• Title/Summary/Keyword: Contact Power Supply System

Search Result 76, Processing Time 0.039 seconds

Prediction and Measurement for Harmonics on the Test Track of Seoul-Pusan High-speed Railway (경부고속철도 시험선 구간의 고조파예측 및 측정분석)

  • K. H. Oh;Lee, C. M.;M. S. Han;Lee, K. W.;K. S. Kwon;S. H. Chang;Kim, K. S.
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.100-107
    • /
    • 2000
  • This paper proposes a new model for harmonic analysis in 2${\times}$25㎸ traction power supply system including inverted feeder, contact line, rails and auto-transformer. The system model is based on four-port representation which is an extension of two-port network theory. In order to verify the proposed approach, we have analysed and tested real traction power feeding system focused on the amplification of harmonic current. The calculation results front tile proposed approach and the measurement data from the test are widely described in the paper.

  • PDF

A Study on the Trolley Sliding Condition Inspection System

  • Chang, ChinYoung;Kim, ChanSam;Jung, NoGeon;Na, YeonIl;Kim, YangSu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.109-112
    • /
    • 2015
  • The Korean electric railway is growing rapidly such as speed of 300km/h in high speed section and 230km/h in the conventional railway section. But, power supply failure occurs because of loss of contact, defective catenary system and high speed vehicle. Therefore preventive maintenance way based reliability has been applied. Typical example is the facility inspection method using trolley inspection system. But it is required differentiated inspection method to prevent problem such as inspection errors. In this paper, a study on the trolley sliding condition inspection system using monitoring techniques is performed for performance enhancement of inspection system. It proposed the efficient maintenance method through monitoring the deviation and height of contact wire after installing inspection system on the top of train which operates in the metropolitan area. Inspection errors were decreased by virtually monitoring the video of faulty facilities. Also those facilities were identified through the impact sound analysis and tests at the main catenary section.

A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line (350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구)

  • Lee, Hack-Pyo;Seo, Ki-Bum;Park, Jae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

Simulations for an ASCU of a Train Brake including a Pneumatic Model (공압모델이 포함된 철도차량 제동 ASCU 시뮬레이션)

  • Kim, Ho-Yeon;Kang, Chul-Goo
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.93-97
    • /
    • 2010
  • Wheel skids may occur during train operations due to low adhesion at the wheel-rail contact point abnormally, and the skids, in turn, result in flats appearing on the wheels, which affect safety and ride comfort significantly. Thus, anti-skid control has a crucial role for safe braking and prevention from flats that could cause a disastrous train accident. This paper presents simulation studies on an anti-skid control unit (ASCU) with a brake system of a rolling stock including a pneumatic model for brake power supply and dump valve operation.

  • PDF

Abnormal vibration of steam turbine due to carbon deposit at journal bearing in 500MW thermal power plant (탄소 고형물에 의한 터빈의 이상 진동)

  • 구재량;황재현;김연환;이우광
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.234-238
    • /
    • 2002
  • Lubricating oil supply system is an essential instrument for safe turbine operation. A lubricating condition may cause the abnormal vibration of turbine. In this paper we have discussed the abnormal vibration of turbine due to lubricating oil. Dusts of the air usually attach to end of the oil deflector and contact particles of the bearing oil. Dusts which were contacted particles of the bearing oil were changed into carbon deposit because of high temperature. therefore, carbon deposits occur abnormal vibration of the turbine when they contact a rotor. So, we have solved this problems through the various maintenance.

  • PDF

A Levitation Controller Design for a Magnetic Levitation System (자기부상 시스템의 부상제어기 설계)

  • 김종문;강도현;박민국;최영규
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.6
    • /
    • pp.342-350
    • /
    • 2003
  • In this paper, a levitation controller for a magnetic levitation(MagLev) system is designed and implemented. The target to be controlled is PEM(permanent and electromagnet) type with 4-corners levitation which is open-loop unstable, highly non-linear and time-varying system. The digital control system consists of a VME-based CPU board, AD board, PU board, 4-Quadrant chopper, and gap sensor, accelerometer as feedback sensors. In order to estimate the velocity of the magnet, we used 2nd-order state observer with acceleration and gap signal as input and output, respectively. Using the estimated states, a state feedback control law for the plant is designed and the feedback gains are selected by using the pole-placement method. The designed controller is experimentally validated by step-type gap reference change and force disturbance test.

Optimal Location and Design of RC-Bank on Korean Electric Railway System (한국 전기철도 시스템의 RC-Bank의 최적 위치 및 설계)

  • Lee Han-Min;Kim Gil-Dong;Oh Seh-Chan;Park Sung-Hyuk
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.754-764
    • /
    • 2005
  • This paper presents the RC-Bank installation by its optimal location and design to reduce harmonics on the Korean high-speed railway system. The system model of the Korean high-speed railway system is based on 8-port representation, which is an extension of 2-port network theory. A new proposed model is for harmonic analysis in $2\times27.5kV$ traction power supply system including feeders, contact lines, rails and autotransformers. The proposed model is developed by combining fundamental element models of the Korean high-speed railway system, and it is verified by comparing simulation results with measurement data regarding the amplification rate of harmonic currents.

  • PDF

Risk Analysis using Failure Data in Railway E&M System

  • Lee, Chang-Hwan;Song, Mi-Ok;Lim, Sung-Soo
    • International Journal of Railway
    • /
    • v.3 no.1
    • /
    • pp.34-37
    • /
    • 2010
  • In recent, the railway system consists of subsystems as rolling stock and infrastructures as signaling, telecommunication, power supply, overhead contact and platform screen door, etc. Furthermore, each subsystem has complicated interface so as not to understand these relationship. Consequently, to operate the railway system continuously with required safety and availability, the failure data should be corrected and analyzed systematically during operation. To achieve this object effectively, this paper presents the method which is evaluating the operational risk quantitatively using failure data, and selecting the critical equipment. Following this analysis, the improvement plan is established and applied to reduce the operational risk on system or equipment. From this study, the critical equipments of system could be determined and prioritized by risk analysis. Also, the effective maintenance to prevent critical failure could be implanted by this suggested methodology.

  • PDF

A Study on Evaluation of Daylighting in Office Space Applied BIPV Systems in Accordance with Power Performance (사무공간 적용 BIPV시스템의 자연채광 및 성능평가에 관한 연구)

  • Seo, Young-Seok;Oh, Min-Suk;Kim, Hway-Suh
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.148-154
    • /
    • 2009
  • By the skyscraper building, increase of skin area and expansion of curtain wall system will be the important factors of acceleration in extending supply of BIPV system. In the future interior environmental evaluation is not a necessary to the residents but an essential term which will bring enormous influence. In the interior environmental evaluation, natural light will let the residents with direct contact with outside circumstances and make them feel opened. also only the daylight has radiant energy and color rendering that will have a great influence to residents' mental, operation efficiency and advancing productivity. This research compares and analyzes BIPC system in office spaces with two general sunlight's module. In addition to natural light's efficiency for BIPC system's comfort and confirmed economical efficiency will be applied to basic research data. Hence forth, ensuring indoor intensity of illumination and controlling light system to reducing energy research data will be demanded to increase the amount of supplying BIPC system. Also continuance research in the possibility of applying BIPC system in various buildings, room temperature affected by location of windows and its condensation, and economical evaluation will be required.

  • PDF

Study on Power Line Coupler for Auxiliary Power to Overhead Line (철도 전차선의 보조전원을 위한 전력선 커플러 연구)

  • Lee, Gunbok;Yi, Kyung-Pyo;Kim, Myung Yong;Lee, Su Gil;Chang, Sang Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.7
    • /
    • pp.566-569
    • /
    • 2018
  • A power line coupler that can apply high-frequency power to a railway overhead line structure was analyzed. It is difficult to supply auxiliary power to an overhead line in a high-voltage environment, and doing so requires a long-distance transfer. A method is proposed that utilizes the resonance on the Rogowski coil, which does not use a magnetic core. A simple overhead line structure was fabricated that consisted of a contact wire, messenger wire, and dropper. Couplers of various sizes were fabricated and deployed on the messenger wire, and the transfer characteristics of the two couplers were compared at a distance. As a result of applying the matching circuit to the coupler, the transmission efficiency was 53% at a distance of 2.5 m. The proposed method shows that it is possible to apply the auxiliary power by using the existing conductor in a special structure, such as the overhead line.