• Title/Summary/Keyword: Contact state

Search Result 822, Processing Time 0.026 seconds

Determination of stress state in chip formation zone by central slip-line field

  • Andrey Toropov;Ko, Sung-Lim
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.577-580
    • /
    • 2003
  • Stress state of chip formation zone is one of the main problems in metal cutting mechanics. In two-dimensional case this process is usually considered as consistent shears of work material along single of several shear surfaces. separating chip from workpiece. These shear planes are assumed to be trajectories of maximum shear stress forming corresponding slip-line field. This paper suggests new approach to the constriction of slip-line field, which Implies uniform compression in chip formation zone. On the base of given model it has been found that imaginary shear line in orthogonal cutting is close to the trajectory of maximum normal stress and the problem about its determination have been considered. It has been shown that there is a second central slip-line field inside chip, which corresponds well to experimental data about stress distribution on tool rake face and tool-chip contact length. The suggested model could be useful in solution of various problems of machining.

  • PDF

Analytical solution of two-layer beam including interlayer slip and uplift

  • Kroflic, Ales;Planinc, Igor;Saje, Miran;Cas, Bojan
    • Structural Engineering and Mechanics
    • /
    • v.34 no.6
    • /
    • pp.667-683
    • /
    • 2010
  • A mathematical model and its analytic solution for the analysis of stress-strain state of a linear elastic two-layer beam is presented. The model considers both slip and uplift at the interface. The solution is employed in assessing the effects of transverse and shear contact stiffnesses and the thickness of the interface layer on behaviour of nailed, two-layer timber beams. The analysis shows that the transverse contact stiffness and the thickness of the interface layer have only a minor influence on the stress-strain state in the beam and can safely be neglected in a serviceability limit state design.

Physicochemical properties, cytotoxicity and penetration into dentinal tubules of sodium hypochlorite with and without surfactants

  • Hernan Coaguila-Llerena;Isadora Barbieri ;Mario Tanomaru-Filho ;Renato de Toledo Leonardo;Ana Paula Ramos ;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.47.1-47.11
    • /
    • 2020
  • Objectives: The aim of this study was to assess the physicochemical properties, cytotoxicity and penetration into dentinal tubules of ChlorCidTM Surf (3% sodium hypochlorite [NaOCl] with surfactant) in comparison to ChlorCidTM (3% NaOCl without surfactant). Materials and Methods: The physicochemical properties evaluated were pH, surface tension, free available chlorine (FAC) and contact angle. Cytotoxicity was evaluated in L929 fibroblasts exposed to the solutions by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide and neutral red assays. Assessment of penetration into dentinal tubules was performed by staining single-rooted permanent human teeth with crystal violet (n = 9), which were irrigated with the solutions and analyzed in cervical, middle and apical segments. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey's post-test, 2-way ANOVA and Bonferroni's post-test or t-test (α = 0.05). Results: ChlorCidTM Surf and ChlorCidTM FAC values were close to those indicated by the manufacturer. ChlorCidTM Surf showed lower surface tension and contact angle on dentin, and higher pH than ChlorCidTM (p < 0.05). The penetration of ChlorCidTM Surf was higher in cervical and middle segments, compared with ChlorCidTM (p < 0.05). There was no difference in irrigant cytotoxicity (p > 0.05). Conclusions: ChlorCidTM Surf showed lower surface tension, lower contact angle on root canal dentin, higher penetration into dentinal tubules and more alkaline pH, compared with ChlorCidTM. However, both solutions showed similar cytotoxicity and FAC content.

Study on the Development of Road Icing Forecast and Snow Detection System Using State Evaluation Algorithm of Multi Sensoring Method (복합 센서의 상태 판정 알고리즘을 적용한 노면결빙 예측 및 강설 감지 시스템 개발에 관한 연구)

  • Kim, Jong-Woo;Jung, Young-Woo;Nam, Jin-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.113-121
    • /
    • 2013
  • The road icing forecast and snow detection system using state evaluation algorithm of multi sensor optimizes snow melting system to control spread time and amount of chemical spread application This system operates integrated of contact/non-contact sensor and infrared camera. The state evaluation algorithm of the system evaluates road freezing danger condition and snowfall condition (snowfall intensity also) using acquired data such as temperature/humidity, moisture detection and result of image signal processing from field video footage. In the field experiment, it proved excellent and reliable evaluated result of snowfall state detection rate of 89% and wet state detection rate of 94%.

Finite element modeling of contact between an elastic layer and two elastic quarter planes

  • Yaylaci, Murat;Avcar, Mehmet
    • Computers and Concrete
    • /
    • v.26 no.2
    • /
    • pp.107-114
    • /
    • 2020
  • In this study, a two dimensional model of receding contact problem has been analyzed using finite element method (FEM) based software ANSYS and ABAQUS. For this aim finite element modeling of elastic layer and two homogeneous, isotropic and symmetrical elastic quarter planes pressed by means of a rigid circular punch has been presented. Mass forces and friction are neglected in the solution. Since the problem is examined for the plane state, the thickness along the z-axis direction is taken as a unit. In order to check the accuracy of the present models, the obtained results are compared with the available results of the open literature as well as the results of two software are compared using Root Mean Square Error (RMSE) and good agreements are found. Numerical analyses are performed considering different values of the external load, rigid circular radius, quarter planes span length and material properties. The contact lengths and contact stresses of these values are examined, and their results are presented. Consequently, it is concluded that the considered non-dimensional quantities have noteworthy influence on the contact lengths and contact stress distributions, additionally if FEM analysis is used correctly, it can be an efficient alternative method to the analytical solutions that need time.

The Subsurface Stress Field Caused by Both Normal Loading and Tangential Loading

  • Koo Young- Phi;Kim Tae-Wan;Cho Yong-Joo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.11
    • /
    • pp.1967-1974
    • /
    • 2005
  • The subsurface stress field caused by both normal loads and tangential loads has been evaluated using the rectangular patch solution. The effect of tangential loading on the subsurface stress field has been investigated in detail for both the cylinder-on-cylinder contact and a spur gear teeth contact. For the cylinder-on-cylinder contact, the subsurface stress fields are moved more to the direction of tangential loads and the positions where the maximum stress occur are getting closer to the surface with the increasing tangential loads. The subsurface stress fields of the gear teeth contact are expanded more widely to the direction of tangential loads with the increasing tangential loads. The friction coefficient of a gear teeth contact is low because they are operated in a lubricated condition, and therefore surface tractions in the EHL condition hardly affect on the subsurface stress field.

Non-Steady Elastohydrodynamic Lubrication Analysis on the Cam-Roller of Valve Mechanism for a Marine Diesel Engine (박용디젤기관 밸브기구용 캠-롤러 사이의 비정상상태 탄성유체윤활해석)

  • 구영필;강민호;이득우;조용주
    • Tribology and Lubricants
    • /
    • v.16 no.3
    • /
    • pp.201-207
    • /
    • 2000
  • The numerical procedure to analyze a non-steady 3-dimensional elastohydrodynamic lubrication on the cyclically loaded contact has been newly developed. The procedure was applied on the cam-roller contact of the valve mechanism for the marine diesel engine. Both the pressure distribution and the film thickness between the cam and roller follower were calculated for each time step of the whole cycle. The pressure spike is shown at the outlet of the roller edge and it is getting higher as the external load is increased. The film thicknesses in the result of the non-steady analysis have a tendency to increase compared to those in the result of the analysis with the assumption of steady state. Therefore, the surface roughness of the non-steady contact need not be limited below that of the steady contact of the equivalent operating conditions.

Monitoring/Control System for Cylindrical Plunge Grinding (원통 프런지 연삭공정의 감시/제어 시스템)

  • KIM, Sunho;Jung, Byung-Chul;Ahn, Jung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.9
    • /
    • pp.66-73
    • /
    • 1995
  • This paper presents monitoring and control system to decrease non-production time such as air grinding and partial contact in cylindrical plunge grindings. The 4-stage model of the plunge grinding process is proposed according to the state of contact between grinding wheel and workpiece; air grinding, partial contact, entire contact and spark out. Experimentally it is seen that the AE sensor and ultrasonic sensor are very effective to detect the grinding states. Monitoring and control algorithm using recognized grinding process was introduced and a experiment were conducted to verify the developed system.

  • PDF

Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA (ETA를 통한 연구실험실 콘센트회로의 전기재해 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.

A hysteresis model for soil-water characteristic curve based on dynamic contact angle theory

  • Liu, Yan;Li, Xu
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.107-116
    • /
    • 2022
  • The steady state of unsaturated soil takes a long time to achieve. The soil seepage behaviours and hydraulic properties depend highly on the wetting/drying rate. It is observed that the soil-water characteristic curve (SWCC) is dependent on the wetting/drying rate, which is known as the dynamic effect. The dynamic effect apparently influences the scanning curves and will substantially affect the seepage behavior. However, the previous models commonly ignore the dynamic effect and cannot quantitatively describe the hysteresis scanning loops under dynamic conditions. In this study, a dynamic hysteresis model for SWCC is proposed considering the dynamic change of contact angle and the moving of the contact line. The drying contact angle under dynamic condition is smaller than that under static condition, while the wetting contact angle under dynamic condition is larger than that under static condition. The dynamic contact angle is expressed as a function of the saturation rate according to the Laplace equation. The model is given by a differential equation, in which the slope of the scanning curve is related to the slope of the boundary curve by means of contact angle. Empirical models can simulate the boundary curves. Given the two boundary curves, the scanning curve can be well predicted. In this model, only two parameters are introduced to describe the dynamic effect. They can be easily obtained from the experiment, which facilitates the calibration of the model. The proposed model is verified by the experimental data recorded in the literature and is proved to be more convenient and effective.