• Title/Summary/Keyword: Construction disaster

Search Result 1,484, Processing Time 0.026 seconds

A Study on Effectiveness for Car-Crash Fires Prevention through a Full-length Speed Enforcement System in Highway Tunnels (고속도로 터널내 차량추돌화재사고를 방지하기 위한 구간과속단속시스템 설치에 관한 통계적 연구)

  • Lee, Young-Jae;Kim, Gab-Cheol;Park, Hyung-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.119-127
    • /
    • 2011
  • Because of most notably the increase in vehicular traffic in Korea, as measured by highway transport usage, relief is being sought by expanding the construction of highways after 1970s'. These highways have opened up over 70 % of the mountainous areas in Korea's country side which includes the construction of tunnels. Currently there are 607 tunnels installed that are being maintained and by 2015, under the next medium-term plan, Korea will build an additional 440 tunnels. In addition, the use of 1,000m double-pole tunnels is expected to increase significantly in 256 locations. There is no doubt that these tunnels will relieve traffic congestion and aid improved communications, but halfclosed underground highway tunnels in particular are required to reduce tunnel fires caused by poor vehicle maintenance, and other factors such as speeding motorists that increase the number of vehicular accidents. Double-pole tunnels in 1,000m length over require vehicle drivers to be more cautious in terms of the continuous speed limit, judged by how devastating most of car-crash fires within these tunnels can be. In order to prevent these disasters, a full-length tunnel speed enforcement system should be considered mandatorily in legal clauses.

3D Track Models Generation and Applications Based on LiDAR Data for Railway Route Management (철도노선관리에서의 LIDAR 데이터 기반의 3차원 궤적 모델 생성 및 적용)

  • Yeon, Sang-Ho;Lee, Young-Dae
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1099-1104
    • /
    • 2007
  • The visual implementation of 3-dimensional national environment is focused by the requirement and importance in the fields such as, national development plan, telecommunication facility deployment plan, railway construction, construction engineering, spatial city development, safety and disaster prevention engineering. The currently used DEM system using contour lines, which embodies national geographic information based on the 2-D digital maps and facility information has limitation in implementation in reproducing the 3-D spatial city. Moreover, this method often neglects the altitude of the rail way infrastructure which has narrow width and long length. There it is needed to apply laser measurement technique in the spatial target object to obtain accuracy. Currently, the LiDAR data which combines the laser measurement skill and GPS has been introduced to obtain high resolution accuracy in the altitude measurement. In this paper, we first investigate the LiDAR based researches in advanced foreign countries, then we propose data a generation scheme and an algorithm for the optimal manage and synthesis of railway facility system in our 3-D spatial terrain information. For this object, LiDAR based height data transformed to DEM, and the realtime unification of the vector via digital image mapping and raster via exactness evaluation is transformed to make it possible to trace the model of generated 3-dimensional railway model with long distance for 3D tract model generation.

  • PDF

Estimation of Slime Thickness of Bored Piles by Using Borehole Electrical Resistivity Method (시추공 전기비저항 기법을 활용한 현장타설말뚝의 슬라임층 두께 평가)

  • Chun, Ok-Hyun;Lee, Jong-Sub;Park, Min-Chul;Bae, Sung-Gyu;Yoon, Hyung-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.3
    • /
    • pp.51-60
    • /
    • 2013
  • The slime, deposited in the bored pile due to falling soil particle, reduces the bearing capacity of bored pile and thus the stability of construction also decreases. The weight pendulum and iron have been used for estimating the slime thickness based on the subjective judgment and thus the previous method has a limitation of reliability. The objective of this paper is to suggest the method for estimating the slime thickness by using characteristics of electrical resistivity as scientific method. The temperature-compensation resistivity probe (TRP), which has a conical shape and the diameter of 35.7mm, is applied to the measurement of the electrical resistivity in the borehole during penetration. The field tests are carried out for estimating the slime thickness in the application site of bored pile. The slime thickness is calculated through the difference between excavation depth of borehole and measured data. Furthermore, the laboratory tests are also conducted for investigating effects of casing, time elapsing and relative density by using the specimen of slime. The laboratory test supporting the suggested method is reasonable for determining the slime depth. The paper suggests that the electrical resistivity method may be a useful method for detecting slime thickness and the method is expected to be applicable to various sites of bored piles.

Face to Face with the Past: Memorizing the Plague of Athens through the Exhibition (과거와의 대면 : ${\ll}$미르티스${\gg}$ 전시를 통해 기억된 아테네 대 역병)

  • Cho, Eun-Jung
    • The Journal of Art Theory & Practice
    • /
    • no.14
    • /
    • pp.7-32
    • /
    • 2012
  • The exhibition was started in 2010 in the New Acropolis Museum of Athens and embarked a journey since 2011 as a travelling exhibition inside Greece and abroad. The main purpose of the exhibition was to draw attention of the general public to the value of the 'rescue excavation' and of cultural heritage of Greece, by presenting the reconstruction bust of a girl whose skull was found in Kerameikos cemetery of ancient Athens. The new Kerameikos excavation was initiated by the construction of Metropolitan Railway lines in the center of Athens between 1992 to 1998. It revealed a pit of a mass burial where about 150 people were inhumed in a very hasty way without proper funeral rites or offerings. These bodies are identified as the victims of the infamous plague of Athens in the first years of the Peloponnesian War(430-426 BC). The epidemic disease killed almost one third of the city population including Pericles, and brought extreme fear and panic to the Athens society. The traditional funerary rites were totally disrupted, and the social decorum and the morality among the citizens became enfeebled. The plague and the civil war were the decisive factors to end the Golden Age of Democratic Athens. However, the exhibition organizers did not focus on the tragic aspect of this disaster and its casualties. Their main concern was to simplify the scholarly works of archaeological excavation and microchemistry analysis so that the exhibition viewers will easily understand and empathize the living value of the scholarly works of ancient Greek civilization. The centripetal element of the exhibition was the vivid face of an 11 years old ancient girl 'Myrtis', which was carefully reconstructed based on both the scientific data and artistic imagination. Also the set up of the exhibition was structured in order to stimuli cognitive and emotional experience of the visitors who witnessed the rebirth of a vibrant human being from an ancient debris. The museologists' continuous efforts to promote projects of contemporary artists, publications, and school programs related to the exhibition indicate that the ulterior motive of this exhibition is the cultural education of the present and future generation through the intimate experiences of ancient Greek life. Also this is the reason why the various museums that held the travelling exhibition try to make the presentation as a gesture of memorial service for an anonymous Athenian girl who deceased circa 2400 years ago. The pragmatic efforts of Greek scholars and museologists through exhibition show us a way to find a solution to the continuous threat of cultural resources by massive construction projects and land development, and to overcome public indifference to the history and cultural heritage.

  • PDF

Characteristics study on fire-resistant paint used by TGA-IR (TGA-IR을 사용한 내화 도료의 특성에 관한 연구)

  • Cho, Nam-Wook;Shin, Hyun-Jun;Cho, Won-Bo;Lee, Seong-Hun;Rie, Dong-Ho;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.168-172
    • /
    • 2011
  • The iron frame of building could be collapsed or bent at $500^{\circ}C$. Therefore the fire-resistant paint should be applied for safety. This study performed the comparative analysis to show the characteristics of fireresistant paint. And then 12 products of fire resistant paint and 6 products of paints were used as samples. And the samples were analyzed by TGA (Thermogravimetric Analyzer) as analyzer for measuring the variation of weight on temper of weight by heating. When TGA analyzer could measure the variatiature, and FT-IR was measured for analyze gas components on variation on of weight by heating on 12 products of fire resistance, the samples showed to decrease 40% of weight to $800^{\circ}C$, and because paints had 50% to 40% of loss weight, it showed to be equal with loss weight of fire resistance paint on high temperature or was lower loss weight than it of fire resistance paints. However number 6 sample of fire resistance paints could show to decrease 20% of total weight on $800^{\circ}C$. And then in the case of FT-IR, fire resistance paints could show to have the high intensity of $CO_2$ spectrum as complete combustion. However paints could show to have the lower intensity of $CO_2$ spectrum, have the higher intensity of water spectrum. Therefore the TGA graph of result could be much different until $250^{\circ}C$. When it was burned, FT-IR spectrum could show to confirm the characteristics of fire resistance paints, and the characteristic could be confirmed on inorganic paint of fire resistance by weight loss of TGA.

Technological Development Trends for Underground Safety in Urban Construction (도심지 공사시 지하안전 확보를 위한 기술개발 동향)

  • Baek, Yong;Kim, Woo Seok
    • Tunnel and Underground Space
    • /
    • v.27 no.6
    • /
    • pp.343-350
    • /
    • 2017
  • Amid increasingly saturated ground space, development of underground space has been booming throughout the world and excavation has been underway near the structure above or under the ground level. But the ground subsidence caused by improper or poor construction technologies, underground water leakage, sudden changes of stratum and the problem with earth retaining system component has been emerged as hot social issue. To deal with such problems nationwide, establishment of preventive and proactive disaster management and rapid restoration system has been pushed now. In this study, collection of the data on technology development trend to secure the underground safety was made, taking into account of internal change elements (changing groundwater level, damage to underground utilities, etc) and external change elements (vehicle load, earthquake and ground excavation, etc) during excavation. Amid the growing need of ground behavior analysis, ground subsidence evaluation technology, safe excavation to prevent ground subsidence and reinforcement technology, improvement of rapid restoration technology in preparation for ground subsidence and development of independent capability, this study is intended to introduce the technology development in a bid to prevent the ground subsidence during excavation. It's categorized into prediction/evaluation technology, complex detect technology, waterproof reinforcement technology, rapid restoration technology and excavation technology which, in part, has been in process now.

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 1. Robustness Assessment of Structural Alternatives for the Problem of Urban Floods (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 1. 도시 홍수 문제 구조적 대안의 내구성 평가)

  • Lee, Changmin;Jung, Jihyeun;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.2
    • /
    • pp.117-125
    • /
    • 2016
  • Current cities encounter various types of water problems due to rapid urbanization and climate change. The increasing significance of urban water problems calls for the establishment of resilient alternatives to prevent and minimize social loss that results from these phenomena. As a background research for establishing resilient infrastructures for the mitigation of urban water problems, we evaluated the robustness of structural alternatives for urban flood as a representative case. Combining the robustness index (RI) and the cost index (CI), we suggested the robustness-cost index (RCI) as an indicator of the robustness of structural alternatives, and applied the index to assess the existing infrastructures and structural alternatives (i.e., sewer network expansion, additional storage tank construction, and green roof construction) at a site prone to floods located around Gangnam-station, Seoul, Korea. At a rainfall intensity frequency range of 2 to 20 years, the usage of a storage tank and a green roof showed relatively high RCI value, with a variation of an alternative showing greater RCI between the two depending on the size of design rainfall. For a rainfall intensity frequency of 30 years, installing a storage tank with some green roofing was the most resilient alternative based on the RCI value. We proposed strategies for establishing resilient infrastructures for the mitigation of urban floods by evaluating the robustness of existing infrastructures and selecting optimal structural alternatives with the consideration of scales of design disaster.

Evaluation of the Actual Conditions for the Construction of a Firefighting Safety Management System in Domestic Power Plants (국내발전소 소방안전경영시스템구축을 위한 실태평가에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-wook
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.89-98
    • /
    • 2018
  • Fire accidents in foreign countries, like the accident in a thermal power plant in Beijing, the accidents in domestic power plants, including Boryeong Power Plant in 2012 and Taean Power Plant in 2016, a disaster in a nuclear power plant in Fukushima in 2011 or the large-scale power failure in California in 2001 are safety accidents related to electric power, which caused losses in the people's stable lives and the countries. Electricity has an absolute impact on the people's life and the economy, so we can easily expect the serious situation affecting economic growth as well as direct damage to the protection of the people's lives and the losses of properties, if there are fire or explosion accidents or radioactive leak because of negligence in safety management, or problems because of natural disasters like an earthquake in power plants that generate electricity. In this study, it was drawn the improvement of the organizations exclusively in charge of firefighting, the operation of a program for the improvement of professional competency, the development of a customized firefighting management system for plants for systematic firefighting safety management and the improvement of the earthquake-proof correspondence system, which has recently become an issue, as measures for improvements through a survey of the actual conditions concerning the necessity of the construction of a firefighting safety management system for power plants with five power generation companies, including Korea Southern Power Co., Ltd., and the persons in charge of firefighting safety Korea Hydro & Nuclear Power Co., Ltd.

Sensitivity analysis of pump and tank sizes on water network operation and water age (송수펌프용량 및 배수지규모에 따른 송·배수시스템의 운영비용 및 체류시간 분석)

  • Kim, Kangmin;Choi, Jeongwook;Jung, Donghwi;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.803-813
    • /
    • 2017
  • Recently, various studies have been conducted to optimize the pump operation scheduling and/or the pump/tank size minimizing the system cost of water distribution network. Prior to that, it is important to understand the sensitivity of pump/tank size on the system cost and overall water quality. Here, we have performed the sensitivity analysis to investigate the effect of pump/tank size on the economic cost (construction and operation) and water quality (water age). The analysis was applied on a real, large-scale water transmission network currently operating in South Korea. The results revealed that the pump/tank size has a strong influence on system construction/operation costs. Especially, the tank size has a significant effect on the system-wide water quality. In the case of applied networks, the operating cost decreases as the capacity of the facility increases, but the design cost increases. Using a sensitivity analysis, a suitable range of pump/tank size could be suggested to minimize costs and stabilize the water quality at the same time prior to a system design.

Estimating of the Greenhouse Gas Mitigation and Function of Water Resources Conservation through Conservation of Surface Soils Erosion and Policy Suggestion (표토유실 보전을 통한 온실가스배출 저감과 수자원 보전 기능의 산출 및 정책제안)

  • Oh, Seung-Min;Kim, Hyuck Soo;Lee, Sang-Pil;Lee, Jong Geon;Jeong, Seok Soon;Lim, Kyung Jae;Kim, Sung-Chul;Park, Youn Shik;Lee, Giha;Hwang, Sang-Il;Yang, Jae-E
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.6
    • /
    • pp.74-84
    • /
    • 2017
  • Soil erosion is often extreme in Korea due to high rainfall intensities and steep slopes, and climate change has also increased the risk of erosion. Despite its significane, erosion-induced soil organic carbon (SOC) emission and water resource loss are not well understood, along with the lack of an integrated surface soil erosion protection policy. Therefore, to design adequate protection policies, land users, scientists, engineers and decision makers need proper information about surface soil and watershed properties related to greenhouse gas emission potential and water conservation capability, respectively. Assuming the total soil erosion of $346Tg\;yr^{-1}$, soil organic matter (SOM) content of 2% (58% of SOM is SOC), and mineralization rate of 20% of the displaced carbon, erosion-induced carbon emission could reach $800Gg\;C\;yr^{-1}$. Also the available water capacity of the soil was estimated to be 15.8 billion tons, which was 14 times higher than the yearly water supply demand in Seoul, Korea. Therefore, in order to prevent of soil erosion, this study proposes a three-stage plan for surface soil erosion prevention: 1) classification of soil erosion risk and scoring of surface soil quality, 2) selection of priority areas for conservation and best management practices (BMP), and 3) application of BMP and post management.