• Title/Summary/Keyword: Contact intensity

Search Result 279, Processing Time 0.022 seconds

A study on the contactless generator and recharge system for a bicyle (비접촉식 자전거 발전기 및 충전 시스템 개발에 관한 연구)

  • Park, Wang-Geun;Won, Si-Tae
    • Design & Manufacturing
    • /
    • v.11 no.2
    • /
    • pp.29-36
    • /
    • 2017
  • In this study, the non-contact type bicycle generator system considering the recharge is developed to use the eco-friendly energy source when the bicycle is operating. The following three main factors are considered in this study. One of factors is that the intensity of the rotating magnet is in the range of 2,700~4,300 [Gause]. The next factor is that the separation distance of rotating magnet and bicycle rim is in the range of 1.5-3.0 mm. The last factor is that the pedaling speed is in the range of 55 RPM [Wheel speed 5.6Km]~150 RPM [Wheel speed 15.25Km] consirering with the 5 staged gear transmission. The obtained results are as followed. (1) The generator output voltage gradually increases from 3V to 10V with the pedaling speed increases, at the separation distance is less than 2.5 mm and the operating voltage of the LED lamp is generated at a pedaling speed of 60 RPM or more. (2) The output current of the generator increases from 20mA to 40mA with the pedaling speed increases, at a separation distance is less than 2.0 mm and the operating current of the LED lamp is generated at a pedaling speed of 60 RPM or more. (3) When the separation distance was 3.0 mm, the output voltage and current are significantly lower than those of the bicycle LED lamp is generated. (4) The charging time is expected to be 12.24 ~ 17.65 hours when the magnitude of the magnet is 3,400[Gauss] at a pedaling speed of 55 RPM or more. (5) As a result of this study, it is thought that the non-contact type bicycle generator system considering the recharge can replace the conventional friction power generation system.

Effect of Morphological Factors, Antibiotics and Agrobacterium Co-cultivation in the Efficiency of Somatic Embryogenesis of Eggplant (Solanum melongena L.)

  • Claudia Magioli;Erika Tarre;Krul, William-Robert;Elisabeth Mansur
    • Journal of Plant Biotechnology
    • /
    • v.3 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • Induction of somatic embryogenesis from Brazilian eggplant variety F-100 was studied in response to four auxin types. NAA, at the optimal concentration of 54 $\mu\textrm{m}$, was the only one that resulted in the induction of somatic embryos in either leaf and cotyledon explant and, at murk lower intensity and frequency, in hypocotyl and epicotyl explants. The optimal temperatures for embryo induction were 28 and 35$^{\circ}C$ for cotyledon and leaf explants. Incubation at 22$^{\circ}C$ caused a significant reduction both in the frequency and intensity of induction. This system was used to study the effects of position and orientation of the tissue on the culture medium as well as of antibiotics and explant co-cultivation with Agrobacterium on the efficiency of somatic embryo induction. The intensity of embryo induction was greater in the midsections of cotyledons relative to apical and basal regions, when the abaxial surface was in contact with the culture medium. The presence of antibiotics resulted in approximately 40-60% reduction of embryo induction relative to control explants, which originated 335$\pm$26.6 embryos. Co-cultivation with Agrobacterium before treatment with antibiotics caused a more drastic reduction (80-99%). Ampicilin treatment after cocultivalion with Agrobacterium caused the least inhibitory effect, allowing the production of 60 embryos/explant.

  • PDF

Initial bacterial adhesion on resin, titanium and zirconia in vitro

  • Lee, Byung-Chul;Jung, Gil-Yong;Kim, Dae-Joon;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.81-84
    • /
    • 2011
  • PURPOSE. The aim of this in vitro study was to investigate the adhesion of initial colonizer, Streptococcus sanguis, on resin, titanium and zirconia under the same surface polishing condition. MATERIALS AND METHODS. Specimens were prepared from Z-250, cp-Ti and 3Y-TZP and polished with $1 {\mu}m$ diamond paste. After coating with saliva, each specimen was incubated with Streptococcus sanguis. Scanning electron microscope, crystal violet staining and measurement of fluorescence intensity resulting from resazurin reduction were performed for quantifying the bacterial adhesion. RESULTS. Surface of resin composite was significantly rougher than that of titanium and zirconia, although all tested specimens are classified as smooth. The resin specimens showed lower value of contact angle compared with titanium and zirconia specimens, and had hydrophilic surfaces. The result of scanning electron microscopy demonstrated that bound bacteria were more abundant on resin in comparison with titanium and zirconia. When total biofilm mass determined by crystal violet, absorbance value of resin was significantly higher than that of titanium or zirconia. The result of relative fluorescence intensities also demonstrated that the highest fluorescence intensity was found on the surface of resin. Absorbance value and fluorescence intensity on titanium was not significantly different from those on zirconia. CONCLUSION. Resin specimens showed the roughest surface and have a significantly higher susceptibility to adhere Streptococcus sanguis than titanium and zirconia when surfaces of each specimen were polished under same condition. There was no significant difference in bacteria adhesion between titanium and zirconia in vitro.

Application of Fractal Dimension for Rubbed Surface Morphology of Hydraulic Members

  • Luy, M.R.;Jun, S.J.;Cho, Y.S.;Park, H.S.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.257-258
    • /
    • 2002
  • The surface morphology of oil-lubricated surface for hydraulic piston motor is believed to be extremely effective in contact mechanics. adhesion. friction and wear. In order to describe morphology of various rubbed surface on driving condition, the wear test was carried out under different experimental conditions in oil-lubricated system. And fractal descriptors was applied to rubbed surface of hydraulic members with image processing system. These descriptors to analyze surface structure are fractal dimension. Surface fractal dimension can be determined by sum of intensity difference of surface pixel. Morphology of rubbed surface can be effectively obtained by fractal dimension.

  • PDF

A Study of Atmospheric Plasma Treatment on Surface Energetics of Carbon Fibers

  • Park, Soo-Jin;Chang, Yong-Hwan;Moon, Cheol-Whan;Suh, Dong-Hack;Im, Seung-Soon;Kim, Yeong-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.335-338
    • /
    • 2010
  • In this study, the atmospheric plasma treatment with $He/O_2$ was conducted to modify the surface chemistry of carbon fibers. The effects of plasma treatment parameters on the surface energetics of carbon fibers were experimentally investigated with respect to gas flow ratio, power intensity, and treatment time. Surface characteristics of the carbon fibers were determined by X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), Fourier transform infrared (FT-IR), Zeta-potential, and contact angle measurements. The results indicated that oxygen plasma treatment led to a large amount of reactive functional groups onto the fiber surface, and these groups can form together as physical intermolecular bonding to improve the surface wettability with a hydrophilic polymer matrix.

Radiation characteristics on a stiffened plate structure (보강된 평판구조물의 음향방사특성에 관한 실험적 고찰)

  • Kang, Jun-soo;Kim, Jeung-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.879-886
    • /
    • 1998
  • It is very important to understand the vibration and noise characteristics of a structure to developed quiet machines and lessen their noise. In this paper, the vibration and sound radiation characteristics of a simple and a bar-stiffened plate have been investigated using numerical and experimental techniques. In numerical process, FEM analysis has been performed for the vibration level ; the time-space squared and averaged velocity and BEM analysis for sound radiation parameters ; sound power and radiation efficiency. In experimental process, FFT signal processing method has been used. While a power from an exiciter is applied to the structure by using a point contact, sound intensity and vibration level has been measured. Based on these two data, the radiation efficiency has been calculated. Results show that the radiation efficiency for the stiffened structure increases compared to the simple plate, due to the extra edges provided by the stiffener.

Fractal Dimension for Morphology Analysis of Rubbed Surface with Hydraulic Members

  • Cho, Yon-Sang;Seo, Young-Baek;Park, Heung-Sik
    • KSTLE International Journal
    • /
    • v.3 no.2
    • /
    • pp.75-78
    • /
    • 2002
  • The surface morphology of oil-lubricated surfaces fer hydraulic piston motors is believed to be extremely effective in contact mechanics, adhesion, friction and weak In order to describe morphology of various rubbed surfaces on driving conditions, the wear test was carried out under different experimental conditions in an oil-lubricated system. And fractal descriptors were applied to rubbed surfaces of hydraulic members and analyzed through an image processing system. These descriptors to analyze surface structure are fractal dimension. Surface fractal dimensions can be determined by sum of intensity difference of surface pixel. The morphology of rubbed surfaces can be effectively obtained by fractal dimension.

Disposable Nitrate-Selective Optical Sensor Based on Fluorescent Dye

  • Kim, Gi-Young;Sudduth, Kenneth A.;Grant, Sheila A.;Kitchen, Newell R.
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.209-213
    • /
    • 2012
  • Purpose: This study was performed to develop a simple, disposable thin-film optical nitrate sensor. Methods: The sensor was fabricated by applying a nitrate-selective polymer membrane on the surface of a thin polyester film. The membrane was composed of polyvinylchloride (PVC), plasticizer, fluorescent dye, and nitrate-selective ionophore. Fluorescence intensity of the sensor increased on contact with a nitrate solution. The fluorescence response of the optical nitrate sensor was measured with a commercial fluorospectrometer. Results: The optical sensor exhibited linear response over four concentration decades. Conclusions: Nitrate ion concentrations in plant nutrient solutions can be determined by direct optical measurements without any conditioning before measurements.

Noninvasive Detection of Radial Pulse Wave by Fiber-Optic Transducer (광파이버 트랜스듀서에 의한 맥파의 무침습적 검출)

  • 박승환;정동명
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.229-236
    • /
    • 1989
  • This paper describes an idea of design and construction for a radial pulse wave detector, In acquiring arterial pulse signal noninvasively, a new combinational fiber-optic transducer was used which has a detecting part and a sensing part. The mechanism of detecting part is composed of special form of structure that can detect changing pulses in contact with skin, and transmits arterial wall movements to the sensing part. It consists of elastic reflector and optical fibers, which are arranged in a fiber pair. Then, the intensity of the reflected light will be proportional to the displacement changed by inclined reflector. Using this transducer, it expected to make a clinically useful tool for arterial pulse wave diagnosis, especially on the application of "MACK- CHIN" in the field of Korean traditional medicine, since : his transducer has a simple structure and has an easy and clear signal acquisition method.on method.

  • PDF

Failure analysis about deterioration of Source voltage in Power MOSFET (Power MOSFET에서 Source voltage 저하에 관한 Failure analysis)

  • 정재성;김종문;이재혁;하종신;박상득
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1109-1112
    • /
    • 2003
  • 본 연구는 switching mode 의 Power NMOSFET failure mode 에 관하여 분석하고 원인을 규명하였다. 분석된 power NMOSFET은 30V급이며, vender A의 상용화 제품이다. 발생한 failure mode는 power switch 회로에서 특정 ID 를 detect 하지 못하는 mode 였다. 측정결과 source voltage 가 저하되었으며, power NMOSFET DC 동작특성 분석 결과 Vgs 변화에 따라 Id 가 저하되었다. Fail 된 power MOSFET 특성값 reference는 동일 LOT의 양품을 선정하였다. De-cap후 Inversion 과 Accumulation mode 별로 Photoemission spectrum analyzer(PSA) 분석 방법을 적용하였다. 결과 accumulation mode 에서 intensity가 감소하였으며, forward diode mode에서 국소적으로 변화하는 영역이 검출되었다. SEM 분석결과 gate metal 과 source metal 의 micro-contact 이 이루어져 있었다. 이 경우 gate metal 과 source metal 사이 close loop 를 형성하여 gate charge량을 변화시켜 power NMOSFET의 출력을 저하하는 failure mode가 발생됨을 분석할 수 있었다.

  • PDF