Proceedings of the Korean Society of Machine Tool Engineers Conference
/
2003.10a
/
pp.324-328
/
2003
The Magnetoeheological fluid has the properties that it's viscosity has dramastic changed under some magnetic fields therefore, Magnetorhlogical fluids has been used for micro polishing of the micro part( for example, a aspherical surface in a micro lens). The polishing process may appears as follows. A part rotating on the spindle is brought into contact with an Magnetorhological finshing(MRF) fluids which is set in motion by the moving wall. In the region where the part and the MRF fulid ate brought into contact, the applied magnetic field creates the conditions necessary for the material removal from the part surface. The material removal takes place in a certain region contacting the surface of the part which can be called the polishing spot or zone. The polishing mechanism of the material removal in the contact zone is considered as a process governed by the particularities of the Bingham flow in the contact zone. Resonable calculated and experimental magnitudes of the material removal rate f3r glass polishing lends support the validity of the approach.
Proceedings of the Korean Society of Precision Engineering Conference
/
2003.06a
/
pp.1840-1843
/
2003
The Magnetorheological fluid has the properties that its viscosity has drastic changed under some magnetic fields therefore, Magnetorheological fluids has been used for micro polishing of the micro part( for example, a aspherical surface in a micro lens). The polishing process may appears as follows. A part rotating on the spindle is brought into contact with an Magnetorheological finishing(MRF) fluids which is set in motion by the moving wall. In the region where the part and the MRF fluid ate brought into contact, the applied magnetic field creates the conditions necessary for the material removal from the part surface. The material removal takes place in a certain region contacting the surface of the part which can be called the polishing spot or zone. The polishing mechanism of the material removal in the contact zone is considered as a process governed by the particularities of the Bingham flow in the contact zone. Resonable calculated and experimental magnitudes of the material removal rate for glass polishing lends support the validity of the approach.
Journal of the Korean Society for Precision Engineering
/
v.21
no.7
/
pp.46-52
/
2004
The Magnetorheological fluid has the properties that its viscosity has drastic changed under some magnetic fields therefore, Magnetorheological fluids has been used fur micro polishing of the micro part(for example, a spherical surface in a micro lens). The polishing process may appears as follows. A part rotating on the spindle is brought into contact with an Magnetorheological finishing(MRF) fluids which is set in motion by the moving wall. In the region where the part and the MRF fluid are brought into contact, the applied magnetic field creates the conditions necessary for the material removal from the part surface. The material removal takes place in a certain region contacting the surface of the part which can be called the polishing spot or zone. The polishing mechanism of the material removal in the contact zone is considered as a process governed by the particularities of the Bingham flow in the contact zone. Resonable calculated and experimental magnitudes of the material removal rate for glass polishing lends support the validity of the approach.
Purpose: The hydrogel lenses have been functionalized with HA(Hyaluronic Acid) using two different methods: construction of an IPN(Interpenetrating Polymer Networks) and formation of CCB(Chemical Covalent Bonding). The lysozyme adsorption and physical properties such as optical transmittance and water content of the hydrogel lenses have been investigated in order to determine whether method is suitable for the application potentials in contact lens industry. Methods: HA have been added to the hydrogel lenses prepared in the Lab using the two different method, e.g. IPN and CCB. The optical transmittance was measured in the wavelength range of 300~800 nm. The water content was measured by the gravimetric method using 0.9% NaCl saline solution. The amounts of adsorbed lysozyme on the contact lenses was analyzed by HPLC after incubation for 12h in artificial tears. Results: The water content of the HA added hydrogel contact lenses was increased, and the lens made by IPN method showed higher water content than the lens made by CCB method. The optical transmittance was over 90% both before and after addition of HA. Comparing the lysozyme adsorption reduction ratio, contact lens manufactured by IPN method was 60.0%, and the lens made by CCB method was 40.4%. Conclusions: CCB method is appropriate to distribute the functional material evenly throughout the lens, whereas IPN method is effective for the case of giving the functionality on the lens surface without phase separation.
In the present study, we performed the velocity field measurement in a microchannel using a focal length variable micro liquid lens. The liquid lens is used as a beam expander in a micro-PIV system to acquire the scatter image of the seeded particle. A thin film-type micro liquid lens was made of PDMS material and it was attached on top of the 700-micron-wide working fluid supply channel trench. As a result, the focal length and contact angle of the liquid lens changed with variations in applied pressure.
Purpose: To develop more accurate wet measuring system combining the wet cell, automatic lensmeter and the related software for hydrophilic contact lenses and to verify the accuracy of those measuring holder system already available in the market. Methods: Refractive power measurement were done in both a conventional method which has been commonly used in optical shops and a new method which is recently developed in korea. Hydrophilic contact lens of korean brand was chosen as a test material and was tested by water content ratio and by spherical refractive power. Results: When spherical power of -3.00 D contact lens is measured in the newly developed wet cell measurement holder with automatic lensmeter, it reads -3.01 D at water content ratio of 38%. -3.00 D at 45% and -2.98 D at 58%. The same experiment with the Poster soft contact lens wet cell measurement holder maintaining other conditions same resulted in -3.60 D at the water content ratio of 38%, -3.06 D at 45% and -2.46 D at 58%. Conclusions: At the higher water content, the refractive power values measured by both of the wet cell measuring holders are shown lower, and additionally, the new method using the wet cell holder and new software program in a automatic lensmeter showed more accurate readings than conventional Poster soft contact lens wet cell measuring system.
Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
Journal of Korean Ophthalmic Optics Society
/
v.19
no.2
/
pp.153-162
/
2014
Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.
Purpose: The aim of this study was to figure out how the characteristics of soft contact lens materials and pigmentation affect the adherence of C. albicans on soft contact lenses pre-deposited with tear constituents. Methods: The adherent number of C. albicans on clear soft contact lenses (hereinafter clear lenses) and circle soft contact lenses (hereinafter circle lenses) made of etafilcon A, hilaiflcon B and nelfilcon A, respectively, was measured before and after the deposition of artificial tear. Also, bacteria adherence on lenses were observed by a scanning electron microscope. Results: Adherence of C. albicans was significantly different according to lens materials. The amount of adsorption was not different between clear lenses and circle lenses made of etafilcon A however, the number of bacteria absorption was bigger in hilafilcon B and nelfilcon A lenses. More absorption of C. albicans was found in the non-pigmented central area compared the pigmented area, and non-pigmented peripheral area has more bacterial absorption than non-pigmented central area. The number of C. albicans decreased in the case that tear protein was pre-deposited. The maintenance of antibacterial activity against C. albicans was different according to lens materials thus, etafilcon A has the longest period of its maintenance. Conclusions: It was revealed that the number of C. albicans was different according to the characteristics of lens materials, pigmentation or non-pigmentation, the pigmented area of soft contact lenses. Thus, it is suggested that the management method should be different according to the adsorption characteristics of C. albicans.
Park, Mijung;Shin, Young Min;Chang, Ji Yeon;Kim, Daesoo
Journal of Korean Ophthalmic Optics Society
/
v.10
no.2
/
pp.91-97
/
2005
We investigated the question whether protein removing activities of enzyme cleaner - protein remover for soft contact lens - are associated with the material of soft contact lens as well as action time, temperature and pH of enzyme solution. We used a subtilisin cleaner as protein remover and estimated the protein amount remained on soft contact lens after using the subtilisin cleaner under the different conditions. The remained protein in soft contact lens was greatly decreased until treatment for 60min, but no significant differences were found from 60min to 24hr. The cleaning effect of the enzymatic treatment in the range of $15{\sim}30^{\circ}C$ was constant. however, there was a significant decline of the protein removing effect at $10^{\circ}C$ and less. The pH of the solution was also important for the efficacy of the enzymatic treatment. The activity of the enzyme cleaner was highest in pH 8.0 and significantly decreased a pH below 7. The pH dependence was found to be related to the conformational change of subtilisin. Furthermore, significant differences in the protein deposit removing efficacy of the subtilisin cleaner were found among the soft contact lens materials.
Kim, Tae-Hun;Yae, Ki-Hun;Kweon, Young-Seok;Sung, A-Young
Journal of Korean Ophthalmic Optics Society
/
v.11
no.3
/
pp.259-265
/
2006
We polymerized material of AA(Acrylic acid) and BMA(butyl methacrylate) to make up for the weak points of hydrogel contact lens. The synthesis process of silicone synthesis is as follows. Acrylate-PDMS(Polydimethylsiloxane)-Urethane prepolymer was composed after Diisocynate reacted with HEMA(2-hydroxyethylmethacrylate) under the catalyst and it reacted again with bis(hydroxyalkyl) terminated poly(dimethylsiloxane) with high oxygen transmissibility characteristics. HEMA(2-hydroxyethylmethacrylate) was used to make prepolymer that can be polymerized and the urethane was used to improve elasticity and oxygen transmissibility, copolymerization was performed with conventional hydrogel contact lens materials to make silicone hydrogel contact lens with higher oxygen transmissibility. For manufacturing of contact lens, We added BMA(Butyl methacrylate) with better elasticity and flexibility, and AA(Acrylic acid) with higher moisturizing to used contact lens materials. AIBN (Azobis2-methylpropionitrile) as initiator and EGDMA(Ethylene Glycol Dimethacrylat) as crosslinking agent were used and the lens with higher oxygen transmissibility and better moisturizing were manufactured complying with basic contact lens properties, which have several combination trial of each monomer characteristics. Compounding SN which included SILICONE, HEMA, NVP and EGDMA etc was showed by swelling ratio of 9.38% and water content of 23.7%. SN was showed by swelling ratio of 9.38%, water content of 23.7% and a visible ray transmissibility of 89%. SB which added BMA in the SN was showed by swelling ratio of 12.50%, water content of 18.56% and a visible ray transmissibility of 88%. SAB which added both AA and BMA in the SN was showed by swelling ratio of 8.33%, water content of 12.93% and a visible ray transmissibility of 88%.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.