• Title/Summary/Keyword: Constant rate model

Search Result 889, Processing Time 0.034 seconds

A Study on the Depreciation by Dual Price in Korea (우리나라에서 쌍대가격에 의한 감가상각의 측정에 관한 연구)

  • 조진형
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.14 no.24
    • /
    • pp.15-21
    • /
    • 1991
  • Jones [11], [12]developed a measurement method of the economic depreciation by infinite-horizen linear program model. This paper models an economic depreciation schedule in constant price based on the infinite-horizen LP. And the appropriate application of the maintenance/operating cost, the discount rate, the taxation and the price fluctuation in the model was suggested.

  • PDF

Adsorption Analysis of VOCs of Zeolite Synthesized by Coal Fly Ash in a Fixed-bed Adsorber (고정층 흡착탑에서 석탄비산재로부터 합성한 Zeolite의 VOCs 흡착 해석)

  • Kim, Seong-Soo;Lee, Chang-Han;Park, Sang-Wook
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.784-790
    • /
    • 2010
  • VOCs such as acetone, benzene, toluene, ethylbenzene were adsorbed in a fixed-bed adsorber using zeolite synthesized from coal fly ash and 4 kinds of activated carbon at 101.3 kPa. The adsorber was operated batchwise with the charge of 5 g adsorbent to obtain the breakthrough curve of VOCs. Experiments were carried out at $40^{\circ}C$, nitrogen flow rate of $70cm^3/min$ and sparger temperature of $30^{\circ}C$. The deactivation model was tested for these curves by combining the adsorption of VOCs and the deactivation of adsorbent particles. The observed values of the adsorption rate constant and the deactivation rate constant were evaluated through analysis of the experimental breakthrough data using a nonlinear least square technique. The experimental breakthrough data were fitted very well to the deactivation model than the adsorption isotherm models in the literature. Also, adsorption capacities of adsorbents were obtained from the breakthrough curve to observe the correlation between adsorption capacity and the physical properties of VOCs.

Power-Efficient Rate Allocation of Wireless Access Networks with Sleep-Operation Management for Multihoming Services

  • Lee, Joohyung;Yun, Seonghwa;Oh, Hyeontaek;Newaz, S.H. Shah;Choi, Seong Gon;Choi, Jun Kyun
    • Journal of Communications and Networks
    • /
    • v.18 no.4
    • /
    • pp.619-628
    • /
    • 2016
  • This paper describes a theoretical framework for rate allocation to maximize the power efficiency of overall heterogeneous wireless networks whose users are assumed to have multihoming capabilities. Therefore, the paper first presents a power consumption model considering the circuit power and radio transmission power of each wireless network. Using this model, two novel power efficient rate allocation schemes (PERAS) for multihoming services are proposed. In this paper, the convex optimization problem for maximizing the power efficiency over wireless networks is formulated and solved while guaranteeing the required quality of service (QoS). Here, both constant bit rate and variable bit rate services are considered. Furthermore, we extend our theoretical framework by considering the sleep-operation management of wireless networks. The performance results obtained from numerical analysis reveal that the two proposed schemes offer superior performance over the existing rate allocation schemes for multihoming services and guarantee the required QoS.

A Study on Improved Heating Performance of an Apartment Housing Unit (공동주택 세대별 난방 성능 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

MODELING AND ANALYSIS OF AN EPIDEMIC MODEL WITH CLASSICAL KERMACK-MCKENDRICK INCIDENCE RATE UNDER TREATMENT

  • Kar, T.K.;Batabyal, Ashim;Agarwal, R.P.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.14 no.1
    • /
    • pp.1-16
    • /
    • 2010
  • An epidemic model with Classical Kermack-Mckendrick incidence rate under a limited resource for treatment is proposed to understand the effect of the capacity for treatment. We have assumed that treatment function is strictly increasing function of infective individuals and becomes constant when the number of infective is very large. Existence and stability of the disease free and endemic equilibrium are investigated, boundedness of the solutions are shown. Even in this simple version of the model, backward bifurcation and multiple epidemic steady states can be observed with some sets of parameter values. Hopf-bifurcation analyses are given and numerical examples are provided to help understanding.

Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber (공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법)

  • Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

The Development of Estimation Model for Iron Compound Originated from Anaerobic Microbial Corrosion (혐기성 미생물부식에 의해 생성되는 철화합물 추정식 개발)

  • Jeon, Seok-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.379-386
    • /
    • 2002
  • In this study, estimation model for iron compound originated from upflow, anaerobic fixed bed reactor, which treats sewage domestic wastewater, was developed. The estimation model was formulated by a mathematical expression which was based on the mass balance. Below the HRT of 60 minute, sulfide concentration combining with iron $FeS_2$ is the highest because the maximum sulfate consumption rate $V_{maxS}$ and half-saturation constant of sulfate $K_{mS}$ exert an important effect on the estimation model as temperature was increased. But increment of $FeS_2$ concentration is weakened above the HRT of 60 minutes and represent the lowest value at the HRT of 108 minutes. It implies that liquid phase distribution ratio of sulfide ${\alpha}r$ becomes lower as temperature was increased. While phosphorus concentration combining with iron $Fe_3(PO_4)_3$ is increased as HRT and temperature are increased, which is affected by phosphorus removal rate constant $k_p$. As the result of estimating the iron concentrations of corrosion by the model, the concentration of iron corrosion is higher than any other at the HRT of 108 minute and $20^{\circ}C$. The predicted values were compared with measured ones at different HRT(13.5, 27, 54, 108 min) and temperature(20, 25, $30^{\circ}C$). The experimental data could be fitted with the simulated curves. Therefore, the mathematical expression could be applicable to design full-scale wastewater treatment plants.

A Prediction of Shear Behavior of the Weathered Mudstone Soil Using Dynamic Neural Network (동적신경망을 이용한 이암풍화토의 전단거동예측)

  • 김영수;정성관;김기영;김병탁;이상웅;정대웅
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.123-132
    • /
    • 2002
  • The purpose of this study is to predict the shear behavior of the weathered mudstone soil using dynamic neural network which mimics the biological system of human brain. SNN and RNN, which are kinds of the dynamic neural network realizing continuously a pattern recognition as time goes by, are used to predict a nonlinear behavior of soil. After analysis, parameters which have an effect on learning and predicting of neural network, the teaming rate, momentum constant and the optimum neural network model are decided to be 0.5, 0.7, 8$\times$18$\times$2 in SU model and 0.3, 0.9, 8$\times$24$\times$2 in R model. The results of appling both networks showed that both networks predicted the shear behavior of soil in normally consolidated state well, but RNN model which is effective fir input data of irregular patterns predicted more efficiently than SNN model in case of the prediction in overconsolidated state.

Chemically enhanced steam cleaning for the control of ceramic membrane fouling caused by manganese and humic acid (망간과 휴믹산에 의한 세라믹 막 오염의 제어를 위한 약품 스팀세정의 적용)

  • An, Sun-A;Park, Cheol-Gyu;Lee, Jin-San;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.425-436
    • /
    • 2021
  • In this study, chemically enhanced steam cleaning(CESC) was applied as a novel and efficient method for the control of organic and inorganic fouling in ceramic membrane filtration. The constant filtration regression model and the resistance in series model(RISM) were used to investigate the membrane fouling mechanisms. For total filtration, the coefficient of determination(R2) with an approximate value of 1 was obtained in the intermediate blocking model which is considered as the dominant contamination mechanism. In addition, most of the coefficient values showed similar values and this means that the complex fouling was formed during the filtration period. In the RISM, R c/R f increased about 4.37 times in chemically enhanced steam cleaning compared to physical backwashing, which implies that the internal fouling resistance was converted to cake layer resistance, so that the membrane fouling hardly to be removed by physical backwashing could be efficiently removed by chemically enhanced steam cleaning. The results of flux recovery rate showed that high-temperature steam may loosen the structure of the membrane cake layer due to the increase in diffusivity and solubility of chemicals and finally enhance the cleaning effect. As a consequence, it is expected that chemically enhanced steam cleaning can drastically improve the efficiency of membrane filtration process when the characteristics of the foulant are identified.

Development of Predictive Growth Model of Listeria monocytogenes Using Mathematical Quantitative Assessment Model (수학적 정량평가모델을 이용한 Listeria monocytogenes의 성장 예측모델의 개발)

  • Moon, Sung-Yang;Woo, Gun-Jo;Shin, Il-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.194-198
    • /
    • 2005
  • Growth curves of Listeria monocytogenes in modified surimi-based imitation crab (MIC) broth were obtained by measuring cell concentration in MIC broth at different culture conditions [initial cell numbers, $1.0{\times}10^{2},\;1.0{\times}10^{3}\;and\;1.0{\times}10^{4}$, colony forming unit (CFU)/mL; temperature, 15, 20, 25, 37, and $40^{\circ}C$] and applied to Gompertz model to determine microbial growth indicators, maximum specific growth rate constant (k), lag time (LT), and generation time (GT). Maximum specific growth rate of L. monocytogenes increased rapidly with increasing temperature and reached maximum at $37^{\circ}C$, whereas LT and GT decreased with increasing temperature and reached minimum at $37^{\circ}C$. Initial cell number had no effect on k, LT, and GT (p > 0.05). Polynomial and square root models were developed to express combined effects of temperature and initial cell number using Gauss-Newton Algorism. Relative coefficients of experimental k and predicted k of polynomial and square root models were 0.92 and 0.95, respectively, based on response surface model. Results indicate L. monocytogenes growth was mainly affected by temperature and square root model was more effective than polynomial model for growth prediction.