• 제목/요약/키워드: Contact loss

검색결과 601건 처리시간 0.028초

350km/h 전차선로 집전성능 시험 및 결과 분석 (Analysis of Current Collection Performance Testing and Result of 350[km/h] Catenary System)

  • 허용석;이인희
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.365-369
    • /
    • 2016
  • The 350[km/h] catenary system was successfully opened in Honam high speed line. This 350[km/h] catenary system is firstly constructed in South Korea. Therefore the current collection performance of this system should be tested and evaluated by the authority. This paper describes the testings by running of HEMU-430X train and the evaluation criteria and result analysis to determine whether the performance of the catenary is good or not as a verification of catenary-pantograph interface. In detail, the contact force by pantograph, arcs by loss of contact and uplift amount of the catenary support were measured and discussed as a category of the current collection performance.

Iron Aluminide-$SiC_p$ 혼합 예비성형체를 사용한 Al합금기 복합재료의 내마모 특성 (Wear Resistance of Al Alloy Matrix Composites Using Porous Iron Aluminide-$SiC_p$ Preforms)

  • 차재상;오선훈;최답천
    • 한국주조공학회지
    • /
    • 제23권1호
    • /
    • pp.30-39
    • /
    • 2003
  • Porous hybrid preforms were fabricated by reactive sintering using the compacts consisting of SiC particles, Fe and Al powders. Squeeze casting processing was employed to produce the composite in which the matrix phase is Al-Si7Mg. The microstructural change and wear resistance of the composites were investigated in terms of an amount of SiC particles. The wear loss was increased with increasing the contact pressure in the alloy containing SiC particles coated with Cu. The most drastic change was found to the specimen tested at 2.5 MPa of contact pressure. Concerning the alloys containing SiC particles coated with Ni-P, a drastic increase in the wear loss exhibited at 2 MPa of contact pressure in those alloys containing 4 and 8 wt. % of SiC particles coated with Ni-P. In the alloy containing 16 wt. % a proportional increase in wear loss was observed to the change of contact pressure. With respecting to the sliding velocity, the wear loss of the alloy containing SiC particles coated with Cu increased at the initial stage of wear process and then decreased. Similar result was found in the alloys containing SiC particles coated with Ni-P. On the basis of the present results obtained, it was found that wear resistance of the alloys tested was improved to show in the order of the alloy reinforced by coated SiC particles > by uncoated SiC particles > by intermetallic compound without SiC particles.

Transient loss analysis of non-insulation high temperature superconducting coil using the field-based data profiling method

  • Hoon Jung;Yoon Seok Chae;June Hee Han;Ji Hyung Kim;Seung Hoon Lee;Ho Chan Kim;Young Soo Yoon;Ho Min Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권3호
    • /
    • pp.38-42
    • /
    • 2023
  • The evaluation of no-insulation (NI) high-temperature superconducting (HTS) typically uses the lumped equivalent circuit (LEC) model. Constant parameters in the NI HTS LEC model accurately predict voltage and central magnetic field at currents below the critical current. However, it is difficult to find constant circuit parameters that simultaneously satisfy the measured voltage and magnetic field under overcurrent conditions. Recent research highlights changes in contact resistance during transient conditions, which may impact power loss estimation in NI HTS coils. Therefore, we confirm the influence of contact resistance changes on loss calculation in the transient state for NI HTS coil. To achieve this, we introduce a measurement data analysis method based on the LEC model and compare it with the LEC model using constant circuit parameters.

단결정 실리콘 태양전지의 후면 전극형성에 관한 비교분석 (Analysis of the Formation of Rear Contact for Monocrystalline Silicon Solar Cells)

  • 권혁용;이재두;김민정;이수홍
    • 한국전기전자재료학회논문지
    • /
    • 제23권7호
    • /
    • pp.571-574
    • /
    • 2010
  • Surface recombination loss should be reduced for high efficiency of solar cells. To reduce this loss, the BSF (back surface field) is used. The BSF on the back of the p-type wafer forms a p+layer, which prevents the activity of electrons of the p-area for the rear recombination. As a result, the leakage current is reduced and the rear-contact has a good Ohmic contact. Therefore, the open-circuit-voltage (Voc) and fill factor (FF) of solar cells are increased. This paper investigates the formation of the rear contact process by comparing aluminum-paste (Al-paste) with pure aluminum-metal(99.9%). Under the vacuum evaporation process, pure aluminum-metal(99.9%) provides high conductivity and low contact resistance of $4.2\;m{\Omega}cm$, but It is difficult to apply the standard industrial process to it because high vacuum is needed, and it's more expensive than the commercial equipment. On the other hand, using the Al-paste process by screen printing is simple for the formation of metal contact, and it is possible to produce the standard industrial process. However, Al-paste used in screen printing is lower than the conductivity of pure aluminum-metal(99.9) because of its mass glass frit. In this study, contact resistances were measured by a 4-point probe. The contact resistance of pure aluminum-metal was $4.2\;m{\Omega}cm$ and that of Al-paste was $35.69\;m{\Omega}cm$. Then the rear contact was analyzed by scanning electron microscope (SEM).

전압리드의 배치가 단층 고온초전도 모델케이블의 교류손실 측정에 미치는 영향 (Effect of the voltage lead configurations on AC Loss Measurement in a Single Layer High-Tc Superconducting Model Cable)

  • 류경우;정재훈;황시돌;김석환
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권12호
    • /
    • pp.670-675
    • /
    • 2002
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting Power cables. The cables consists of a number of Bi-2223 tapes wound on a former. In such cables tapes have different critical current characteristics intrinsically. And they are electrically connected to each other and current leads by soldering. These make loss measurements considerably complex, especially for short samples of laboratory size. Special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work the at losses in a single layer model cable have been experimentally investigated for different contacts and arrangements of voltage leads. The results show that the losses are not dependent on both arrangements and contact positions of the voltage leads. This implies that loss flux is only in a cylindrical conductor section. The measured losses also agree well with those based on a monoblock model and are independent of frequencies. This means that the measured AC loss of the model cable is purely hysteretic in nature.e.

고속화에 대응한 전차선로 설계 요소기술 (Design Essential Element Technology of Catenary System be in Correspondence with Speed-up)

  • 창상훈;김양수;박병수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.75-78
    • /
    • 2005
  • The decisive criteria to determine collection performance is the contact force between pantograph and catenary. The contact force consists of a static force and dynamic force related to vibration characteristics, train speed and etc. The low contact force leads to the loss of contact, and most countries regulate it below 1% at operation speed. This study presents a technical overview of criteria for collection performance of catenary system.

  • PDF

도시철도 simple catenary 가선구조에서의 집전성능 향상방안에 관한 연구 (Study on the Current Collection Characteristics and Improvement Methods of Simple Catenary Systems)

  • 박용철;창상훈;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1360-1365
    • /
    • 2004
  • The decisive criteria to determine collection performance is the contact force between pantograph and catenary. The contact force consists of a static force and dynamic force related to vibration characteristics, train speed and etc. The low contact force leads to the loss of contact, and most countries regulate it below $3\∼5\%$ at operation speed. This study presents a technical overview of criteria for collection performance and modelling and simulation methods to analyze dynamic characteristics of catenary.

  • PDF

결정질 실리콘 태양전지에 적용하기 위한 후면전극 형성에 관한 연구 (An Analysis on rear contact for crystalline silicon solar cell)

  • 권혁용;이재두;김민정;이수홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.91.1-91.1
    • /
    • 2010
  • There are some methods for increasing efficiency of crystalline silicon solar cells. Among them, It is important to reduce the recombination loss of surface for high efficiency. In order to reduce recombination loss is a way to use the BSF(Back Surface Field). The BSF on the back of the p-type wafer forms a p+layer. so, it is prevented to act electrons of the p-area for the rear recombination. As a result, the leakage current is reduced and the rear-contact has a good Ohmic contact. therefore, open-circuit-voltage and Fill factor(FF) of solar cells are increased. This paper investigates the formation of rear contact process comparing Aluminum-paste(Al-paste) with Aluminum-Metal(99.9%). It is shown that the Aluminum-Metal provides high conductivity and low contact resistance of $21.35m{\Omega}cm$ using the Vacuum evaporation process but, it is difficult to apply the standard industrial process because high Vacuum is needed and it costs a tremendous amount more than Al-paste. On the other hand, using the Al-paste process by screen printing is simple for formation of metal contact and it is possible to produce the standard industrial process. however, it is lower than Aluminum-Metal(99.9) of conductivity because of including mass glass frit. In this study, contact resistances were measured by 4-point prove. each of contact resistances is $21.35m{\Omega}cm$ of Aluminum-Metal and $0.69m{\Omega}cm$ of Al-paste. and then rear contact have been analyzed by Scanning Electron Microscopy(SEM).

  • PDF

LPG 충전기에서 다수 볼-실린더의 구름마찰운동에 따라 달라지는 접촉거동특성에 관한 유한요소해석 (Finite Element Analysis of Contact Behavior Characteristics in LPG Filling Unit Depending on Multi-ball/Cylinder Rolling Friction Motions)

  • 김청균
    • 한국가스학회지
    • /
    • 제10권2호
    • /
    • pp.27-32
    • /
    • 2006
  • 본 논문은 다수의 볼과 접촉하는 두개의 실린더 사이에서 발생하는 접촉응력과 마찰력을 유한요소법으로 해석하였다. LPG 충전기는 구름마찰 운동을 위해 다수의 볼이 평행한 두개의 실린더와 경사진 두개의 실린더 레이스에서 구름마찰 운동을 한다. FEM 해석결과에 의하면, SiC 볼과 SUS 304 볼은 주어진 수직하중, 즉 압축력에 대하여 높은 접촉응력과 마찰력 손실을 보여주고 있다. 반면에 PEEK 볼을 두개의 실린더에 대하여 구름마찰 운동을 유지하면, 대단히 낮은 접촉응력과 마찰력 손실을 나타내는 것으로 보아 폴리머 소재의 사용은 저마찰 접촉특성을 잘 구현하고 있다할 수 있다. 여기에 두개의 실린더가 평행하게 구름마찰 접촉운동을 하느냐, 또는 경사진 상태에서 구름마찰 운동을 하느냐에 따라 접촉거동 특성이 크게 달라지므로 특히 두개 실린더 사이의 상대적 경사도는 극도로 억제되어야 우수한 설계가 된다.

  • PDF

열차 집전장치와 전차선 사이의 동적 접촉력 측정방법 개발 (Development of a Measuring Method for Dynamic Contact Forces between a Pantograph and a Contact Wire)

  • 조용현;최강윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.281-285
    • /
    • 2002
  • A new method of dynamic contact force measurement between a pantograph and a contact wire is proposed in this paper The method does not require design modification of an original pantograph in order to install sensors such as load cells. Contact forces can be expressed as the sum of vertical shear forces at the support points and inertial forces. Using specially-designed strain gage rosettes. vertical shear forces at the supported points can be measured without noise mixing and thermal effects. In order to obtain contact forces from shear forces, 3 inertial force compansation methods are proposed and compared in this paper. By validation process, the new proposed measurement method is verified to be applicable to the on-line current collection test.

  • PDF