• 제목/요약/키워드: Contact Noise

검색결과 613건 처리시간 0.025초

일측 성대마비 환자에서 성대내전술 후 성대접촉율의 증가가 음질 개선에 미치는 영향 (The Effect of An Increase of Closed Quotient on Improvement of Voice Quality after Type I Thyroplasty in Patients with Unilateral Vocal Cord Paralysis)

  • 김한수;최성희;임재열;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제15권1호
    • /
    • pp.16-20
    • /
    • 2004
  • Purpose : To assess perceptual, acoustic and aerodynamic measure of voice quality in patients with unilateral vocal cord paralysis before and after type I thyroplasty. Methods : The clinical records of patients operated type I thyroplasty in the Departement of otorhinoalryngolgy, Yongdong Severance hospital from November 2001 to November 2003 were reviewed. All patients uderwent a vocal function evaluation including perceptual, acoustic and aerodynamic measures of voice preoperative and on $60^{th}$ postoperative day. The perceptual and acoustic measures were obtained from recording of patients' reading a 'Sanchak' passage. The perceptual evaluation was performed by 2 speech pathologist using a 4-point rating scale. Acoustic parameters(voice range profile low(RAL), voice range profile high(RAH), average fundamental frequency(AFX), closed quotient, harmonic to noise ratio, jitter and shimmer) were investigated by Lx speech studio. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured using the Phonatory function analyzer. The maximum phonation time was also measured. The data were statistically analyzed. A paired t-test (p<0.1) was used to compare preoperative and postoperative results. And multiple regression test was used to find which parameter was most correlated to improvement of postoperative voice quality. Results : Among aerodynamic parameters, Psub $(88.11mmH_2O{\rightarrow}58.7mmH_2O)$, MPT(7.87sec${\rightarrow}$12.53sec), MFR (359.8ml/sec${\rightarrow}$161.06ml/sec) were statistically improved. AFx(205.5Hz${\rightarrow}$163.27Hz), AQx(23.9%${\rightarrow}$48.3%), RAL, RAH. Jotter and shimmer were improved. In multiple regression test, AFx and AQx was noted as the two meost correlated parameters to improvement of postoperative breathiness. But general grade of voice quality was more correlated to Psub and shimmer. Conclusion : Vocal fold medialization procedures effectively reduce glottic gap. Increasing of contact area of both vocal folds induced improvement in aerodynamic parameters and leaded stabilizing of vocal fold vibration. That effect results in improvement in acoustic parameters (shimmer, jitter, signal-to-noise ratio, voice range profile) and voice quality.

  • PDF

인쇄회로기판 진동이 커넥터에 미치는 영향 (Vibration Test for PCB/Connector Assembly)

  • 허남일;김성철;송규섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 추계학술대회논문집; 한국종합전시장, 24 Nov. 1995
    • /
    • pp.160-164
    • /
    • 1995
  • 정보통신 시스템의 고속/고밀도화 요구에 따라 개발되고 있는 ATM(Asynchronous Transfer Mode) 교환기 시스템은 팬을 이용한 강제대류냉각 방식의 채택과 시스템이 설치되는 장소에 따른 여러 환경조건에 의한 진동 문제가 발생될 수 있다. 시스템의 진동으로 인한 피해중 커넥터 접촉부에서 전기적 특성의 변화는 고속으로 전송되는 신호의 왜곡을 유발시킬 수 있어 시스템 개발시 이에 대한 충분한 연구 및 시험이 요구되고 있다. 진동환경에서 커넥터 접촉부는 접촉면의 상대운동으로 인한 접촉저항의 증가와 순간적인 신호전달 중단을 가져오게 되며, 특히 PCB/Connector Assembly에서 커넥터 접촉부는 PCB(Printed Circuit Board)의 장착 조건 및 동적 거동에 따라 전기적 특성이 변할 수 있다. 시스템에서 커넥터의 동적 거동을 이해하기 위해서는 PCB를 포함하는 시스템내 여러 요소의 동적 특성 이해와 복잡한 해석과정이 요구되며, 시스템 개발자는 진동 환경에서 이것의 시험 결과에 따라 커넥터의 사용을 결정해야 할 것이다. 커넥터의 전기적 특성 시험법은 IEC, EIA드 여러 국제 규격에 제시되어 있으며, 본 연구의 대상이 된 ATM교환기 시스템에서 PCB/Connector Assembly의 진동환경에서 접촉저항 측정과 관련된 접촉저항 임계치 및 측정법은 IEEE 규격 및 Bellcore 규격에 규정되어 있다. Bellcore에는 주어진 진동시험주기 전후에 IEC 규격의 LLCR(Low Level Contact Resistance) 측정회로를 이용한 측정법이 규정되어 있고, 냉각팬 및 주위 환경진동이 가해지는 동안의 영향에 대한 시험법은 규정되어 있지 않다. 본 연구에서는 한국통신의 전자장비 운용환경시험 조건의 진동에서 ATM 교환기 시스템에 사용되는 PCB/Connector Assembly 커넥터 접촉부의 접촉저항 변화와 PCB 진동에 의한 영향을 시험하였다.proach)등이 제시되었고 평면파 영역에 한하여 해서되어져 왔다. 본 논문에서는 분할 접근 방법(Segmentation Approach)을 이용하여 다공 요소로 이루어진 소음기를 해석하는데 적용하였다.로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity v

  • PDF

SH-EMAT의 신호 수신을 위한 광섬유 패브리-페롯 간섭계 센서의 적용 (Application of a Fiber Fabry-Pérot Interferometer Sensor for Receiving SH-EMAT Signals)

  • 이진혁;김대현;박익근
    • 비파괴검사학회지
    • /
    • 제34권2호
    • /
    • pp.165-170
    • /
    • 2014
  • 수평횡파(SH-wave)는 배관과 같은 박판 구조물에서 판파 모드로 전파하고 분산성이 단순하여 구조물의 건전성 평가에 유용하다. 전자기초음파탐촉자(EMAT)는 비접촉식으로 자석과 코일 배열을 조절하여 수평횡파를 발생하기 용이하다. 따라서 수평횡파 전자기초음파탐촉자(SH-EMAT)를 이용한 자동화 검사 시스템은 박판 구조물 건전성 감시에 매우 유용하다. 하지만 발전설비 또는 자동화 장비 등에서는 전자기노이즈가 상당히 많이 발생하고 EMAT 수신 센서는 전자기노이즈에 취약한 면이 있다. 광섬유 센서는 빛을 이용하여 전자기노이즈 환경에서 매우 유용하게 활용될 수 있다. 본 연구에서는 이러한 환경적 제약을 고려하여 광섬유 패브리-페롯 간섭계(FFPI)를 SH-EMAT으로 발생되는 초음파의 수신용 센서로 제안하였다. 평판시험편에서 SH-EMAT의 신호를 FFPI 센서를 이용하여 수신하고 이 신호에 대한 분석을 하였다. 제안된 FFPI 센서가 EMAT으로 가진된 SH wave의 신호를 명료하게 수신할 수 있음을 확인하였다.

선택적 Si 확산을 이용한 저저항층을 갖는 이온주입 GaAs MESFET (Fabrication of ion implanted GaAs MESFET with Si selectively diffused low resistive layer)

  • 양전욱
    • 전자공학회논문지D
    • /
    • 제36D권3호
    • /
    • pp.41-47
    • /
    • 1999
  • SiN로부터 GaAs로 확산된 Si을 이용하여 소스와 드레인 영역에 고농도 Si 확산층을 갖는 GaAs MESFET를 제작하였다. 제작된 MESFET의 소스와 드레인 영역은 950°C, 30초의 열처리에 의해 Si 확산층이 표면에서부터 350Å두께로 형성되어 확산층이 없을 때 1000Ω/sq.정도였던 면저항이 400Ω/sq.로 내외로 감소하였다. 고농도로 확산된 Si은 AuGe/Ni/Au와 GaAs 기판 사이의 저항성 접촉 특성을 2.5×10\sub -6\Ω-cm\sup 2\로부터 1.5×10\sup -6\Ω-cm\sup 2\로 개선시켰다. 제작된 lum게이트 길이의 확산층을 갖는 MESFET는 최대 트랜스컨덕턴스가 260mS/mm 이었으며, 이득과 최소잡음지수는 12GHz에서 각각 8.5dB와 3.57dB를 나타내 같이 제작된 표면 확산 층이 없는 MESFET에 비해 1.3dB와 0.4dB가 향상되었다.

  • PDF

전자 전단 간섭법을 이용한 압력용기의 내부결함 측정에 관한 연구(I) (A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography(I))

  • 강영준;박낙규;유원재;김경석
    • 비파괴검사학회지
    • /
    • 제22권4호
    • /
    • pp.393-401
    • /
    • 2002
  • 원자력 발전소나 화학공장 등에서 사용되는 보편적인 부재중 하나인 압력배관은 사용중에 내부에 부식 등의 원인으로 결함이 발생되어 구조적 강도나 안전에 문제를 야기한다. 따라서, 이런 결함의 검출은 중요한 문제이다. 현재 신뢰성이 인정되어 사용되는 기존의 비파괴검사법으로는 초음파 X선 그리고 와전류에 의한 방법 등이 있다. 그렇지만 이러한 방법들은 검사하고자 하는 대상과 거의 접촉에 가까운 형태로 검사가 진행되고 있으며, 결함은 넓은 영역에 걸쳐 한번에 검출되지 못하고 탐촉자나 필름이 위치하는 부분으로 검사영역이 한정되는 단점이 있다. 그래서 검사에 많은 시간과 경비가 소모되고 있다. 본 연구에서는 이러한 단점들을 극복할 수 있는 레이저를 이용한 전자 전단 간섭법으로 결함을 측정하였다. 그리하여 압력용기의 내부에 존재하는 다양한 결함의 유무와 결함의 방향을 변위구배를 나타내는 간섭무늬로 검출하고, 검출된 결함에 위상 이동법을 적용하여 정량적으로 측정할 수 있었다. 본 연구는 두 편으로 구성된다. 그 첫 번째는 전자 전단 간섭법을 이용한 압력용기의 내부결함 검출에 관한 연구이고, 두 번째는 그 측정시스템의 오차분석에 관한 연구로 구성되어 있다.

DLP용 유체동압베어링 스핀들모터 (Fluid Dynamic Bearing Spindle Motors for DLP)

  • 김응철;성세진
    • 전기학회논문지P
    • /
    • 제60권2호
    • /
    • pp.82-90
    • /
    • 2011
  • The small precision spindle motors in the high value-added products including the visible home appliances such as DLP projector require not only the energy conversion devices but also high efficiency, low vibration and sound operation. However, the spindle motors using the conventional ball bearing and sintered porous metal bearing have following problems, respectively: the vibration by the irregularity of balls and the short motor life cycle by the ball's abrasion and higher sound noises by dry contact between shaft and sleeve. In this paper, it is proposed that the spindle motor with a fluid dynamic bearing is suitable for the motor to drive the color wheel of the DLP(digital lightening processor) in the visible home appliances. The proposed spindle motor is composed of the fluid dynamic bearing with both the radial force and the thrust force. The fluid dynamic bearing is solved by the finite element analysis of the mechanical field with the Reynolds equations. The magnetic part of spindle motor, which is a type of Brushless DC Motor, is designed by the electro-magnetic field analysis coupled with the Maxwell equation. And the load capacity and the friction loss of fluid dynamic bearing are analyzed to bearing clearance variation by the fabrication error in designed motor. The design of the proposed motor is implemented by the load torque caused by the eccentricity and the unbalance of the fluid dynamic bearing when the motors are fabricated in error. The prototype of the motor with the fluid dynamic bearing is manufactured, and experiment results show the vibration, sound, and phase current at no load and color wheel load of the motors in comparison. The high performance characteristics with the low vibration, the low acoustic noise and the optimal mechanical structure are verified by the experimental results.

3T MREIT 시스템을 이용한 실험견 사체의 두부 도전율 영상 (Conductivity Imaging of a Canine Head using a 3T MREIT System with a Carbon-Hydrogel Electrode: Postmortem Experiment)

  • 정우철;김영태;;김형중;이태휘;강병택;박희명;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권2호
    • /
    • pp.179-184
    • /
    • 2009
  • Magnetic Resonance Electrical Impedance Tomography (MREIT) is a new bio-imaging modality providing cross-sectional conductivity images from measurements of internal magnetic flux densities produced by externally injected currents. Recent MREIT studies demonstrated successful conductivity image reconstructions of postmortem and in vivo canine brain. However, the whole head imaging was not achieved due to technical issues related with electrodes and noise in measured magnetic flux density data. In this study, we used a new carbon-hydrogel electrode with a large contact area and injected 30 mA imaging current through a canine head. Using a 3T MREIT system, we performed a postmortem canine experiment and produced high-resolution conductivity images of the entire canine head. Collecting magnetic flux density data inside the head subject to multiple injection currents, we reconstructed cross-sectional conductivity images using the harmonic $B_z$ algorithm. The conductivity images of the canine head show a good contrast not only inside the brain region including white and gray matter but also outside the brain region including the skull, temporalis muscle, mandible, lingualis proprius muscle, and masseter muscle.

The Performance Improvement of a Linear CCD Sensor Using an Automatic Threshold Control Algorithm for Displacement Measurement

  • Shin, Myung-Kwan;Choi, Kyo-Soon;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1417-1422
    • /
    • 2005
  • Among the sensors mainly used for displacement measurement, there are a linear CCD(Charge Coupled Device) and a PSD(Position Sensitive Detector) as a non-contact type. Their structures are different very much, which means that the signal processing of both sensors should be applied in the different ways. Most of the displacement measurement systems to get the 3-D shape profile of an object using a linear CCD are a computer-based system. It means that all of algorithms and mathematical operations are performed through a computer program to measure the displacement. However, in this paper, the developed system has microprocessor and other digital components that make the system measure the displacement of an object without a computer. The thing different from the previous system is that AVR microprocessor and FPGA(Field Programmable Gate Array) technology, and a comparator is used to play the role of an A/D(Analog to Digital) converter. Furthermore, an ATC(Automatic Threshold Control) algorithm is applied to find the highest pixel data that has the real displacement information. According to the size of the light circle incident on the surface of the CCD, the threshold value to remove the noise and useless data is changed by the operation of AVR microprocessor. The total system consists of FPGA, AVR microprocessor, and the comparator. The developed system has the improvement and shows the better performance than the system not using the ATC algorithm for displacement measurement.

  • PDF

주파수 체배기와 PLL을 이용한 10 GHz 생체 신호 레이더 시스템 (Novel 10 GHz Bio-Radar System Based on Frequency Multiplier and Phase-Locked Loop)

  • 명성식;안용준;문준호;장병준;육종관
    • 한국전자파학회논문지
    • /
    • 제21권2호
    • /
    • pp.208-217
    • /
    • 2010
  • 본 논문에서는 주파수 체배기와 위상 동기화 회로(Phase-Locked Loop: PLL)를 이용한 주파수 합성기를 이용한 10 GHz 대역에서 동작하는 생체 신호 레이더를 제안하였다. 제안된 10 GHz 대역 생체 레이더는 2.5 GHz 전압 제어 발진기와 PLL을 이용하여 발생된 위상 잡음 특성이 매우 뛰어나고 안정적인 정현 신호를 이용하여 뛰어난 생체 신호 검출 성능을 보인다. 또한 10 GHz 대역에서 PLL을 구현하기 어려운 점을 해결하기 위하여 2.5 GHz 대역에서 PLL을 이용하여 발생된 신호를 주파수 체배기를 이용하여 10 GHz 대역 신호를 발생시키는 방법을 제안하였다. 본 논문에서는 제안된 구조의 생체 레이더의 잡음 특성을 이론적으로 분석하여 제안된 구조의 타당성을 검증하였다. 실험 결과 100 cm까지 매우 우수한 생체 신호 검출이 가능하였으며, 이로서 제안된 구조의 10 GHz 대역의 생체 레이더의 타당성을 확인하였다.

호흡 및 심박수 측정을 위한 비 접촉 방식의 2.4 GHz 바이오 레이더 시스템 (An 2.4 GHz Bio-Radar System for Non-Contact Measurement of Heart and Respiration)

  • 이용진;장병준;육종관
    • 한국전자파학회논문지
    • /
    • 제19권2호
    • /
    • pp.191-199
    • /
    • 2008
  • 본 논문에서는 호흡 및 심박수 측정을 위한 2.4 GHz 바이오 레이더 시스템의 성능을 분석하고 이를 통한 설계 및 구현 과정을 제시하였다. 먼저 2.4 GHz 시스템의 성능을 정량적으로 분석하기 위해, 인체 조직의 전자기적 성질을 이용하여 사람 몸에 의한 손실을 구하였고, 거리에 따른 복조기 출력에서의 SNR을 분석하였다. 5 Hz 대역폭일 때, 50 cm에서 90 % 이상의 success ratio를 성능지표로 삼아 바이오 레이더 성능을 MATLAB을 이용하여 시뮬레이션 하였고, 전체 시스템의 링크 버젯을 완성하였다. 분석 결과를 활용하여 4층 PCB 기판 위에 계산된 링크 버젯을 만족하는 직접 변환 방식의 바이오 레이더 수신기를 설계 및 제작하였다. 측정 결과, 0 dBm 출력에서 5 Hz 대역폭일 때, 50 cm의 거리에서 약 80 %의 success ratio가 측정되어 설계 과정을 검증하였다.