• Title/Summary/Keyword: Contact check

Search Result 162, Processing Time 0.021 seconds

Parallelization of sheet forming analysis program using MPI (MPI를 이용한 판재성형해석 프로그램의 병렬화)

  • Kim, Eui-Joong;Suh, Yeong-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.132-141
    • /
    • 1998
  • A parallel version of sheet forming analysis program was developed. This version is compatible with any parallel computers which support MPI that is one of the most recent and popular message passing libraries. For this purpose, SERI-SFA, a vector version which runs on Cray Y-MP C90, a sequential vector computer, was used as a source code. For the sake of the effectiveness of the work, the parallelization was focused on the selected part after checking the rank of CPU consumed from the exemplary calculation on Cray Y-MP C90. The subroutines associated with contact algorithm was selected as targe parts. For this work, MPI was used as a message passing library. For the performance verification, an oil pan and an S-rail forming simulation were carried out. The performance check was carried out by the kernel and total CPU time along with theoretical performance using Amdahl's Law. The results showed some performance improvement within the limit of the selective paralellization.

Non-contacting OMM (On Machine Measurement) based on CAD Model (CAD 모델 기반 비접촉 기상 측정에 관한 연구)

  • 권세진;이정근;박정환;고태조;김선호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.11
    • /
    • pp.134-141
    • /
    • 2003
  • An industrial product is designed and fabricated, followed by the inspection process in order to check whether it is dimensionally tolerable or not. The machining process produces a part such as a mold or die, in which the three-dimensional coordinate might be measured by a CMM (Coordinate Measuring Machine) for assessment of its dimension. It is not ignorable, however, that a CMM measurement requires a lot of operating time and cost, which has led to many studies on the OMM system. The OMM system can be categorized into contact and non-contact types, and each of which has its own strengths and weaknesses. Non-contacting types generally utilize structured lights, sounds or magnetic fields. Though they show rather poor performance in positional accuracy, the measuring speed is faster than the contacting probes. This paper presents the development of an OMM system based on a non-contacting laser displacement sensing apparatus and CAD model. The system is composed of software modules of center-aligning and measuring, which has been operated and verified on a NC machining center on a shop floor.

Import Patterns of Eyeglasses Industry (안경산업의 수입행태)

  • Hyun, Sung-Chul;Lim, Jun-Hyeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.11-17
    • /
    • 2009
  • Purpose: The purpose of this study is to provide an empirical overview of the import patterns of the Eyeglasses and Contactlens industry. Methods: This study used an Engle-Granger cointegration technique and Johansen's multivariate cointegraion methodology test to check the stationarity of the model. This paper also applies Rolling regression to our model, indicating that Eyeglasses and Contact Lens import is endogenous to the economic variable. Results: The empirical results show how the import in Eyeglasses and Contact Lens is related to the economic variables. Conclusions: This paper shows how the import of Eyeglasses and Contactlens is influenced by economic variables, such as exchange rate and industrial product, and seasonal factors.

  • PDF

EPDM Compounds for Electric Insulator (전기 절연용 EPDM Compounds)

  • Kim, In-H.;Hwang, S.H.;Kim, Jin-K.
    • Elastomers and Composites
    • /
    • v.34 no.5
    • /
    • pp.407-413
    • /
    • 1999
  • Non-ceramic composite insulator has been interested in the power industry because of its good characteristics in mechanical properties, mass product and design availability. Also it is lighter, and less unexplosive, compared to a ceramic insulator. Especially EPDM rubber composite insulator can be used for long-term in contaminated environments because of its hydrophobicity. This paper showed the rheological properties, the electrical properties, and contact angles to check the hydrophobicity and the recoverability of the EPDM compounds. Also, we investigated surface morphology of the compound by SEM.

  • PDF

Implementation of Wireless ECG Measurement System Attaching in Chair for Ubiquitous Health Care Environment (유비쿼터스 헬스 케어 적용을 위한 의자 부착형 무선 심전도 측정 시스템 구현)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Jee-Chul;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.776-781
    • /
    • 2008
  • In this study, ubiquitous health care system attaching in chair to monitor ECG for health care was developed at the unconsciousness state. The system conveniently and simple measured ECG at non-consciousness. We measured the contact impedance to skin-electrode of metal mesh electrodes of the system. Contact impedance enable the electrode to use for ECG measurement. The results are that the impedance of the metal mesh electrodes according to sizes is low when the size is 4$cm^2$. As the result, when the size of the metal mesh electrode is 4$cm^2$, the electrode is fit for ECG measurement. We can acquired by positing the arm on the metal mesh electrode. The ECG signal was detected using a high-input-impedance bio-amplifier, and then passed filter circuitry. The measured signal transmitted to a PC through the bluetooth wireless communication and monitored. Data of the non-constrained ECG system attaching in chair is noise-data when comparing metal mesh electrode with the Ag/Agcl electrode but the data is significant to monitor ECG for check the body state.

A Study on the Interface between a G7 Pantograph and a KTX Catenary System in Preparation for G7 On-line Tests in the Korea High Speed Test Track (고속 시험선 구간에서의 G7 본선 시운전에 대비한 G7 팬터그래프와 KTX 가선계와의 인터페이스 연구)

  • Cho, Yong-Hyeon;Kyung, Jin-Ho;Hur, Shin;Choe, Kang-youn;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.557-570
    • /
    • 2000
  • It is necessary to perform a study on the interrace between a G7 pantograph and a KTX catenary system prior to G7 on-line tests in the Korea High Speed Test Track in order to predict how high current collection quality can be obtained during the on-line tests and check if safety problems shall be caused b)Y the tests or not. According to the simulation results, current collection quality of the G7 pantograph at 350km/h is lower than that of a GPU pantograph at 300km/h, but the contact wire uplifts and average contact forces are within the safe-zone. In addition, the ratio of running speed (350km/h) to safe running. Therefore, the G7 on-line tests at 350km/h in the Korea High Speed Test Track is expected not to cause the safety problem.

  • PDF

Development of Fuel Rod Fretting Wear Tester (핵연료봉 프레팅마멸 시험기 개발)

  • 김형규;하재욱;윤경호;강흥석;송기남
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.245-251
    • /
    • 2001
  • A fretting wear tester is developed for experimental study on the fuel fretting problem of light water reactor. The feature of the developed tester is it can simulate the existence of gap between spring and fuel rod as well as different contacting force including the just-contact condition (0 N on the contact). Used are a servo-motor, an eccentric cylinder and lever mechanism for driving system. A spacer grid cell is constituted with four strap segments (each segment has a spring). This fretting wear tester can also be used as a fatigue tester of a spacer grid spring with the frequency of more than 10 Hz. It is required to simulate the frequency of the vibrating fuel rod due to flow-induced vibration in a reactor. In fretting wear test, up to two span-length of a fuel cladding tube can be accommodated. A specimen of cladding tube of one span-length is specially designed, which can be extended for two-span test. For .fatigue test, a device for clamping the spring fixture is installed additionally, Presently, the tester is designed for the condition of air environment and room temperature. The variation of the reciprocal distance is measured to check the stability of input force, which will be exerted to the cladding (for fretting wear. test) and the spring (for fatigue test) specimen.

  • PDF

Experimental and numerical analyses of RC beams strengthened in compression with UHPFRC

  • Thomaz E.T. Buttignol;Eduardo C. Granato;Tulio N. Bittencourt;Luis A.G. Bitencourt Jr.
    • Structural Engineering and Mechanics
    • /
    • v.85 no.4
    • /
    • pp.511-529
    • /
    • 2023
  • This paper aims to better understand the bonding behavior in Reinforced Concrete beams strengthened with an Ultra-High Performance Fiber Reinforced Concrete (RCUHPFRC) layer on the compression side using experimental tests and numerical analyses. The UHPFRC mix design was obtained through an optimization procedure, and the characterization of the materials included compression and slant shear tests. Flexural tests were carried out in RC beams and RC-UHPFRC beams. The tests demonstrated a debonding of the UHPFRC layer. In addition, 3D finite element analyses were carried out in the Abaqus CAE program, in which the interface is modeled considering a zero-thickness cohesive-contact approach. The cohesive parameters are investigated, aiming to calibrate the numerical models, and a sensitivity analysis is performed to check the reliability of the assumed cohesive parameters and the mesh size. Finally, the experimental and numerical values are compared, showing a good approximation for both the RC beams and the RC strengthened beams.

Comparison of Evaluation Methods for Disinfection Efficacy of Contact Lens Care Products (콘택트렌즈 관리용품의 살균력 효능 검사법 비교)

  • Sung, Hyung Kyung;Byun, Hyun Young;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose: The present study was aimed to compare the results of disinfection efficacy tested by membrane filtration method with dilution-neutralization method to develop the standard methods for evaluating disinfection efficacy of contact lens care products and to provide the result of disinfection efficacy of commercially available contact lens care products in domestic market. Methods: The results of disinfection efficacy against Staphylococcus aureus, Pseudomonas aeruginosa, Serratia marcescens, Candida albicans evaluated by membrane filtration method as a FDA standard and dilution-neutralization method as newly being a KFDA standard were compared and the disinfection efficacy of 16 multi-purpose solutions was further evaluated. Results: The disinfectants and contact lens care products having strong disinfection efficacy showed same results in both membrane filtration method and dilution-neutralization method. In case of contact lens care products having weak disinfection efficacy, the number of micro-organisms was not able to count since the colony was aggregated when evaluated by membrane filtration method. However, the number of micro-organisms was able to exactly count when evaluated by dilution-neutralization method. In addition, some commercially available contact lens care products did not meet disinfection standard and especially, their disinfection effect was often weak against Serratia marcescen and Candida albicans. Conclusions: It is concluded that dilution-neutralization method will be useful to evaluate disinfection efficacy since it is possible to count micro-organisms more precisely even with small amount of sample and check the results faster compared with membrane filtration method.

The Effect of Head Posture Change on Initial Occlusal Contact in Temporomandibular Disorder Patient (측두하악 장애환자에서 두부자세 변화가 초기 교합접촉에 미치는 영향)

  • Weon-Ho Choi;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.489-496
    • /
    • 1995
  • The purpose of this study was to evaluate an effect of change on head posture initial occlusal contacts with measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture in TMDs patient. For this study, 24 patients from age 13 to 36 were selected, they were examined health history taken, patients who have sign and symptoms of TMDs were examine before the study. For the normal group, 21 adults from age 23 to 25 were selected. They have normal or class I molar relationship, and have no other prosthetic restorations. Difference on distance between initial occlusal contact and maximum intercuspal position with mandibular kinesiograph$(MKG^R)$(K6 diagnostic system, Myo-tronic Inc, USA) in upright, supine, 45$^{\circ}$ extension, 30$^{\circ}$ flexion position of the head were measured. The Frankfort horizontal plane was used as a reference plane. The results were as follows : 1. There were significant differences between initial occlusal contacts of the normal and patient group on upright position and 30$^{\circ}$ flexion of the head(p<0.05, p<0.01) 2. The position of the initial occlusal contacts have a tendency to place anterior and inferior to maximal intercuspal position in upright position and 30( flexion of the head as well as posterior and inferior in supine position and 45$^{\circ}$ extension of the head in the normal and patient groups. 3. There were significant differences among the initial occlusal contacts between uptight and supine position; upright and 45$^{\circ}$ extension of the head(p<0.05); supine position and 30$^{\circ}$ flexion of the head, .and 30(flexion and 45$^{\circ}$ extension of the head in the patient group(p<0.01) The result have shown that after treatment on the supine position, it may be necessary to check occlusal contact on the upright position as well ass flexion of the head. It may need careful adjustment in occlusal condition on upright position of TMDs patient.

  • PDF