• 제목/요약/키워드: Contact Treatment

검색결과 1,608건 처리시간 0.032초

아르곤 저온 플라즈마 처리에 의한 CTA 필름의 접착성 연구 (A Study on Adhesive Properties of Cellulose Triacetate Film by Argon Low Temperature Plasma Treatment)

  • 구강;박영미
    • 한국염색가공학회지
    • /
    • 제16권5호
    • /
    • pp.28-34
    • /
    • 2004
  • The polarizing film application exploits the unique physicochemical properties between PVA(Poly vinyl alcohol) film and CTA(Cellulose triacetate) film. However, hardly any research was aimed at improving the adhesion characteristics of the CTA film by radio frequency(RF) plasma treatment at argon(Ar) gaseous state. In this report, we deal with surface treatment technology for protective CTA film developed specifically for high adhesion applications. After Ar plasma, surface of the films is analyzed by atomic force microscopy(AFM), roughness parameter and peel strength. Furthermore, the wetting properties of the CTA film were studied by contact angle analysis. Results obtained for CTA films treated with a glow discharge showed that this technique is sensitive to newly created physical functions. The roughness and peel strength value increased with an increase in treatment time for initial treatment, but showed decreasing trend for continuous treatment time. The result of contact angle measurement refer that the hydrophilicity of surface was increased. AFM studies indicated that no considerable change of surface morphology occurred up to 3 minutes of treatment time, but a considerable uneven of surface structure resulted from treating time after 5 minutes.

파스 접촉 알레르기 치료 중 연근 복용 후 악화된 중등도 알레르기 피부 1례 (A Case of Contact Dermatitis by Pain Relieving Patch Deteriorated after Taking Lotus Root)

  • 임경민;최정화;박수연;김종한;김선종;신정철;정민영
    • 한방안이비인후피부과학회지
    • /
    • 제28권3호
    • /
    • pp.126-134
    • /
    • 2015
  • Objectives : The purpose of this study is to report that Korean medical treatment is good for deteriorated moderate allergic skin after taking lotus root while getting treatment for contact dermatitis by pain relieving patch.Methods : A 54-year-old woman patient with allergic contact dermatitis received treatment with acupuncture, herbal medicine, etc. We used observation and Visual Anologue Scale(VAS) to evaluate recovery from erythema, pruritus and skin damages.Results : A visible symptoms to the naked eye and VAS scale were effectively decreased after Korean medicine treatments.Conclusions : Korean medical treatments were effective for allergic contact dermatitis deteriorated by lotus root while getting treatment contact dermatitis by pain relieving patch.

이온화가스와 응집공정을 조합한 축산폐수의 처리시 용존 유기물의 특성에 관한 연구 (Study of Soluble Organic Matter of Livestock Wastewater Treated by Ionized Gas and Coagulation after Ionized Gas)

  • 이은주;정팔진;김민정;현미희
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.708-713
    • /
    • 2004
  • This study was performed to investigate the variations of hydrophilic and hydrophobic organic matter fractions in soluble organic matter according to livestock wastewater treatment by ionized gas and coagulation effect to these fractions after ionized gas contact. As a result of experiment, because of ionized gas contact, particle in the surface of livestock wastewater was more smaller and the result was consisted of particle size analysis and the amount of small size was increased. Also, we confirmed that organic matters in livestock wastewater by ionized gas contact were removed. The relation equation between ionized gas contact time(X) and $TCOD_{cr}$(Y) was shown as yscale(y)=3.748-0.431* xscale(X). That between ionized gas contact time(X) and $TCOD_{cr}$(Y) was yscale(y)=3.283-0.463* xscale(X). As respects the HPL(hydrophilic matter)and HPO(hydrophobic matter) fractions of raw in livestock wastewater treatment plant, HPL fraction was 53.2% and HPO fraction was 46.8%. But, HPO fraction according to ionized gas treatment was increased at 30min and after that time, HPL fraction was increased. Also, when we performed coagulation process after ionized gas treatment of raw wastewater, the removal efficiency of organic matter was the highest at 30min of ionized gas treatment because of the variation of HPL and HPO fractions in organic matter by ionized gas. In coagulation process following after ionized gas process, HPO was removed more effective than HPL.

Improvement of Plating Characteristics Between Nickel and PEEK by Plasma Treatment and Chemical Etching

  • Lee, Hye W.;Lee, Jong K.;Park, Ki Y.
    • Corrosion Science and Technology
    • /
    • 제8권1호
    • /
    • pp.15-20
    • /
    • 2009
  • Surface of PEEK(poly-ether-ether-ketone) was modified by chemical etching, plasma treatment and mechanical grinding to improve the plating adhesion. The plating characteristics of these samples were studied by the contact angle, plating thickness, gloss and adhesion. Chemical etching and plasma treatment increased wettability, adhesion and gloss. The contact angle of as-received PEEK was $61^{\circ}$. The contact angles of chemical etched, plasma treated or both were improved to the range of $15{\sim}33^{\circ}$. In the case of electroless plating, the thickest layer without blister was $1.6{\mu}m$. The adhesion strengths by chemical etching, plasma treatment or both chemical etching and plasma treatment were $75kgf/cm^2$, $102kgf/cm^2$, $113kgf/cm^2$, respectively, comparing to the $24kgf/cm^2$ of as-received. In the case of mechanically ground PEEKs, the adhesion strengths were higher than those unground, with the sacrifice of surface gloss. The gloss of untreated PEEK were greater than mechanically ground PEEKs. Plating thickness increased linearly with the plating times.

자기세정을 위한 스퍼터링 TiO2 박막의 산소 표면처리에 따른 특성 (Effects of Oxygen Surface Treatment on the Properties of TiO2 Thin Film for Self-cleaning Application)

  • 김남훈;박용섭
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.294-297
    • /
    • 2016
  • Titanium oxide ($TiO_2$) thin films were fabricated by unbalanced magnetron (UBM) sputtering. The fabricated $TiO_2$ films were treated by oxygen plasma under various RF powers. We investigated the characteristics of oxygen plasma treatment on the surface, structural, and physical properties of $TiO_2$ films prepared at various plasma treatment RF powers. UBM sputtered $TiO_2$ films exhibited higher contact angle value, smooth surface, and amorphous structure. However, the rms surface roughness $TiO_2$ films were rough, and the contact angle value was decreased with the increase of the plasma treatment RF power Also, the hardness value of $TiO_2$ film as physical properties was slightly increased with the increase of the plasma treatment RF power. In the results, the performance of $TiO_2$ films for self cleaning critically depended on the with the plasma treatment RF power.

진공 저온 플라즈마와 대기압 코로나 방전가공 PET 직물의 물리화학적 특성 (The Physicochemical Characteristics of PET Fabrics Treated with Low Temperature Glow Plasma and Atmospheric Corona Discharge)

  • 마재혁;양진영;구강;양현아;박영미
    • 한국염색가공학회지
    • /
    • 제26권3호
    • /
    • pp.201-208
    • /
    • 2014
  • The high value-added functionality for synthetic fiber can be considered through a plasma enhanced treatment. In this study, PET(Polyethyleneterephthalate) was treated with a glow plasma and corona treatment. Surface characteristics of treated fabric were investigated using electron scanning microscopy(SEM), contact angle, X-ray photoelectron spectroscopy(XPS), tensile and adhesion strength. It was found that the contact angle showed $85.5^{\circ}$ for untreated fabric, $0^{\circ}$ for plasma and corona treatment at the condition of 200W for 7min. By XPS analysis, atomic ratio of O 1s/C 1s was increased from 0.27 to 0.43 by glow plasma and 0.27 to 0.41 by corona treatment at 200W for 7min, respectively. Glow plasma and corona treatment did not significantly change the tensile strength of PET fabric. Adhesion strength showed a substantial enhancement for the surface treated with the glow plasma, while corona treatment was adversely affected.

스테로이드 외용제로 악화된 알레르기성 접촉피부염 치험 1례 (A Case of Allergic Contact Dermatitis Aggravated by Steroid Ointment)

  • 송미사;윤화정;고우신
    • 한방안이비인후피부과학회지
    • /
    • 제31권3호
    • /
    • pp.107-115
    • /
    • 2018
  • Objectives : The purpose of this paper is to report the effect of Korean medicine treatments on allergic contact dermatitis aggravated after applying steroid ointment. Methods : We treated a 63-year-old woman with allergic contact dermatitis on the both forearm, jaw, neck, chest with Korean medicine. Before Korean medicine treatments she has taken oral steroids and applied steroid ointment for several years to treat dermatitis, but long-tern steroid therapy aggravated her symptoms like skin pruritus, erythema, exudates or edema. After Korean medical treatment for 27 days, we found that the size of erythema was reduced, and symptoms like pruritus, exudates and edema were lost. We recorded pictures of changes on symptoms. Results & Conclusions : The symptoms of allergic contact dermatitis were improved. Erythema, edema, exudate were lost. Thus Korean medicine treatments are effective on allergic contact dermatitis and could be a great alternative to steroid treatment.

CNx코팅된 강의 회전접촉피로에 미치는 코팅두께의 영향 (Effect of Coating Thickness on Rolling Contact Fatigue of CNx Coated Steel)

  • 최병영;노리츠구 우메하라
    • 열처리공학회지
    • /
    • 제13권5호
    • /
    • pp.355-359
    • /
    • 2000
  • Ion beam assisted deposition system was used to deposit CNx coatings with various thickness on the substrates of high-frequency induction hardened steels. Rolling contact fatigue tests were performed using Polymet RCF-1 machine with a constant supply of lubricant. Rolling contact fatigue life was substantially different in the steels with various thickness of CNx coatings. The optimum thickness of CNx coating was found to be $8.9{\mu}m$, showing the longest fatigue life, mainly caused by higher resistance to initiation of cracks and protective overcoat remaining to the surface failure during rolling contact fatigue. Cracks were initiated in the substrates under the surface of wear track and propagated to the surface, which eventually resulted in the failure. The reduction of fatigue life observed in the specimen with elimination of CNx coating during rolling contact fatigue was explained by the substrates deformation.

  • PDF

탄소성 유한요소법에 의한 박판성형 공정의 해석 II - 접촉 조건을 가지는 박판성형 공정의 해석 - (Elastic-Plastic Finite Element Analysis of Sheet Metal Forming Processes(II) - Analysis of Metal Forming Processes with Contact Condition -)

  • 심현보;정완진;양동열
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1129-1137
    • /
    • 1990
  • 본 연구에서 사용된 유한요소 방정식은 국부 질점좌표계(natural convected coordinate system)를 이용하여 변형을 묘사하는 대변형을 고려한 탄소성 증분 수식을 사용하였고, 국부 질점 좌표계를 사용함으로써 변형도 성분이나 구성 방정식의 성분들 에 대한 좌표 변환 과정을 생략할 수 있다. 재료는 수직 이방성으로 가정하였다.

E.M.G. biofeedback therapy에 의한 occlusal contact의 변화에 관한 련구 (A Study on the Changes of Occlusal Contacts after Electromyographic Biofeedback Therapy)

  • 김영주;이승우;김영구
    • Journal of Oral Medicine and Pain
    • /
    • 제10권1호
    • /
    • pp.33-39
    • /
    • 1985
  • Changes of occlusal contacts after E.M.G. biofeedback therapy with D.D.S. (Self control system, EMG 220, Sandiago California) was investigated in 20 SNUH students and residents with normal occlusion. Treatment time was 30 minutes on every subject. Occlusal contacts of before biofeedback therapy were taken at 4: 00 P.M. and that of after biofeedback therapy were taken at 4:40 P.M. Author compared the occlusal contacts before biofeedback therapy with that of after biofeedback therapy. The obtained results were as follow : 1. The number of occlusal contacts was 23.9, before biofeedback therapy and, 26.3, after biofeedback therapy. 2. The percentage of accentuated contact to diffuse contact was 78.5%, before treatment and 38.8% after treatment. 3. 6 heaviest contacts were changed 4.3 teeth per one subject after biofeedback therapy.

  • PDF