• Title/Summary/Keyword: Contact Treatment

검색결과 1,595건 처리시간 0.037초

Improvement of Corrosion Resistance of Aluminum Alloy with Wettability Controlled Porous Oxide films

  • Sakairi, M.;Goyal, V.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.166-170
    • /
    • 2016
  • The combined process of porous type anodizing and desiccation treatment was applied to improve wettability of A1050 aluminum alloy. The water contact angles of anodized samples were increaseds considerably with desiccation treatment. However, there was no considerable effect of polishing and anodizing time on water contact angle. The corrosion behavior with the treatments was investigated electrochemically. The corrosion resistance of the samples in 3.5 mass% NaCl solutions increased with higher contact angle. Anodized and desiccated samples showed better corrosion resistance than un-desiccated samples around rest potential region.

Hydrophobic treatment of various substrates by atmospheric pressure plasma

  • Lee, Kang-Jin;Kwon, Hye-Kyong;Lee, Hyung-Joo;Moon, Cheol-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1515-1518
    • /
    • 2009
  • Hydrophobic treatments were conducted for different kinds of substrates, glass substrate, silicon wafer and plastic substrate. Ar-$CH_4$ gas mixture was used as a discharge gas for the hydrophobic treatment. The change of the contact angle before and after treatment was measured and compared. Time evolution of the contact angle change after hydrophobic treatment was investigated.

  • PDF

Plasma Surface Treatment of the Polymeric Film with Low Temperature Process (저온프로세스를 이용한 고분자필름의 플라즈마 표면처리)

  • Cho, Wook;Yang, Sung-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제21권5호
    • /
    • pp.486-491
    • /
    • 2008
  • The plasma processing is applied to many industrial fields as thin film deposition or surface treatment technique. In this study, we investigated large-area uniformed surface treatment of PET film at low temperature by using Scanning Plasma Method(SPM). Then, we measured difference and distribution of temperature on film's surface by setting up a thermometer. We studied the condition of plasma for surface treatment by examining intensity of irradiation of uniformed plasma. And we compared contact angles of treated PET film by using Ar and $O_2$ plasma based low temperature. In our result, surface temperature of 3-point of treating is low temperature about $22^{\circ}C$, in other hands, there is scarcely any variation of temperature on film's surface. And by using Ar plasma treatment, contact angle is lower than untreatment or $O_2$ plasma treatment. In case of PET film having thermal weak point, low temperature processing using SPM is undamaged method in film's surface and uniformly treated film's surface. As a result, Ar plasma surface treatment using SPM is suitable surface treatment method of PET film.

Performance Evaluations of a Novel Prototype of High Frequency Non-Contact Power Transformer

  • Gamage, Laknath;Ishitobi, Manabu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권1호
    • /
    • pp.12-17
    • /
    • 2004
  • In this paper, a practical implementation to reduce leakage flux of a high-frequency inverter based non-contact type power transformer composed of EE-shape ferrite cores is presented for key technology of the next generation medical use X-ray CT scanner system. Design consideration for the unique structure of the non-contact power transformer with 900mm in diameter is also introduced. The complete non-contact transformer is actually arranged by several blocks of the magnetic circuit assembled by using 10 small EE shape cores with 120mm in length. It is experimentally and analytically discussed from a reduced leakage flux viewpoint related to its inductively coupling coefficient. A practical method to lower the leakage flux is described based on effective Copper-Sheet- Treatment placed on EE shape ferrite cores of magnetic circuit.

A Case of Dye-induced Contact Dermatitis Treated with Korean Medicine (염색약으로 유발된 접촉성 피부염의 한방 치험 1례)

  • Kim, Gyung-Jun;Yoo, Hee-Jo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • 제31권2호
    • /
    • pp.113-122
    • /
    • 2018
  • Objectives : The aim of this study is to report the case improved through Korean Medicine Including Herbal Medicine with Astragali radix, Rehmannia glutinosa as main ingredients, Acupuncture and External Preparation on the treatment of contact dermatitis. Methods : A patient with contact dermatitis was diagnosed through Korean Medicine and treated with Herbal Medicine with Astragali radix, Rehmannia glutinosa as main ingredients, Acupuncture and External preparation. The Degree of itching was assessed with Visual Analogue Scale(VAS) and the severity of wheals and redness on lesion site was assessed through photography. Results : VAS decreased from 9 to 1 and wheals and redness on lesion site was disappeared. Conclusions : According to the result, These findings suggest that Korean Medicine can be effective for the treatment of contact dermatitis.

Effects of Alloying Elements and Nitrocarburizing on Rolling Contact Fatigue Life (회전접촉피로수명에 미치는 합금원소 및 침질탄화처리의 영향)

  • Jin, Jai Koan;Kim, Dong Keon
    • Journal of the Korean Society for Heat Treatment
    • /
    • 제7권4호
    • /
    • pp.262-269
    • /
    • 1994
  • This study has been carried out to evaluate effects of alloying elements and nitrocarburizing on rolling contact fatigue life. Manganese has a significant influence on the distribution of retained carbides and microstructural changes after rolling contact fatigue test. The effect of the manganese addition stabilized fine retained carbide particles during rolling contact fatigue life test, and so increased fatigue life markedly. High carbon chromium bearing steel with different matrixes were nitrocarbunzed by austenitic nitrocarburizing process at $850^{\circ}C$ for 4hrs. Rolling contact fatigue life of the nitrocarburized specimen was increased 2 times than full hardening treated.

  • PDF

THE CONTACT LENS RELATED CASE REPORTS IN PEDIATRIC POPULATION II

  • Chen, Ai-Hong;Kim, Douk-Hoon;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제10권3호
    • /
    • pp.237-240
    • /
    • 2005
  • The cause of poor visual acuity was connected to the damage by the ocular trauma related. Especially the most cause of visual disorder was identified as irregular pupil by ocular damage. Therefore most patients stopped the wearing of the contact lens immediately by the visual decrease effects from irregular pupil disorder. But we had suggested that the contact lens wear was a very intensive visual therapy. We had identified the visual recover from several tests using the contact lens treatment.

  • PDF

The Molecular Structures of Poly(3-hexylthiophene) Films Determine the Contact Properties at the Electrode/Semiconductor Interface

  • Park, Yeong Don
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권8호
    • /
    • pp.2277-2280
    • /
    • 2014
  • The contact properties between gold and poly(3-hexylthiophene) (P3HT) films having either of two distinct molecular orientations and orderings were investigated. Thermal treatment increased the molecular ordering of P3HT and remarkably reduced the contact resistance at the electrode/semiconductor interface, which enhanced the electrical performance. This phenomenon was understood in terms of a small degree of metal penetration into the P3HT film as a result of the thermal treatment, which formed a sharp interface at the contact interface between the gold electrode and the organic semiconductor.

A Behavior of Rolling Contact Fatigue on Retained Austenite in High-Carbon Chromium Bearing Steel (고탄소 크롬 베어링 강에서의 잔류 오스테나이트 변화에 따른 회전접촉 피로거동)

  • Jin, Jai Koan;Kim, Dong Keon
    • Journal of the Korean Society for Heat Treatment
    • /
    • 제7권3호
    • /
    • pp.190-198
    • /
    • 1994
  • In order to study the effect of retained austenite on rolling contact fatigue in high-carbon chromium bearing steel, retained austenite was controlled by only tempering temperature, individually 200, 220 and $240^{\circ}C$. Among various microstructural alteration during rolling contact fatigue test, plate-like carbide most related to the flaking at sub-surface of contact pressure. The plate-like carbides formed during rolling contact fatigue test decrease with increasing tempering temperature, and fatigue life is much more improved. The retained austenite was decreased with the tempering temperature, and that decreased plate-like carbide formation. Therefore fatigue life is much more improved with decreasing retained austenite.

  • PDF

Characteristics of the Contact Angle Using the Microwave Plasma Treatment on Scintillator Panel Substrates (마이크로웨이브 플라즈마 처리를 통한 섬광체 패널 기판의 접촉가 특성변화)

  • Kim, Byoungwook;Kim, Youngju;Ryu, Cheolwoo;Choi, Byoungjung;Kwon, Youngman;Lee, Youngchoon;Kim, Myungsoo;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • 제8권1호
    • /
    • pp.43-47
    • /
    • 2014
  • By measuring decrease change of the contact angle after microwave plasma treatment on the glass and Al as a scintillator panel sample substrate, the adhesive performance of scintillator panel can be expected to improve. Also resolution and sensitivity of scintillator panel after microwave plasma treatment can be expected to maintain highly.