• Title/Summary/Keyword: Construction Noise

Search Result 1,089, Processing Time 0.025 seconds

Hybrid Integration of P-Wave Velocity and Resistivity for High-Quality Investigation of In Situ Shear-Wave Velocities at Urban Areas (도심지 지반 전단파속도 탐사를 위한 P-파 속도와 전기비저항의 이종 결합)

  • Joh, Sung-Ho;Kim, Bong-Chan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.45-51
    • /
    • 2010
  • In urban area, design and construction of civil engineering structures such as subway tunnel, underground space and deep excavation is impeded by unreliable site investigation. Variety of embedded objects, electric noises and traffic vibrations degrades the quality of site investigation, whatever the site-investigation technique would be. In this research, a preliminary research was performed to develop a dedicated site investigation technique for urban geotechnical sites, which can overcome the limitations of urban sites. HiRAS (Hybrid Integration of Surface Waves and Resistivity) technique which is the first outcome of the preliminary research was proposed in this paper. The technique combines surface wave as well as electrical resistivity. CapSASW method for surface-wave technique and PDC-R technique for electrical resistivity survey were incorporated to develop HiRAS technique. CapSASW method is a good method for evaluating material stiffness and PDC-R technique is a reliable method for determination of underground stratification even in a site with electrical noise. For the inversion analysis of HiRAS techniuqe, a site-specific relationship between stress-wave velocity and resistivity was employed. As for outgrowth of this research, the 2-D distribution of Poisson's ratio could be also determined.

Development of Video-Detection Integration Algorithm on Vehicle Tracking (트래킹 기반 영상검지 통합 알고리즘 개발)

  • Oh, Jutaek;Min, Junyoung;Hu, Byungdo;Hwang, Bohee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5D
    • /
    • pp.635-644
    • /
    • 2009
  • Image processing technique in the outdoor environment is very sensitive, and it tends to lose a lot of accuracy when it rapidly changes by outdoor environment. Therefore, in order to calculate accurate traffic information using the traffic monitoring system, we must resolve removing shadow in transition time, Distortion by the vehicle headlights at night, noise of rain, snow, and fog, and occlusion. In the research, we developed a system to calibrate the amount of traffic, speed, and time occupancy by using image processing technique in a variety of outdoor environments change. This system were tested under outdoor environments at the Gonjiam test site, which is managed by Korea Institute of Construction Technology (www.kict.re.kr) for testing performance. We evaluated the performance of traffic information, volume counts, speed, and occupancy time, with 4 lanes (2 lanes are upstream and the rests are downstream) from the 16th to 18th December, 2008. The evaluation method performed as based on the standard data is a radar detection compared to calculated data using image processing technique. The System evaluation results showed that the amount of traffic, speed, and time occupancy in period (day, night, sunrise, sunset) are approximately 92-97% accuracy when these data compared to the standard data.

A Study on the PM10 and CO2 Concentrations at Public Places (일부 실내공간에서 PM10과 CO2의 농도 특성에 관한 연구)

  • Jung, Joon-sig;Park, Duckshin;Kim, Jong bum;Song, Hyea-suk;Park, Hyung-kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4335-4347
    • /
    • 2015
  • The objective of this study was to investigate $PM_{10}$ and $CO_2$ concentrations in the classrooms of 286 elementary schools in Suwon, Ansan, and Hwaseong in the province of Gyeonggi between August 2008 and December 2012. By gaining an understanding of the environmental factors that influence these concentrations, this study also aimed to establish a management plan for indoor air quality in schools, which substantially affects the health of elementary students. When the schools were classified by region, no statistically significant difference in $PM_{10}$ concentration was observed. However, $PM_{10}$ concentration was relatively high in industrial areas and low in rural areas. No difference in $CO_2$ concentration was observed among the surveyed cities. Analysis of annual $PM_{10}$ concentration showed that the highest values for Suwon and Hwaseong occurred in 2008 and 2009, respectively (p<0.01). In the case of Ansan, the highest concentration occurred during 2009, but the difference was not significant compared to the other years. Analysis of the annual $CO_2$ concentration of each city shows no significant difference among the cities (p-value=0.366,0.730,0.210). According to a time series analysis of $PM_{10}$ and $CO_2$ by season, from autumn 2008 to winter 2012, $PM_{10}$ concentration was high during 2009, then it gradually decreased until 2012, and started to increase again. While no difference in annual $CO_2$ concentration was observed, the concentration had a tendency to be higher in spring and winter than in summer. By analyzing the relationship between $PM_{10}$ and $CO_2$ and the environmental factors (years of construction, average students of classroom, temperature, and humidity), it showed a significant negative correlation was found between $CO_2$ and the environmental temperature and humidity, at -0.329 and -0.188, respectively (p<0.01).

Detection Ability of Occlusion Object in Deep Learning Algorithm depending on Image Qualities (영상품질별 학습기반 알고리즘 폐색영역 객체 검출 능력 분석)

  • LEE, Jeong-Min;HAM, Geon-Woo;BAE, Kyoung-Ho;PARK, Hong-Ki
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.82-98
    • /
    • 2019
  • The importance of spatial information is rapidly rising. In particular, 3D spatial information construction and modeling for Real World Objects, such as smart cities and digital twins, has become an important core technology. The constructed 3D spatial information is used in various fields such as land management, landscape analysis, environment and welfare service. Three-dimensional modeling with image has the hig visibility and reality of objects by generating texturing. However, some texturing might have occlusion area inevitably generated due to physical deposits such as roadside trees, adjacent objects, vehicles, banners, etc. at the time of acquiring image Such occlusion area is a major cause of the deterioration of reality and accuracy of the constructed 3D modeling. Various studies have been conducted to solve the occlusion area. Recently the researches of deep learning algorithm have been conducted for detecting and resolving the occlusion area. For deep learning algorithm, sufficient training data is required, and the collected training data quality directly affects the performance and the result of the deep learning. Therefore, this study analyzed the ability of detecting the occlusion area of the image using various image quality to verify the performance and the result of deep learning according to the quality of the learning data. An image containing an object that causes occlusion is generated for each artificial and quantified image quality and applied to the implemented deep learning algorithm. The study found that the image quality for adjusting brightness was lower at 0.56 detection ratio for brighter images and that the image quality for pixel size and artificial noise control decreased rapidly from images adjusted from the main image to the middle level. In the F-measure performance evaluation method, the change in noise-controlled image resolution was the highest at 0.53 points. The ability to detect occlusion zones by image quality will be used as a valuable criterion for actual application of deep learning in the future. In the acquiring image, it is expected to contribute a lot to the practical application of deep learning by providing a certain level of image acquisition.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Study on Standardization of the Environmental Impact Evaluation Method of Extremely Low Frequency Magnetic Fields near High Voltage Overhead Transmission Lines (고압 가공송전선로의 극저주파자기장 환경영향평가 방법 표준화에 관한 연구)

  • Park, Sung-Ae;Jung, Joonsig;Choi, Taebong;Jeong, Minjoo;Kim, Bu-Kyung;Lee, Jongchun
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.658-673
    • /
    • 2018
  • Social conflicts with extremely low frequency magnetic field(ELF-MF) exposures are expected to exacerbate due to continued increase in electric power demand and construction of high voltage transmission lines(HVTL). However, in current environmental impact assessment(EIA) act, specific guidelines have not been included concretely about EIA of ELF-MF. Therefore, this study conducted a standardization study on EIA method through case analysis, field measurement, and expert consultation of the EIA for the ELF-MF near HVTL which is the main cause of exposures. The status of the EIA of the ELF-MF and the problem to be improved are derived and the EIA method which can solve it is suggested. The main contents of the study is that the physical characteristics of the ELF-MF affected by distance and powerload should be considered at all stages of EIA(survey of the current situation - Prediction of the impacts - preparation of mitigation plan ? post EIA planning). Based on this study, we also suggested the 'Measurement method for extremely low frequency magnetic field on transmission line' and 'Table for extremely low frequency magnetic field measurement record on transmission line'. The results of this study can be applied to the EIA that minimizes the damage and conflict to the construction of transmission line and derives rational measures at the present time when the human hazard to long term exposure of the ELF-MF is unclear.

Differences in the Soundscape Characteristics of a Natural Park and an Urban Park (자연공원과 도시공원의 Soundscape 특성 차이)

  • Gim, Ji-youn;Lee, Jae-Yoon;Ki, Kyong-Seok
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.1
    • /
    • pp.112-118
    • /
    • 2017
  • The purpose of this study is to clarify the characteristics of the soundscape in a natural park and an urban park. The study sites were a natural park (Chiaksan Nationalpark) and an urban park (Rose Park) in Wonju City, Gangwon Province. Soundscape recording was conducted using Digital Recorder from April 2015 to January 2016. The analysis period was 8 days per season, with a total of 64 days (2 places). Analysis items were soundscape's daily cycle, soundscape type, and seasonal variation. According to the result of the daily cycle analysis of the soundscape, the natural park was dominated by the biophony in accordance with the cycle of the sun, and the airplane sound was observed in the daytime. Meanwhile, anthrophony was consistently produced in the urban park 24 hours a day. As a result of the detailed type analysis of the soundscape, the sources of biophony were classified into wild birds, mammals, insects and amphibians, and the sources of geophony were classified into rain and wind. The anthrophony was mostly airplane sound. In the urban park, wild birds appeared to most influence the biophonic sounds while rain and the wind were the most frequent sounds that contribute to geophony. The most influential components of anthrophony in the urban park were in the order of automobiles, people, music, construction, cleaning, and airplane sound. As a result of the seasonal difference analysis of the soundscape, it was statistically significant that the natural park shows higher biophony in spring, summer, and autumn compared to the urban park. Anthrophony in the urban park appeared to be higher than the natural park in all seasons. The significance of this study is that it is the first study to identify the characteristics of the soundscape of a natural park and an urban park emanating from different landscapes in South Korea.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

A Study on the Structure Style of Street Green Spaces on Port Island, Kobe, Japan (일본 고베시(神戶市) 포트아일랜드 가로녹지 구조 유형 연구)

  • Kwak, Jeong-In;Han, Bong-Ho;Noh, Tai-Hwan;Kwak, Nam-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.62-74
    • /
    • 2015
  • This study was carried out to provide examples of planting methods for the construction of street green spaces with abundant greenery by analyzing road type, surrounding land use and planting structures in street green spaces on Port Island, Kobe, Japan. Port Island_(total area: 826ha) is a marine cultural city located in Japan's first artificial island with facilities of urban function and port facilities. The study site was designated at 11 plots of $55{\sim}285m^2$ on Port Island, and topography structure styles were divided into four types with mounding style, slope style, slope and flat style, flat style according to the adjacent roads width. The area adjacent to the middle roads with high levels of noise and pollution set up the mounding style, slope style, slope and flat style of multi-layer structures using topographic properties. The area adjacent to small roads focused on a green strip with shrubs on a flat style. Surrounding land-uses include a public institution, housing complex, and a commercial building. The planting concept was a buffer and landspace function in case of the middle road_(lane 4) while the small road_(lane 2) was a landspace function. Planting species were diverse with Liquidambe formosana, Cinnamomum camphora, Sapium sebiferum, Cedrela sinensis, Laeocarpus sylvestris var. ellipticus, Ginkgo biloba, Prunus serrulata var. spontanea, Zelkova serrata, Quercus glauca, Juniperus chinensis, Magnolia kobus, Rhododendron spp., Camellia japonica, Abelia mosanensis, etc. Planting density was 0.02~0.08(0.04) individual/$m^2$ at the canopy layer, 0.02~0.08(0.04) individual/$m^2$ at the understory layer. Ratio of green coverage was 40.0~173.7(93.0)% at the canopy layer, 2.1~79.8(34.9)% at the understory layer and 17.9~64.2(32.9)% at the shrub layer. $Gr{\ddot{u}}volumenzahl$ was $1.43{\sim}6.67(4.13)m^3/m^2$ at the canopy layer, $0.02{\sim}2.01(0.85)m^3/m^2$ at the understory layer and $0.14{\sim}0.58(0.26)m^3/m^2$ at the shrub layer. The ratio of green coverage of street green space on Port Island was higher than that of Seoul, and particularly, the ratio of green coverage and $gr{\ddot{u}}volumenzahl$ at the shrub layer differed, compared to the main street green space in Korea. The result of this study may be applicable to other coastal reclaimed cities in terms of setting methods for street greenery considering the topography structure, planting structure and planting function.