• Title/Summary/Keyword: Constant Force Mechanism

Search Result 88, Processing Time 0.023 seconds

Analysis and Design of Constant-Force Mechanisms Using a Linear Spring (선형 스프링을 이용한 상력 메커니즘의 분석 및 설계)

  • Kim, Whee-Kuk;Kim, Hae-Soo;Kim, Min-Gun;Yi, Byung-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.215-222
    • /
    • 2003
  • In this paper, kinematic analysis and design of constant force mechanisms which employ a linear spring are studied. Firstly, sufficient conditions for the mechanisms to be the constant force mechanisms are derived in terms of displacement variables through the kinematic analysis. Secondly, a few conceptual mechanisms satisfying these constraints are proposed.

Cutting Force Estimation Considering the Specific Cutting Force Constant (비절삭 저항상수에 따른 절삭력 예측)

  • Kim, Jong-Do;Yoon, Moon-Chul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.75-82
    • /
    • 2019
  • Few studies have been conducted regarding theoretical turning force modelling while considering cutting constant. In this paper, a new cutting force modelling technique was suggested which considers the specific cutting force coefficients for turning. The specific cutting force is the multiplication of the cutting force coefficient and uncut chip thickness. This parameter was used for experimental modelling and prediction of theoretical cutting force. These coefficients, which can be obtained by fitting measured average forces in several conditions, were used for the formulation of three theoretical cutting forces for turning. The cutting force mechanism was verified in this research and its results were compared with each of the experimental and theoretical forces. The deviation of force was incurred by a small amount in this model and the predicted force considering feed rate, nose radius, and radial depth shows a physical behavior in main force, normal force, and feeding force, respectively. Therefore, this modelling technique can be used to effectively predict three turning forces with different tool geometries considering cutting force coefficients.

A Study on the Nylon Wire Holding and Release Mechanism for Cube Satellites by Applying Constant Holding

  • Koo, KeonWoo
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.4
    • /
    • pp.1-6
    • /
    • 2021
  • The non-explosive holding and release mechanism is used to prevent damage to the mission component caused by explosives when the deployment structure for Cube Satellites is separated. However, among the several types available, the non-explosive holding and release mechanism system using nylon wires depend on the nylon wire knot method and tightening power of the worker. Therefore, in this study, we conducted experiments with the operation of a new holding and release mechanism system by conceptualizing the Boa System Dial, which can provide a constant tightening force regardless of worker proficiency and deploying a imitational solar panel. In this study, the process of binding and unbinding with constant tension was recorded while applying the novel non-explosive holding and release mechanism using the Boa System Dial proposed. In addition, required advances are indicated for the application of the proposed system to actual Cube Satellites.

Musculotendon Model to Represent Characteristics of Muscle Fatigue due to Functional Electrical Stimulation (기능적 전기자극에 의한 근육피로의 특성을 표현하는 근육 모델)

  • Lim, Jong-Kwang;Nam, Moon-Hyon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.1046-1053
    • /
    • 1999
  • The musculotendon model is presented to show the declines in muscle force and shortening velocity during muscle fatigue due to the repeated functional electrical stimulation (FES). It consists of the nonlinear activation and contraction dynamics including physiological concepts of muscle fatigue. The activation dynamics represents $Ca^{2+}$ binding and unbinding mechanism with troponins of cross-bridges in sarcoplasm. It has the constant binding rate or activation time constant and two step nonlinear unbinding rate or inactivation time constant. The contraction dynamics is the modified Hill type model to represent muscle force - length and muscle force - velocity relations. A muscle fatigue profile as a function of the intracellular acidification, pH is applied into the contraction dynamics to represent the force decline. The computer simulation shows that muscle force and shortening velocity decline in stimulation time. And we validate the model. The model can predicts the proper muscle force without changing its parameters even when existing the estimation errors of the optimal fiber length. The change in the estimate of the optimal fiber length has an effect only on muscle time constant in transient period not on the tetanic force in the steady-state and relaxation periods.

  • PDF

Muscle Force Potentiation During Constant Electrical Stimulation - Dependence on Pulse-Amplitude and Pulse-Duration of Electrical Stimulation (일정 전기자극하의 근력 상승 - 전기 자극 파형의 펄스 진폭과 펄스폭에 대한 의존성)

  • Kim, Ji-Won;Kwang, Min-Young;Eom, Gwang-Moon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.10
    • /
    • pp.458-463
    • /
    • 2006
  • The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration with different ramp-up time. The experimental results showed that the force increment ratio (FIR) during constant electrical stimulation decreased with pulse-amplitude and also with pulse-duration. The FIR was greater with short ramp-up time in both the pulse-amplitude and pulse-width modulation. The feasible mechanism might be that the myosin light chain phosphorylation induces the force potentiation and it occurs only in the fast type muscle fibers which are recruited first. These observations indicate that muscle potentiation must be understood well for the accurate control of muscle force.

A Study on the Automatic Impact Force Control Mechanism Design for the Hydraulic (유압 브레이커의 자동타격력 제어기구 설계에 관한 연구)

  • Kang, Young Ky;Jang, Joo Sup
    • Journal of Drive and Control
    • /
    • v.19 no.3
    • /
    • pp.1-8
    • /
    • 2022
  • In this paper, the design of automatic impact force control mechanism of hydraulic breaker was studied. The control mechanism uses the change of piston upper chamber pressure, when the hydraulic breaker impacts various strength rock. The piston stroke is controlled by rock strength sensing valve, piston stroke switching valve, and piston control valve. It is imperative to denote the area of each valve section, the spring constant of the spring. It provides convenience to users by automatically adjusting the appropriate striking force, according to the strength of the rock. Additionally, by increasing work productivity, it can contribute to reducing greenhouse gas emissions due to fuel efficiency reduction.

Model Identification of Hydraulic Pin-On-Disk type Tribotester with DDV

  • Kim, Seung-Hyun;Lee, Chang-Don;Lee, Jin-Kul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.170.1-170
    • /
    • 2001
  • This paper developed the model for electro hydraulic force control system by identification method via ARMAX model. Implementation of Identification is performed on Pin-On-Disk type tribotester. The wear mechanism is an important mechanic property to select a material´s life and a optimum work condition. Pin-on-disk type tribotester is popular wear analysis experimental equipment and its mechanism is that adding a force on a rotating disk to simplify two surface contact´s wear experimental condition. Material´s rotating velocity and eccentricity rotation makes disturbance and it affects adding constant force. To get a high performance of force adding part, DDV(Direct Drive Valve) which has pressure control loop is used. To obtain a tribotester´ s ARMAX model, prediction error method(PEM) is used in case force adding part and rotating part is ...

  • PDF

Development of an Energy Absorbing Mechanism for Car Seat using Magnesium Alloys (마그네슘 소재를 이용한 차량용 시트의 충격 흡수 기구 개발)

  • Shin, Hyun-Woo;Park, June-Gyu;Lee, Kyu-Hung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.67-75
    • /
    • 2011
  • A new energy absorbing mechanism for car seat was developed to reduce the neck injury in rear impacts. Energy absorbing principle is based on the shear-bolt behavior of thin-walled cast components subjected to static and dynamic loads. Results of shear bolt test using AM60 of Mg alloys showed robust behavior giving an approximately constant mean force during failure processes. Simply designed energy absorbing mechanism was assembled with the recliner between seat backs and seat rails. We have simulated the sled test of seat with dummy under the rear end impact using the finite element method. Results of simulation show that the new seat mechanism reduces thorax acceleration to a considerable extent, but it is not sufficient to mitigate neck injury indices e.g. neck shear force, neck tension force and NIC. With heightened headrest and narrowed backset, the energy absorbing mechanism resulted in good performance of protecting the neck injuries.

A Fundamental Study on the Development of a Variable Preload Device Using Toggle Joint Mechanism (토글 조인트장치를 이용한 가변예압장치 개발을 위한 기초 연구)

  • Choi, Chi Hyuk;Cha, Na Hyeon;Lee, Choon Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.260-265
    • /
    • 2013
  • To increase the machine accuracy by improving the stiffness of spindle bearings, preload was applied to the spindle bearings. The methods of fixed position preload, convertible preload, constant pressure preload, and variable preload are used to apply the preload to the spindle bearing. The previous studies performed by the author of this study were variable preload methods using rubber pressure and centrifugal force based on mechanical systems. This study proposed a toggle joint mechanism that could be applied to variable preload method using centrifugal force and rubber pressure to increase the preload. Also, a finite element analysis was conducted to predict the deformation of the rubber and change of the preload. And the analysis results showed that the preload by the device using rubber pressure only was increased by the toggle joint mechanism using rubber pressure.

A Kinematic Analysis on Piston Rod Mechanism in Swashplate Type Hydraulic Axial Piston Motor/Pump Using Constant Velocity Joint (등속조인트를 적용한 사판식 유압 모터/점프의 로드형 피스톤에 대한 운동해석)

  • Kim K.H.;Kim S.D.;Ham Y.B.;Lee J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Recently, swash plate type hydraulic axial piston motors/pumps are being extensively used in the world, because of simple design, light weight and effective cost. Structural problem of the swash plate type motor/pump is that tilting angle of swash plate should be limited to relatively small value and lateral farce on pistons has an undesirable effect in reciprocating motion. To solve these problems, piston rod mechanism, which is commonly used in bent axis type motor/pump, is considered to be applied to the swash plate type motor/pump. In this paper, kinematic analysis was done on the piston rod mechanism. A series of formula were derived and numerical calculations were done for a set of motor parameters.

  • PDF