, it was confirmed that the friction experiment and the refrigerator contraction-expansion noise generation location and frequency were the same. The vibration level also increased as the vertical force was increased due to load loading. Also, it was confirmed that the contraction-expansion noise was reduced when the surface roughness was increased. Therefore, it was concluded that increasing the surface roughness of the contact surface in the same way as the results of the friction experiment was the method of reducing contraction-expansion noise.

Elastic-plastic Micromechanics Modeling of Cross-anisotropic Granular Soils: II. Micromechanics Analysis (직교 이방적 사질토의 미시역학적 탄소성 모델링: II. 미시역학적 해석)

  • Jung, Young-Hoon;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.3
    • /
    • pp.89-100
    • /
    • 2007
  • In the companion paper, we provided the novel elastic-plastic constitutive model based on the micromechanics theory. Herein, the elastic and elastic-plastic deformation of granular soils is meticulously analyzed. To guarantee high accuracy of the microscopic parameter, the systematic procedure to evaluate the parameters is provided. The analysis of the elastic response during the isotropic and triaxial compression shows that the stress-level dependency of cross-anisotropic elastic moduli is induced by the power relationship of the contact force in the normal contact stiffness, while the evolution of fabric anisotropy is more pronounced during triaxial compression. The micromechanical analysis indicates that the plastic strains are likely to occur at very small strains. The plastic deformation of tangential contacts has an important role in the reduction of soil stiffness during axial loading.

Shear behaviour of thin-walled composite cold-formed steel/PE-ECC beams

  • Ahmed M. Sheta;Xing Ma;Yan Zhuge;Mohamed A. ElGawady;Julie E. Mills;El-Sayed Abd-Elaal
    • Steel and Composite Structures
    • /
    • v.46 no.1
    • /
    • pp.75-92
    • /
    • 2023
  • The novel composite cold-formed steel (CFS)/engineered cementitious composites (ECC) beams have been recently presented. The new composite section exhibited superior structural performance as a flexural member, benefiting from the lightweight thin-walled CFS sections with improved buckling and torsional properties due to the restraints provided by thinlayered ECC. This paper investigated the shear performance of the new composite CFS/ECC section. Twenty-eight simply supported beams, with a shear span-to-depth ratio of 1.0, were assembled back-to-back and tested under a 3-point loading scheme. Bare CFS, composite CFS/ECC utilising ECC with Polyethylene fibres (PE-ECC), composite CFS/MOR, and CFS/HSC utilising high-strength mortar (MOR) and high-strength concrete (HSC) as replacements for PE-ECC were compared. Different failure modes were observed in tests: shear buckling modes in bare CFS sections, contact shear buckling modes in composite CFS/MOR and CFS/HSC sections, and shear yielding or block shear rupture in composite CFS/ECC sections. As a result, composite CFS/ECC sections showed up to 96.0% improvement in shear capacities over bare CFS, 28.0% improvement over composite CFS/MOR and 13.0% over composite CFS/HSC sections, although MOR and HSC were with higher compressive strength than PE-ECC. Finally, shear strength prediction formulae are proposed for the new composite sections after considering the contributions from the CFS and ECC components.

The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant (교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구)

  • Chung, Kyu-Rhim;Lee, Sung-Ja
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.173-185
    • /
    • 2001
  • The orthodontic osseointegrated titanium implant, a kind of intraoral skeletal anchorage can be an alternative to tooth-borne anchorage, in case that the conventional tooth-borne anchorage is not available or the anchorage is critical. This study was conducted to elucidate the effect of early loading on the osseointegration of the orthodontic titanium implant and the healing process of the impaired bone at the site of implant after removing it. In two adult beagle dogs24 osseointegrated titanium implants were inserted into the alveolar bone, with 12 implants placed in each dog. In dog1, 6 out of 12 implants were loaded with 200-300gm of force immediately after placing, and the remaining 6 implants were not loaded for 4weeks. In dog2, all 12 implants had healing period of 4weeks, and then were loaded with 200-300gm of force for another 4weeks. Following an observation period of 4 and 8 weeks, the animals were sacrificed. Then the implants and the surrounding bone of dog1 and dog2 were removed, respectively. Undecalcified sections along the long axis of implant were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features of tissues around implants anchored in dog1, there was no difference between immediately loaded implants and unloaded implants. Immature woven bone was ingrowing into the thread spaces from the original compacta and in direct contact with the implant surface in part. 2. The premature loading just after 4weeks healing period did not halt the progress of the osseointegration between bone and implant surface. The woven bone around the implants was maturing into the lamellar bone which resembled the structure of the original compacta at the end of 8weeks observation period. 3. Most implants with the inflammed surrounding mucosa were lost or mobile. The mobile implants were encapsulated by fibrous connective tissue which separated the implant surface from the bone. 4. The impaired bone at the site of the implant failed to anchor was showing recovery without inflammatory reaction 2weeks after removing, with the immaure woven bone lined by active osteoblasts and osteoid. Based on the results of this study, the integration of this orthodontic implant seemed to be impaired by the inflammation of the tissue surrounding the Implant rather than by early loading on implant, and increased with time lapsed after placing the implant. The use of implant described in this report can be recommended as an orthodontic anchorage unit immediately after insertion under the careful control of orthodontic force applied and plaque.

  • PDF

Finite Element Modeling and Nonlinear Analysis of Lumbosacrum Including Partial Ilium and Iliolumbar Ligaments (부분 장골과 장요추 인대를 포함한 요추 천추골의 유한 요소 모델링 및 비선형 해석)

  • Ha, S.K.;Lim, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.397-409
    • /
    • 2007
  • Owing to needs of biomechanical comprehension and analysis to obtain various medical treatment designs which are related with the spine in order to cure and diagnose LBP patients, the FE modeling and nonlinear analysis of lumbosacrum including a partial ilium and iliolumbar ligaments, were carried out. First, we investigated whether the geometrical configuration of vertebrae displayed by DICOM slice files is regular and normal condition. After constructing spinal vertebrae including a partial ilium, a sacrum and five lumbars (from L1 to L5)with anatomical shape reconstructed using softwares such as image modeler and CAD modeler, we added iliolumbar ligaments, lumbar ligaments, discs and facet joints, etc.. And also, we assigned material property and discretized the model using proper finite element types, thus it was completely modeled through the above procedure. For the verification of each segment, average sagittal ROM, average coronal ROM and average transversal ROM under various loading conditions(${\pm}10Nm$), average vertical displacement under compression(400N), ALL(Anterior Longitudinal Ligament) and PLL(Posterior Longitudinal Ligament) force at L12 level, strains of seven ligaments on sagittal plane at L45 level and maximal strain of disc fibers according to various loading conditions at L45 level, etc., they were compared with experimental results. For the verification of multilevel-lumbosacrum spine including partial ilium and iliolumbar ligaments, the cases with and without iliolumbar ligaments were compared with ROM of experiment. The results were obtained from analysis of the verified FE model as follows: I) Iliolumbar ligaments played a stabilizing role as mainly posterior iliolumbar ligaments under flexion and as both posterior and anterior iliolumbar ligaments of one side under lateral bending. 2) The iliolumbar ligaments decreased total ROM of 1-8% in total model according to various motion conditions, which changed facet contact forces of L5S level by approximately 0.8-1.4 times and disc forces of L5S level by approximately 0.8-1.5 times more than casewithout ilioligaments, under various loading conditions. 3) The force of lower discs such as L45 and L5S was bigger than upper discs under flexion, left and right bending and left and right twisting, except extension. 4) It was predicted that strains of posterior ligaments among iliolumbar ligaments would produce the maximum 16% under flexion and the maximum 10% under twisting. 5) It's expected that this present model applies to the development and design of artificial disc, since it was comparatively in agreement with the experimental datum.

Stability Characteristics based on Crane Weight of Small Fishing Vessels Under Standard Loading Conditions: Investigation Report of the Capsize Accident at Goseong Port (크레인 교체에 따른 표준재화 상태에서의 소형 어선의 복원성 특성 - 고성항 전복 사고 재결서 중심 -)

  • Kang, Dae Kon;Lee, Gun Gyung;Lee, Jun Ho;Han, Seung Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.1
    • /
    • pp.22-30
    • /
    • 2020
  • In March 2016, a 6.67-ton fishing boat capsized owing to the loss of stability during crane operations. Capsizing occurs when a boat or ship is flipped over (or turned upside down) for reason other than accidents caused by collisions, contact, stranding, fire or explosion. Over the past nine years (2010-2018), capsize accidents have accounted for 2.34 % of all marine accidents and are gradually increasing. The loss of stability from improper shipping is the main cause of most capsizes, especially for small fishing vessels weighing 10 tons. According to the Fishing Vessel Act, small fishing vessels weighing less than a ton are exempted from inspections on stability and load cranes. This study analyzes the issue cited as the reason for the capsizing of the small fishing boat in Goseong, namely, the reduction of restoring moment due to increased weight of the crane. Fishing boats with similar loading conditions were modeled on the basis of re-determination, and their stability before and after the accident was assumed. The fishing boats with heavier cranes were found to be at higher risk of capsizing owing to the reduction of the restoring moment and the angle of deck immersion. Under standard loading conditions, the stability moments of fishing vessels are lesser during fishing, compared to when they depart from or arrive at the port.

Effects of air-abrasion pressure on the resin bond strength to zirconia: a combined cyclic loading and thermocycling aging study

  • Al-Shehri, Eman Z.;Al-Zain, Afnan O.;Sabrah, Alaa H.;Al-Angari, Sarah S.;Dehailan, Laila Al;Eckert, George J.;Ozcan, Mutlu;Platt, Jeffrey A.;Bottino, Marco C.
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.206-215
    • /
    • 2017
  • Objectives: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide ($Al_2O_3$) particles at different pressures. Materials and Methods: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and ${\chi}^2$ tests (${\alpha}=0.05$). Results: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. Conclusions: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.

Compressibility and Stiffness Characteristics of Vanishing Mixtures (지반 소실 혼합재의 압축성 및 강성 특성)

  • Truong, Q. Hung;Eom, Yong-Hun;Yoon, Hyung-Koo;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.12
    • /
    • pp.103-111
    • /
    • 2008
  • Soils naturally contain grains of different minerals which may be dissolved under chemical or physical processes. The dissolution leads changes in microstructure of particulate media, such as an increase in local void or permeability, which affects the strength and deformation of soils. This study focuses on the small strain stiffness characteristics of vanishing mixtures, which consist of sand and salt particles at different volume fractions. Experiments are carried out in a conventional oedometer cell (Ko-loading) integrated with bender elements for the measurement of shear waves. Dissolutions of particles are implemented by saturating the mixtures at various confining stresses. Axial deformation and shear waves are recorded after each loading stage and during dissolution process. Experimental results show that after dissolution, the vertical strain and the void ratio increase, while the shear wave velocity and small strain shear modulus decrease. The decrease of the velocity results from the void ratio increase and particle contact decrease. The process monitoring during dissolution of the particles shows that the vertical strain dramatically increases at the beginning of the saturation process and converges after vanishing process finishes, and that the shear wave velocity decreases at the beginning and increases due to the particle reorientation. Specimens prepared by sand and salt particles are proved to be able to provide a valuable insight in macro structural behaviors of the vanishings mixtures.

Histomorphometry and Stability Analysis of Loaded Implants with two Different Surface Conditions in Beagle Dogs (하중을 가한 두 가지 표면의 임플란트에 관한 조직형태학적 분석 및 안정성 분석 (비글견을 이용한 연구))

  • Kim, Sang-Mi;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.337-349
    • /
    • 2008
  • Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in delayed loading conditions. A total of 36 solid screw implants (diameter 3.75 mm, length 10mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium Implants served as control. Gold crowns were inserted 3 months. Radiographic assessments and stabilitytests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 1 and 3 months after loading. Histological observations and morphometrical measurements were also performed. Of 36 implants, 32 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (p=0.413) and RFA values. The mean BIC % in the Mg-implants was $54.4{\pm}20.2%$. The mean BIC % in the turned implant was $48.9{\pm}8.0%$. These differences between the Mg-implant and control implant were not statistically significant (P=0.264). In the limitation of this study, bone-to-implant contact (BIC) and bone area of Mg-incorporated oxidized implant were similar to machine-turned implant. The stability analysis showed no significantly different ISQ values and marginal bone loss between two groups. Considering time-dependent bone responses of Mg-implant, it seems that Mg-implants enhanced bone responses in early loading conditions and osseointegrated similarly to cp Ti implants in delayed loading conditions. However, further investigations are necessary to obtain long-term bone response of the Mg-implant in human.