• Title/Summary/Keyword: Construction level

Search Result 4,375, Processing Time 0.028 seconds

A Study on the Sound Insulation Performance Elevation of Floor Structure that use Rubber chip in Apartment House (고무칩을 이용한 공동주택 바닥구조의 차음성능 향상에 관한 연구)

  • 박명길;함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.237-332
    • /
    • 2002
  • We constructed ceiling structure and floor structure for elevation of sound insulation performance of concrete slab of apartment house. And, we wished to measure heavy floor impact sound level and light floor impact sound level of these structure. As the result, light floor impact sound level interception performance of concrete slab was measured by thing that construction work of gypsum baud is important. Heavy floor impact sound level interception performance was measured by thing that it is effective that construct to thickness about 30 millimeters on concrete Slav. It was measured effectively that heavy floor impact sound level interception performance constructs rubber chip to thickness about 30 millimeters on concrete Slav.

  • PDF

A Study on the Relationship between Needs and Clothing Interest (의상흥미와 욕구와의 상관연구 - 여자대학생을 중심으로 -)

  • 정하신
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.4
    • /
    • pp.23-31
    • /
    • 1982
  • 1. The Purpose of this study is (1) to analyze college women's clothing Interest. (2) to find out the relationship between Needs and Clothing Interest Field. 2. Results (1) Clothing Interest of Fashion and Shopping Field was highest in score. (2) The relationship between Needs and Clothing Interest field was as follows. (a) Clothing Interest of Construction correlated significantly with abasement, dominance, and sex atp<.05, and with achievement, affiliation, and emotionality at p<.01 level. (b) Clothing Interest of Design & Fashion correlated significantly with achievement, affiliation, aggression, dominance, emotionality, exhibitionism, sex, and autonomy at p<.01 level. (c) Clothing Interest of Shopping correlated significantly with emotionality at p<.05, and with affiliation, exhibitionism, sex, aggression, dominance, and achievement at p<.01 level. (d) Clothing Interest of Management correlated significantly with affiliation, achievement, and emotionality at p<.01, and with dominance at p<.05 level. (e) Clothing Interest of Pscho. Aspect. correlated significantly with abasement at p<.05, and with achievement, affiliation, aggression, dominance, emotionality, exhibitionism, and sex at p<.01 level.

  • PDF

Composition and Use of Biosafety Level 3 Facility (생물안전 3등급 연구시설의 구성 및 이용)

  • Kim, Changhwan;Hur, Gyeunghaeng;Lee, Wangeol;Jung, Seongtae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.335-342
    • /
    • 2015
  • Laboratory facilities for biology are designed as biosafety level 1, biosafety level 2, biosafety level 3, and biosafety level 4. Biosafety level designations are based on a composite of the design features, construction, containment facilities, equipment, practice and operation procedures required for working with agents from the various risk groups. Generally, biosafety level 3 means the facility that is appropriate for the experiments using pathogens which can cause serious diseases by aerosol transmission. The biosafety level assigned for the specific work to be done is driven by professional judgement based on a risk assessment, rather than by automatic assignment according to the particular risk group designation of the pathogenic agents to be used. In this paper, we introduced the biosafety level 3 facility operated in ADD(Agency for defense development). It contains the overview of facility, microbiological experiment, animal experiment, decontamination and waste disposal. Biosafety level 3 laboratory in ADD has served the vital role in the research of biological agents and antidote development.

A Study on the Performance of Noise Level and Airflow Amount of a Kitchen Hood by the Different Conditions of Airflow Path. (레인지후드 덕트설치 조건에 따른 소음 및 풍량특성 연구)

  • Kim, Il-Ho;Kim, Youn-Jae;Lee, Yong-Jun;Lee, Kyu-Dong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.11-14
    • /
    • 2007
  • Noise level and Airflow amount of a kitchen hood are affected by the conditions of airflow path. Thus this study is expected to be used as a basic reference in designing airflow path of apartment housing throughout analysing changes in noise level and airflow amount from the various conditions of airflow path. Noise level generated by the kitchen hood is estimated in a kitchen and a living room of two constructed apartment houses, and an experiment is conducted in an half anechoic chamber to analyze noise level and airflow amount by the different length, diameter and number of windings of a round shaped soft duct which is connected to the kitchen hood. The measured results in apartment houses show that the noise level in both apartments exceeds the NC standard greatly in living spaces. In apartment A, a regular apartment house, the noise level was $NC-65{\sim}75$, $NC-45{\sim}60$ and NC-70, NC-45 in the kitchen and living room with an operation of kitchen hood in 1 and 3 stages. In apartment B, an apartment complex, the noise level was NC-55 and NC-60 in the kitchen and living room with an operation of kitchen hood in 3 stages. In particular, there was an increase of noise level at 125Hz-band resulted from an amplification of sound, which requires adequate measures in noise reduction. The results measured in Half anechoic chamber show 99% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 100mm to ${\Phi}$ 125mm, 37% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 125mm to ${\Phi}$ 150mm, and 173% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ l00mm to ${\Phi}$ 150mm. The noise level was lower than the level measured in apartment housing about 20 in NC-value and 11.4 in dB(A)-value, which was interpreted as the effect of the load by the pressure condition at the rear end of the duct. Also, an amplification of sound in 125Hz-band influenced NC-value considerably, therefore effective measure is needed.

  • PDF

Evaluation of the Impact on Surrounding Groundwater of Waterway Tunnel Excavation and Cofferdam Construction (터널 굴착 및 가물막이 시공에 따른 주변 지하수계 유동분석)

  • You, Youngkwon;Lim, Heuidae;Choi, Jaiwon;Eom, Sungill
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.6
    • /
    • pp.5-15
    • /
    • 2014
  • This study is to quantitatively evaluate the impact on surrounding groundwater of waterway tunnel excavation and cofferdam construction in which A-dam and B-dam, so prediction of groundwater fluctuation and tunnel lining installation was studied. As a result, drawdown of groundwater level during tunnel excavation and cofferdam construction occurred about 3.58 m in the tunnel shaft. The initial condition of groundwater level recovered by up to 90 % was simulated after the completed the construction of the tunnel and lining installation. Groundwater inflow in the tunnel evaluated was analyzed to have exceeding water design criteria of the tunnel. The groundwater inflow is reduced to maximum $0.006m^3/min/km$ after lining installation done in the tunnel, so effect of lining installation was evaluated as 93 % or more. Drawdown of about 0.04~0.31 m occurs in the houses and temples analysis of groundwater system of the surrounding area from construction. Drawdown has occurred nearly by considering annual groundwater level fluctuation of National Groundwater Observation Network.

The Effect of Conflict Over Construction of Private University Dormitories on Licensed Real Estate Brokerage (사립대학 기숙사 건립 갈등이 공인중개업에 미치는 영향)

  • Lee, YunHong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.6
    • /
    • pp.34-43
    • /
    • 2021
  • While universities are making every effort to improve the housing welfare of university students by establishing new dormitories, the construction of school dormitories has intensified the conflict with other certified real estate businesses on the basis of their right to survival. Thus, it is necessary to analyze the causality in the conflict to coherently understand the conflict between these stakeholders. To do so, this study conducted a survey questionnaire on certified real estate businesses in the vicinity of private universities with dormitories in the metropolitan area. This study targeted licensed real estate brokerage agencies that conclude rental contracts in view of different stances, and control the real estate rental market by controling their conflict. Investigated the influence relationship between universities and licensed real estate brokerage agencies in relation to construction of private university dormitories and the effect of this conflict on management performance of licensed real estate brokerage agencies, and analyzed the relationship among relevant variables to see if their dormitory recognitions have a moderating effect. In addition to analyzing the causality of conflict level (perceived conflict, expressed conflict), conflict management, conflict outcome, and management performance, the study also verified the moderating effect of perception on dormitory and the mediating effect of conflict management. The results showed that conflict level had a negative (-) effect on conflict management, while the perceived conflict and conflict management of the conflict level had a negative (-) effect on the conflict outcome. In the relationship between perceived conflict and conflict outcome, conflict management had a complete mediating effect while expressed conflict had a partial mediating effect. Lastly, the perception of university dormitories did not have a moderating effect for the influence of conflict management on conflict outcome.

Intellectual Asset Measurement of Construction Corporation's Knowledge Management (건설기업 지식경영의 지적자산 측정)

  • Son Young-Chan;Baik Jong-Keon;Kim Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.3 no.3 s.11
    • /
    • pp.94-102
    • /
    • 2002
  • It expresses well result measurement system's the importance that 'It can not manage that can not measure.' In this way, there is no expressivity that express difficulty. While Corporation's tangible asset is possible measuring by specific amount of money of financial statement or loss and gain statement etc, Method of corporation's intangible asset measurement is much had been introduced, but some one is not presenting objective frame. This research did size of construction corporation's intangible Asset(Intellectual Asset) through knowledge asset storing accumulation model(XYZ model) that present in LG economy research institute so that do quantification objectively. Through this, can presume construction corporation's intrinsic value level.

The Direction of Information System Construction for Infrastructure Maintenance & Management (시설물 유지관리의 정보시스템 구축방향)

  • Kim Tae-Hak;Kim Nam-Gon;Ju Ki-Bum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.474-477
    • /
    • 2002
  • Information technology has affected various industries, and the construction industry is one of those. In construction industry, the operating body for maintenance is trying to implement more systematic management skill for public facilities in order to minimize the life cycle cost. For more efficient maintenance system, first, the target facilities were selected and the present condition of their systems was estimated. And, the implementation plan of new system was proposed based on them. Accordingly, the new system managed by working-level personnel can supplement the weak points in the current system.

  • PDF

An Analytical and Experimental Study on the Mechanical Behavior of Excavating Turnels beneath the Roadway (공용중 도로하부의 굴착터널 해석 및 계측 연구)

  • Chung, Kuang-Mo;Bang, Myung-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.99-104
    • /
    • 2012
  • A turnelling work beneath roadways or railways in use is unsafe and dangerous. A turnelling method should be analytically and experimentally studied to verify stability and safety of excavating works by construction step. The conventionally analytical method was ineffective in computational time and cost, so the new analytical method named homogenuity method, was developed and verified compared with analytical results. That method was applied to parameterly study the effect of distance of steel supports and overburdening height of soil. It showed that the homogenuity method was very practical and effective in step-by-step analysis considering construction sequences. A measuring device was set at the construction field and mechanical behavior was monitored during construction. Measuring values are larger than analytical values because impact of inserting steel pipes, lowering level of underground water and vibration of passing vehicles affected soil density during construction, but those values were within allowable limits.

Effect of Anchorage on Strength of Precast R/C Beam-Column Joints

  • Kim, Kwangyeon
    • Architectural research
    • /
    • v.2 no.1
    • /
    • pp.55-60
    • /
    • 2000
  • Recently, there is a great demand for precast reinforced concrete (RC) construction methods on the purpose of simplicity in construction. Nishimatsu Construction Company has developed a construction method with precast reinforced concrete members in medium-rise building. In this construction method, how to joint precast members, especially the anchorage of the main bar of beam, is important problem. In this study, the structural performance of exterior joints with precast members was investigated. The parameters of the test specimens are anchorage type of the main bar of beam (U-shape anchorage or anchorage plate) and the ratio of the column axial force to the column strength. Specimens J-3 and J-4 used U-shape anchorage and the ratio of the column axial force of specimen J-4 was higher. On the other hand, specimens J-5 and J-6 used anchorage plate, and the anchorage lengths are 15d and 18d, respectively. Experimental results are summarized as follows; 1) For the joints with beam flexural failure mode, it was found that the maximum strength of specimen with anchorage plate is equal to or larger than that of specimen with conventional U-shaped anchorage if the anchorage length of more than 15d would be ensured, 2) Each specimen shows stable hysteretic curves and there were no notable effects on the hysteretic characteristics and the maximum strength caused by the anchorage method of beam main bar and the difference of column axial stress level.

  • PDF