• Title/Summary/Keyword: Contact Noise

Search Result 613, Processing Time 0.033 seconds

Drive System of Battery Type Surgical Handpiece (배터리형 외과수술용 핸드피스 구동 시스템)

  • Kong, Tae-Woong;Park, Sang-Hoon;Yu, Jae-Sung;Lee, Byoung-Kuk;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.369-373
    • /
    • 2007
  • Battery type surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type.

  • PDF

Ohmic Resistance of AlGaAs/GaAs HBT at High Temperature (고온 특성을 위한 AlGaAs/GaAs HBT의 설계에 관한 연구)

  • 이준영;신훈법;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.366-370
    • /
    • 2002
  • GaAs has become a very popular material for the fabrication of high frequency, low noise and microwave power devices. GaAs devices are also well suited for high temperature operation because of the large band gap of this material. The standard GaAs technology and device structures have to be modified for stable operation at high temperature. In this paper, AlGaAs/GaAs HBT considering stable ohmic contact at high temperature as well as thermal effect such as self-heating effect are introduced. All the data obtained study will be used as input data for the simulator and the result will be compared with an analytical model available in this study,

  • PDF

An Inductive Position Sensor for Self-sensing Magnetic Suspension System (셀프센싱 자기 부상계를 위한 인덕턴스형 변위센서)

  • 윤형진;이상헌;백윤수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1038-1041
    • /
    • 2003
  • The magnetic suspension system is used in many areas, because it has great advantages. such as no friction, no noise, no lubrication and so on, but it is a unstable system in natural. It must have a feedback control with the position is measured for a stable levitation. There are an eddy-current sensor, a capacitive sensor, an inductive sensor, and an optical sensor with a laser as the sensor which measures displacements without contact. Among them, an inductive sensor is made with lower price than others. And it has a good linearity. In this paper, a magnetic circuit leads a linear equation between an input as a displacement and an output as a voltage. Experiments establish that voltage change according to displacement is linear. This paper presents the preliminary study of an inductive position sensing for self-sensing magnetic suspension system.

  • PDF

Gear Teeth Modification for a 2.5MW Wind Turbine Gearbox (2.5MW 풍력발전기 기어박스 치형수정)

  • Lee, Hyoung Woo;Kang, Dong-Kwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.109-117
    • /
    • 2014
  • This paper reports a method to modify the gear tooth profile of a wind turbine gearbox to reduce the noise caused by the impact of the gear teeth. The major causes of tooth impact are the elastic deformation of the gear teeth, shafts, and case of the gearbox under loading, and the fabrication tolerances in gear manufacturing. In this study, the tooth profile was modified considering the elastic deformation of the gear tooth and the tooth lead modification to compensate for tooth interference in the lead direction as a result of shaft deformations. The method was applied to the gearbox of a 2.5MW wind turbine, and the transmission error was characterized before and after modifying the gear teeth. For the modified gear teeth, the transmission error (67.6%) was lower by 17.8%. Additionally, the gear contact stress was reduced by 6.3%, to 22.3%.

Profile-shifted Gears in Multi-axial Differential System (다축차동장치의 전위기어 해석)

  • Kang, Dong-Soo;Song, Chul-Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.5
    • /
    • pp.632-637
    • /
    • 2011
  • A new tooth profile which is adjusted on the amount of addendum modification factor is proposed for reducing vibration and noise of gears. The transmission error of the new profile can be designed more uniformly than that of the standard involute profile. The basic concepts of tooth profile modification are to reduce the load in contact area and to find the appropriate profile modification factor for operation condition. In this study, gears were estimated to constructive safety of bending strength and contact strength durability by using ROMAX program, and were compared with results by design formula of AGMA standard.

Measurement Algorithm of Bi-directional Diameter in Ground Spindles Using Extended Kalman Filter (확장 칼만필터를 이용한 연삭스핀들 외경의 측정알고리즘)

  • Bae, Jong-Il;Bae, Min-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.468-473
    • /
    • 2017
  • This paper presents an in-process measurement system for shaft radius measurement during grinding process. This system does not require to stop the grinding process, which can enhance productivity and quality. In order to measure the radius, the system employs an eddy current sensor that can measure without any contact with the shaft. This type of sensor is very appropriate because it is insensitive to interference such as cutting fluid, coolant, contact pressure, and wear. For data analysis, the measurement system is modeled as a linearized discrete form where the states with noise are estimated by an extended Kalman filter. This system has been validated through simulations and experiments.

Development of Battery Type Powered Handpiece Drive System for Surgical Operation (Battery type 외과수술용 핸드피스 구동 드라이브 시스템)

  • Ha, Jung-Jun;Yoon, Yong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.388-394
    • /
    • 2008
  • The purpose of this paper is concerned with a battery type powered handpiece drive system for surgical operation. Battery type powered surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type. Also in this paper we develop the battery type power handpiece drive system for surgical operation using controller IC UC3625 of UNITRODE CO. Finally some experimental and simulation results are provided to demonstrate the validity of the proposed battery type power handpiece drive system.

Real-Time Measurement Technology for Bi-directional Diameter in Ground Spindle (연삭 스핀들류의 실시간 외경 측정기법)

  • Lee, Man-Hyung;Jung, Young-Il;Bae, Jong-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.136-144
    • /
    • 1999
  • This paper presents an in-process measurement system for shaft radius measurement during grinding process. This system does not require to stop the grinding process, which can enhance productivity and quality. In order to measure the radius, the system employs an eddy current sensor that can measure without any contact with the shaft. This type of sensor is very appropriate because it is insensitive to interference such as cutting fluid, coolant, contact pressure, and wear. For data analysis, the measurement system is modeled as a linearized discrete form where the states with noise are estimated by an extended Kalman filter. This system has been validated through simulations and experiments.

  • PDF

Dynamics and Control of 6-DOF Shaking Table with Bell Crank Structure

  • Jeon, Duek-Jae;Park, Sung-Ho;Park, Young-Jin;Park, Youn-Sik;Kim, Hyoung-Eui;Park, Jong-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.296-301
    • /
    • 2005
  • This paper describes the kinematics, dynamics and control of a 6-DOF shaking table with a bell crank structure, which converts the direction of reciprocating movements. In this shaking table, the bell crank mechanism is used to reduce the amount of space needed to install the shaking table and create horizontal displacement of the platform. In kinematics, joint design is performed using $Gr{\ddot{u}}bler's$ formula. The inverse kinematics of the shaking table is discussed. The derivation of the Jacobian matrix is presented to evaluate singularity conditions. Considering the maximum stroke of the hydraulic actuator, collision between links and singularity, workspace is computed. In dynamics, computations are based on the Newton-Euler formulation. To derive parallel algorithms, each of the contact forces is decomposed into one acting in the direction of the leg and the other acting in the plane orthogonal to the direction of the leg. Applying the Newton-Euler approach, the solution of inverse dynamics is almost completely parallel. Only one of the steps-the application of the Newton-Euler equations to the platform-must be performed on one single processor. Finally, the efficient control scheme is proposed for the tracking control of the motion platform.

  • PDF

Inversion of Resistivity Data using Data-weighting (자료 가중을 통한 전기비저항 탐사 자료의 역산)

  • Cho, In-Ky;Lee, Keun-Soo;Kim, Yeon-Jung;Yoon, Dae-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.1
    • /
    • pp.9-13
    • /
    • 2015
  • All the resistivity data contain various kinds of noise. The major sources of noise in DC resistivity measurement are high contact resistance, measurement errors, and sporadic background noise. Thus, it is required to measure data noise to accurately interpret resistivity data. Reciprocal measurements can provide a measure of data precision and noise. In this study, we proposed a data-weighting method from reciprocity measurement. Furthermore, a data-weighting method using both the reciprocity error and data-misfit in the inversion process was studied. Applying the data-weighting method to the inversion of 3D resistivity data, it was confirmed that local anomalies are slightly suppressed in the final inversion results.