• Title/Summary/Keyword: Construction facility

Search Result 1,626, Processing Time 0.026 seconds

A Folkloric Demonstration on 'Sam-gama' The Field Report on the Construction, Structure and Utilization of 'Sam-gama' ('삼가마' 유구에 대한 민속학적논증 '삼가마'(삼굿)의 축조와 구조, 운용에 대한 현지조사 보고)

  • Lim, Hyoung Jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.4
    • /
    • pp.4-19
    • /
    • 2009
  • Though admitting that, in light of the recent archaeological trend, the excavation on relics of Sam-gama (a sort of kiln steaming the hemp) is increasingly reported, little efforts by far have been made not only to restore its traditional structure design but also to research hardly the change of hemp-steaming technologies in ages. In this regard, this paper shows the exploration of structural method and design as well as operability with regard to Sam-gut, traditional hemp-processing equipment that was recently reconstructed in Jungsun, Kangwon Province. Samgut, generally positioned at the waterside area, is an traditional device for steaming hemp to get bast fibers from the raw material of hemp, principally consisting of HWA-JIP(fire-place) to obtain steams by feeding fire ad Mong-got(boiling chamber) to make the hemp steamed after stacking. More specifically, thick round-logs were piled at the bottom of Hwajip prior to stacking stones around its circumferential area. When the timber positioned below gets burned with high temperature to heat stones existing in the upper side, waters then poured onto it after laying a bundle of grass and soil up to the boiled stones. If so, there generates hot vapor, which is conveyed to Monggot to steam the hemp. Functionally, it is of outstanding importance that Samgut is capable of producing high-temperature water vapors instantaneously under the intensive manpower, thus being constructed achievable for those purposes. The Samgut made by digging the ground is an instant facility that is closed after use. The remains, which were used to generate higher thermal power for steaming hemp, make it hard to excavate the historic traits because there left little vestiges in the soil, which means keen attention must be paid to find out the trace of Smgama relics. Future research stall be focused on collection of broader data regarding Samgut including technological review in extracting bas fibers from the hemp.

Evaluation of the Pull-out Resistance of the SMA Wire Connector (SMA 와이어를 이용한 연결재의 인발저항성능 평가)

  • Jung, Chi-Young;Woo, Tae-Ryeon;Lee, Jong-Han;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • Precast concrete (PC) structure is one of the type of the structures which is made in a facility prior to installing it to a construction field. The contact surfaces between two PC structures should be treated for obtaining enough binding force by inducing prestressing force. However, in the many cases, the contact surface causes the crack and leakage of water. These cracks and water leakage can cause the corrosion of the rebar, and the corrosion of the rebar can severely reduce the long-term durability. In this study, the SMA wire connector is suggested to solve the problem with the contact surfaces between two PC structures. The pull-out resistance of the suggested SMA wire connector is evaluated by conducting the tests to find the effect of the number of wires, shape of connector part, and shape memory effect. As a result of this study, the empirical formula is suggested to estimate the pull-out resistance related with the effects of the shape of the connector, shape memory effect, and the adhesive force. The validity between the estimated pull-out resistance and the measured value is confirmed.

Introduction to Current Status and Researches for Rock Engineering of Finnish Geological Disposal of Spent Fuel (핀란드의 사용후핵연료 지층처분 현황 및 암반공학 관련 연구소개)

  • Hong, Suyeon;Kwon, Saeha;Min, Ki-Bok;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.29 no.4
    • /
    • pp.215-229
    • /
    • 2019
  • This technical note describes the current status of Finnish radioactive waste disposal project which started to construct the repository for spent nuclear waste for the first time in the world. Finland started operating nuclear power plant in 1977 and is currently operating four nuclear power plants. After detailed site surveys started in 1993, Olkiluoto was finally selected by the parliament of Finland as the site for geological disposal in 2001 followed by a construction license in 2015. If the operating license is approved by the government in the 2020s, it would be the world's first case of geological disposal. In ONKALO, a site-specific underground research facility at the site of Olkiluoto, various studies were conducted to verify the safety of the repository. Finland uses the KBS-3 disposal concept, and Korea considers a similar disposal concept because of similar rock formations. The entire process in Finland including the operation status of intermediate and low-level waste disposal, site investigation and selection stages, and the latest rock mechanics and hydrogeological studies in ONKALO are presented. Suggestions for the radioactive waste disposal in Korea is given based on the Finnish case.

Restoration of The Transportation Network between North and South Korea for Mt. Geumgang Tourism (금강산(내금강) 관광을 위한 남북연결 교통망에 관한 연구)

  • HONG, Gil-Jong;BAE, Sun-Hak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.51-64
    • /
    • 2019
  • Mt. Geumgang has been a scenic spot representing the Korean peninsula since the Joseon Dynasty, and became a symbol of inter-Korean exchanges with the Gaesong Industrial Complex after the division of the South and North. Mt. Geumgang Tour Course is divided into the Inner-Geumgang (Naegeumgang) and the Outer-Geumgang (Oegeumgang). It was common for the Mt. Geumgang tour route during the Joseon Dynasty and the Japanese Imperialization period to enter the Inner-Geumgang, near Seoul, and come to the East Sea through the Outer-Geumgang. However, the tour route starting from Goseong was utilized for the Mt. Geumgang tour course operated by Hyundai. Because North Korea opened only the Outer-Geumgang area. North Korea has only opened some of its tour courses to Hyundai, but if Geumgang tourism is resumed in the future, there is a high possibility that it will be opened further, such as opening some sections of the Inner-Geumgang in 2007. In this case, it is necessary to connect additional transportation networks to access Inner-Geumgang from South Korea. The best alternative was the restoration of the Mt. Geumgang Railway. However, considering the fact that the reconstruction of the Mt. Geumgang Railway can not be completed due to the construction of the Imnam Dam, it is the most realistic alternative to restore Route 31 connecting Yanggu and Geumgang-eup. As a result of the analysis of road connecting Inner-Geumgang, three routes were confirmed. All of which were adjacent to the existing National Route 31. These routes passing through Dutayeon and Mundeung-ri and joining the Route 31 from Inje. Considering road length, topography characteristics, and military facility layout, it seems that the connection of 'Dutaeyun - Mundeung - Geumgang' is a realistic alternative connecting from South Korea to Inner-Geumgang.

The Characteristics of Flexibility applied to Unit Plan of Housing by Residents Participation - focusing on European Multi-story Housing applying Residents Participation - (거주자 참여형 공동주거의 평면계획에 적용된 가변성의 특성 - 유럽의 거주자 참여형 다층 공동주거를 중심으로 -)

  • Kim, Hyun-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.113-123
    • /
    • 2018
  • First of all, the multi-story Housing applying resident's participation in europe was classified by the menu selection method, the two-step supply method and the cooperative method. And then I analyzed flexible unit plan of cases for deriving the planning methode and the characteristics of flexibility. First, I analyzed the area and form of the unit plan, structure and Installation, fixed and variable elements to derive the planning method. The area of units are distributed from a minimum of $35m^2$ to a maximum of $150m^2$, and many of the unit planes have a narrow front and a deep depth. The structure is a long-span wall-structure or a skeleton structure, and is designed without any columns and bearing walls in the interior space for flexibility in spatial composition. The vertical shafts are located in the center of the unit in a box-form or in the corner at the unit dividing wall for free placement of interior wall. Fixed elements are framework and facility systems. Most of the future residents in the two-steps supply method and the cooperative method were able to freely design the internal space within the zoning concept proposed by the architect and change the location of the facade element within module system proposed by the architect. Second, the characteristics of the flexibility applied to the unit plan were divided in integrated flexibility, functional flexibility, construction flexibility, and supply flexibility. The integrated flexibility enables residents to give the variable space combination based on the complex structure of the inner space for providing various living experiences. Regarding functional flexibility, the three-dimensional spatial structure with neutral space has multi-functionality according to the needs of residents and easily accepts mixing of hybrid programs such as work and residence. Constructive flexibility allows residents to create identity by freely planning interior space and changing the size or location of facade components in a determined system of architects. Finally, various types of size and space composition are proposed and realized in the whole building applying menu selection method, so that flexibility in the offer can accommodate and integrate various types of living.

A new Direction for the Preliminary Feasibility Study of Public Healthcare Facilities (공공의료시설 예비타당성조사 방법론 개선 방향에 관한 연구)

  • KIM, MIN JAE
    • Journal of the Korean Regional Science Association
    • /
    • v.37 no.1
    • /
    • pp.3-14
    • /
    • 2021
  • Due to COVID-19, the importance of public medical facilities, especially hospitals specializing in infectious diseases, is rising. Despite the government's strong will, the establishment of public medical facilities and infectious disease hospitals has not been properly established. This is because the overall system related to the construction of public medical facilities does not sufficiently reflect social and economic changes and the trend of the times. The purpose of this study is to derive limitations and problems related to the guidelines for preliminary feasibility studies of public medical facilities and to present alternatives. This study proposes 'Option Value' as an alternative. Since the option value is a willingness to pay for an uncertain situation, it is theoretically reasonable and reasonable to reflect it as an additional benefit. Normally, the value of existence is not seen, but the system that is seen in a crisis is in the 'medical and health'. Therefore, it is necessary to find a system that is invisible even in the feasibility evaluation in the medical and health, and constantly improve and develop a methodology that can estimate changes in the welfare of citizens within the system. I expect this study to play a role as a catalyst.

Design and Implementation of Modbus Communications for Smart Factory PLC Data Collection (스마트팩토리 PLC 데이터 수집을 위한 Modbus 통신 설계 및 구현)

  • Han, Jin-Seok;Yoo, Jae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.4
    • /
    • pp.77-87
    • /
    • 2021
  • Smart Factory refers to a factory that can be controlled by itself with an intelligent factory that improves productivity, quality and customer satisfaction by combining the entire process of manufacturing and production with digital automation solutions. The manufacturing industry around the world is rapidly changing, with Germany, Europe, and the United States at the center. In order to cope with such changes, the Korean government is also implementing a policy to spread the supply of smart factories for small and medium-sized companies, and related ministries and agencies such as the Ministry of Commerce, Industry and Energy, the Ministry of SMEs and Venture Business, the Korea Institute of Technology and Information Promotion, and local technoparks, as well as large companies such as Samsung, SK and LG are actively investing in smart manufacturing projects to support smart factories[1]. Factory Automation (FA) construction has many issues regarding the connection of heterogeneous equipment. The most difficult aspect of configuring various communications from various equipment is the reason. Although it may not be known if there are standards or products made up of the same company, it is not easy to build equipment that is old, up-to-date, and different use environments through a series of communications. To solve this problem, we would like to propose a method of communication using Modbus, one of FieldBus, which is one of the many industrial devices of PLC, a representative facility control system, and is used as a communication standard.

Analysis of Ultimate Rockfall Energy Resistance of CFT Rock Shed Main Frame (CFT 피암터널 주구조체의 극한 낙석에너지 저항능력 분석)

  • Moon, Jiho;Lee, Juho;Song, Jong-Keol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.3
    • /
    • pp.129-135
    • /
    • 2021
  • Rock sheds are a type of rockfall protection facility that is installed on the road near steep slopes, where large amount of rockfall is expected. Rock sheds are generally designed to resist approximately 200 kJ to 3,000 kJ of rockfall energy. In a previous study, a new type rock shed structure having a concrete-filled tube (CFT) main frame was proposed. By using CFT as the main frame in a rock shed, rapid construction is possible. Additionally, high load carrying capacity and ductility can be achieved. The behavior of the proposed rock shed structure was studied via elastic analysis with the equivalent static load of rockfall energy as in a previous study. However, it is necessary to investigate the behavior of the proposed rock shed in more detail with a full 3D finite element (FE) model considering realistic rockfall load. The FE model for the CFT rock shed main frame was developed first in this study. Then, the resistance of the CFT rock shed main frame Under ultimate rockfall energy was investigated.

A Statistical Analysis of Results of Detailed Inspections on Aged Concrete Erosion Control Dams in Gyeongsangbuk-do (경상북도 지역 노후 콘크리트사방댐 정밀점검 결과의 통계적 분석)

  • Kim, Jeongsig;Kim, Dongyeob
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.2
    • /
    • pp.276-286
    • /
    • 2022
  • We carried out this study to provide basic data necessary to establish a management plan for concrete erosion control dams in the future by analyzing results of detailed inspections of aged dams conducted in accordance with 「Guidelines for the Maintenance of the Erosion Control Facility」. We analyzed the results of a detailed inspection of 54 concrete erosion control dams which had been built over 20 years previously, located in private forests of Gyeongsangbuk-do using statistical methods. Having conducted exterior defect investigations, we found 18 dams (33.4%) in need of repair or follow-up measures and 15 dams in which the overall grade was changed due to investigator's corrections; we therefore considered that standardization of related standards and indicators would be necessary. After conducting concrete compression strength tests, we found 19 dams (35.2%) to be below the standard value of 21 MPa, and in particular, we included, in grade A, eight dams which we judged to be in good condition as a result of the exterior defect inspection. There was little clear correlation between the total score and the compressive strength of concrete, but there was a statistically significant difference in the compressive strength by overall grade. After analyzing the changes in the characteristics of the erosion control dams according to the elapsed years after construction, we detected no particular trend in the changes of total score and compressive strength over time. However, the cumulative ratio of the dams that required repair and follow-up measures and the dams below the compression strength standard had a strong positive linear relationship over time, suggesting that it would be possible to identify the aging characteristics of concrete erosion control dams.

GIS Macro Evaluation System for Urban Walk - Focusing on Busan - (도심 보행을 위한 GIS 거시 평가체계 개발 - 부산을 중심으로 -)

  • Yu, Yeon seo;Kim, Jong gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.581-590
    • /
    • 2022
  • It is important to create a decent pedestrian space in order to realize a public space that can ultimately improve the quality of life based on guaranteeing people's right to move while also enhancing urban activity. The goal of this study is to develop a pedestrian path evaluation system in order to lay the foundation for data construction leading to the creation of such elegant walking space. First, a basic system was established in keeping with factors and the space, and this system was used as the basic framework of the study. The trends identified in the literature can be divided into eight categories, denoted here as: Walking safety policy, Walking focused plan, Recognition transition, Transportaion system, Activity-linked walking, Facility utilization walking, Nature and history linked walking and Content convergence walking. The macro- and micro-indices and factors mentioned in related studies were synthesized and classified, and the basis for universality and differentiation was established by integrating them. Next, according to the basic composition of the walking system, Walking potential and slope safety in the Safety category, Basic walking connectivity and Traffic linkage in the Efficiency category, Walking arrangement and Rest convenience in the Health category, and Resource connectivity and Activity abundance in the Comfortability category macro evaluation system of the eight categories were established and a corresponding measurement method was developed.