• Title/Summary/Keyword: Connector

Search Result 834, Processing Time 0.028 seconds

An Experimental Study on the Shear Connection of Inverted T-shape Composite Beam Encased Web (역T형강 합성보의 전단연결에 관한 실험적 연구)

  • Jeong, Jae-Hun;Kim, Jin-Mu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.131-138
    • /
    • 2001
  • In inverted T-shape composite beam examine the structural behavior by experiment According to arrangement, type of stud connector, type of shear connector, reinforcement by welding of stirrup and a close analysis we came to these conclusion. 1) The compare result of bending strength according to arrange type of stud connector : A1-W(stud connector located web)specimen is exceed than A1-F(stud connector located flange). 2) B1-N(using prominence and depression of the web by shear connector) specimen is decrease than A1-W(using stud bolt by shear connector)specimen in bending strength and B2-N(reinforced by welding the stirrup to lower flange)specimen is similar with A2-W specimen. 3) According to reinforced by welding the stirrup to flange, the stiffness and bending strength of the beams are increase. A-scries stirrup comparatively low effective in the increase of strength by welding the stirrup to flange because enough composite effect show by stud connector, but B-series stirrup is comparatively high effective in shear connector effect because shortage of prominence and depression of the web.

  • PDF

A Study on the Characteristics of Wide Band Matching Connector in Round Coaxial Lines (원형 동축 선로에서 광대역 매칭 커넥터의 특성 연구)

  • Kim, Byeong-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.152-157
    • /
    • 2012
  • In this paper, smoothing plane connector have been proposed as the vehicle connector for the wireless access in vehicular environments (5.925GHz) communication. This smoothing plane connector is designed by considering the properties of critical parameter like smoothing distance of start to end point of contact area. The design simulation and results can be used to determine the most suitable smoothing plane wire dimensions for vehicle communication connector. The optimized WAVE connector inserted the smoothing plane wire has insertion loss less than-0.17dB at 5.925GHz. It provides 20% of insertion loss with good performance. Therefore, the simulated results can be effectively used for optimum design of high frequency connector for vehicle communication.

A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study

  • Qasim, Muhammad;Hong, Jae Taek;Natarajan, Raghu N.;An, Howard S.
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.331-336
    • /
    • 2013
  • Objective : The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. Methods : Finite element models representing C7 intralaminar screw constructs with and without the offset connector were developed. Range of motion (ROM) and maximum von Mises stresses in the vertebra for the two techniques were compared under pure moments in flexion, extension, lateral bending and axial rotation. Results : ROM for intralaminar screw construct with offset connector was less than the construct without the offset connector in the three principal directions. The maximum von Misses stress was observed in the C7 vertebra around the pedicle in both constructs. Maximum von Mises stress in the construct without offset connector was found to be 12-30% higher than the corresponding stresses in the construct with offset connector in the three principal directions. Conclusion : This study demonstrated that the intralaminar screw fixation with offset connector is better than the construct without offset connector in terms of biomechanical stability. Construct with the offset connector reduces the ROM of C6-7 segment more significantly compared to the construct without the offset connector and causes lower stresses around the C7 pedicle-vertebral body complex.

Behavior and resistance of truss-type shear connector for composite steel-concrete beams

  • Lima, Jerfson M.;Bezerra, Luciano M.;Bonilla, Jorge;Silva, Ramon S.Y.R.C.;Barbosa, Wallison C.S.
    • Steel and Composite Structures
    • /
    • v.36 no.5
    • /
    • pp.569-586
    • /
    • 2020
  • The behavior of composite steel-concrete beams depends on the transmission of forces between two parts: the concrete slab and the steel I-beam. The shear connector is responsible for the interaction between these two parts. Recently, an alternative shear connector, called Truss Type connector, has been developed; it aligns efficient structural behavior, fast construction and implementation, and low cost when compared to conventional connectors applied in composite structures. However, there is still a lack of full understanding of the mechanical behavior of the Truss Type connector, due to its novelty. Thus, this study aims to analyze the influence of variation of geometric and physical parameters on the shear resistance of the Truss Type connector. In order to investigate those parameters, a non-linear finite element model, able to simulate push-out tests of Truss Type connectors, was specifically developed and validated with experimental results. A thorough parametric study, varying the height, the angle between rods, the diameter, and the concrete strength, was conducted to evaluate the shear resistance of the Truss Type connector. In addition, an equation to predict the resistance of the original Truss Type shear connector was proposed.

A Study on the Connector of Floating Platform based on Concrete Structures (콘크리트 구조물 기반 플로팅 플랫폼 연결에 관한 연구)

  • Boldbaatar, Tumenjargal;Yoon, Dae-Gwun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • This study is about the connector of the floating platform in order to ensure safety due to various climate changes. The purpose of this study is to recommend the connector model of floating platform based on concrete structures after reviewing the literatures related in establishing floating structure in case of various climate changes in domestic coast. This study introduces the concept generation, existing model, detailed design and evaluation including current and future development of the technologies of marina floating platform connector based on concrete structures. The results from the research show that the analysed connector design (Rigid Pontoon Connector) provides a highly efficient and practical solution to facilitate connection of stable floating platform.

COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK (타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교)

  • Lee, Young-Jae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

A Study of Design and Analysis on the High-Speed Serial Interface Connector (고속 직렬 인터페이스 커넥터의 설계 및 분석에 대한 연구)

  • Lee, Hosang;Shin, Jaeyoung;Choi, Daeil;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1084-1096
    • /
    • 2016
  • This paper presents method of design and analysis of a high-speed serial interface connector with a data rate of 12.5 Gbps. A high-speed serial interface connector is composed of various material and complex structures. It is very difficult to match the impedance of each discontinuous portion of connector. Therefore, this paper proposes the structure of a connector line that be simplified a connector. In the structure of proposed connector line, this research presents a method for extracting R, L, C and G parameters, analyzing the differential mode impedance, and minimizing the impedance discontinuity using time domain transmissometry and time domain reflectometry. This paper applies the proposed methods in the connector line to the high-speed serial interface connector. The proposed high-speed serial interface connector, which consists of forty-four pins, is analyzed signal transmission characteristics by changing the width and spacing of the four pins. According to the analysis result, as the width of the ground pin increases, the impedance decreases slightly. And as the distance between the ground pin and the signal pin increases, the impedance increases. In addition, as the width of the signal pin increases, the impedance decreases. And as the distance between the signal pin and the signal pin increases, the impedance decreases. The impedance characteristic of initial connector presents ranges from 96 to $139{\Omega}$. Impedance characteristic after applying the structure of proposed connector is shown as a value between 92.6 to $107.5{\Omega}$. This value satisfies the design objective $100{\Omega}{\pm}10%$.

A STRESS ANALYSIS OF FIXED PROSTHESES WITH VARIOUS ORIENTATION OF NONRIGID CONNECTOR (비고정성 연결장치의 위치에 따른 고정성 보철물의 응력분석)

  • Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.85-99
    • /
    • 1996
  • Finite element models were constructed to analyze the mechanical behavior of a three unit fixed partial denture (FPD) with a 2nd premolar and 2nd molar abutment either employing a rigid and nonrigid connector. Gap elements were used to model the clearance space of the nonrigid connector. 1. High stress was generated in the FPD and supporting abutment around the rigid connector. 2. The pattern of stress and deflection is very similar between vertically and 20 degree mesially tilted nonrigid connector at the distal aspect of premolar abutment. 3. FPD with an inverted nonrigid connectors exhibited the worst undesirable mechanical stress states and deformations. 4. Nonrigid connector of normal orientation transmit the load to the abutment tooth, but inverted connector doesn't transmit the force.

  • PDF

A Study on Factors Influencing the Shear Strength of Shear Connectors (전단연결재 강도산정 영향인자에 대한 연구)

  • 여진호;임남형;강영종
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1091-1096
    • /
    • 2001
  • Generally, in a steel girder and the concrete slab act as a composite structure, the connectors must have adequate strength and stiffness. If there are no horizontal or vertical separations at the interface, the connectors are described as rigid, and complete interaction can be said to exist under these idealized circumstances. In previous study, it was considered that the strength of stud is affected by the stud diameter, height of stud and compressive strength of concrete. The differences between previous study and this study are variables, which are shank diameter of shear connector, the spacing of shear connector, the size of specimen and the row of shear connector. So this paper, as a study on the strength of shear connector with the spacing of shear connector, size of specimen (block-out size), row of shear connector and shank diameter of shear connector resulted from the push-out specimen are conducted with ABAQUS program. It is to investigate the effects of characteristics of these factors. The load-slip relations obtained from the experiments are compared with those of analyses. From these results, the trends of stress are stress estimated and compared with push-out test.

  • PDF

Prediction of forming accuracy using FEM analysis in slitting process for connector terminal with micro width (미세폭 슬리팅 공정에서 유한요소해석을 이용한 성형 정밀도 예측)

  • Hong, Seok-Kwan;Lee, Byung-Moon;Kang, Jeong-Jin;Kim, Jong-Deok
    • Design & Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • In the electronic products, connector which play a role of board-to-board connection is an essential part. The manufacture process of this connector involves slitting and bending stage. Recently, manufacturing the connector is becoming more and more difficult as miniaturization of the electronic products. In this study, FEM analysis was performed on slitting and bending process for connector terminal with micro width in order to predict the cause of inaccurate dimension of connector terminal which occurs in actual industrial spot.

  • PDF