• 제목/요약/키워드: Contact Noise

검색결과 613건 처리시간 0.023초

초소형 광디스크 드라이브용 관성 래치 설계 (Inertia Latch Design for Micro Optical Disk Drives)

  • 김경호;김유성;이승엽;유승헌;김수경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1157-1164
    • /
    • 2003
  • Dynamic Load/unload (L/UL) mechanism is an alternative to the contact start stop (CSS) technology which eliminates stiction and wear failure modes associated with CSS. Other benefits of L/UL include increased areal density due to smooth disk surfaces, thinner overcoats, and lower head flying height Improved shock resistance due to elimination of head slap, and reduced power consumption. Inertia latch mechanism becomes important for mobile disk drives because of non operating shock performance. Various types of latch designs have been introduced in hard disk drives to limit a rotary actuator from sudden uncontrolled motion. In this paper, a single spring inertia latch is introduced for a small form optical disk drive, which uses a rotary actuator for moving an optical pick-up. A new small inertia latch with single spring is designed to ensure both feasible and small size. The shock performance of the new inertia latch is experimentally verified.

  • PDF

향상된 스틱-슬립 마찰 모델을 이용한 스마트 구조물의 마이크로 위치제어 (Micro-positioning of a Smart Structure Using an Enhanced Stick-slip Model)

  • 이철희;장민규;최승복
    • 한국소음진동공학회논문집
    • /
    • 제18권11호
    • /
    • pp.1134-1142
    • /
    • 2008
  • In this paper, a model-based stick-slip compensation for the micro-positioning is proposed using an enhanced stick-slip model based on statistical rough surface contact model. The smart structure is comprised with PZT(lead (Pb) zirconia(Zr) Titanate(Ti)) based stack actuator incorporating with the PID(proportional-integral-derivative) control algorithm, mechanical displacement amplifier and positioning devices. For the stick-slip compensation, the elastic-plastic static friction model is used considering the elastic-plastic asperity contact in the rough surfaces statistically. Mathematical model of system for the positioning apparatus was derived from the dynamic behaviors of structural parts. PID feedback control algorithms with the developed stick-slip model as well as feedforward friction compensator are formulated for achieving the accurate positioning performance. Experimental results are provided to show the performances of friction control using the developed positioning apparatus.

초음파 물체부상 이송시스템의 Flexural Beam 설계 (Flexural Beam Design of Ultrasonic Object Levitation Slide System)

  • 정상화;김현욱;최석봉;김광호;박준호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.959-962
    • /
    • 2005
  • In the semiconductor and optical industry. a new transport system which can replace the conventional transport system is required. The Transport systems are driven by the magnetic field and conveyer belts. The magnetic field may damage semiconductor and the contact force may scratch the optical lens. The ultrasonic wave driven system can solve these problems. In this semiconductor and optical industry, the non-contact system is required for reducing the damages. The ultrasonic transportation is the solution of the problem. In this paper, the ultrasonic levitation system for levitation object are proposed. The 3D vibration profiles of the beam are measured by Laser Scanning Vibrometer for verifying the vibration characteristics of the system and the amplitudes of the beam and the levitation heights of object are measured fore evaluating the performance.

  • PDF

승용차 착석 자세에서의 인체 겉보기 질량 측정 및 고찰 (Measurement and Investigation of Apparent Masses of a Human Body at the Sitting Posture in a Passenger Car)

  • 장한기;홍석인;김기선;이정훈;김광준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.369-374
    • /
    • 2004
  • This study aims to measure an apparent mass of a seated human body at the sitting posture in a passenger car in the frequency range from 1 to 20 Hz and to investigate the dynamic characteristics. Thirty subjects joined the test where eight levels of acceleration from $0.1m/s^2\;to\;2.0m/s^2$ were used to excite seated human body. Most of apparent mass curves showed two peaks in the frequency range of $4\sim9Hz$, first peak was clearer at the contact point of the seat and the hip, and the second one at the contact point of the backrest and the back. Both peak frequencies were found to move down to lower frequencies with increase of acceleration magnitude. Shapes of apparent mass curves were clearly different from those at erect posture especially in the frequency range around and above the second peak.

  • PDF

양면에서 부분적으로 유체와 접하는 사각평판의 고유진동 (Free Vibration of a Rectangular Plate Partially in Contact with a Liquid at Both Sides)

  • 정경훈;이규만;김태완;박근배
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.123-130
    • /
    • 2008
  • An analytical method for the free vibration of a flexible rectangular plate in contact with water is developed by the Rayleigh-Ritz method. The plate clamped along the edges is partially contacted with water at both sides. It is assumed that the contained water is incompressible and inviscid. The wet mode shape of the plate is assumed as a combination of the dry mode shapes of a clamped beam. The liquid motion is described by using the liquid displacement potential and determined by using the compatibility conditions along the liquid interface with the plate. Minimizing the Rayleigh quotient based on the energy conservation gives an eigenvalue problem. It is found that the theoretical results can predict excellently the fluid-coupled natural frequencies comparing with the finite element analysis result.

구동중인 자동차 배기계의 진동 특성 측정 (Vibration Measurement of an Automobile Exhaust System in Operation)

  • 김성국;이종남;한순우;정태진;이신영;장강원
    • 한국소음진동공학회논문집
    • /
    • 제17권3호
    • /
    • pp.235-240
    • /
    • 2007
  • In this work, the operational deflection shape(ODS) of an automobile exhaust system is measured by using a recently-developed magnetic sensor. The magnetic sensor is composed of a solenoid and two pairs of permanent magnets generating an antisymmetric magnetic field in the lateral direction inside the solenoid. Lateral movement of a ferromagnetic pipe inside the magnetic field of the suggested sensor induces an electromotive force in the solenoid corresponding to the lateral velocity of the pipe. Due to the simplicity and non-contact characteristics of the magnetic sensor, dynamic behaviors of the structures operating under high temperature such as an exhaust pipe can be efficiently observed. It is shown that the lateral ODS of an exhaust system can be successfully measured by the suggested sensors.

제동시 발생하는 리어 드럼브레이크 Grunt(stick-slip) Noise 개선 (Rear Drum Brake Grunt(stick-slip) Noise Improvement on Braking During Nose-dive & Return Condition)

  • 홍일민;장명훈;김선호;최홍석
    • 한국소음진동공학회논문집
    • /
    • 제23권9호
    • /
    • pp.781-788
    • /
    • 2013
  • Grunt(stick-slip) noise happens between rear lining and drum on braking condition while vehicle is returning to steady position after nose-dive. The study presents a new testing and analysis methods for improving brake grunt noise on vehicle. Grunt noise is called a kind of stick slip noise with below 1 kHz frequency that is caused by the surfaces alternating between sticking to each other and sliding over each other with a corresponding change in friction force. This noise is typically come from that the static friction coefficient of surfaces is much higher than the kinetic friction coefficient. For the identification of the excitation mechanism and improvement of grunt noise, it is necessary to study variable parameters of rear drum brake systems on vehicle and to implement CAE analysis with stick slip model of drum brake. The aim of this study has been to find solution parameters throughout test result on vehicle and dynamo test. As a result of this study, it is generated from stick slip between rear lining and rear drum and it can be solved to reduce contact angle of lining with asymmetric and is effected not only brake drum strength but also rear brake size and brake factor.

제동시 발생하는 리어 드럼브레이크 grunt (stick-slip) noise 개선 (Rear drum brake grunt (stick-slip) noise improvement on braking during nose-dive & return condition)

  • 홍일민;장명훈;김선호;최홍석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.743-749
    • /
    • 2012
  • Grunt (Stick-slip) noise happens between rear lining and drum on braking condition while vehicle is returning to steady position after nose-dive. The study presents a new testing and analysis methods for improving brake grunt noise on vehicle. Grunt noise is called a kind of stick slip noise with below 1kHz frequency that is caused by the surfaces alternating between sticking to each other and sliding over each other with a corresponding change in friction force. This noise is typically come from that the static friction coefficient of surfaces is much higher than the kinetic friction coefficient. For the identification of the excitation mechanism and improvement of grunt noise, it is necessary to study variable parameters of rear drum brake systems on vehicle and to implement CAE analysis with stick slip model of drum brake. The aim of this study has been to find solution parameters throughout test result on vehicle and dynamo test. As a result of this study, it is generated from stick slip between rear lining and rear drum and it can be solved to reduce contact angle of lining with asymmetric and is effected not only brake drum strength but also rear brake size and brake factor.

  • PDF

레일 진동감쇄에 의한 소음방사 특성에 관한 연구 (A Study of Noise Radiation Characteristics by Rail Vibration Reduction)

  • 김진호;장동두;김희규
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2844-2850
    • /
    • 2015
  • 철도의 운행으로 인하여 발생하는 다양한 소음 중 큰 부분을 차지하고 있는 전동소음의 경우 차륜과 레일의 접촉에 의하여 진동과 이로 인한 소음방사가 발생하므로, 레일 진동에 대한 특성과 이로 인한 방사소음과의 상호연관성 및 특성의 파악이 필요하다. 본 연구에서는 레일의 유한요소 모델을 구성하고 경계요소법을 이용하여 진동으로 인해 발생하는 소음방사를 예측하였다. 입력으로는 레일에서의 진동속도 계측치를 이용하였고 소음방사 예측결과를 계측결과와 비교하여 해석기법의 신뢰성을 검증하였다. 또한 레일 감쇄 특성에 따른 소음방사 특성을 주파수 영역에서 검토하여 레일 댐핑재의 적용에 따라 약 3dB(A)의 방사소음 저감 효과가 있음을 확인하였다.

산업용 로봇 손목의 동력 전달계에 대한 동특성 해석 (Dynamic Analysis of the Power Transmission System in an Industrial Robot)

  • 김우형;정진태
    • 한국소음진동공학회논문집
    • /
    • 제18권9호
    • /
    • pp.913-919
    • /
    • 2008
  • Dynamic characteristics of a wrist power transmission of an industrial robot are studied. The wrist power transmission has complex structure characteristics, because it is composed with several shafts and gear system. We used an analytical method to investigate the dynamic characteristics. An analytical model is a rigid model which is composed with masses and springs. Both bearing and gear contact model represent equivalent stiffness springs which are determined by the experiment. In order to investigate the dynamic tendency of the robot wrist power transmission, we simulate the analytical model. There is a dynamic analysis tool which is called the RecurDyn. To verify the analytic results, we experiment a signal analysis which is an overall noise level of the robot. By the parametric study of the element of the robot, we study an improvement method of dynamic characteristics.