• Title/Summary/Keyword: Constant Pressure Control

Search Result 276, Processing Time 0.029 seconds

The Effects of Adherence on Hypertension Control among Newly Diagnosed Hypertension Patients (신규 고혈압 환자에서 치료지속성이 고혈압 조절에 미치는 영향)

  • Han, Jin-Ok;Oh, Dae-Kyu;Yim, Jun;Ko, Kwang-Pil;Lee, Hee Young;Park, Jong Heon;Im, Jeong-Soo
    • Health Policy and Management
    • /
    • v.24 no.2
    • /
    • pp.136-142
    • /
    • 2014
  • Background: This study is to research on how hypertension control is associated with adherence in newly diagnosed hypertension patients. Methods: The study is based on 255,916 patients who were diagnosed with hypertension in 2009 and didn't have any previous medical history of hypertension or associated complication for the past year using data collected by National Health Insurance Corporation. Newly diagnosed hypertension patients are divided into two group by visiting medical center numbers (more than 300 days was adherence group, if not non-adherence group). Patients are considered to have successfully controlled their hypertension based on blood pressure measured by health examination. Chi-square test and logistic regression, repeated measured analysis of variance was used to analyze. Results: The relations between adherence and hypertension control show that 1.12 times of patients in adherence group was able to control their hypertension. The additional analysis proves that adherence group are more decreased level of blood pressure than non-adherence group except for patients who are over 70. Comparison of the average of systolic blood pressure and diastolic blood pressure between adherence and non-adherence groups shows that the blood pressure has been significantly among the adherence group. Conclusion: The study proves that constant treatment for hypertension could control the blood pressure and encourages patients to put more effort for persistent treatment. It also shows that hypertension treatment are more effective in younger patients than the elderly and strategies of approaching are different depending on age.

A study on the combustion characteristics according to evaporation rate of gasoline (가솔린 연료의 기화율 변화에 따른 연소 특성에 관한 기초 연구)

  • Lee, K.H.;Lee, C.S.;Shin, K.S.;Cho, H.M.
    • Journal of ILASS-Korea
    • /
    • v.1 no.3
    • /
    • pp.29-36
    • /
    • 1996
  • The present study systematically investigates the effect of evaporation rate on the combustion characteristics and the flame stabilization in a gasoline engine. A constant volume combustion chamber was used to elucidate a basic combustion characteristics and the premixer was installed to control temperature and equivalence ratio. And the maximum pressure, combustion duration and flame propagation according to the evaporation rate were measured to determine the optimal temperature range for evaparating a gasoline fuel. These experimental results indicate that the combustion characteristics such as combustion chamber pressure and combustion duration were deteriorated by decreasing surrounding temperature of fuel injected. It was also found that the overall gasification process for gasoline fuel was strongly influenced by a combustion chamber temperature rather than a premixer temperature.

  • PDF

Analysis of Filling in Injection Molding with Compressibility (압축성을 고려한 사출성형 충전과정에 관한 연구)

  • Han, Kyeong-Hee;Im, Yong-Taek
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.5
    • /
    • pp.735-745
    • /
    • 1997
  • In this study, the compressibility of resin was considered in filling analysis to account for the possible packing type flow. A numerical simulation program employing a hybrid finite element/finite difference scheme was developed to solve Hele-Shaw flow of the compressible viscous fluid at non-isothermal conditions. To advance the melt front, a control volume approach was adopted. Thin complex 3-D shapes of cavities, runners, and sprues were discretized by employing triangular, cylindrical and/or rectangular strip elements. Mass conservation was applied to each control volume to solve for the pressure distribution. Directly applying a constant mass flow rate at the inlet removes calculation of the apparent pressure boundary conditions, resulting in better simulation condition. The Cross model was used to model viscosity and the Tait equation was employed to represent density as a function of temperature and pressure. The validity of the developed program was verified through comparisons with available data in the literature and the effect of compressibility on the pressure distribution was discussed. To reduce computation time, 1-D and 2-D elements were used instead of applying triangular elements and the numerical results were compared to each other.

A Study on the Development of Polishing Robot System Attached to Machining Center for Curved Surface Die (곡면금형 연마를 위한 머시닝센터 장착형 연마로봇 시스템 개발에 관한 연구)

  • Lee, Min-Cheol;Ha, Deok-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.163-177
    • /
    • 1999
  • Polishing work for a curved surface die demands simple and repetitive operations and requires much time while it demands also high precision. Therefore it is operated by a skilled worker in handiwork. However the workers avoid gradually a polishing work because of the poor environmental conditions such as dust and noise. In order to reduce the polishing time and to alleviate the problem of shortage of skilled workers, an automatic polishing robot system which is composed of a polishing robot with two degrees of freedom motion and pneumatic system is developed, and it is attached to machining center with three degrees of freedom. The system keeps the polishing tool vertically on the surface of die and maintains constant pneumatic pressure. The polishing robot with DSP(digital signal processor) controller is controlled by sliding mode control. A synchronization between machining center and polishing robot is accomplished by using M code of machining center. A performance experiment for polishing work is executed by the developed automatic polishing robot system. The result shows that the developed automatic polishing robot has a good performance and well polished workpiece surface is obtained.

  • PDF

A Study on the Design and Modeling of PWM Fuel Metering Unit for Miniature Turbo Engines (초소형 터보엔진용 PWM 연료조절장치의 설계 및 모델링에 관한 연구)

  • Joo Sang-Hyun;Choi Ho-Jin;Park Jong-Seung;Lim Jin-Shik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 2006
  • A fuel metering unit using PWM(Pulse Width Modulated) solenoid valve has some advantages such as low cost, small size and simple structure. The mathematical model and its experimental rig of the fuel metering unit using PWM solenoid valve and CPDV(Constant Pressure Drop Valve) for miniature turbo engines were constructed. As the results of simulation, some major parameters which have dominant effects on the performance were found. And the experimental results verified the validity of established model by showing the good agreement with the numerical simulation results. Hence, this system modeling could be used effectively in the actual development of a PWM fuel control system.

Optimization of a radiator for a MPFL system in a GEO satellite

  • Afshari, Behzad Mohasel;Abedi, Mohsen;Shahryari, Mehran
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.6
    • /
    • pp.701-709
    • /
    • 2017
  • One of the components that used in the satellite thermal control subsystem is the Mechanically Pumped Fluid Loop (MPFL) system; this system mostly used in geosynchronous orbit (GEO) satellites, and can transfer heat from a hot point to a cold point using the fluid which circulated in a closed loop. Heat radiates to the deep space at the cold plate to cool down the fluid temperature. In this research, the radiative heatexchanger (RHX) for a MPFL system is optimized. The genetic algorithm has been used for minimizing the total mass and pressure drop by considering a constant transferred heat rate at the heat exchanger. The optimization has been done in two cases. In case I, two parameters are considered as a goal function, so optimization is performed using NSGA-II method. Results of optimization are shown in the pareto diagram. In case II, the diameter of pipe is considered constant, so the optimized value for distances of the parallel pipes is obtained by using the genetic algorithm, in which the system has the least total mass. Results show that in the RHX, by increasing the pipe diameter, pressure drop decreases and total mass increases. Also by considering a constant value for pipe diameter, an optimum distance between pipes and pipe length are obtained in which the system has a minimum mass.

Air detector using the change of dielectric constant for medical applications (의료분야 응용을 위한 유전상수 변화를 이용한 공기감지 장치)

  • Kim, Kyung-Hwa;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.864-870
    • /
    • 2010
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed air detection system with air control equipment, detection circuit and LabVIEW system for air sensing. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the Tygon tube of the mock system.

Effect of the Change in Injection Pressure on the Mixture Formation Process in Evaporative Free Diesel Spray (분사압력변화가 증발자유디젤분무의 혼합기형성과정에 미치는 영향)

  • Yeom, J.K.;Chung, S.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.214-219
    • /
    • 2005
  • The effects of change in injection pressure on spray structure in high temperature and pressure field have been investigated. The analysis of liquid and vapor phases of injected fuel is important for emissions control of diesel engines. Therefore, this work examines the evaporating spray structure using a constant volume vessel. The injection pressure is selected as the experimental parameter, is changed from 72MPa to 112MPa by using a common rail injection system(ECD-U2). The images of liquid and vapor phase in the evaporating free diesel spray are simultaneously taken by exciplex fluorescence method. As a result, it can be confirmed that the distribution of vapor concentration is more uniform in the case of the high injection than in that of the low injection pressure.

  • PDF

A comparison of steam turbine control systems according to adoption of turbine bypass system (바이패스 시스템 체용 유무에 따른 증기 터빈제어 비교)

  • Choi, I.K.;Kim, J.A.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2342-2344
    • /
    • 2000
  • Many years ago, most of thermal power plants built in this country were of subcritical pressure, of medium or small size, of constant pressure operation, of drum type steam generator. But, nowadays, almost all of them were of high efficiency, of supercritical pressure, of great capacity(about 500MW), of sliding pressure operation, of once through type steam generator. Presently built once through boiler introduces turbine bypass systems to variable pressure operation which eliminates unexpected materials in boiler tube during startup, minimizes fuel loss by short startup period, eventually improves total efficiency and power system stability

  • PDF

Mini PC control system for BYG type water supply units (BYG형 급수기의 MINI PC 제어 시스템)

  • 박용규;강영모
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1167-1171
    • /
    • 1993
  • A highly efficient hydropneumatic water supply system type BGY is designed and built in accordance with ISO standard. The technical features of BYG type pump unit can be summarized as follows: - reduce hydropneumatic tank capacity at the ratio of 1/10 - 1/30 compared with conventional method. - ISO standard pumps can be used. - the development of highly efficient water supply system type BYG is based on long-term experiences with the proven constant pressure water supply technique which minimize pressure fluctuation, rapid pilsation, etc. The text contains the operation principle of BYG type water supply system, introduction of closed cycle control process focused on Mini PC and experimental results of type BYG-IVS-90x45.

  • PDF