• 제목/요약/키워드: Constant volume method

검색결과 404건 처리시간 0.024초

Transient heat transfer analysis of functionally graded CNT reinforced cylinders with various boundary conditions

  • Moradi-Dastjerdi, Rasool;Payganeh, Gholamhassan
    • Steel and Composite Structures
    • /
    • 제24권3호
    • /
    • pp.359-367
    • /
    • 2017
  • In this work, transient heat transfer analysis of functionally graded (FG) carbon nanotube reinforced nanocomposite (CNTRC) cylinders with various essential and natural boundary conditions is investigated by a mesh-free method. The cylinders are subjected to thermal flux, convection environments and constant temperature faces. The material properties of the nanocomposite are estimated by an extended micro mechanical model in volume fraction form. The distribution of carbon nanotube (CNT) has a linear variation along the radial direction of axisymmetric cylinder. In the mesh-free analysis, moving least squares shape functions are used for approximation of temperature field in the weak form of heat transform equation and the transformation method is used for the imposition of essential boundary conditions. Newmark method is applied for solution time depended problem. The effects of CNT distribution pattern and volume fraction, cylinder thickness and boundary conditions are investigated on the transient temperature field of the nanocomposite cylinders.

체적요소기법을 이용한 비균질 유전체의 산란특성 (Electromagnetic Scattering of Inhomogeneous Dielectric Body using Tetrahedral Modeling Method)

  • 배근식;김채영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1747-1749
    • /
    • 1996
  • A method for calculating the electromagnetic scattering from arid internal field distribution of arbitrally, shaped, inhomogeneous dielectric bodies is presented. Tetrahedral volume elements are used to model a scattering body in which the electrical parameters are defined constant in each tetrahedron. Special basis functions are defined within the tetrahedral volume elements to satisfy the boundary condition at interfaces between different dielectric media. In order to test the accuracy of the solution by using the present method, it is applied to obtain the scattered field by the dielectric sphere. The accuracy of the fields calculated by using the tetrahedral cell method is found to be comparable to that of others.

  • PDF

철손 저감을 위한 유도전동기 고정자 슬롯 형상 최적화 (Stator Slot Shape Optimization of Induction Motors for Iron Loss Reduction)

  • 박석배;이향범;박일한;정태경;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.150-152
    • /
    • 1994
  • In this paper, the optimum shape design of stator slot of induction motors for iron loss reduction is proposed. To obtain the flux distribution in induction motors, 2-D finite element method with voltage source is employed. The iron loss is calculated from the iron loss data given by the iron manufacturer. To calculate the sensitivity of iron loss to shape variation, the sensitivity analysis of discrete approach is used. The proposed algorithm is applied to a 3-phase squirrel cage induction motor. The nodes at stator slot boundary of the induction motor are defined as design parameters. By controlling these parameters under the constant volume of iron, we can minimize the iron loss. Furthermore, the stator copper loss is reduced by increasing the slot area. So the stator slot area is determined at the point that the summation of iron loss and copper loss of stator is minimized. Since the constraint of constant volume of iron is nonlinear to the design parameters, the Gradient Projection method is used as an optimization algorithm.

  • PDF

Effect of Fuel Injector-type Spark Plug on Combustion Characteristics

  • Yeom, J.K.;Chung, S.S.
    • 한국분무공학회지
    • /
    • 제14권4호
    • /
    • pp.171-177
    • /
    • 2009
  • This study proposes a new stratified charge system for low emission and ultra lean burn. In order to examine combustion characteristics of the new system, sparkplug with a hole at positive pole and a common CNG injector for injecting fuel were used in this study as injector-type spark plug. The new stratified charge system injects fuel of extremely small quantities and ignites mixture around sparkplug gap. Also, the system was fitted in a visualized constant volume chamber. Then, for analysis of the combustion characteristics, we examined combustion pressure, lean inflammable limit, and visualized combustion flame according to equivalence ratio by comparison with homogeneous charge (HC) method and the new stratified charge (SC) method. As results of this study, in the case of using this system, the propagation speed of initial flame was increased and total combustion period was reduced in the ultra lean burn in the same equivalence ratio. These phenomena occurred clearly under the conditions of lean equivalence ratio. Furthermore, the lean inflammable limit of mixture was extended by using the injector-type spark plug.

  • PDF

3차원 유한요소법을 이용한 T형 가지관의 용접자리 성형 방법에 관한 연구 (A Study on the T-branch Forming with 3-D Finite Element Method)

  • 홍대훈;황두순;신동필;홍성인
    • 소성∙가공
    • /
    • 제10권1호
    • /
    • pp.23-29
    • /
    • 2001
  • In this study, the optimized initial hole shape for T-branch forming was proposed to obtain effective welding region. Design variables were determined by approximation analysis using volume constant condition. We performed 3D elastic-plastic FEM(Finite Element Method) analysis to simulate T-branch forming process. The variation of height and thickness of T-branch with various hole shapes was investigated. The optimized initial hole shape equation was obtained by using results for the numerical analysis.

  • PDF

Efficient Optimum Design of Reinforced Concrete Structures using the Mixed-Discrete Optimization Method

  • Kim, Jong-Ok
    • 한국농공학회지
    • /
    • 제39권2호
    • /
    • pp.32-43
    • /
    • 1997
  • Abstract A series of permeability tests was performed on the mixtures with specific mixing rates of sand and bentonite using modified rigid-wall permeameter. Sand-bentonite mixtures were permeated by organics, ethanol and TCE. Permeability of bentonite with several mixing rates had a tendency to decrease up to initial one pore volume and permeability was thereafter converged to a constant value. When sand-bentonite mixtures was permeated by water, permeability was decreased at the beginning but it was thereafter converged to a constant. Among several mixing rates, permeability was greatly decreased at 15% of mixing rate. When sand-bentonite mixtures with 15% mixing rate was permeated by ethanol, permeability was about 10 times larger value than permeability of water. Peameability was shown greater values when permeated by TCE (TrichloroEthylene) followed by ethanol. Suitable mixing rate of sand-bentonite for a liner of waste landfills was detected.

Rod 호수에 따른 Permanent Design 연구 (A Study on the Permanent Design of Rods Each Number)

  • 이수희;조고미
    • 패션비즈니스
    • /
    • 제12권2호
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study is to explore to determine the maximum volume with doing permanent waving in flat crown of the head. The method was like this. First of all, the diameter, the ratio of the circumference of a circle to its diameter and the number of rotations were analyzed same hair using permanent waving rods each number of 1$\sim$10. Secondly, the increasing rate of volume of curls number of 1$\sim$10 was analyzed. According to the result of the experiment, as the number of permanent waving rods were bigger, the ratio of the circumference of a circle to its diameter constant was increasing but the number of rotations was decreased. When the permanent waving rods of each number 1-3(Big diameter) were used, the volume was decreased. That's because there was fewer rotation compared to the diameter and was no ample combed dried hair. Due to this kind of reason, there was no perfect curling. Once number 10 permanent waving rods (most small size) was used, the shape of curling was strong and the stability was made after combed dried hair. But volume was decreased by 9% because of the cohesive power. In case of number of 4$\sim$9 rods used, volume was increased. Volume was highest when permanent waving rods was number 5 which was used combing on base both morphology and numerical value.

엇갈린 핀 배열을 갖는 평판 열교환기의 최적 설계 (Design Optimization of Plate Heat Exchanger with Staggered Pin Arrays)

  • 박경우;최동훈;이관수;장규호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1441-1446
    • /
    • 2003
  • The design optimization of the plate heat exchanger with staggered pin arrays for a fixed volume is performed numerically. The flow and thermal fields are assumed to be a streamwise-periodic flow and heat transfer with constant wall temperature and they are solved by using the finite volume method. The optimization is carried out by using the sequential linear programming (SLP) method and the weighting method is used for solving the multi-objective problem. The results show that the optimal design variables for the weighting coefficient of 0.5 are as follows; S=6.497mm, P=5.496mm, $D_1=0.689mm$, and $D_2=2.396mm$. The Pareto optimal solutions are also presented.

  • PDF

다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서 (Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones)

  • 이동우;이소연;조영호
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

열펌프 가열식 온수기의 동적특성 해석 (Numerical Simulation on Dynamic Characteristics of a Water Heater System Driven by a Heat Pump)

  • 김민성;김민수;백남춘
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.10-20
    • /
    • 2002
  • A dynamic model of a water heater system heated by a heat pump was developed. The water heater system was composed of heat pump and hot water reservoirs. Finite volume method (FVM) was applied to describe the heat exchangers. A new constraint on electronic expansion valve (EEV) or thermostatic expansion valve (TXV) that can control superheat after the evaporator was developed. Dynamic performances were evaluated for various sizes of the reservoir. In order to compare those performances, time scale was normalized by time constant representing the characteristics of reservoir size. Time constant was determined from quasi steady-state simulation of the system. From the simulation, the size of the water heater reservoir was found to have a large influence on the transient performance of the sys- tem. Therefore, the optimization of the reservoir size is needed in a design process.