• 제목/요약/키워드: Contact-less Power Supply

검색결과 17건 처리시간 0.028초

3D Finite Element Analysis of Contact-less Power Supply with Linear Servo Motor

  • Woo, Kyung-Il;Park, Han-Seok;Park, Hyeong-Beom
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.190-196
    • /
    • 2007
  • This paper presents the 3D finite element analysis of the Contact-less Power Supply(CPS) with linear servo motor. The primary, secondary self and leakage inductances of the contact-less power supply and the capacitances of a resonant circuit are calculated by the finite element analysis using current source. The voltage source is used to do accurate analysis of the characteristics of the contact-less power supply. The CPS with the linear servo motor is proposed. The characteristics analysis of the contact-less power supply considering the linear servo motor is done.

Half-bridge 직렬공진 컨버터 적용 무접점 전원장치 효율특성 (Efficiency Characteristics of Half-bridge Series Resonant Converter for the Contact-less Power Supply)

  • 이현관;송환국;김은수;김윤호
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.884-891
    • /
    • 2007
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss and the high voltage gain characteristics for load variations in contact-less power supply (CPS). To consider these characteristics, in this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is presented, described and verified through theoretical analysis, computer simulation and experimental test of 2.5kW prototype.

$\cdot$병렬 공진형컨버터를 이용한 비접촉전원 (Contact-less Power Supply Using Series-Parallel Rasonant Converter)

  • 김은수;구대현;김종무;강도현;신병철;공영수;양승철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.103-107
    • /
    • 2002
  • A contact-less power supply system (CPS) allows electrical energy to supply to mobile consumers without any electrical or mechanical contact. CPS works in the same principle as a transformer, with the track litz cable forming the primary circuit and the pickup as the secondary. The track power supply generates the high frequency alternating current in the track cable. The captured AC magnetic field generated by the track conductors produces electrical energy in the pickup coil and the pickup rectifier converts the high frequency AC power to DC while regulating the power to the load. This paper presents the theoretical analysis, simulation and experiment리 results of the series-parallel resonant converter working as contact-less power supply system.

  • PDF

The characteristic analysis of contact-less Power supply by 3D finite element method

  • Park, Han-Seok;Cho, Yun-Hyun;Jung, Hong-Sub;Woo, Kyung-il;Kim, Kyung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.145-151
    • /
    • 2004
  • This paper proposes the calculation method of magnetic coupling coefficient of contact-less power supply by the 3D finite element method with a variation of the secondary core position. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. The magnetic coupling coefficients are obtained also. The power factors are obtained by simulation for the magnetic coupling coefficients and compared.

무접점 전원장치의 특성분석 (An Analysis on the Characteristics of the Contact-less Power Supply)

  • 이현관;이기식;정봉근;강성인;공영수;김은수;김윤호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.919-922
    • /
    • 2006
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss in contact-less power supply (CPS). In this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is analyzed and simulated. The results are verified on the simulation based on the theoretical analysis and the 1.8kW experimental prototype.

  • PDF

무접점 전원공급 시 1차측 전류를 이용한 금속 물질 검출에 관한 연구 (The Metal Detection using Primary Current in Contact-less Power Supply)

  • 김유석;유주희;김춘삼;성원기
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.445-452
    • /
    • 2012
  • The impurity detection method applied to existing discriminated the normality(R, L, C) and impurity(Metal) load using mutual RFID/ID method in the contactless power supply in which the primary side and the secondary side are completely separation by using the contactless transformer. However, this kind of system is caused the high cost of the system and complexity of control. Therefore, in this paper was proposed the contact-less power transfer using the primary current that determine normality or impurity load by compare the primary current Amplitude to reference quantity value and design the 3[W] contact-less power transfer and conduct an experiment for demonstrate the validity.

직류수용가 서비스를 위한 무접점 전원장치 (Contactless Power Supply for DC Power Service in Hybrid Home Generation System)

  • 강지원;송환국;김주훈;김은수;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.104-107
    • /
    • 2007
  • Among the alternative energy sources, the solar energy is recognized as an important energy source and its application is increasing. Especially in future, the hybrid solar energy generation system with battery will be widely used as an independent distributed power generation system. In this paper, a solar power hybrid home generation system using a contact-less power supply (CPS) that can transfer an electric power without any mechanical contact by using magnetic coupling instead of the power transfer by directly supplying the DC power to the home electric system is proposed. The proposed system consists of a ZVS boost converter, a half bridge LLC resonant converter and contact-less transformer.

  • PDF

태양광 발전 시스템을 위한 무접점 전원장치 (A Contact-less Power Supply for Photovoltaic Power Generation System)

  • 이현관;공영수;김윤호;이기식;강성인;정봉근;김은수
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.216-223
    • /
    • 2006
  • 태양광 발전 시스템을 위한 무접점 변압기 적용 고효율 Full-bridge LLC 공진컨버터를 제안하였다. 제안된 LLC 공진컨버터는 직렬 커패시터와의 직렬공진을 위해 무접점 변압기의 누설인덕턴스와 자화인덕턴스를 이용하였다. 제안된 LLC 공진컨버터는 공진주파수 보다 높은 스위칭영역에서 연속 공진전류로 동작하는 기존 직렬공진 컨버터와는 달리 공진주파수 아래의 좁은 주파수 범위에서 불연속 공진전류로 동작한다. 이러한 불연속모드 공진전류 때문에 제안된 컨버터는 어떤 보조회로 없이 무접점 변압기 1차측 주스위칭 소자의 영 전압 스위칭(ZVS)과 2차측 다이오드의 영 전류 스위칭(ZCS)을 얻을 수 있고, 높은 전압이득특성을 갖는다. 본 논문에서는 무접점 변압기 적용 Full-bridge LLC 공진컨버터를 이용한 무접점 전원장치에 대한 이론적 해석 및 시뮬레이션을 통해 150W급 시제품을 제작하여 태양광 발전 전원시스템에 적용 실험한 결과를 서술했다.

수용가 직류 서비스를 위한 무접점 전원장치 (Contactless Power Supply for DC Power Service in Hybrid Home Generation System)

  • 정봉근;강성인;김윤호;김은수
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.174-182
    • /
    • 2007
  • 신재생에너지 중에서 태양광 에너지가 중요 에너지원으로서 각광받고 있고 적용이 증대되고 있다. 특히, 미래에는 하이브리드 태양광 발전 시스템이 독립 분산 전원 시스템으로 널리 사용될 것으로 예상되고 있다. 본 논문에서는 DC전력을 기계적인 접촉에 의해 전달하는 것보다는 마그네틱 커플링에 의해 비접촉으로 에너지를 전달 할 수 있는 무접점전원장치를 사용한 직류수용가 서비스 태양광발전시스템을 제안하였다. 제안 적용된 무접점 전원장치는 무접점 변압기와 Half-bridge LLC 공진컨버터, 영 전압 스위칭 Boost컨버터로 구성되어 있다.

태양광 발전 시스템을 위한 LLC 직렬공진컨버터 적용 무접점 전원장치 (A Contact-less Power Supply using LLC resonant converter for Photovoltaic Power Generation System)

  • 이현관;이기식;강성인;공영수;김은수;김윤호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.347-350
    • /
    • 2006
  • The high efficiency full-bridge LLC resonant converter using a contact-less transformer is proposed for the photovoltaic power generation system. For the series resonance with a series capacitor, the LLC resonant converter utilizes the leakage inductance and magnetizing inductance of a contact-less transformer. Unlike the conventional series resonant converter operated to the continuous resonant current at above resonance frequency, the proposed converter operates to the discontinuous resonant current at the narrow frequency control range below resonance frequency. Due to the discontinuous mode resonant current, the proposed converter can be achieved the zero voltage switching (ZVS) in the primary switches and the zero current switching (ZCS) in the secondary rectification diodes without any auxiliary circuit. In this paper, the experimental results of the proposed full-bridge LLC resonant converter using a contact-less transfonner are verified on the simulation based on the theoretical analysis and the 150W experimental prototype.

  • PDF