Investigation on Ultimate Strength of STS304L Stainless Steel Welded Connection with Base Metal Fracture Using Finite Element Analysis

  • Lee, HooChang;Kim, TaeSoo;Hwang, BoKyung;Cho, TaeJun
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1139-1152
    • /
    • 2018
  • Many studies on the application of stainless steels as structural materials in buildings and infra-structures have been performed thanks to superior characteristics of corrosion resistance, fire resistance and aesthetic appeal. Experimental investigation to estimate the ultimate strength and fracture mode of the fillet-welded connections of cold-formed austenitic stainless steel (STS304L) with better intergranular corrosion resistance than that of austenitic stainless steel, STS304 commonly used has carried out by authors. Specimens were fabricated to fail by base metal fracture not weld metal fracture with main variables of weld lengths according to loading direction. All specimens showed a block shear fracture mode. In this paper, finite element analysis model was developed to predict the ultimate behaviors of welded connection and its validity was verified through the comparison with test results. Since the block shear behavior of welded connection due to stress triaxiality and shear-lag effects is different from that of bolted connection, stress and strain distributions in the critical path of tensile and shear fracture section were investigated. Test and analysis strengths were compared with those by current design specifications such as AISC, EC3 and existing researcher's proposed equations. In addition, through parametric analysis with extended variables, the conditions of end distance and longitudinal weld length for block shear fracture and tensile fracture were suggested.

철골 모멘트 연결부의 구조특성에 따른 지진 거동 연구 (Seismic Behavior of Steel Moment Connections with Different Structural Characteristics)

  • 조창빈
    • 한국안전학회지
    • /
    • 제17권2호
    • /
    • pp.76-84
    • /
    • 2002
  • The seismic behaviors of steel moment connections with different structural characteristics are investigated. The rupture index, which represents the fracture potential, is adopted to study the effect of concrete slab and the relative strength between the coin the beam, and Panel zone on the ductility of connections. The results show that the presence of slab increases the beam strength, imposes constraint near the beam top flange, and consequently, induces concentrated deformation near the beam access hall, which reduces the ductility of the connection. The total deformation capacity of the connection depends not only on the beam but also on the column and panel zone. Therefore, the detrimental slab effects and the relative strength should be considered in the seismic design of the connection.

Stress and Fracture Analyses of Nuclear Power Plant LP Turbine Rotor Discs

  • Lee, Choon-Yeol;Kwon, Jae-Do;Chai, Young S.;Jang, Ki-Sang
    • Journal of Mechanical Science and Technology
    • /
    • 제14권2호
    • /
    • pp.207-214
    • /
    • 2000
  • Fracture phenomenon has been reported on blades, rotors, connections and rotor discs of LP turbines of nuclear power plants, which is caused by fatigue, stress corrosion and erosion. In this study, as a tool of reliability evaluation, a number of stress and fracture analyses were performed on the defected area under various operating conditions using the finite element method. Possible defects on key-way and rotor disc were assumed to be two-dimensional cracks and centrifugal force, temperature distribution and shrink-fit effect were included as external loads. From stress analysis results, stress intensity factors were obtained and these values can be utilized to evaluate reliability and predict remaining lifetime of the turbine discs.

  • PDF

보 단부 용접상세에 따른 고강도강 기둥-보 접합부의 변형능력에 관한 연구 (A Study on Deformation Capacity of High Strength Steel Beam-to-Column Connections According to Welding Detail at Beam End)

  • 오상훈;박해용
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.335-348
    • /
    • 2014
  • 고강도 강의 경우 재료의 높은 항복비와 모재인성 부족으로 인해 휨 구조부재에 적용하기가 용이하지 않다. 고강도 강 휨재의 가장 큰 문제점 중 하나는 일반 연강접합부와 마찬가지로 보 단부의 취성파단이다. 연강접합부의 경우 부재의 보강 및 보 단부의 용접접근공 상세의 개량을 통하여 국내기준의 특수모멘트골조용 접합상세가 다수 개발된 바 있으나 고강도강 접합부에 대한 적용성 평가는 아직까지 미비한 실정이다. 본 연구는 국내에서 개발된 고강도 강(HSA800)을 적용한 기둥-보 접합부의 적용성 평가를 위한 초기단계의 연구이며 보 단부의 용접접근공 상세에 따른 고강도 강 접합부의 구조성능을 실험 및 해석적 방법을 통하여 고찰하였다.

Experimental studies and numerical analysis of the shear behavior of fin plates to tubular columns at ambient and elevated temperatures

  • Jones, M.H.;Wang, Y.C.
    • Steel and Composite Structures
    • /
    • 제8권3호
    • /
    • pp.179-200
    • /
    • 2008
  • This paper reports the results of a recent experimental study into the behavior of welded fin-plate connections to both hollow and concrete filled tubular (CFT) columns under shear. Experiments have been performed at both ambient and elevated temperatures with the aid of an electric kiln. The observed failure modes include fracture of the fin plate and tearing out of the tube around the welds. By considering the results of previously published research, the current design method for similar connections under purely tensile load, in CIDECT Guide 9, based on a deformation limit of 3% of the tube width is shown to be inadequate when evaluating the ultimate strength of such connections. By comparing the results from the current test program which failed in the fin-plate with Eurocode guidance for failure of a fin-plate alone under shear and bending load it is shown that the column face influences the overall connection strength regardless of failure mode. Concrete in-fill is observed to significantly increase the strength of connections over empty specimens, and circular column specimens were observed to exhibit greater strength than similarly proportioned square columns. A finite element (F.E.) model, developed using ABAQUS, is presented and validated against the experimental results in order that extensive parametric tests may be subsequently performed. When validating the model against elevated temperature tests it was found that using reduction factors suggested in published research for the specific steel grades improved results over applying the generic Eurocode elevated temperature steel strength reduction factors.

Behavior and design of stainless steel tubular member welded end connections

  • Kiymaz, Guven;Seckin, Edip
    • Steel and Composite Structures
    • /
    • 제17권3호
    • /
    • pp.253-269
    • /
    • 2014
  • Among the various alternatives to make a steel tubular member connection, making a slotted and gusset plate welded connection is one of the most frequently preferred alternatives. This type of connection is essentially an end connection that is made by slotting the tube longitudinally, inserting the gusset plate and then placing longitudinal fillet welds at the tube-to-plate interface. In this paper an experimental study on the behaviour of such connections in stainless steel is presented. 24 specimens were tested under concentrically applied axial tensile forces for varying tube-to-gusset plate weld lengths. Both circular and box section members were considered in the test program. Load-deformation curves were obtained and comparisons were made in terms of strength and ductility. The results obtained from the study were then critically examined and compared with currently available design guidance for slotted gusset plate welded tubular end connections. It is noted that no specific rules exist in international specifications on structural stainless steel which cover the design of such connections. Therefore, the results of this study are compared with the existing design rules for carbon steel.

Experimental study of beam-column connections with web opening in a low-rise steel frame

  • Wang, Xiuli;Yin, Zhanzhong;Li, Qingfu;Shen, Shizhao
    • Structural Engineering and Mechanics
    • /
    • 제26권3호
    • /
    • pp.263-276
    • /
    • 2007
  • Steel frame structures have been widely used in multi-storey and high-rise buildings and the connections in these structures are critical. In the Northridge and Kobe Earthquake, beam-column connections suffered damage due to brittle fracture. According to seismic design codes, ductility of the beam to column connection is also necessary. A study on the behavior of a beam to column connection with the aim of improving ductility as well as preventing brittle failure was carried out. In order to control the position of a plastic hinge on the beam, a connection with a hole in the beam web was developed. Five specimens with different parameters under cyclic load were assessed. The results are presented in terms of the stress distribution of the beam, hysteretic behavior, and ultimate capacity. Furthermore, the finite element method was also used to analyze the model, and the results were compared with those obtained from the experiment. It is shown from the analysis and experimental results that this type of connection is effective in terms of improving ductility for a beam to column connection in low-rise buildings.

유한요소 해석을 이용한 WUF-W 접합부 최적의 파단 예측 반응지표 선정 (Appropriate Response Index for Predicting Rupture in WUF-W Connections using FEA)

  • 한상환;김영우;김태오
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.205-213
    • /
    • 2017
  • The WUF-W moment connection is a pre-qualified connection that can be used for special moment frames specified in current seismic design specifications. Since the stress distribution near the connection varies according to access hole configuration, the cyclic performance of WUF-W connections is strongly affected by the access hole configurations. To evaluate the connection performance according to various access hole configurations, it is expensive to conduct experiments with many connection specimens. Instead, finite element analyses (FEA) can be performed. Throughout the FEA, stress and strain distribution in the connection can be monitored at each loading step. The purpose of this study is to construct nonlinear 3-dimensional FE models for accurately predicting the cyclic behavior of WUF-W connections. For predicting connection fracture using FEA, an appropriate response index detecting the incidence of connection rupture is proposed.

Experimental study of the behavior of beam-column connections with expanded beam flanges

  • Ma, Hongwei;Wang, Jiwei;Lui, Eric M.;Wan, Zeqing;Wang, Kun
    • Steel and Composite Structures
    • /
    • 제31권3호
    • /
    • pp.319-327
    • /
    • 2019
  • This paper describes an experimental study of steel beam-column connections with or without expanded beam flanges with different geometries. The objectives of this study are to elucidate the cyclic behavior of these connections, identify the location of the plastic hinge zone, and provide useful test data for future numerical simulations. Five connection specimens are designed and tested under cyclic load. The test setup consists of a beam and a column connected together by a connection with or without expanded beam flanges. A constant axial force is applied to the column and a time varying point load is applied to the free end of the beam, inducing shear and moment in the connection. Because the only effect to be studied in the present work is the expanded beam flange, the sizes of the beam and column as well as the magnitude of the axial force in the column are kept constant. However, the length, width and shape of the expanded beam flanges are varied. The responses of these connections in terms of their hysteretic behavior, failure modes, stiffness degradation and strain variations are experimentally obtained and discussed. The test results show that while the influence of the expanded beam flanges on hysteretic behavior, stiffness degradation and energy dissipation capacity of the connection is relatively minor, the size of the expanded beam flanges does affect the location of the plastic hinge zone and strain variations in these beam-column joints. Furthermore, in terms of ductility, moment and rotational capacities, all five connections behave well. No weld fracture or premature failure occurs before the formation of a plastic hinge in the beam.

RBS 약축 용접모멘트접합부의 내진성능 평가 (Cyclic Seismic Performance of RBS Weak-Axis Welded Moment Connections)

  • 이철호;정종현;김성용
    • 한국강구조학회 논문집
    • /
    • 제27권6호
    • /
    • pp.513-523
    • /
    • 2015
  • H형강 철골 모멘트 골조에서는 기둥의 강축 방향 용접 모멘트접합부를 활용하는 것이 구조적으로 가장 이상적이다. 하지만, 모멘트 골조가 직교하는 경우, 기둥의 약축 방향으로도 용접 모멘트접합부를 사용해야 한다. 국내에서는 특히 강축 및 약축 방향 모두를 용접 모멘트접합부를 자주 사용하는 관행이 있다. 대표적인 연성내진상세인 RBS(reduced beam section, 보단면감소)접합부의 경우 국내외적으로 강축접합 위주로 실험연구가 진행되어 약축 RBS 용접모멘트접합부에 대한 실험자료가 매우 희소하다. 본 연구에서는 RBS를 도입한 약축 용접 모멘트접합부의 내진성능을 실험적으로 고찰하였다. Gilton-Uang (2002)의 선행연구를 참고하여 보 플랜지는 연속판과 맞댐용접하고 웨브는 전단이음판과 C-형 필릿용접부로 설계하여 실험을 수행하였다. 보에 사용된 강재가 내진용 강재가 아닌 일반 SS400 강재임에도 불구하고 3% 이상의 소성회전각을 발휘하였다. 제한된 결과이긴 하지만, 전단이음판과 보 웨브 사이의 C-형 필릿용접부 설계에서 보 웨브에 작용하는 휨모멘트와 전단력의 편심의 영향을 구체적으로 고찰할 필요가 있는 것으로 판단된다. 본 실험결과를 토대로 전단이음판 부근의 보 웨브 파단을 방지할 수 있는 C-형 필릿용접 형상 및 설계방안을 제안하였다. 보 플랜지와 연속판의 완전용입 용접부는 맞댄이음(butt joint) 형식이 되어 국부좌굴에 취약하고 이로 인해 피로파괴가 발생하는 경향이 있으므로 용접작업에 지장이 없는 범위에서 용접접근공(스켈럽)의 크기를 최소화할 필요가 있다. RBS형상, 스틱아웃, 트림, 연속판 두께 증가 등과 같이 이미 검증된 약축 모멘트 용접접합부의 내진상세들은 따르는 것이 바람직하다.