• 제목/요약/키워드: Constant Pressure System

검색결과 570건 처리시간 0.026초

$CaO-MgO-Al_2O_3-SiO_2$계의 글라스-세라믹에서 결정상이 소결체에 미치는 영향 (Effect of Crystal Phases on the Properties of Sintered Glass-Ceramics for $CaO-MgO-Al_2O_3-SiO_2$ System)

  • 김형순
    • 한국세라믹학회지
    • /
    • 제29권7호
    • /
    • pp.558-564
    • /
    • 1992
  • The effect of composed phase in the hot pressed CaO-MgO-Al2O3-SiO2 glass-ceramic has been investigated through microstructure studies, thermal, physical and mechanical properties. Sintering was done in the condition at the temperature range 900~95$0^{\circ}C$ for 20~120 mins under 7.5 MPa unilateral pressure. Sintered ceramics were composed of diopside, anorthite, residual glass and the portion of each phase was dependent on the sintering temperature and the holding time: as the temperature increases, the amount of diopside increased and then the rate of increase of diopside reduced with increasing anorthite. The thermal expansion coefficient of hot pressed was reduced with increasing crystallinity of hot pressed and was in the range of 6.69~7.46$\times$10-6 K-1 below $600^{\circ}C$. The elastic constant of hot pressed increased with increasing crystallinity up to about 80%, but after that was reduced due to the change of microstructure. The flexural strength of sintered ceramics was decreased with higher temperature and holding time, while the fracture toughness of those increased. It was shown that the physical and mechanical properties of hot pressed ceramic were related to the fraction of composed sintered ceramics, similar to a particulate composite, to the crystallinity of 80% of the glass-ceramic.

  • PDF

저온플라즈마 구동 촉매 반응기를 이용한 벤젠과 톨루엔의 처리 (Nonthermal Plasma-Driven Catalysis of Benzene and Toluene)

  • 김현하;오가타 아쯔시;후타무라 시게루
    • 한국대기환경학회지
    • /
    • 제22권1호
    • /
    • pp.43-51
    • /
    • 2006
  • Nonthermal plasma-driven catalysis (PDC) was investigated for the decomposition of benzene and toluene as model compounds of volatile organic compounds (VOCs) at atmospheric pressure and low temperature. Two types of catalysts Ag/$TiO_{2}$ and Pt/$\gamma-Al_{2}O_{3}$ were tested in this study. The amount of catalysts packed in the PDC reactor did not influence on the decomposition efficiency of benzene. The type of catalysts also had no influence on the decomposition efficiency of toluene and carbon balance. The Ag/$TiO_{2}$ catalyst showed constant $CO_{2}$ selectivity of about $73\%$ regardless of the specific input energy. However, the selectivity of $CO_{2}$ was greatly enhanced with the Pt/$\gamma-Al_{2}O_{3}$ catalysts, and reached $97\%$ at 205 J/L. Two test runs with 20 fold difference in the gas flow clearly indicated that lab-scale data can be successfully applied for the scaling-up of PDC system.

Comparison study on membrane fouling by various sludge fractions with long solid retention time in membrane bioreactor

  • Sun, Darren Delai;Liu, Shushu
    • Membrane and Water Treatment
    • /
    • 제4권3호
    • /
    • pp.175-189
    • /
    • 2013
  • A membrane bioreactor (MBR) with sludge retention time (SRT) of 300 days was maintained for over 2 years. Polypropylene microfiltration (MF) membrane with pore size of 0.2 ${\mu}m$ was used in the MBR system. The fouling behaviors of various sludge fractions from the MBR were studied and sub-divided resistances were analyzed. It was observed that $R_{cp}$ was a dominant resistance during the filtration of activated sludge, contributing 63.0% and 59.6% to the total resistance for MBR and sequential batch reactor (SBR) respectively. On the other hand, $R_c$ played the significant role during the filtration of supernatant and solutes, varying between 54.54% and 67.18%. Compared with $R_{cp}$ and $R_c$, $R_{if}$ was negligible, and $R_m$ values remained constant at $0.20{\times}10^{12}m^{-1}$. Furthermore, resistances of all sludge fractions increased linearly with rising mixed liquor suspended solids (MLSS) concentration and growing trans-membrane pressure (TMP), while the relationship was inversed between fraction resistances and cross flow velocity (CFV). Among all fractions of activated sludge, suspended solid was the main contributor to the total resistance. A compact cake layer was clearly observed according to the field emission scanning electro microscopy (FE-SEM) images.

LNG 안전밸브를 지나는 기체 유동에 관한 연구 (A Study of the Gas Flow through a LNG Safety Valve)

  • 이준희;김희동
    • 한국추진공학회지
    • /
    • 제11권4호
    • /
    • pp.19-25
    • /
    • 2007
  • LNG 안전밸브는 LNG 수송배관 내부의 압력조절에 사용되며, 안전밸브를 통하는 유동은 소음과 진동을 동반하기 때문에 시스템에 부정적으로 작용한다. 본 연구에서는 LNG 안전밸브의 실용적인 설계를 위하여, 2차원 축대칭 압축성 Navier-Stokes 방정식에 의한 유한 체적법을 사용하여 LNG 안전밸브를 통하는 압축성 유동의 특성을 수치해석적 방법으로 조사하였으며, 이론해석결과와 비교하였다. 수치해석 결과, 밸브판의 형상 및 노즐출구와 밸브판 사이의 간격은 밸브판에 미치는 기체역학적 힘에 상당한 영향을 미치며, 밸브판에서 추력계수가 급격하게 증가하는 노즐출구와 밸브판 사이의 거리가 존재하는 것을 알았다.

음식물 탈리액 처리를 위한 막결합형 고온 2상 혐기성 소화 공정의 평가 (Evaluation of a Thermophilic Two-Phase Anaerobic Digestion Coupled with Membrane Process for Garbage Leachate Treatment)

  • 이은영;전덕우;이상화;배재호;김정환;김영오
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.21-27
    • /
    • 2012
  • This study evaluated the performance of a thermophilic two-phase anaerobic digestion (TTPAD) coupled with membrane process treating garbage leachate. The pilot-scale treatment system is consisted of thermophilic acidogenic reactor (TAR) and thermophilic methanogenic reactor (TMR) coupled with an ultrafiltration (UF) membrane unit. The hydraulic retention time of TAR and TMR were 4 and 20 days, respectively. Effluent TCOD and SCOD of the TTPAD were $25\;{\pm}\;6\;and\;12\;{\pm}\;3$ g/L, respectively, and the corresponding TCOD and SCOD removal efficiencies were 77% and 81%, respectively. Propionate was major acids as 75% in the effluent. Scum formation was not observed in TTPAD, which might be resulted from complete lipid degradation. However, TTPAD was appeared to be sensitive to free ammonia toxicity. The UF membrane was operated with constant pressure filtration at average TMP 1.3 atm. Permeate flux had a range of 15-30 $L/m^2/hr$. With UF membrane, TCOD removal increased from 77% to 93%, and this SS free effluent would be beneficial to subsequent processes such as ammonia stripping.

Development of high capacity stirling cryocooler

  • Ko, Junseok;Yeom, Hankil;Kim, Hyobong;Hong, Yong-Ju;In, Sehwan;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.51-56
    • /
    • 2015
  • Cryogenic cooling system for HTS electric power devices requires a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has gamma-type configuration. Piston and displacer are supported with flexure spring. A slit-type heat exchanger is adopted for cold and warm-end, and the generated heat is rejected by cooling water. In cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. Moreover, temperatures of cooling water, housing and linear motor are recorded and electric power parameters of driving circuit are also obtained. The developed Stirling cryocooler reaches to 47.8 K within 23.4 min. with no-load. From heat load tests, it shows cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.

Comparison of Potential and Viscous Codes for Water Entry Problem

  • Kwon, Sun-Hong;Park, Chang-Woo;Shin, Jae-Young
    • International Journal of Ocean System Engineering
    • /
    • 제2권1호
    • /
    • pp.32-36
    • /
    • 2012
  • This paper presents a comparison of potential and viscous computational codes for the water entry problem. A po-tential code was developed which adopted the boundary element method to solve the problem. A nonlinear free surface boundary condition was integrated to find new locations of free surface. The dynamic boundary condition was simplified by taking constant potential values for every time steps. The simplified dynamic boundary condition was applied in the new position of the free surface not at the mean level, which is the usual practice for linearized theory. The commercial code FLUENT was used to solve the water entry problem from the viscosity point of view. The movement of the air-liquid interface is traced by distribution of the volume fraction of water in a computational cell. The pressure coefficients were compared with each other, while experimental results published by other researchers were also examined. The characteristics of each method were discussed to clarify merits and limitations when they were applied to the water entry problems.

연동펌프의 유량맥동 조절과 역류현상을 방지하는 장치에 대한 연구 (A Study for Regulating Flow Fluctuation and Preventing Backflow of Peristaltic Pump)

  • 정유석;이철수;이태경
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.28-34
    • /
    • 2016
  • Though a peristaltic pump is a crucial element in miniaturized drug delivery systems, it has some intrinsic disadvantages such as backflow and flow fluctuation. To overcome these limitation, we have developed valve-less peristaltic pump system including orifice and stagnation chamber. we measured flow rate to investigate the performance of rotary peristaltic pump with three rollers and an elastomeric tube pumping a viscous fluid. The flow fluctuations and the backflow happen as a result from the disengagement of the contact interaction between the rollers and the tubes. Stagnation chamber installed in front of orifice plate was composed of rubber tube and gas chamber. By changing orifice hole diameter with stagnation chamber flow rate and pressure in the tube was regulated. The obtained maximum reduction ratio of flow fluctuation is 96.79%.

에폭시/고무 거시계면에서 장시간 절연파괴전압에 대한 연구 (Study on the Long Time Breakdown Voltage in the Macro Interface between Epoxy and Rubber)

  • 박우현;이기식
    • 한국전기전자재료학회논문지
    • /
    • 제15권11호
    • /
    • pp.1003-1008
    • /
    • 2002
  • In this paper, the estimation of lifetime with the various conditions of the interface between toughened epoxy and rubber which are consisting materials of underground power delivery system has been studied. After the measurement of the short time AC interfacial breakdown strength on macro interfaces at room temperature, the breakdown time at several voltages were measured under the constant voltages lower than the short time breakdown voltage. The long time breakdown voltage was calculated by using Inverse Power Law. Two types of interfaces was studied. One was the interface between toughened epoxy and EPDM(Ethylene Prorylene Diene Terpolymer). The other was the interface between toughened epoxy and silicon rubber. Interfacial pressure and roughness of interfaces was determined through the characteristic of short time AC interfacial breakdown strength. Oil condition was no oiled, low viscosity oiled and high viscosity oiled. High viscosity oiled interface between Toughened epoxy and silicon rubber had the best lifetime exponent, 20.69. and the breakdown voltage of this interface after 30 years was evaluated 19.27㎸.

AFM과 FEH을 이용한 저압 터빈 블레이드의 파손해석에 관한 연구 (A Study on Failure Analysis of Low Pressure Trubine Blade Using AFM and FEM)

  • 홍순혁;조석수;주원식
    • 대한기계학회논문집A
    • /
    • 제25권11호
    • /
    • pp.1705-1712
    • /
    • 2001
  • Mechanical component has striation with constant width and SEM can estimate fracture type and loading condition. SEM has benefit to fatigue fracture analysis but striation can be observed according to the kind of material and range of crack growth rate and can't. In this case, it needs AFM that can measure 3-dimensional surface profile with resolution of atomic size. In this study. to find fracture reason of torsion-mounted blade in nuclear plant, we estimate the relation between stress intensity factor range and root mean square roughness in 12% Cr steel by AFM and predict in-service loading condition of turbine blade. failure analysis is performed by finite element method and Goodman diagram on torsion-mounted blade.