• 제목/요약/키워드: Contact Heat transfer Coefficient

검색결과 61건 처리시간 0.025초

온간단조 공정의 계면열전달계수 (Contact Heat Transfer Coefficient for Finite Element Analysis in Warm Forging Processes)

  • 강종훈;고병호;제진수;강성수
    • 소성∙가공
    • /
    • 제15권3호
    • /
    • pp.183-188
    • /
    • 2006
  • Heat transfer coefficients have great influence on finite element analysis results in elevated temperature forging processes. Experimentally calculated contact heat transfer coefficient is not suitable for one-time finite element analysis because analyzed temperature will be appeared to be too low. To get contact heat transfer coefficient for one-time finite element analysis, tool temperature in operation was measured with thermocouple and repeated finite element analysis was performed with experimentally calculated contact and cooling heat transfer coefficient. Surface temperature of active tool was obtained comparing measurement and analysis results. Contact heat transfer coefficient for one-time finite element analysis was achieved analyzing surface temperature between repeated finite element analysis and one-time finite element analysis results.

핀관 열교환기에서 확관율이 접촉열전달계수에 미치는 영향 (Effect of Expansion Ratio on Contact Heat Transfer Coefficient in Fin-Tube Heat Exchanger)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.45-50
    • /
    • 2012
  • The plate fin and tube type of heat exchanger is widely used in air conditioner, and the heat exchanger is assembled by the mechanical expansion of copper tubes and fastening the aluminum fin. The objective of the present study is to investigate how the mechanical expansion of copper tube affects on the heat transfer performance of a plate fin and tube type heat exchanger. This study has been performed by experimental and numerical methods. The numerical and experimental results show that the tube expansion ratio has a influence on the heat transfer performance. Within the tested expansion ratio, the contact pressure shows the peak value and it decreases as the expansion ratio increases. Air-side heat transfer coefficient increases until the expansion ratio reaches 1.23, and then decreases with the similar pattern to the contact pressure. Also, contact heat transfer coefficient shows the maximum when the contact pressure is highest as well as the air-side heat transfer coefficient.

Micro-Channel형 열교환기에 부착된 핀의 열접촉저항이 열전달 특성에 미치는 영향 (Effect of Thermal Contact Resistence on the Heat Transfer Characteristics of Air Flow around the Finned Micro-Channel Tube for MF Evaporator)

  • 박용석;성홍석;성동민;서정세
    • 한국기계가공학회지
    • /
    • 제20권11호
    • /
    • pp.121-126
    • /
    • 2021
  • In this study, the effect of thermal contact resistance between pin-channel tubes on the heat transfer characteristics was analytically examined around the channel tubes with the pins attached to two consecutive arranged channel pipes. The numerical results showed that the heat transfer coefficient decreased geometrically as the thermal contact resistance increased, and the corresponding temperature change on the contact surface increased as the thermal contact resistance increased. The thinner the pin, the more pronounced the geometric drop in the heat transfer coefficient. It was confirmed that the higher the height of the pin, the higher was the heat transfer coefficient, however, the greater the size of the thermal contact resistance, the smaller was the heat transfer coefficient. It was found that the temperature change in the inner wall of the channel tube did not significantly affect the heat transfer characteristics owing to the thermal contact resistance. Furthermore, the velocity of air at the entrance of the channel tube was proportional to the heat transfer coefficient due to a decrease in the convective heat resistance corresponding to an increase in the flow rate.

온간 단조 공정에서의 열전달 계수 (Heat transfer coefficients for F.E analysis in warm forging processes)

  • 강종훈;고병호;제진수;강성수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.138-143
    • /
    • 2005
  • Finite Element analysis is widely applied to elevated temperature forging processes and shows a lot of information of plastic deformation such as strain, stress, defects, damages and temperature distributions. In highly elevated temperature deformation processes, temperature of material and tool have significant influence on tool life, deformation conditions and productivities. To predict temperature related properties accurately, adequate coefficients of not only contact heat transfer between material and dies but also convection heat transfer due to coolants are required. In most F.E analysis, too higher value of contact heat transfer coefficient is usually applied to get acceptable temperature distribution of tool. For contact heat transfer coefficients between die and workpiece, accurate values were evaluated with different pressure and lubricants conditions. But convection heat transfer coefficients have not been investigated for forging lubricants. In this research, convection heat transfer coefficients for cooling by emulsion lubricants are suggested by experiment and Inverse method. To verify acquired convection and contact heat transfer coefficients, tool temperature was measured for the comparison between measured tool temperature and analysis results. To increase analysis accuracy, repeated analysis scheme was applied till temperature of the tool got to be in the steady-state conditions. Verification of heat transfer coefficients both contact and convection heat transfer coefficients was proven with good accordance between measurement and analysis.

  • PDF

The Effect of Non-condensable Gas on Direct Contact Condensation of Steam/Air Mixture

  • Lee, Hanchoon;Kim, Moohwan;Park, Suki
    • Nuclear Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.585-595
    • /
    • 2001
  • A series of experiments have been carried out to investigate the effects of non-condensable gas on the direct contact film condensation of vapor mixture under an adiabatic wall condition. The average heat transfer coefficient of the direct contact condensation was obtained at the atmospheric pressure with four main parameters ; air-mass fraction, mixture velocity, film Reynolds number, and the degree of water film subcooling having an influence on the condensation heat transfer coefficient. With the analysis of 88 experiments, a correlation of the average Nusselt number for direct contact film condensation of steam/air mixture at an adiabatic vertical wall was proposed as functions of film Reynolds number, mixture Reynolds number, air mass fraction, and Jacob number. The average heat transfer coefficient for steam/air mixture condensation decreased significantly while air mass fraction increased. The average heat transfer coefficients also decreased as the Jacob number increased, and were scarcely affected by the film Reynolds number below a mixture Reynolds number of about 245,000.

  • PDF

접촉 열저항을 고려한 합금주조의 응고과정 해석 (An analysis on the solidification process of alloy casting with a contact resistance)

  • 김우승;이관수;임익태;김광선
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.57-67
    • /
    • 1997
  • The solidification process of Al 4.5%Cu alloy is numerically studied in the presence of contact resistance between mold and cast. Natural convection is considered in the liquid and mushy regions. The porosity approach is applied to the mushy zone modeling and linear variation of the solid fraction on the temperature is assumed. Results show that the mushy region is wider in the case with a contact resistance compared to the perfect contact condition. The temperature of the cast with a temporal variation in the contact heat transfer coefficient changes very rapidly in the early stage of the casting process compared to that with constant contact heat transfer coefficient.

직접접촉식 액화천연가스 기화기의 특성에 관한 연구 (A Study on Characteristics of Direct Contact LNG Evaporator)

  • 한승탁;김종보
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.903-911
    • /
    • 1994
  • This study addresses the phenomena of bubbling, icing, eruption, component varieties of the evaporated natural gas, and volumetric heat transfer coefficients obtained during the operation of a proposed LNG evaporator between LNG and water in direct contact. In the present investigation, the explosive and eruption phenomena within the water column were not observed during the entire operation of the heat exchanger. Compared with the natural gas produced by conventional LNG evaporator, the analysis of the gas produced by the direct contact LNG evaporator shows that nitrogen, methane, and ethane components were reduced by 0.002~0.007mol%(4~14%), 1.6~1.92mol%(1.9~2.3%) and 0.17~1.28mol%(1.1~8.4%) respectively, while the moisture content was rather increased by 0.51~0.76mol%. The maximum volumetric heat transfer coefficient of the direct contact heat exchanger was found to be $21, 800kW/m^3\cdotK$.

직접접촉식 열교환기내에서 물과 배기가스의 직접접촉에 의한 열 및 물질전달 (Heat and Mass Transfer between Hot Waste Gas and Cold Water in a Direct Contact Heat Exchanger)

  • 이금배
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1171-1178
    • /
    • 1992
  • 본 연구에서는 직접접촉식 열교환기를 이용한 실험을 통하여 열교환기 설계에 가장 중요한 열교환기 단위 체적당 총괄 열전달 계수를 시스템의 작동조건에 따라 구 하여 실제 설계자료로 이용하는 데 그 목적이 있다.

용탕단조시 가압력에 따른 계면열전달계수의 변화 (Effect of Pressure on Interfacial Heat Transfer Coefficient in the Squeeze Casting Process)

  • 김진수;안재영;한요섭;이호인;홍준표
    • 한국주조공학회지
    • /
    • 제14권3호
    • /
    • pp.248-257
    • /
    • 1994
  • Research in heat transfer and solidification commonly involves experimentation and mathematical modeling with associated numerical analysis and computation. Inverse problems in heat transfer are part of this paradigm. During the solidification of metal casting, an interfacial heat transfer resistance exists at the boundary between the casting and the mold, and this heat transfer resistance usually varies with time. In the case of the squeeze casting the contact heat transfer resistance is decreased by pressure and ideal contact is almost accomplished. In the present work, heat transfer coefficient, which is inverse value of the heat transfer resistance, was used for convenience. A numerical technique, Non-Linear Estimation has been adopted for calculation of the casting/mold interfacial heat transfer coefficient during the squeeze casting process. In this method, the measured temperature data from experiment were used. The computational results were applied to the analysis of heat transfer and solidification.

  • PDF

확관을 고려한 불균일 내면가공관의 전열특성 (Heat Transfer Characteristics of the Non-Uniform Grooved Tube Considering Tube Expansion)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.553-559
    • /
    • 2012
  • A plate-fin heat exchanger is a type of heat exchanger widely used in air conditioners, and tubes and fins are tightly assembled by the mechanical expansion process of tubes. The tube expansion process deforms the grooves inside the tube, and the groove shapes also affect the adhesion between tubes and fins. In this study, the adhesion and heat transfer performance affected by the tube expansion of the non-uniform groove shape tube with different heights are investigated by both analysis and experiments. From the analysis method, it was shown that the contact pressure of non-uniform groove tube is higher than that of the uniform groove tube, and the most appropriate high groove number of the non-uniform groove tube is designed for the maximum contact pressure. From the experimental results, the decreasing rate of the condensation heat transfer coefficient is smaller in the non-uniform groove tube with different heights, compared to the conventional uniform groove tube. Also, the air-side heat transfer coefficient of the non-uniform groove tube with different heights is higher than that of the uniform groove tubes.