• 제목/요약/키워드: Contact Noise

검색결과 613건 처리시간 0.035초

Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography (두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향)

  • Eun-Hye, Kim;Young-Cheol, Joo;Han-Yong, Kim;Dong-Hwan, Kim
    • Journal of radiological science and technology
    • /
    • 제45권6호
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

Noise Analysis and Measurement for a CW Bio-Radar System for Non-Contact Measurement of Heart and Respiration Rate (호흡 및 심박수 측정을 위한 비접촉 방식의 CW 바이오 레이더 시스템의 잡음 분석 및 측정)

  • Jang, Byung-Jun;Yook, Jong-Gwan;Na, Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제19권9호
    • /
    • pp.1010-1019
    • /
    • 2008
  • In this paper, we present a noise analysis and measurement results of a bio-radar system that can detect human heartbeat and respiration signals. The noise analysis including various phase noise effects is very important in designing the bio-radar system, since the frequency difference between the received signal and local oscillator is very small and the received power is very low. All of the noise components in a bio-radar system are considered from the point of view of SNR. From this analysis, it can be concluded that the phase noise due to antenna leakage is a dominant factor and is a function of range correlation. Therefore, the phase noise component with range correlation effect, which is the most important noise contribution, is measured using the measurement setup and compared with the calculated results. From the measurement results, our measurement setup can measure a closed-in phase noise of a free-running oscillator. Based on these results, it is possible to design a 2.4 GHz bio-radar system quantitatively which has a detection range of 50 cm and low power of 1 mW without additional PLL circuits.

Heart Rate Signal Extraction by Using Finger vein Recognition System (지정맥 인식 시스템을 이용한 심박신호 검출)

  • Bok, Jin Yeong;Suh, Kun Ha;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • 제9권6호
    • /
    • pp.701-709
    • /
    • 2019
  • Recently, heart rate signal, which is one of biological signals, have been used in various fields related to healthcare. Conventionally, most of the proposed heart rate signal detection methods are contact type methods, but there is a problem of discomfort that the subject have to contact with the device. In order to solve the problem, detection study by non-contact method has been progressed recently. The detected heart rate signal can be used for finger vein liveness detection and various application using heart rate. In this paper, we propose a method to obtain heart rate signal by using finger vein imaging system. The proposed method detected the signal from the changes of the brightness value in the time domain of the infrared finger vein images and converted it into the frequency domain using the image processing algorithm. After the conversion, we removed the noise not related to the heart rate signal through band-pass filtering. In order to evaluate the accuracy of the signal, we analyzed the correlation with the signal obtained simultaneously with the finger vein acquisition device and contact type PPG sensor approved by KFDA. As a result, it was possible to confirm that the heart rate signal detected in non-contact method through the finger vein image coincides with the waveform of actual heart rate signal.

A Study on the Sound Radiation from a Clamped Circular Plate with Viscoelastic layer by Impact Force (점성을 가진 음질이 입혀진 원형평판으로부터 의 음악복사)

  • Jeon, Jae-Jin;Lee, Byeong-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • 제6권3호
    • /
    • pp.5-16
    • /
    • 1987
  • In this paper, the sound radiation from a clamped circular plate with a viscoelastic layer excited by impact force is studied both analytically and experimentally. The composite plate vibrations are obtained by using the normal mode analysis and the eigenvalues are obtained by a Mindlin plate theory including the rotary inertia and shear deformation, The contact force developed between the ball and the plate with attached layers is obtained by Hertz contact theory. The radiated sound pressure is calculated by the Rayleigh integral. Prediction of the waveforms of sound radiating from the plate with attached layers and a method for reducing noise generation from the plate by impact force are also shown in this paper.

  • PDF

An 0.4nm Resolution Encoder-like Capacitive Displacement Sensor (0.4nm 해상도의 엔코더 타입 전기용량형 변위센서)

  • Kang, Dae-Sil;Kim, Moo-Jin;Moon, Won-Kyu
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1450-1454
    • /
    • 2007
  • A Contact-type Linear Encoder-like Capacitive Displacement Sensor (CLECDiS) has been developed to measure displacements at high accuracy within a long measurement range. In this paper, we have worked on improving the performance and reliability of the sensor. The performance increase can be done by introducing the smaller electrode patterns of $4{\mu}m$ width. In order to improve the reliability of the sensor we have changed the electrode layers from chrome-gold to chrome-gold-chrome and re-design its supporting structure. The newly-designed sensor is fabricated and tested to show that its sensitivity is $35pF/{\mu}m$, which implies that its resolution may be 0.36nm if SNR (Signal-to-Noise-Ratio) is 80.1dB. It is about ten times of that $(3.14pF/{\mu}m)$ of its previous version with 10${\mu}m$ electrodes. The total measurement range remains the same as the previous one; 15mm. The calibration experiments show its improved performance and reliability.

  • PDF

Implementation of Wireless ECG Measurement System Attaching in Chair for Ubiquitous Health Care Environment (유비쿼터스 헬스 케어 적용을 위한 의자 부착형 무선 심전도 측정 시스템 구현)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Jee-Chul;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제21권8호
    • /
    • pp.776-781
    • /
    • 2008
  • In this study, ubiquitous health care system attaching in chair to monitor ECG for health care was developed at the unconsciousness state. The system conveniently and simple measured ECG at non-consciousness. We measured the contact impedance to skin-electrode of metal mesh electrodes of the system. Contact impedance enable the electrode to use for ECG measurement. The results are that the impedance of the metal mesh electrodes according to sizes is low when the size is 4$cm^2$. As the result, when the size of the metal mesh electrode is 4$cm^2$, the electrode is fit for ECG measurement. We can acquired by positing the arm on the metal mesh electrode. The ECG signal was detected using a high-input-impedance bio-amplifier, and then passed filter circuitry. The measured signal transmitted to a PC through the bluetooth wireless communication and monitored. Data of the non-constrained ECG system attaching in chair is noise-data when comparing metal mesh electrode with the Ag/Agcl electrode but the data is significant to monitor ECG for check the body state.

Application of Flexible-Type Sintered Brake Pads (플렉서블 타입 소결 브레이크 패드의 적용 연구)

  • Kim, Soung-Kwon;Kim, Sang-Ho;Kwon, Seok-Jin;Lee, Hi-Sung
    • Tribology and Lubricants
    • /
    • 제27권1호
    • /
    • pp.19-24
    • /
    • 2011
  • Metallic sintered brake pads are often applied to mid/high speed train due to their high strength and thermal characteristics. Imbalance contact between discs and pads can greatly influence the life span, one sided wear, discs attack/crack and threat the safety of the train during operation. In this research, we analyzed pressure/temperature distribution between brake pads and disks. Analyzed data had been verified and modified to conduct further tests of flexible brake pads with small/full-scale dynamo test. Flexible brake pads were installed to high speed train to conduct further tests to identify the differences between rigid brake pads and flexible brake pads. In result, Flexible brake pads showed outstanding disk thermal stability, one sided wear, noise and wear rate than rigid brake pad.

A Study on the Temperature Distribution and Deformation of Case in Shrinkage Fit Process(I) - Temperature Monitoring and Heat Transfer Analysis Model - (열박음 공정이 케이스의 온도분포 및 변형에 미치는 영향(I) - 온도 계측 및 열전달 해석 모델 정립 -)

  • 장경복;조상명;강성수
    • Journal of Welding and Joining
    • /
    • 제19권4호
    • /
    • pp.384-390
    • /
    • 2001
  • There have been many problems due to deformation in industry field. Especially, it is severe in parts with small size and thin thickness and in products that must have excellent airtightness and anti-noise. The countermeasures for this deformation in field have mainly been dependent on the rule of trial and error by operator's experience because of productivities. Systematic study about this product with deformation is also insufficient that deformation is complex problem with shape, size, material of product, joining method and conditions, etc.. It is efficient to apply CAE technique without influence on productivity to this problem. There is, however much difference between the result analyzed by CAE and appearances in working field because of the insufficiency of communication between simulator and worker and of sensing data for boundary condition in analysis. In this study, to solve this deformation problem, we intend to make a simulation model that is adapted from working conditions by tuning and feedback between sensing data and simulation results. This paper include temperature monitoring and make a heat transfer model using sensing data in product as previous step for deformation analysis. The heat transfer analysis of shrinkage fit process is considerably difficult due to contact heat transfer between case and core. To solve this contact problem, gap element is used in present study.

  • PDF

Measurement of Carrier-to-Noise due to Sun Interference Effect on C-band for THAICOM 2 Down-link Station at Mung, Khon-kaen

  • A. Waisontia;K. Charouensuk;S.Noppanakeepong;Lee, N. laruji;N. Heammkorn;Y. Moriya
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.2043-2046
    • /
    • 2002
  • This paper studies on Sun interference effects or Sun outage effects on C-band satellite reception signal for THAICOM2. The THAICOM2 satellite is at 78.5 degree East 〔co-located with THAICOM3〕. The down link station was located in Khon-kaen, longitude 102.83 degree East and latitude 16.43 degree North. The antenna diameter is 4.6 meters for C-band downlink station. Total 9 times of sun interference events were occurred during summer and fall of 2001 and these about 53 minutes altogether. The Maximum CM degradation of the THAICOM2 system was around 11 dB. The Sun interference events of 53 minutes of one year are 0.0122 percents of the C-band contact time when 21 hours of contact time is used f3r broadcasting a day.

  • PDF

A Study on the Dynamic Analysis of Recliner Gear for Vehicle Power Seats (차량용 시트 리클라이너 기어의 동적 해석)

  • Kim, Sung-Yuk;Lee, Jung-Bin;Kim, Key-Sun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제16권6호
    • /
    • pp.15-20
    • /
    • 2017
  • This study analyzed the load change of the gear generated by the operation of the vehicle recliner through Finite Element Analysis. The basic model of the recliner used was a commercial product, and the effect of the seat frame was excluded. The load conditions applied to the recliner were set considering gravity, the mass of the seat's back frame, and the weight of a person. The operating mode was set to move the seat back from the vertical to the reclined position. As a result, it was found that the tooth bending amount of the gear rim and wheel increased from the cam rotation angle of 450 degrees, and a change in the contact ratio occurred. Furthermore, excessive torque fluctuations occurred in the ranges of 390 to 450 and 750 to 710 degrees. It was found that this occurred in the region of about 30 degrees before and after the point where the x-axis direction load is larger than the y-direction load. From this torque fluctuation it was determined to likely to cause chattering noise.