• Title/Summary/Keyword: Contact Ability

Search Result 313, Processing Time 0.027 seconds

CYTOTOXICITY OF RETROGRADE FILLING MATERIALS TESTED BY 51Cr RELEASE, MIT AND LD ACTIVITY (51Cr방출과 MTT 및 LD활성도를 이용한 역충전재의 세포독성에 관한 연구)

  • Choi, La-Young;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.409-428
    • /
    • 1994
  • Endodontic surgery is performed when conventional endodontic therapy fails or is contraindicated. In such cases, retrograde filling materials including amalgam, composite resin, and various cements have been used. Biocompatibilty and margin sealing ability of retrograde filling materials are important for the long term success of endodontic surgery. In vitro cell culture is frequently used as the method of measuring the biocompatibilty of dental materials. The purpose of this study was to evaluate the cytotoxicity of six kinds of retrograde filling materials including newly developed light curing glass ionomer cements. Each material was mixed according to. the manufacture's instruction and evaluated as : freshly mixed, 24-hour after mixing, and 168-hour after mixing respectively. The elution solution was extracted after 24-hour contact with materials using media. Cytotoxicity was evaluated by direct contact, or elution contact. Test results of radiochromium($^{51}Cr$) release, cell viability using tetrazolium dye (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl dimethyltetrazolium bromide(MTT) test and lactate dehydrogenase(LD) of damaged L929 cells were analyzed. In the $^{51}Cr$ release of direct contact, all experimental retrograde filling materials except amalgam and glass ionomer cement showed increased cytotoxicity compared to control. In the $^{51}Cr$ release of elution solution, the released $^{51}Cr$ was so minimal that it was impossible. to evlauate the cytotoxicity exactly. The elution solutions of glass ionomer cement and IRM showed marked cytotoxicity in MTT test. LD enzyme activity was highest in tests of direct contact with composite, light curing composite, and light curing glass ionomer cement and IRM. Amalgam revealed least cytotoxicity while IRM showed cytotoxicity using all three methods. Composite, light curing composite and light curing glass iomomer cement were cytotoxic in the tests of $^{51}Cr$ release and LD activity. Glass ionomer cement showed cytotoxic effect only in the MTT method. From these results it is suggested that the standardization and optimization of cytotoxicity testing, especially using elution solutions, should be strongly advised.

  • PDF

Kinematical Analysis of Men's Pole Vault Event (장대높이뛰기 경기의 운동학적 분석)

  • Lim, Kyu-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.15-26
    • /
    • 2003
  • This study was conducted to investigate the performance times, CM position and CM speed, pole chord length and pole chord angle, whole body angular momentum(X axis), and grip width in pole vault event according to the event and phase; touch down, pole plant, take-off, maximum pole bending pole straight, pole release, peak height, and foot contact, pole contact, free flight. The pole vaulting of four male elite vaulters including six trial were filmed using two video digital cameras at 60 Hz at 56th national athletic match, and data were collected through the DLT method of three dimensional cinematography. In general the better jumper is, the longer the performance time is. And the greater CM speed is, and the better his transformation ability of CM horizontal speed into vertical speed is. As he uses a longer pole, his grip is higher, and it is a enough for him to rock back his body, so that he pulls and pushes the pole well keeping his hips close to. An greater maximum angular momentum and early positioning of the hips parallel to the bar makes his body far side of the bar and his bar clearance easier. Specially our national jumper needs to have more powerful braking force during foot contact phase, and take his body on the pole after maximum pole bending, and pull and push the pole strongly keeping his hips close to. Also he needs to have stronger muscular strength in order to control the longer pole and use the pole of proper tension more efficiently.

Evaluation of the Integrity of TIG Welding Using Non-Contact SH-EMAT (비접촉 SH-EMAT을 이용한 TIG용접부 건전성 평가)

  • Park, Tae Sung;Park, Yeong Hwan;Park, Ik Keun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.1
    • /
    • pp.48-53
    • /
    • 2016
  • An EMAT can be used to reliably detect defects as it serves as a non-contact transducer with the ability to transmit ultrasonic waves into specimens without couplant. Moreover, an EMAT can easily generate desired waves by altering the design of the coil and magnet. This study proposes an SH-EMAT to evaluate the integrity of the TIG welding part. A stainless steel was welded using the TIG welding method. The welding current was varied to create artificial defects. Both the PA-UT and the RT were applied to verify the defect size. The experimental results generated by using the EMAT were compared with those methods. The amplitude was observed to decrease with an increase in the defect size. These results confirmed that the presence of defects can be reliably detected by attenuation of signal amplitude. The results demonstrated that the proposed method is suitable for evaluating the integrity of TIG welding.

Teflon coating of fabric filters for enhancement of high temperature durability (섬유상 여과필터의 고온 내구성 향상을 위한 테프론 코팅 연구)

  • Kim, Eun-Joo;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.232-239
    • /
    • 2011
  • Fabric fibrous filter has been used in various industrial applications owing to the low cost and wide generality. However, the basic properties of fabric materials often limit the practical utilization including hot gas cleaning. This study attempts to find new coatings of porous fibrous filter media in order to overcome its insufficient thermal resistance and durability. Teflon was one of the plausible chemicals to supplement the vulnerability against frequent external thermal impacts. A foaming agent composed of Teflon and some organic additives was tentatively coated on the glass fiber mat. The present test Teflon foam coated filter was fount to be useful for hot gas cleaning, up to $250^{\circ}C$-$300^{\circ}C$. Close examination using XPS(X-ray Photoelectron Spectroscopy) and Contact angle proved the binding interactions between carbon and fluorine, which implies coating stability. The PTFE/Glass foam coated filter consisted of more than 95% (C-F)n bond, and showed super-hydrophobic with good-oleophobic characteristics. The contact angle of liquid droplets on the filter surface enabled to find the filter wet-ability against liquid water or oil.

The Heating of Cu-oxide and Arc Properties according to Electrical Poor Contact (전기적 불완전 접촉에 따른 동산화물의 발열 및 아크 특성)

  • Kim, Wansu;Park, SangJune;Hwang, DongHyun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.15-20
    • /
    • 2019
  • As industry is progressing and standards of living are improved, the demand of electrical energy is expected to grow 8-9% annually. Therefore, the importance of electrical fire prevention technology with the ability of the power supply is being emphasized. According to the statistics of fire in Korea, fire occurred about 45,000 cases annually, and electrical fire possessed about 20%. The electrical fire by poor contact has increased gradually, can be connected as great fire to secondarily induce short circuit and earth fault. Then analysis of heating causes of electrical connections between copper and copper alloy is needed. Also, detection and analysis algorithm of oxide at copper alloy are necessary. In this research, in order to understand the characteristics of oxide growth with rising resistance and heating, it is demonstrated that the oxide at electrical connections can cause fire due to arcing.

Development of Self-Driven Pneumatic Robot for Boresonic Examination of Turbine Rotor (터빈로터 중심공 검사용 자기주행 공압형 로봇 개발)

  • Kang, Baejun;An, Myungjae;Lee, Chul-Hee
    • Journal of Drive and Control
    • /
    • v.18 no.1
    • /
    • pp.31-38
    • /
    • 2021
  • This study presents a new principle for driving the robot aimed at reducing the position error for the boresonic examination of turbine rotor. The conventional method of inspection is performed by installing manipulator onto the flange of the turbine rotor and connecting a pipe, which is then being pushed into the bore. The longer the pipe gets, the greater sagging and distortion appear, making it difficult for the ultrasonic sensor to contact with the internal surface of the bore. A pneumatic pressure will ensure the front or rear feet of the robot in close contact with the inner wall to prevent slipping, while the ball screw on the body of the robot will rotate to drive it in the axial direction. The compression force required for tight contact was calculated in the form of a three-point support, and a static structural simulation analysis was performed by designing and modeling the robot mechanism. The driving performance and ultrasonic detection ability have been tested by fabricating the robot, the test piece for ultrasonic calibration and the transparent mock-up for robot demonstration. The tests have confirmed that no slipping occurs at a certain pneumatic pressure or over.

Non-contact Heart Rate Monitoring using IR-UWB Radar and Lomb-Scargle Periodogram (IR-UWB 레이더와 Lomb-Scargle Periodogram을 이용한 비접촉 심박 탐지)

  • Byun, Sang-Seon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.1
    • /
    • pp.25-32
    • /
    • 2022
  • IR-UWB radar has been regarded as the most promising technology for non-contact respiration and heartbeat monitoring because of its ability of detecting slight motion even in submillimeter range. Measuring heart rate is most challenging since the chest movement by heartbeat is quite subtle and easily interfered with by a random body motion or background noise. Additionally, periodic sampling can be limited by the performance of computer that handles the radar signals. In this paper, we deploy Lomb-Scargle periodogram method that estimates heart rate even with irregularly sampled data and uneven signal amplitude. Lomb-Scargle periodogram is known as a method for finding periodicity in irregularly-sampled and noisy data set. We also implement a motion detection scheme in order to make the heart rate estimation pause when a random motion is detected. Our scheme is implemented using Novelda's X4M03 radar development kit and its corresponding drivers and Python packages. Experimental results show that the estimation with Lomb-Scargle periodogram yield more accurate heart rate than the method of measuring peak-to-peak distance.

The Effect of Visual Stimulation on Gait Parameters During Backward Walking in Healthy Individuals (정상인의 후방 보행 시 시각 자극이 보행 변수에 미치는 영향)

  • Han-Byeol Sung;Ji-won Seo;Jung-Hyun Cho;Young-Keun Woo
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.91-99
    • /
    • 2024
  • Purpose: Backward walking has shown positive effects on gait recovery in rehabilitation patients. It is increasingly used as an aerobic training method in rehabilitation populations, inducing more sensory and motor stimulation than forward walking. Therefore, the purpose of this study is to investigate the effects of visual stimulation during backward walking. Methods: Twenty-seven healthy adults with a visual acuity of 0.8 or higher participated in the study. To compare the effects of visual stimulation during various walking conditions among healthy individuals, the participants randomly selected cards numbered one to six and walked a distance of 10 meters. Walking ability was measured using Optogait. Results: Statistically significant differences were observed in speed, stride, and percentages of single support and contact phase during backward walking. Within eyes-closed conditions during backward walking, significant differences were found in percentages of single support, terminal stance, and contact phase. Moreover, the percentage of terminal swing significantly differed during backward walking with head turn conditions. Conclusion: Gait parameters such as speed, stride, and percentages of single support and contact phase were higher during backward walking than forward walking. These results indicate that backward walking involves multiple sensory systems and varying conditions.

Photoimmunological and Photobiological Action of Infrared Radiation

  • Danno, Kiichiro
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.194-196
    • /
    • 2002
  • While ultraviolet radiation alters various cutaneous cell functions, little is known about photo-immunological and photobiological effects of infrared radiation (IR) on the skin except its local thermal effects. The fIrst part of this study demonstrated that single exposure of mouse skin to near IR (0.7 - 1.3 $\mu$m) reversibly suppressed the proliferating activity of the epidermis, the density of Langerhans cells, and the ability of skin to induce contact hypersensitivity reaction. The second part demonstrated that the rate of wound closure was significantly accelerated by repeated exposures in animal models. The production of transforming growth factor-$\beta$l and matrix metalloproteinase-2, which are responsible for the wound healing processes, was significantly upregulated by irradiation, as shown by enzyme immunoassay, zymography, and reverse transcription polymerase chain reaction. Thermal controls were negative. The results suggest that near-IR irradiation can modulate the epidermal proliferation and part of the skin immune system, and stimulate the wound healing processes, presumably by non-thermal effects.

  • PDF

Three-Dimensional Finite Element Analysis of a Vacuum Interrupter (진공 인터럽터의 3차원 유한요소해석)

  • Choi, Seung-Kil;Kang, Hyung-Boo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.10
    • /
    • pp.693-698
    • /
    • 1999
  • Vacuum interrupters have a special asymmetric electrode structure to generate an magnetic field and consequently to increase the interrupting ability. Accordingly 2-dimensional analysis has a large analysis error because radial flux can not be considered. In this paper, in order to analyse the electric field distribution of a vacuum interrupter with arc shield more accurately, 3-dimensional finite element method(FEM) is used. The induced electric potentials of floating shield was increased with the gap distance, which is because the relative position of shield is closer to the fixed contact so that the capacitance distribution inside interrupter is varied. The calculated results also show that the induced potential of shield causes electric field distortion so that the maximum value of electric field in a vacuum interrupter with arc shield is higher than that without one.

  • PDF