• Title/Summary/Keyword: Contact center

Search Result 1,818, Processing Time 0.028 seconds

Nano/Micro Friction with the Contact Area (접촉 면적에 따른 나노/마이크로 마찰 특성)

  • Yoon Eui-Sung;Singh R. Arvind;Kong Hosung
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.209-215
    • /
    • 2005
  • Nano/micro friction with the contact area was studied on Si-wafer (100) and diamond-like carbon (DLC) film. Borosilicate balls of radii $0.32{\mu}m,\;0.5{\mu}m,\;1.25{\mu}m\;and\;2.5{\mu}m$ mounted on the top of AFM tip (NPS) were used for nano-scale contact and Soda Lime glass balls of radii 0.25mm, 0.5mm, 1mm were used for micro-scale contact. At nano-scale, the friction between ball and surface was measured with the applied normal load using an atomic force microscope (AFM), and at micro scale it was measured using ball-on flat type micro-tribotester. All the experiments were conducted at controlled conditions of temperature $(24\pm1^{\circ}C)$ and humidity $(45\pm5\%)$. Friction was measured as a function of applied normal load in the range of 0-160nN at nano scale and in the range of $1000{\mu}N,\; 1500{\mu}N,\;3000{\mu}N\;and\;4800{\mu}N$ at micro scale. Results showed that the friction at nano scale increased with the applied normal load and ball size for both kinds of samples. Similar behavior of friction with the applied normal load and ball size was observed for Si-wafer at micro scale. However, for DLC friction decreased with the ball size. This difference of in behavior of friction in DLC nano- and microscale was attribute to the difference in the operating mechanisms. The evidence of the operating mechanisms at micro-scale were observed using scanning electron microscope (SEM). At micro-scale, solid-solid adhesion was dominant in Silicon-wafer, while plowing in DLC. Contrary to the nano scale that shows almost a wear-less situation, wear was prominent at micro-scale. At nano- and micro-scale, effect of contact area on the friction was discussed with the different applied normal load and ball size.

The Study for Voice Onset Types in Benign Vocal Fold Lesions (양성성대질환에서의 발성시작유형에 관한 연구)

  • Kim, Seong-Tae;Ahn, Cheol-Min;Nam, Soon-Yuhl
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.2
    • /
    • pp.131-135
    • /
    • 2009
  • Background and Objectives: Benign vocal fold lesions have shown various voice onset types on phonation, however, they have not been documented yet. We studied to know the relationships between benign vocal fold lesions and voice onset types. Materials and Method: 114 subjects were evaluated by using videokymographic examinations. The subjects were classified into three types: normal, contact, and open types according to the patterns of voice onset types on phonation. Benign vocal fold lesions were investigated and voice onset types were compared between normal and disease groups. Voice parameters were obtained from and compared in all subjects to assess acoustic and aerodynamic factors. Results: The normal type among onset types were more than contact type or open type in both normal and disease groups. Disease group showed many contact and open types when. compared with normal group. Vocal nodule and vocal polyp were showed many normal and contact types, however, sulcus vocalis was almost showed open type among voice onset groups. The values of mean flow rate (MFR) of contact type were significantly higher compared to normal type in disease group (p<0.05). Shimmer of contact type was higher than normal type in diseasegroup, but the difference was not significant (p=0.057). Conclusion: Benign vocal fold lesions were related to the various types of voice onset. The various types of voice onset should be considered when benign vocal fold lesions were examined.

  • PDF

Use of the Texas Eye Research and Technology Center Dry Eye Questionaire (TERTC-DEQ) as a Screening Survey for Contact Lens Wearers and Nonwearers (콘택트렌즈 착용자와 비착용자의 건성안 설문조사 TERTC-DEQ의 활용)

  • Kim, Jai-Min;Kim, Yong-Hwan;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.127-131
    • /
    • 2007
  • This study was designed to demonstrate the ability of Texas Eye Research and Technology Center Dry Eye Questionaire (TERTC-DEQ) to examine the distribution of self-reported dry eye symptoms and their diurnal intensity in university students and compare it with McMonnies & Ho DEQ. Two dry eye questionnaires were administered to 46 contact lens wearers and 47 nonwearers. Contact lens wearers scored higher on the TERTC-DEQ (52.2%) than McMonnies & Ho DEQ (6.5%). Non-contact lens wearers also scored higher on the TERTC-DEQ (19.1%) than McMonnies & Ho DEQ (2.1%). Ocular symptoms worsened with progression of time of day in both groups of subjects. This study suggests that TERTC-DEQ provides a first-choice diagnosis tool to obtain a comprehensive assessment of patient's symptoms, especially in comparison with McMonnies & Ho DEQ. The TERTC-DEQ is an efficient screening survey and may be use in dry eye diagnosis of contact lens-related dry eye.

  • PDF

Evaluation of Gas Metal Arc Welding Characteristics according to Contact Tip Materials (GMA용접에서 콘택트 팁 재질에 따른 용접특성 평가)

  • Kim, Dong Yoon;Hwang, In Sung;Kim, Dong Cheol;Kang, Moon Jin
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.35-40
    • /
    • 2014
  • The contact tip for gas metal arc welding has important functions to transmit the welding current to the wire and to guide the wire to molten pool. If the contact tip is damaged, it is a cause of lowering the welding productivity due to removal of welding defects and replacement of contact tip. In case of the use of a contact tip for a long time the arc is unstable because the processed hole in the contact tip center is larger, and the variation of aiming position of the welding wire causes a seam tracking error. In this study, gas metal arc welding experiments using contact tip of three different materials were performed. The contact tips with Cu-P, Cu-Cr, and Cu-ODS were used at the experiments, and the welding characteristics by each contact tip were evaluated. After welding contact tip appearance, welding spatter adhesion amount of the nozzle, and weld bead appearance were evaluated. The welding current and welding voltage were measured to verify arc stability during arc welding.

Dry Cleaning of Si Contact Hole using$UV/O_3$ Method ($UV/O_3$을 이용한 Si contact hole 건식세정에 관한 연구)

  • 최진식;고용득;구경완;김성일;천희곤
    • Electrical & Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.8-14
    • /
    • 1997
  • The UV/O$_{3}$ dry cleaning has been well known in removing organic molecules. The UV/O$_{3}$ dry cleaning method was performed to clean the Si wafer surfaces and contact holes contaminated by organic molecules such as residual PR. During the cleaning process, the Si surfaces were analyzed with X-ray photoelectron spectroscopy (XPS), atomic force microscope (AFM) and ellipsometer. When the UV/O$_{3}$ dry cleaning at 200'C was performed for 3 minutes, the residual photoresist was almost removed on Si wafer surfaces, but Si surfaces were oxidized. For UV/O$_{3}$ application of contact hole cleaning, the contact string were formed using the equipment of ISRC (Inter-university Semiconductor Research Center). Before Al deposition, UV/O$_{3}$ (at 200.deg. C) dry cleaning was performed for 3 minutes. After metal annealing, the specific contact resistivity was measured. Because UV/O$_{3}$ dry cleaning removed organic contaminants in contact holes, the specific contact resistivity decreased. Each contact hole size was different, but the specific contact resistivities were all much the same. Thus, it is expected that the UV/O$_{3}$ dry cleaning method will be useful method of removal of the organic contaminants at smaller contact hole cleaning.

  • PDF

Optimum Shoulder Height Design using Non-dimensional Shape Variables of Ball Bearing (볼 베어링의 무차원 형상변수를 이용한 최적 턱 높이 설계)

  • Choi, DongChul;Kim, TaeWan
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.37-43
    • /
    • 2019
  • This paper presents an optimization method to determine the shoulder height of an angular contact ball bearing by 3D contact analysis using nondimensional-shaped variables. The load analysis of the ball bearing is performed to calculate the internal load distributions and contact angles of each rolling element. From the results of bearing load analysis and the contact geometry between the ball and inner/outer raceway, 3D contact analyses using influence function are conducted. The nondimensional shoulder height and nondimensional load are defined to give the generalized results. The relationship between the shoulder height and radius of curvature of the shoulder under various loading conditions is investigated in order to propose a design method for the two design parameters. Using nondimensional parameters, the critical shoulder heights are optimized with loads, contact angles, and conformity ratios. We also develop contour maps of the critical shoulder height as functions of internal loads and contact angles for the different contact angles using nondimensional parameters. The results show that the dimensionless shoulder height increased as the contact angle and dimensionless load increased. Conversely, when the conformity ratio increased, the critical shoulder height decreased. Therefore, if the contact angle is reduced and the conformity ratio is increased within the allowable range, it will be an efficient design to reduce the shoulder height of ball bearings.

A contact investigation after exposure to a child with disseminated tuberculosis mimicking inflammatory bowel disease

  • Kim, Dongsub;Lee, Sodam;Kang, Sang-Hee;Park, Mi-Sun;Yoo, So-Young;Jeon, Tae Yeon;Choi, JoonSik;Kim, Bora;Choi, Jong Rim;Cho, Sun Young;Chung, Doo Ryeon;Choe, Yon Ho;Kim, Yae-Jean
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.11
    • /
    • pp.366-370
    • /
    • 2018
  • Purpose: Tuberculosis (TB) is one of the most important diseases that cause significant mortality and morbidity in young children. Data on TB transmission from an infected child are limited. Herein, we report a case of disseminated TB in a child and conducted a contact investigation among exposed individuals. Methods: A 4-year-old child without Bacille Calmette-$Gu{\acute{e}}rin$ vaccination was diagnosed as having culture-proven disseminated TB. The child initially presented with symptoms of inflammatory bowel disease, and nosocomial and kindergarten exposures were reported. The exposed individuals to the index case were divided into 3 groups, namely household, nosocomial, or kindergarten contacts. Evaluation was performed following the Korean guidelines for TB. Kindergarten contacts were further divided into close or casual contacts. Chest radiography and tuberculin skin test or interferon-gamma-releasing assay were performed for the contacts. Results: We examined 327 individuals (3 household, 10 nosocomial, and 314 kindergarten contacts), of whom 18 (5.5%), the brother of the index patient, and 17 kindergarten children were diagnosed as having latent TB infection (LTBI). LTBI diagnosis was more frequent in the children who had close kindergarten contact with the index case (17.1% vs. 4.4%, P=0.007). None of the cases had active TB. Conclusion: This is the first reported case of TB transmission among young children from a pediatric patient with disseminated TB in Korea. TB should be emphasized as a possible cause of chronic diarrhea and failure to thrive in children. A national TB control policy has been actively applied to identify Korean children with LTBI.

On the Contact Behavior Analysis and New Design of O-ring Seals

  • Kim, Chung-Kyun;Cho, Seung-Hyun;Kim, Young-Gyu
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.121-122
    • /
    • 2002
  • This paper presents contact behavior of an Polyperfluoroalkoxyethylene(PTFE) ring seals by a non-linear finite element method using the thermomechanical analysis. PTFE elastomer was assumed as odgen model for numerical analysis in FEM commercial code because elastomer has nonlinear behaviour character. The shape effects are investigated for sealing performance of ring seal in boundary conditions which as gas pressure, groove temperature and various O-ring seal models. Also contact stress and equivalent total strain are investicated. An O-ring seals was modeled four shape which are circle, two sunflower and X. The highest contact stress occurs at sunflower-ring seal with groove deapth of 0.35mm. the equivalent total strain of sunflower-ring seal is lower than that of the others under low gas pressure condition but under gas pressure condition over 4Mpa, that of sunflower-ring seal is higher. The calculated FEM results shows that the Sunflower-ring seal with groove depth of 0.35mm has excellent performance compared with other seal models.

  • PDF

Study on the Frictional Characteristics of Micro-particles for Tribological Application (미세입자의 트라이볼로지적 응용을 위한 마찰특성 고찰)

  • Sung, In-Ha;Han, Hung-Gu;Kong, Ho-Sung
    • Tribology and Lubricants
    • /
    • v.25 no.2
    • /
    • pp.81-85
    • /
    • 2009
  • Interests in micro/nano-particles have been greatly increasing due to their wide applications in various fields such as environmental and medical sciences as well as engineering. In order to obtain a fundamental understanding of the tribological characteristics at particle-surface contact interface, frictional behaviors according to load/pressure and materials were obtained by using atomic force microscope(AFM) cantilevers with different stiffnesses and tips. Lateral contact stiffnesses were observed in various tip-surface contact situations. Experimental results show that stick-slip friction behavior occurs even when the colloidal probes with a particle of a few micrometers in diameter, which have a relatively large contact area and lack a well-shaped apex, were used. This indicates that atomic stick-slip friction may be a more common phenomenon than it is currently thought to be. Also, experimental results were investigated by considering the competition between the stiffness of the interatomic potential across the interface and the elastic stiffnesses of the contacting materials and the force sensor itself.

Affecting Factors of End Colostomy-Related Complications (말단결장루의 합병증 발생 영향 요인)

  • Park, Seung Mi;Kim, Keum Soon
    • Korean Journal of Adult Nursing
    • /
    • v.19 no.4
    • /
    • pp.634-643
    • /
    • 2007
  • Purpose: This study was performed to investigate the type and frequency of end colostomy-related complications and to identify the risk factors for those complications. Methods: Retrospective analysis of medical records was made in 708 patients who underwent end colostomy in Samsung Medical Center between October 1994 and February 2005. The type was divided into stomal and peristomal complications: stomal complications included bleeding, necrosis, mucocutaneous separation, prolapsed stoma, retraced stoma, stenosis, and hyperplasia; peristomal complications did peristomal varix, peristomal hernia, irritant contact dermatitis, allergic contact dermatitis, maceration, folliculitis, hyperplasia, bacterial infection, candidal infection, malignancy in the peristomal area, mechanical damage and pyoderma gangrenosum. Results: For stomal complications, hyperplasia was most common(9.0%). For peristomal complications, irritant contact dermatitis was developed in 17.4%. Sex and BMI were risk factors for irritant contact dermatitis, hyperplasia, peristomal hernia, flat stoma, and retracted stoma. Conclusion: Teaching for preventing irritant contact dermatitis such as proper pouching and peristomal skin protection, and for comprehensive weight control should be emphasized on self care program for ostomates, while ostomy care nurse should take a careful consideration of preoperative ostomy site marking in female obese patients.

  • PDF